| Description | Product introduction:Product introduction:Cell Cycle Assay Kit Plus ( Cell Cycle Assay Kit Plus ) has certain applicability for live cells and fixed cell cycle detection. For different types of cells, whether it is applicable or not needs to be determined after testing. Cell Cycle Product introduction:Product introduction:Cell Cycle Assay Kit Plus ( Cell Cycle Assay Kit Plus ) has certain applicability for live cells and fixed cell cycle detection. For different types of cells, whether it is applicable or not needs to be determined after testing. Cell Cycle Assay Kit Plus ( Cell Cycle Assay Kit Plus ) uses RedNucleus I staining to detect cell cycle. RedNucleus I is a far-infrared nucleic acid dye with cell membrane permeability, which can quickly enter living cells, specifically bind to DNA, and perform cell cycle detection on living cells without RNase digestion. Compared with the traditional PI staining method, the cells do not need to be broken or fixed, and the operation is simpler. RedNucleus I is a fluorescent dye of double-stranded DNA, and the fluorescence intensity after binding to double-stranded DNA is proportional to the content of double-stranded DNA. The intracellular DNA content can be measured by flow cytometry, and then the cell cycle analysis can be carried out according to the distribution of DNA content. After RedNucleus I staining, assuming that the fluorescence intensity of G0 / G1 phase cells is 1, the theoretical value of the fluorescence intensity of G2 / M phase cells containing two copies of genomic DNA is 2, and the fluorescence intensity of S phase cells undergoing DNA replication is between 1-2. In addition, RedNucleus I is compatible with dyes such as Horizon BV / BUV, FITC and R-PE, and can be periodically detected after sample staining.The kit is usually used to detect the cell cycle of cultured adherent or suspended cells. If it is used for cell cycle detection of tissues, the tissues must be digested into a single cell state.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. this product is applicable to the detection of living cells and fixed cell cycle with certain limitations. Whether it is applicable to different types of cells needs to be determined after testing. If fixation is needed, it is recommended to use ice bath pre cooling 75-80% ethanol -20 ℃ to fix cells overnight. 3. fluorescent dyes have quenching problems. Please try to avoid light during storage and use to slow down fluorescence quenching. 4. for your safety and health, please wear experimental clothes and disposable gloves.Instruction: Experimental materials ( self-provided ):①cell lines or other cell samples ( self-prepared ) ;②This kit ; ③ trypsin ( self-prepared ) ;④ Cell culture medium containing FBS ( self-prepared ) ; Experimental procedure: 1.Preparation of cell samples : ( 1 ) ( This step is for adherent cells, if suspended cells, can be carried out directly step ( 2 ) ) Digest cells with trypsin, add cell culture medium, gently blow away cells, collected into the centrifuge tube. Note : The number of cells on the machine needs to reach 50,000 and above, so the initial number of cells collected needs to be sufficient. ( 2 ) Centrifuged about 1000 g for 3-5 min to precipitate cells. Carefully remove the supernatant, add about 1 mL of ice bath pre-cooled 1 × staining buffer ( 10 × staining buffer diluted with diH2O at 1 : 10 ), re-suspend the cells. Repeat once. ( 3 ) Centrifuged about 1000 g for 3-5 min to precipitate cells. After the supernatant was discarded, 1 mL of culture medium was added to re-suspend the cells ( for fixed cells, 1 × PBS can also be used to re-suspend ). Gently flick the bottom of the centrifuge tube to properly disperse the cells to avoid cell aggregation. 2.Staining : 4 µL of RedNucleus I staining solution was added to each tube of cell samples, slowly and fully mixed, and incubated at room temperature in dark for 20 min ( or incubated at 37 ° C in dark for 5-10 min ). The optimal incubation time of different cells is different, and the staining time can be adjusted and optimized according to the actual staining effect to obtain a more ideal staining effect. 