| Description | Product content:ComponentG665836100 rxnsG665836100 rxnsG665836100 rxns2×GoldStar Probe One Step Buffer1.4 ml1.4 ml1.4 mlGoldStar Probe One Step EnzymeMix100 µl100 µl100 µl50×Low ROX-50 µl-50×High ROX--50 µlRNase-Free Water1.5 ml1.5 ml1.5 mlProduct IntroductionProduct content:ComponentG665836100 rxnsG665836100 rxnsG665836100 rxns2×GoldStar Probe One Step Buffer1.4 ml1.4 ml1.4 mlGoldStar Probe One Step EnzymeMix100 µl100 µl100 µl50×Low ROX-50 µl-50×High ROX--50 µlRNase-Free Water1.5 ml1.5 ml1.5 mlProduct Introduction:This product is a specialized reagent kit for one-step Real Time RTqPCR using probe methods (TaqMan, Molecular Beacon, etc.). When using this product for Real Time RT qPCR reaction, reverse transcription and quantitative PCR are requiredConducted in the same reaction system, there is no need to add reagents or open the tube cap during the reaction process, avoiding contaminationThis has improved the efficiency of the experiment. This product has high detection sensitivity, strong fluorescence signal, and high signal-to-noise ratio, making it very suitable forDetection of RNA viruses and other trace amounts of RNA. The special buffering system it contains can enable reverse transcriptase to interact with DNA polymeraseMaximize the effectiveness and improve reaction efficiency. By using this product, a wider linear range can be obtained, which is beneficial for the target base Due to more accurate quantification, good repeatability, and high reliability.ROX dye is used to correct the fluorescence signal error generated between wells in quantitative PCR instruments, and is generally used for ABIReal Time PCR amplification equipment from companies such as Stratagene. The excitation optical systems of different instruments vary, thereforeThe concentration of ROX dye must be matched with the corresponding fluorescence quantitative PCR instrument.matters needing attention:1. Before using the reagents in this reagent kit, please gently mix them upside down to avoid foaming as much as possible, and use them after brief centrifugation. 2. This product uses RNA as a template for one-step RT-PCR experiments, and RNase contamination should be avoided during the operation process,2.It is recommended to perform RNA operations in a dedicated area, using specialized instruments and consumables. Operators should wear masks and disposable gloves and frequently change gloves. Experimental consumables should be treated with a 0.1% DEPC (diethyl pyrocarbonate) aqueous solution at 37 ℃ for 12 hours and sterilized under high pressure for 30 minutes before use.3. Each reagent in this kit should avoid repeated freezing and thawing as much as possible, as repeated freezing and thawing may lead to a decrease in product performance.4. This reagent kit must use specific primers, and the selection of primers can be based on specific experiments. The quality of primer design directly affects the results of RT qPCR reaction. When designing primers, GC content, primer length, and primer should be considered Due to factors such as location, secondary structure of PCR products, it is recommended to use professional primer design software for design.5. It is recommended to use specific probes in this reagent kit and use professional design software for design. Usage: The following examples are typical reaction systems and conditions. In practical operation, corresponding improvements and optimizations should be made based on the differences in template, primer structure, and target fragment size. (Please prepare the reaction solution on ice)1. Dissolve the RNA template, primers, 2xGoldStar Probe One Step Buffer, GoldStar Probe One Step EnzymeMix, and RNase Free Water and place them on ice for later use.2. PCR reaction system: reagent 25 µl Reaction system final concentration 2×GoldStar Probe One Step Buffer 12.5 µl 1× Forward Primer,10 µM 0.5 µl 0.2 µM 1) Reverse Primer,10 µM 0.5 µl 0.2 µM 1) Probe ,10 µM 0.5 µl 0.2 µM 2) GoldStar Probe One Step EnzymeMix 1.0 µl / RNA Template X µl 10 pg – 100 ng3) 50×Low ROX or High ROX (optional)4) 0.5 µl 1× RNase-Free Water up to 25 µl /Note: 1) Typically, the primer concentration is 0.2 µ M can achieve good results, ranging from 0.1 to 1.0 µ M serves as a reference for setting the range. 