| Description | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Glycogen and starch generate glucose-1-phosphate (1PG/G1P) during the process of phosphohydrolysis. This reagent kit provides a simple, sensitive, and rapid determination method: Glucose-1-phosphate (1PG/G1P) is reduced from NADP+to NADPH by the sequential action of phosphoglucose mutase and Glycogen and starch generate glucose-1-phosphate (1PG/G1P) during the process of phosphohydrolysis. This reagent kit provides a simple, sensitive, and rapid determination method: Glucose-1-phosphate (1PG/G1P) is reduced from NADP+to NADPH by the sequential action of phosphoglucose mutase and phosphoglucose dehydrogenase. The content of glucose-1-phosphate (1PG/G1P) in the sample can be calculated by detecting the increase in NADPH at 340nm.Composition and preparation of reagent kit: Reagent name Specifications Save requirements Remarks Extraction solution Liquid 100mL x 1 bottle 4 ℃ storage / Reagent 1 Powder mg x 1 tube 4 ℃ storage Shake or centrifuge the reagent a few times before use to make it fall to the bottom, then dissolve it in 1.2mL of distilled water for later use. Reagent 2 Powder mg x 1 tube Store at -20 ℃ Shake or centrifuge the reagent a few times before use to make it fall to the bottom, then dissolve it in 1.2mL of distilled water for later use. Reagent 3 Liquid 16mL x 1 bottle 4 ℃ storage / Reagent 4 Powder mg x 1 tube Store at -20 ℃ Shake or centrifuge the reagent a few times before use to make it fall to the bottom, then add 1 Dissolve 1mL of distilled water for later use. TRC 1 powder 4 ℃ storage Only used to identify whether the reagents in the kit are normal (not involved in result calculation). Usage: Use a pre standard tube (GIP) to shake the powder a few times until it falls to the bottom, then add 0.5mL of distilled water and mix well to dissolveDilute GIP with a concentration of 4mg/mL and then dilute it four times to 1mg/mL for later use: follow the instructions in the sample addition table for the measuring tube operationRequired instruments and supplies:ELISA reader, 96 well plate, desktop centrifuge, adjustable pipette, mortar, ice and distilled water.Determination of glucose-1-phosphate (1PG/G1P) content:1. Sample preparation① Organizational sample:Suggest weighing around 0 1g of tissue, add 1mL of extraction solution, and homogenize in an ice bath. Centrifuge at 12000rpm, 4 ℃ for 10 minutes, take the supernatant, and place it on ice for testing.[Note]: If the sample size is increased, it can be extracted in a ratio of tissue mass (g) to extraction solution volume (mL) of 1:5-10.② Bacterial/cellular samples:Collect bacteria or cells into a centrifuge tube first, centrifuge and discard the supernatant; Take about 5 million bacteria or cells and add them to 1mLExtract solution, sonicate bacteria or cells (ice bath, power 200W, sonication for 3s, interval 10s, repeated 30 times); Centrifuge at 12000rpm at 4 ℃ for 10 minutes, take the supernatant, and place it on ice for testing.[Note]: If the sample size is increased, extraction can be carried out in a ratio of 500-1000:1 of bacteria/cell quantity (104) to extraction solution (mL).③ Liquid sample: direct detection.2. Machine testing:① Preheat the enzyme-linked immunosorbent assay (ELISA) reader for at least 30 minutes and adjust the wavelength to 340nm.② Thaw the reagent to room temperature (25 ℃);③ Add reagents to the 96 well plate in the following order according to the table:② Thaw the reagent to room temperature (25 ℃);③ Add reagents to the 96 well plate in the following order according to the table: Reagent name (µL) Measurement tube Blank tube (only done once) Reagent 1 10 10 Reagent 2 10 10 Reagent 3 150 170 Sample 20 / Mix well, incubate at room temperature (25 ℃) for 20 minutes, and then read A1 at 340nm (if the A value continues to increase, the incubation time needs to be extended until the absorbance value remains unchanged within 2 minutes). Reagent 4 10 10 Mix well, incubate at room temperature (25 ℃) for 20 minutes, and then read A2 at 340nm (if the A value continues to increase, the incubation time needs to be extended until the absorbance value remains unchanged within 2 minutes). Δ A=(A2-A1) measurement - (A2-A1) blank.