3.Flow cytometry detection and analysis : Excited at 638 nm by flow cytometry, it is recommended to detect in RL3 or FL4 channels, or use RL1 and RL2 channels. Cell DNA content analysis and light scattering analysis were performed using appropriate analysis software.Scope of application:Cell cycle detection... Read More | Inquire | Store at -20°C. Please refer to protocols | Product content: M665559Component50 TStorageM665559ABuffer GTT15 mLRTM665559BBuffer GL15 mLRTM665559CBuffer GW1(concentrate)13 mLRTM665559DBuffer GW2(concentrate)15 mLRTM665559EBuffer GE15 mLRTM665559FProteinase K1.25 mLRTM665559GSpin CoLumns DM with CoLLection Tubes50 Product content: M665559Component50 TStorageM665559ABuffer GTT15 mLRTM665559BBuffer GL15 mLRTM665559CBuffer GW1(concentrate)13 mLRTM665559DBuffer GW2(concentrate)15 mLRTM665559EBuffer GE15 mLRTM665559FProteinase K1.25 mLRTM665559GSpin CoLumns DM with CoLLection Tubes50 EART Product Introduction:This reagent kit is suitable for extracting high-purity total DNA from fresh or frozen mouse or rat tails. The method provided by this reagent kit is simple and feasible, and the purification process does not require phenol or chloroform extraction. It can obtain DNA fragments up to 50 kb, and can also effectively recover fragments of 100 bp. This reagent kit uses a unique lysis solution to effectively lyse mouse tail samples. The optimized buffer system efficiently binds the DNA generated after the lysis of mouse tail to the silica matrix adsorption column, while other pollutants can flow through the membrane; Inhibitors of PCR and other enzymatic reactions can be effectively removed through a two-step washing process, followed by washing with low salt buffer or water to obtain high-purity DNA. The purified DNA can be directly used for downstream experiments such as enzyme digestion, PCR, ReaL Time PCR, library construction, Southern BLot, and molecular labeling.Self prepared reagent: anhydrous ethanol.Preparation and important precautions before the experiment:1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.Before the first use, anhydrous ethanol should be added to BufferGW1 and BufferGW2 according to the instructions on the reagent bottle label.3. Before use, please check if there is any crystallization or precipitation in the Buffer GL. If there is any crystallization or precipitation, please dissolve the Buffer GL again in a 56 ℃ water bath.Operation steps:1. Take a tail of a rat or two mice with a length of 0.4-0.6 cm, grind it into fine powder in liquid nitrogen or cut it into pieces and place it in a centrifuge tube (provided by oneself). Join 180 µ L Buffer GTT, shake and mix well. Note: Ensure that the starting quantity of the organization does not exceed the recommended range.2. Add 20 µ L Protein K, vortex oscillation, thoroughly mix.3. Place in a 56 ℃ water bath until the tissue solution is completely clear. Generally, digestion is required for 6-8 hours. During the incubation process, vortex oscillation is required to evenly disperse the sample. Note: 1) If there is still gel like substance after incubation and vortex oscillation, digest overnight or add 20 more if necessary µ L Protein K digestion will not affect subsequent operations. 2) To remove RNA, add 4 after completing the above steps µ L 100 mg/mL RNase A solution, shake well and let stand at room temperature for 5-10 minutes.4.12000 rpm (~13400 × g) for 1 minute to remove undigested tissues similar to mouse hair. Transfer the supernatant to a new centrifuge tube (provided by oneself).5. Add 200 µ L Buffer GL, vortex oscillation, thoroughly mixed. Join 200 µ L anhydrous ethanol, vortex and shake, thoroughly mix. Short centrifugation allows the solution on the tube wall to be collected to the bottom of the tube.Attention: 1) After adding Buffer GL and anhydrous ethanol, immediately vortex and shake to mix well.2) If multiple samples are operated together, Buffer GL and anhydrous ethanol can be mixed in equal proportions and added to the samples together.3) The addition of Buffer GL and anhydrous ethanol may produce white precipitates, which will not affect subsequent experiments.6. Add all the solutions obtained in step 5 to the adsorption column (Spin CoLumins DM) that has been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.8. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Note: To further improve DNA purity, repeat step 8.9.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).10. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Note: 1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high.2) Incubating at room temperature for 5 minutes before centrifugation can increase yield.3) Use an additional 50-200 µ Re washing with L Buffer GE or sterilized water can increase yield.4) If you want to increase the final concentration of DNA, you can add the DNA eluent obtained in step 10 back onto the adsorption membrane and repeat step 10; If the elution volume is less than 200 µ L. It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ L Buffer GE or off... Read More | Inquire |