2) The concentration of the probe used is related to the fluorescent quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance. Please refer to the instrument manual or the specific usage requirements of each fluorescent probe for concentration adjustment during actual use.3) The amount of RNA templates is usually based on 10 pg-100 ng as a reference. Due to the different copy numbers of target genes contained in templates of different species, gradient dilution can be applied to the templates to determine the optimal template usage.4) The excitation optical systems of different instruments vary, and depending on the instrument used for fluorescence quantification, 50 x Low ROX or 50 x High ROX can be added.3. Mix well, centrifuge briefly, and collect the solution to the bottom of the tube.4. RT-PCR reaction conditions steps temperature time / Reverse Transcription 45℃ 10 min / PCR pre denaturation 95℃ 10 min / denaturation 95℃ 15s 30-40cycle Annealing/Extension 60℃ 45s 30-40cycleAttention:1) The hot start enzyme used in this product must be activated under pre denaturation conditions of 95 ℃ and 5-10 minutes.2) It is recommended to use a two-step PCR reaction program. If good experimental results cannot be obtained due to the use of primers with lower Tm values, a three-step PCR amplification can be attempted. The annealing temperature should be set within the range of 56 ℃ -64 ℃ as a reference... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | DescriptionUse in combination with the KitAlysis Bench Top Inertion Box (Z742064) or a glove box/glove bag to provide inert atmosphere for kit set-up.Designed to be used with KitAlysis High-Throughput Screening Kits.Components:24-Well Reaction BlockTorque ScrewdriverSmall screwdriver to easily DescriptionUse in combination with the KitAlysis Bench Top Inertion Box (Z742064) or a glove box/glove bag to provide inert atmosphere for kit set-up.Designed to be used with KitAlysis High-Throughput Screening Kits.Components:24-Well Reaction BlockTorque ScrewdriverSmall screwdriver to easily remove torqued screws after reaction is complete.10 Reaction Block Replacement Screws... Read More | This product can rapidly, gently, and efficiently lyse mammalian cells, effectively extracting cytoplasmic and nuclear proteins. This reagent uses a mild formula to ensure that the extracted protein maintains biological activity and can be applied to various protein analysis experiments, such as This product can rapidly, gently, and efficiently lyse mammalian cells, effectively extracting cytoplasmic and nuclear proteins. This reagent uses a mild formula to ensure that the extracted protein maintains biological activity and can be applied to various protein analysis experiments, such as reporter gene and enzyme activity determination, immune detection, protein purification, etc. The extracted protein can be quantitatively analyzed using the BCA method. The reagent kit contains a mixture of protease inhibitors, which can effectively prevent protein degradation during the protein extraction process.M665813Component100 TStorageM665813AMammalian Protein Extraction Reagent100 mLRTM665813BProtease Inhibitor Cocktail (100×)1 mL-20℃. Avoid freeze/thaw cycle. precautions1. This product can effectively lyse adherent cells cultured on cell culture plates (without scraping) and suspended cells collected by centrifugation, with higher extraction efficiency than repeated freeze-thaw or ultrasound methods. But for the extraction of tissue proteins, it is recommended to use the tissue protein extraction kit (CW0891).The optimal dosage for protein extraction from adherent cells is listed in Table 1. Collecting cells first can reduce the amount of reagents used to obtain higher protein concentrations.3. The amount of extraction reagents used can also be estimated based on the number of cells. If 2 × 106 Hela cells weigh about 20 mg, 200 need to be added µ Extract reagents.4. The protein extracted from this product can be quantitatively analyzed using the BCA method.Operation steps● Protein extraction from adherent cells1. Please remove the required Mammalian Protein Extraction Agent for pre cooling before protein extraction.2. Carefully pour out the culture medium of adherent cells and rinse the cells with PBS.3. Add an appropriate amount of Mammalian Protein Extraction Reagent (add Protein Inhibitor Cocktail in a 1:99 ratio 2-3 minutes before protein extraction), blow adherent cells on ice with a gun tip, transfer the lysate to a centrifuge tube, incubate on ice for 20 minutes, and allow the cells to fully lyse (please refer to Appendix 1 for the amount of reagent used, and the time for placing on ice should be adjusted according to different cell types). 4. Centrifuge at 14000 × g for 5-10 minutes.5. Transfer the supernatant to a new tube for further analysis. ● Suspension cell protein extraction1. Please remove the required Mammalian Protein Extraction Agent for pre cooling before protein extraction.2. Suspend 2500 × g of cells, centrifuge for 10 minutes, and discard the supernatant. Rinse cells with PBS. 2500 × g, centrifuge for 10 minutes, discard the supernatant.3. Add an appropriate amount of Mammalian Protein Extraction Agent, and 2-3 minutes before protein extraction, add Protein Inhibitor Cocktail in a ratio of 1:99, which is 1 x working solution.4. Add at least 1 ml of 1x working solution to every 100 mg of cells. If the extracted sample size is large, a small amount of 1x working solution can be used to resuspend the cells first, and then the remaining working solution can be added.5. After blowing evenly, place it on ice for 20 minutes to allow the cells to fully lyse (the time for placing it on ice should be adjusted according to different cell types). 