[Note] 1 If the difference in Δ A is hovering around zero, the sample size V1 can be increased (such as increasing to 50 µ L, the three phases of the reagent should be reduced while keeping the total volume unchanged), or the sample sampling mass W can be increased. The changed V1 and W need to be substituted into the formula for recalculation.If the A2 value exceeds 1.2, the amount of sample added V1 can be reduced (such as to 10 µ L, the three-phase reagent should be increased while keeping the total volume unchanged), or the sample can be diluted with distilled water (keeping the sample addition system unchanged), and the changed V1 and D need to be substituted into the formula for recalculation.Result calculation:1. Calculated by sample weight:1PG/G1P content (µ g/g fresh weight)=[(Δ A ÷ (ε× d) × V2 × 106 × MR] ÷ (W × V1 ÷ V) × D=836 × Δ A ÷ W × D2. Calculated by the number of cells:1PG/G1P content (µ g/104 cell)=[(Δ A ÷ (ε× d) × V2 × 106 × MR] ÷ (500 × V1 ÷ V) × D=1.7 × Δ A × D. 3. Calculated by liquid volume:1PG/G1P content (µ g/mL)=[(Δ A ÷ (ε× d) × V2 × 106 × Mr] ÷ V1=836 × Δ A ε---NADPH Molar extinction coefficient,6.22×103 L/mol/cm; d---96 Orifice plate optical diameter,0.5cm; V---Add volume of extraction solution,1 mL; V1---Add sample volume,0.02mL V2---Total reaction volume;0.2mL=2×10-4L; W---Sample quality,g; Mr---Glucose-1-phosphate(1PG/G1P)Molecular weight;260; 500---Number of cells, in millions; D---Dilution ratio,Undiluted is 1。 /... Read More | Product content:ComponentG665836100 rxnsG665836100 rxnsG665836100 rxns2×GoldStar Probe One Step Buffer1.4 ml1.4 ml1.4 mlGoldStar Probe One Step EnzymeMix100 µl100 µl100 µl50×Low ROX-50 µl-50×High ROX--50 µlRNase-Free Water1.5 ml1.5 ml1.5 mlProduct IntroductionProduct content:ComponentG665836100 rxnsG665836100 rxnsG665836100 rxns2×GoldStar Probe One Step Buffer1.4 ml1.4 ml1.4 mlGoldStar Probe One Step EnzymeMix100 µl100 µl100 µl50×Low ROX-50 µl-50×High ROX--50 µlRNase-Free Water1.5 ml1.5 ml1.5 mlProduct Introduction:This product is a specialized reagent kit for one-step Real Time RTqPCR using probe methods (TaqMan, Molecular Beacon, etc.). When using this product for Real Time RT qPCR reaction, reverse transcription and quantitative PCR are requiredConducted in the same reaction system, there is no need to add reagents or open the tube cap during the reaction process, avoiding contaminationThis has improved the efficiency of the experiment. This product has high detection sensitivity, strong fluorescence signal, and high signal-to-noise ratio, making it very suitable forDetection of RNA viruses and other trace amounts of RNA. The special buffering system it contains can enable reverse transcriptase to interact with DNA polymeraseMaximize the effectiveness and improve reaction efficiency. By using this product, a wider linear range can be obtained, which is beneficial for the target base Due to more accurate quantification, good repeatability, and high reliability.ROX dye is used to correct the fluorescence signal error generated between wells in quantitative PCR instruments, and is generally used for ABIReal Time PCR amplification equipment from companies such as Stratagene. The excitation optical systems of different instruments vary, thereforeThe concentration of ROX dye must be matched with the corresponding fluorescence quantitative PCR instrument.matters needing attention:1. Before using the reagents in this reagent kit, please gently mix them upside down to avoid foaming as much as possible, and use them after brief centrifugation. 2. This product uses RNA as a template for one-step RT-PCR experiments, and RNase contamination should be avoided during the operation process,2.It is recommended to perform RNA operations in a dedicated area, using specialized instruments and consumables. Operators should wear masks and disposable gloves and frequently change gloves. Experimental consumables should be treated with a 0.1% DEPC (diethyl pyrocarbonate) aqueous solution at 37 ℃ for 12 hours and sterilized under high pressure for 30 minutes before use.3. Each reagent in this kit should avoid repeated freezing and thawing as much as possible, as repeated freezing and thawing may lead to a decrease in product performance.4. This reagent kit must use specific primers, and the selection of primers can be based on specific experiments. The quality of primer design directly affects the results of RT qPCR reaction. When designing primers, GC content, primer length, and primer should be considered Due to factors such as location, secondary structure of PCR products, it is recommended to use professional primer design software for design.5. It is recommended to use specific probes in this reagent kit and use professional design software for design. Usage: The following examples are typical reaction systems and conditions. In practical operation, corresponding improvements and