6. Centrifuge at 14000 × g for 15 minutes.7. Transfer the supernatant to a new tube for further analysis.Table 1. Recommended usage of extraction reagents Cell culture plate type or dish type Extraction reagent usage 100 mm 500-1,000 µl 60 mm 250-500 µl 6-well culture plate 200-400 µl /well 24-well culture plate 100-200 µl /well 96-well culture plate 50-100 µl /well Table 2. Common Problems and Solutions Problem Possible reasons Resolvent Low extraction rate Low protein expression level Optimize transfection system Low extraction rate Insufficient reagent usage Increase the usage of extraction reagents Low extraction rate Reagent unable to dissolve cell membrane Increase cracking time or increase shaking amplitude Unable to obtain membrane protein This product is more suitable for extracting nuclear plasma protein Using eukaryotic cell membrane protein extraction kit... Read More | Products content Products IntroductionThis kit is a dedicated sample preparation solution for microbiome analysis and is suitable for the purification and enrichment of genomic DNA of pathogenic microorganisms such as bacteria and fungi from mixed samples such as swabs, blood, sputum, alveolar Products content Products IntroductionThis kit is a dedicated sample preparation solution for microbiome analysis and is suitable for the purification and enrichment of genomic DNA of pathogenic microorganisms such as bacteria and fungi from mixed samples such as swabs, blood, sputum, alveolar lavage, etc. During the purification process, differential lysis of the host cells and subsequent enzymatic digestion can effectively remove most of the host DNA while providing a comprehensive coverage of the bacterial and fungal DNA loci to a higher level. By differential lysis of host cells and subsequent enzymatic digestion, this kit can effectively remove most of the host DNA while maximizing the full coverage of bacterial, fungal and other pathogenic microbial DNA sites, thus obtaining microbiome DNA enrichment products with a higher coverage. Microbial DNA purified with this kit is suitable for a variety of downstream applications, including whole genome sequencing analysis, 16S rDNA-based high sensitivity microbiome analysis, and macrogenomic birdshot sequencing analysis. Self-contained reagents and consumablesSterile pipette tips with aerosol barrier to prevent cross-contamination anhydrous ethanol Microcentrifuge tubes (2 ml/1.5 ml) PBS buffer (required for some samples only)Pre-experiment Preparation and Important Notes1. Add 1.25 ml Proteinase K Storage Buffer to Proteinase K and store at -20℃. Do not leave the prepared Proteinase K (20 mg/ml) at room temperature for a long time, and avoid repeated freezing and thawing to avoid affecting its activity.2. Dissolve Lysozyme (100 mg) in 10 ml Enzymatic Lysis Buffer to a final concentration of 10 mg/ml, dispense into sterile tubes and store at -20℃. Do not leave the prepared Lysozyme (10 mg/ml) at room temperature for a long time and avoid repeated freezing and thawing to avoid affecting its activity.3. Thaw Buffer GB1 and Buffer GB2 at room temperature or 2-8°C before use and mix thoroughly. Thawed Buffer GB1 and Buffer GB2 can be left at 2-8°C for 1-2 weeks without affecting their activity, and should be stored at -20°C for long term storage. To ensure optimal performance, do not freeze or thaw more than three times. If less than one bottle of Buffer GB1 and Buffer GB2 is required for a single extraction, ensure that it is used under sterile conditions such as an ultra-clean bench and avoid microbial contamination and growth in the remaining buffer.4. Before first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the vial label and labeled.5. Check Buffer GL for crystallization or precipitation before use, and if crystallization or precipitation occurs, redissolve Buffer GL in a 56°C water bath.6. If the downstream experiments are sensitive to RNA contamination, 4 µl of DNase-Free RNase A (100 mg/ml) can be added before adding Buffer GL. RNase A is not provided in the kit, but can be ordered separately from CW0601S.7. This kit is designed for the isolation of DNA from intact microbial cells. To ensure optimal recovery of microbial DNA, samples should be fresh. If storage or transportation is required, this should preferably be done at 2-8°C and not frozen or thawed, as freezing and thawing can damage the integrity of the microbial cells and therefore result in the loss of exposed microbial DNA during host DNA removal.8. To avoid false results due to contamination, keep the work area clean, wear protective clothing, and set up controls for quality control. Use appropriate measures to handle sample materials to minimize the risk of cross-contamination. During the extraction process, use DNA-free pipette tips and consumables, and cap reagents immediately after use to prevent contamination. procedure1. Sample pre-treatment: 