optimizations should be made based on the differences in template, primer structure, and target fragment size. (Please prepare the reaction solution on ice)1. Dissolve the RNA template, primers, 2xGoldStar Probe One Step Buffer, GoldStar Probe One Step EnzymeMix, and RNase Free Water and place them on ice for later use.2. PCR reaction system: reagent 25 µl Reaction system final concentration 2×GoldStar Probe One Step Buffer 12.5 µl 1× Forward Primer,10 µM 0.5 µl 0.2 µM 1) Reverse Primer,10 µM 0.5 µl 0.2 µM 1) Probe ,10 µM 0.5 µl 0.2 µM 2) GoldStar Probe One Step EnzymeMix 1.0 µl / RNA Template X µl 10 pg – 100 ng3) 50×Low ROX or High ROX (optional)4) 0.5 µl 1× RNase-Free Water up to 25 µl /Note: 1) Typically, the primer concentration is 0.2 µ M can achieve good results, ranging from 0.1 to 1.0 µ M serves as a reference for setting the range. 2) The concentration of the probe used is related to the fluorescent quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance. Please refer to the instrument manual or the specific usage requirements of each fluorescent probe for concentration adjustment during actual use.3) The amount of RNA templates is usually based on 10 pg-100 ng as a reference. Due to the different copy numbers of target genes contained in templates of different species, gradient dilution can be applied to the templates to determine the optimal template usage.4) The excitation optical systems of different instruments vary, and depending on the instrument used for fluorescence quantification, 50 x Low ROX or 50 x High ROX can be added.3. Mix well, centrifuge briefly, and collect the solution to the bottom of the tube.4. RT-PCR reaction conditions steps temperature time / Reverse Transcription 45℃ 10 min / PCR pre denaturation 95℃ 10 min / denaturation 95℃ 15s 30-40cycle Annealing/Extension 60℃ 45s 30-40cycleAttention:1) The hot start enzyme used in this product must be activated under pre denaturation conditions of 95 ℃ and 5-10 minutes.2) It is recommended to use a two-step PCR reaction program. If good experimental results cannot be obtained due to the use of primers with lower Tm values, a three-step PCR amplification can be attempted. The annealing temperature should be set within the range of 56 ℃ -64 ℃ as a reference... Read More | Product contentS666146Component50 T200 TStorageS666146ABuffer GR25 mL120 mLRTS666146BBuffer GL25 mL120 mLRTS666146CBuffer GW1 (concentrate)13 mL52 mLRTS666146DBuffer GW2 (concentrate)15 mL75 mLRTS666146EBuffer GE15 mL60 mLRTS666146FProteinase K1.25 mL4×1.25 mLRTS666146GSpin Columns DS with Product contentS666146Component50 T200 TStorageS666146ABuffer GR25 mL120 mLRTS666146BBuffer GL25 mL120 mLRTS666146CBuffer GW1 (concentrate)13 mL52 mLRTS666146DBuffer GW2 (concentrate)15 mL75 mLRTS666146EBuffer GE15 mL60 mLRTS666146FProteinase K1.25 mL4×1.25 mLRTS666146GSpin Columns DS with Collection Tubes50 sets 200 setsRTS666146HCentrifuge Tubes (1.5 mL)50 EA200 EARTProductsThis kit provides a simple and rapid method for the isolation and purification of total DNA from buccal swab samples. The kit adopts a silica matrix membrane that can specifically bind DNA and a unique buffer system to adsorb DNA efficiently and specifically, and 0.5-3.5 µg of genomic DNA can be obtained from each swab, and the extracted DNA fragments are large, pure and of stable and reliable quality. It is suitable for enzyme digestion, PCR, library construction, Southern hybridization and other experiments.Self-contained reagent: anhydrous ethanol.Pre-experiment Preparation and Important Notes1. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.2. If precipitation is found in Buffer GL before use, dissolve Buffer GL in a 56°C water bath.3. All centrifugation steps can be performed at room temperature.4. Sampling: Use a buccal swab to wipe the inside of the mouth 6 times, dry for 2 hours and store. To ensure that the sample is not contaminated by food or drink, do not eat or drink for 30 minutes before sampling.Procedure1. The swab of the buccal swab was cut from the rod with scissors and placed in a 2mL centrifuge tube (supplied) and 400µL Buffer GR was added.Note: For genomic DNA without RNA contamination, add 4 µL of RNase A solution at a concentration of 100 mg/ml and shake to mix.2. Add 20 µL of Proteinase K and 400 µL of Buffer GL, immediately vortex and shake for 15 seconds and mix thoroughly.Note: Mix well immediately after adding Buffer GL; do not add Proteinase K directly to Buffer GL for use.3.56°C for 10 minutes and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.4. Add 400 µL of anhydrous ethanol, vortex and shake to mix thoroughly, and centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube.Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.5. Add the solution and precipitate obtained in the previous step to the Spin Columns DS in two batches of up to 700 µL at a time into the collection tube. centrifuge the column at 12,000 rpm (∼13,400 × g) for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.6. Add 500 µL of Buffer GW1 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.7. Add 500 µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge the column at 12,000 rpm for 3 minutes, pour off the waste liquid in the collection tube, and put the column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 1 minute and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new 1.5 mL centrifuge tube, add 50 µL of Buffer GE or sterilized water to the middle of the adsorption column overhanging the column, let stand at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store at -20℃.Attention:(1) If the downstream experiment is sensitive to pH or EDTA, it can be eluted with sterilized water. The pH value of the eluent has a great influence on the elution efficiency. If the eluent is made of water, the pH value should be 7.0-8.5 (the pH value of water can be adjusted to this range by using NaOH), and the elution efficiency is not high when the pH value is lower than 7.0.2) For long-term storage, it is recommended to elute with Buffer GE and store at -20°C... Read More | Product content: U665923Component50 T200 TStorageU665923ABuffer GTL15 mL60 mLRTU665923BBuffer GL15 mL50 mLRTU665923CBuffer GW1 (concentrate)13 mL52 mLRTU665923DBuffer GW2 (concentrate)15 mL70 mLRTU665923EBuffer GE15 mL60 mLRTU665923FProteinase K1.25 mL4×1.25 mLRTU665923GSpin Columns DM with Product content: U665923Component50 T200 TStorageU665923ABuffer GTL15 mL60 mLRTU665923BBuffer GL15 mL50 mLRTU665923CBuffer GW1 (concentrate)13 mL52 mLRTU665923DBuffer GW2 (concentrate)15 mL70 mLRTU665923EBuffer GE15 mL60 mLRTU665923FProteinase K1.25 mL4×1.25 mLRTU665923GSpin Columns DM with Collection Tubes50 EA200 EART Product Introduction:This reagent kit is suitable for extracting high-purity total DNA from various samples such as fresh or frozen animal tissues, cells, blood, bacteria, etc. This product can purify DNA fragments with a maximum molecular weight of 50 kb. The purification process does not require the use of toxic solvents such as phenol or chloroform, nor does it require ethanol precipitation. This reagent kit adopts an optimized buffer system to efficiently and specifically bind DNA from the lysis solution to the silica matrix centrifuge adsorption column. Inhibitors of PCR and other enzymatic reactions can be effectively removed through a two-step washing step. Finally, high-purity DNA can be obtained by washing with low salt buffer or water. The purified DNA can be directly used for downstream experiments such as enzyme digestion, PCR, Real Time PCR, library construction, Southern Blot, and molecular labeling.Self prepared reagent: anhydrous ethanolEnzymatic Lysis Buffer (preparation required for extracting genomic DNA from Gram positive bacteria).Self prepared reagent: Enzymatic Lysis Buffer Formula: 20 mM Tris, pH 8.0; 2 mM Na2 EDTA; 1.2% Triton self prepared reagent: X-100; Lysozyme with a final concentration of 20 mg/mL.Preparation and important precautions before the experiment:1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.If extracting the genome of bacterial cultures with a large accumulation of secondary metabolites or thick cell walls, it is recommended to collect samples early in the logarithmic growth phase.3.Before the first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer GTL and Buffer GL. If there is any crystallization or precipitation, please dissolve Buffer GL and Buffer GTL again in a 56 ℃ water bath.5. If downstream experiments are sensitive to RNA contamination, 4 can be added before adding Buffer GL µ RNase A of L DNase Free (100 mg/mL) was not provided in this kit.Operation steps:Genome extraction from blood and cell samples1. Material processing1a If the extracted material is mammalian anticoagulant blood (non nucleated red blood cells), it can be directly directed to 50-200 µ Add Buffer GTL to fresh or frozen anticoagulant blood samples to supplement up to 200 µ L;1b If the extracted material is anticoagulant blood from poultry, birds, amphibians, or lower level organisms, and their red blood cells are nucleated cells, take 5-10 µ L fresh or frozen