1a: For swab samples, swirl the swab portion of the swab in 0.5 ml PBS for at least 20 s. Squeeze the swab several times against the wall of the tube before removing it so that as much of the bacterial fluid as possible can be squeezed out of the swab to minimize sample loss. 1b: For viscous samples, e.g. sputum, take ~500 µl of sample, add 1.5 times the volume (~750 µl) of Buffer GB1 and incubate at 37°C, 600 rpm for 15-30 min until the sample is completely liquefied.Note: The sample volume can be increased or decreased appropriately and the amount of Buffer GB1 added adjusted accordingly.1c: For alveolar lavage fluid containing a small amount of viscous sputum, centrifuge as much of the alveolar lavage fluid as possible, carefully remove the supernatant, and retain the lower viscous fraction (containing sputum, cells, and organisms), add 1.5 times the volume of Buffer GB1, and incubate for 15-30 min at 37°C, 600 rpm until the sample is completely liquefied.1d: For non-viscous body fluid samples such as blood and cerebrospinal fluid, liquefaction treatment is not required, and an appropriate amount of sample is taken directly, the operation of step 2 is carried out, and the cell precipitate is collected by centrifugation.2. Centrifuge at 10000 rpm for 5-10 min at room temperature and carefully discard the supernatant.Note: Do not disturb the lower cell sediment to avoid sample loss.3. Add 500 µl Buffer GB2, vortex to mix, and incubate at room temperature, 600 rpm for 10 min. 4. Centrifuge at 12000 rpm for 2 min and carefully remove the supernatant.Note: Do not disturb the bacterial precipitate when removing the supernatant to avoid sample loss.5. Add 200 µl of Buffer GB2 to the precipitate, add 2 µl of Benzonase and incubate for 30 min at 37°C, 600 rpm. 6. Centrifuge at 12000 rpm for 2 min, discard the supernatant, add 500 µl of Buffer GB2, vortex and wash the precipitate. Repeat the procedure once.7. Centrifuge at 12000 rpm for 2 min, discard the supernatant, and finally aspirate the residual Buffer GB2 with a small-volume tip. 8. Add 180 µl Lysozyme (10 mg/ml), resuspend the bacterial precipitate and transfer the bacterial resuspension to a Lysis Tube.9. The Lysis Tube is incubated at 37°C, 600 rpm for 20-30 min, then vortexed for 10 min or processed on a thermostatic homogenizer for 10 min at maximum vibration speed (2500-2900 rpm).10. Centrifuge briefly, add 20 µl proteinase K, vortex to mix, add 200 µl buffer GL, vortex to mix, and incubate for 30 min at 56°C, 600 rpm. Note: 1) Do not add Proteinase K directly to Buffer GL.2)For RNA removal, add 4 µl DNase-Free RNase A (100 mg/ml) before adding Buffer GL, shake to mix, and let stand at room temperature for 5-10 minutes.11. Centrifuge at 12000 rpm for 1 min and carefully aspirate the supernatant into a new centrifuge tube. Note: Do not aspirate the glass beads.12. Add 200 µl of anhydrous ethanol, vortex to mix, and centrifuge momentarily to collect the solution to the bottom of the tube. Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.13. Add all of the solution from step 12, including the precipitate, to the Spin Columns DM in the collection tube, or transfer the solution several times if it cannot be added all at once. centrifuge at 12,000 rpm for 1 minute, pour off the waste from the collection tube, and return the column to the collection tube.14. Add 500 µl Buffer GW1 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 min, pour off the waste liquid from the collection tube, and put the adsorbent column back into the collection tube.15. Add 500 µl Buffer GW2 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube. Note: Step 15 can be repeated once if further improvement of DNA purity is required.16. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the column at room temperature for a few minutes and dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorbent column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).17. Place the adsorbent column in a new centrifuge tube (supplied), add 50 µl of Buffer GE to the center of the adsorbent column overhang, let stand at room temperature for 5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20 °C. Attention:1)If the downstream experiments are sensitive to pH or EDTA, sterilized water can be used for elution. The pH value of the eluent has a great influence on the elution efficiency. If the eluent is made of water, the pH value should be 7.0-8.5 (the pH value of water can be adjusted to this range with NaOH), and the elution efficiency is not high when the pH value is lower than 7.0.2)Incubation at room temperature for 5 minutes prior to centrifugation increases yield.3)If the final concentration of DNA is to be increased, the DNA eluate obtained in step 17 can be re-spiked onto the adsorbent membrane and step 17 repeated. 4)DNA stored in water will be affected by acidic hydrolysis. For long-term storage, it is recommended to elute with Buffer GE and store at -20℃... Read More |