anticoagulant blood samples, add Buffer GTL to supplement up to 200 µ L;1c The cells cultured on the wall should be first processed into a cell suspension (with a maximum extraction amount of 5 × 10 cells), centrifuged at 2000 rpm (400 × g) for 5 minutes, discarded from the supernatant, and added with 200 µ L GTL, oscillate until the sample is completely suspended;Note: To remove RNA, add 4 after completing the above steps µ RNase A solution with a concentration of 100 mg/mL was vortexed for 15 seconds and left at room temperature for 2 minutes.2. Add 20 µ L Protein K.3. Add 200 µ L Buffer GL, vortex oscillation thoroughly mixed, 56 ℃ water bath for 10 minutes.4. Temporarily centrifuge to remove water droplets from the inner wall of the tube cover. Join 200 µ L anhydrous ethanol, vortex and shake thoroughly to mix well. Short centrifugation.Attention: 1) After adding Bu ff er GL and anhydrous ethanol, immediately vortex shake and mix well.2) The addition of Bu ff er GL and anhydrous ethanol may produce white precipitates, which will not affect subsequent experiments. Some organizations may form sol-gel products after adding Bu ff er GL and anhydrous ethanol, and it is recommended to perform severe shaking or vortex treatment at this time.5. Add all the solutions obtained in the previous step to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.6. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Note: To further improve DNA purity, repeat step 7.8.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).9. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Attention:1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high.2) Preheating the GE in a water bath at 65-70 ℃ and incubating it at room temperature for 5 minutes before centrifugation can increase yield; Use an additional 50-200 µ Re washing with GE or sterilized water can increase yield.3) If the final concentration of DNA needs to be increased, the obtained solution can be re added to the adsorption column, left at room temperature for 2-5 minutes, and centrifuged at 12000 rpm for 1 minute; If the elution volume is less than 200 µ L. It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with GE or sterilized water.4) Because DNA stored in water is affected by acidic hydrolysis, if long-term preservation is required, it is recommended to elute with Bu ff er GE and store at -20 ℃.Genome extraction from animal tissues1. Material processingIf the extracted material is animal tissue, take 25 mg (the amount of spleen tissue should be less than 10 mg); If the material is mouse tail, take a section of rat tail with a length of 0.4-0.6 cm or two sections of mouse tail with a length of 0.4-0.6 cm.1a. After liquid nitrogen grinding or cutting the sample into small pieces, place it in a 1.5 mL centrifuge tube and add 180 mL µ Label different samples with L Buffer GTL.1b If using a homogenizer to process the sample, add no more than 80% of the homogenizer to the sample before homogenization µ L Buffer GTL, add 100 after homogenization µ L Buffer GTL.Attention:1) Ensure that the quantity of each organization does not exceed the recommended range.2) The tissue samples can be ground with liquid nitrogen or homogenized with a homogenizer before adding Bu ff er GTL, which can increase the cracking efficiency.2. Add 20 µ L Protein K, vortex oscillation thoroughly mixes the sample. Take a 56 ℃ water bath until the tissue is completely lysed. During the incubation process, the centrifuge tube can be inverted or shaken periodically to disperse the sample.Attention:1) The digestion time varies for different tissues, usually taking 1-3 hours to complete. The tail of the mouse needs to be digested for 6-8 hours, and if necessary, overnight digestion will not affect subsequent operations.2) If there is still gel like substance after incubation and vortex oscillation, extend the incubation time at 56 ℃ or add another 20 µ L Protein K digestion.3) To remove RNA, add 4 after completing the above steps µ RNase A solution with a concentration of 100 mg/mL, vortex for 15 seconds, and leave at room temperature for 5-10 minutes.3. Add 200 µ L Buffer GL, vortex shake thoroughly and mix well, take a water bath at 70 ℃ for 10 minutes. Add 200 after brief centrifugation µ L anhydrous ethanol, vortex and shake thoroughly to mix well.Attention:1) After adding Bu ff er GL and anhydrous ethanol, immediately vortex and shake to mix well.2) The addition of Bu ff er GL and anhydrous ethanol may produce white precipitates, which will not affect subsequent experiments. Some tissues (such as the spleen and lungs) may form sol-gel products after adding Bu ff er GL and anhydrous ethanol. In this case, it is recommended to perform vigorous shaking or vortex treatment.4. Centrifuge briefly and add all the solution obtained in step 3 to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.5. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.6. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Note: To further improve DNA purity, repeat step 6.7.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).8. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Attention:1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high.2) Preheating the GE in a water bath at 65-70 ℃ and incubating it at room temperature for 5 minutes before centrifugation can increase yield; Use an additional 50-200 µ Re washing with GE or sterilized water can increase yield.3) If the final concentration of DNA needs to be increased, the obtained solution can be re added to the adsorption column, left at room temperature for 2-5 minutes, and centrifuged at 12000 rpm for 1 minute; If the elution volume is less than 200 µ L. It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with GE or sterilized water.4) Because DNA stored in water is affected by acidic hydrolysis, if long-term preservation is required, it is recommended to elute with Bu ff er GE and store at -20 ℃. i ii Genomic extraction of blood and cell samples1. Bacterial sample pretreatment1a Gram negative bacteria(1) Take 1-5mL of bacterial culture (10 ^ -10 ^ cells, up to a maximum of 2 × 10 ^ cells) and place it in a centrifuge tube (self prepared). Centrifuge at 12000 rpm (~13400 × g) for 1 minute and try to aspirate the supernatant as much as possible.(2) Add 180 to the precipitate µ L Buffer GTL, shake to suspend bacterial weight.(3) Join 20 µ L Protein K, vortex mix well, incubate at 56 ° C until the bacterial cell is completely lysed, and during the incubation process, invert or shake the centrifuge tube periodically to disperse the sample.Note: To remove RNA, add 4 after completing the above steps µ L RNase A solution with a concentration of 100 mg/mL, shake well and let stand at room temperature for 5-10 minutes.(4) Join 200 µ L Buffer GL, vortex oscillation mixing.1b Gram positive bacteria(1) Take 1-5 mL of bacterial culture (10 ^ -10 ^ cells, maximum not exceeding 2 x 10 ^ cells) and place it in a centrifuge tube (self prepared). Centrifuge at 12000 rpm for 1 minute and try to aspirate the supernatant as much as possible.(2) Join 180 µ L Enzymatic Lysis Buffer (self provided) suspends the bacterial weight.(3) Incubate at 37 ℃ for 30 minutes.(4) Join 20 µ L Protein K vortex oscillation, thoroughly mixed. Join 200 µ L Buffer GL, vortex oscillation mixing. Incubate at 56 ℃ for 30 minutes.Attention:1) If necessary, incubation at 95 ° C for 15 minutes can inactivate the pathogen, but incubation at 95 ° C can cause some DNA degradation.2) To remove RNA, add 4 after completing the above steps µ L RNase A solution with a concentration of 100 mg/mL, shake well and let stand at room temperature for 5-10 minutes.2. Add 200 µ L anhydrous ethanol, vortex and shake thoroughly to mix well.Attention: Adding anhydrous ethanol may produce white precipitates, which will not affect subsequent experiments.3. Add all the solution obtained from step 2 (including the formed precipitate) to the adsorption column (Spin Columns DM) that has been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.4. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.5. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Note: To further improve DNA purity, repeat step 5.6.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).7. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Attention:1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high.2) Preheating the GE in a water bath at 65-70 ℃ and incubating it at room temperature for 5 minutes before centrifugation can increase yield; Use an additional 50-200 µ Re washing with GE or sterilized water can increase yield.3) If the final concentration of DNA needs to be increased, the obtained solution can be re added to the adsorption column, left at room temperature for 2-5 minutes, and centrifuged at 12000 rpm for 1 minute; If the elution volume is less than 200 µ L. It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with GE or sterilized water.4) Because DNA stored in water is affected by acidic hydrolysis, if long-term preservation is required, it is recommended to elute with Bu ff er GE and store at -20 ℃... Read More |