| Description | Inquire | B669951 Component 50T Storage B669951A Buffer ATL 15 mL RT B669951B Buffer AL 15 mL RT B669951C Buffer AW1 (concentrate) 13 mL RT B669951D Buffer AW2 (concentrate) 15 mL RT B669951E Buffer EB 15 mL RT B669951F Proteinase K 1.25 mL RT B669951G Spin Columns DM with Collection Tubes 50 sets B669951 Component 50T Storage B669951A Buffer ATL 15 mL RT B669951B Buffer AL 15 mL RT B669951C Buffer AW1 (concentrate) 13 mL RT B669951D Buffer AW2 (concentrate) 15 mL RT B669951E Buffer EB 15 mL RT B669951F Proteinase K 1.25 mL RT B669951G Spin Columns DM with Collection Tubes 50 sets RTProductsThis kit is suitable for extracting high purity total DNA from Gram-negative and Gram-positive bacteria. 106-108 cells can be processed at a time, and up to 20 µg of total DNA can be obtained within one hour without the need for toxic solvents such as phenol or chloroform, and without the need for ethanol precipitation. The optimized buffer system enables the DNA in the lysate to be efficiently and specifically bound to the silica matrix centrifugal adsorption column, while other contaminants can flow through the membrane, and the inhibitors of PCR and other enzymatic reactions can be effectively removed through a two-step washing step, and finally washed off with low-salt buffer or water, so that high-purity DNA can be obtained.The purified DNA can be used for downstream experiments such as digestion, PCR, Real-Time PCR, library construction, Southern Blot and molecular labeling, molecular labeling and other downstream experiments. Self-contained reagents: anhydrous ethanol; Enzymatic Lysis Buffer is required for extraction of Gram-positive bacteria.Enzymatic Lysis Buffer was prepared by 20 mM Tris, pH 8.0; 2 mM Na2-EDTA, pH 8.0; and 1.2% Triton X-100. 121°C sterilization for 20 minutes, and the appropriate amount of Lysozyme was added at a final concentration of 20 mg/ml. Pre-experiment Preparation and Important Notes1. Add 1.25ml Proteinase K Storage Buffer to Proteinase K to dissolve it and store it at -20℃. Do not leave the prepared Proteinase K at room temperature for a long time, and avoid repeated freezing and thawing to avoid affecting its activity.2. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller DNA fragments and a decrease in the amount of extracted DNA.3. If extracting genomes from bacterial cultures with high accumulation of secondary metabolites or thick cell walls, it is recommended that samples be collected early in the logarithmic phase.4. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.5. Before use, please check Buffer GTL and Buffer GL for crystallization or precipitation. If crystallization or precipitation occurs, please re-dissolve Buffer GL and Buffer GTL in a 56℃ water bath.6. If the downstream experiments are sensitive to RNA contamination, 4µl of DNase-Free RNase A (100mg/ml) can be added before adding Buffer GL. RNase A is not provided in this kit.If the extracted samples are Gram-positive bacteria, customers need to prepare their own Enzymatic Lysis Buffer to treat the bacteria, which requires the use of Lysozyme (lysozyme) at a concentration of 20 mg/ml, which is not provided in this kit.Procedurei Extraction of genomic DNA from Gram-negative bacteria1. Take 1-5 ml of bacterial culture (106-108 cells, maximum 2×109 cells) and put it into a centrifuge tube (provided), centrifuge it at 12,000 rpm (~13,400×g) for 1 minute, and aspirate the supernatant as much as possible.2. Add 180 µl Buffer GTL to the precipitate and shake to resuspend the bacteria.3. Add 20 µl of Proteinase K, vortex and mix well, incubate at 56°C until the solution becomes clear, and invert or shake the centrifuge tube at intervals during the incubation to disperse the sample.Note: If RNA removal is required, add 4 µl of RNase A solution at a concentration of 100 mg/ml after the above steps are completed, shake to mix, and leave for 5-10 minutes at room temperature.4. Add 200µl Buffer GL and mix well with vortexing and shaking. Add 200µl of anhydrous ethanol and mix well with vortexing and shaking.Centrifuge briefly so that the solution on the walls of the tube collects at the bottom.Note: 1) If multiple samples are manipulated together, Buffer GL and anhydrous ethanol can be mixed in equal proportions and then added together, shaking to mix.2) The addition of Buffer GL and anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.5. Add all of the solution obtained in step 4 (including the precipitate formed) to the Spin Columns DM in the collection tube, or if the solution cannot be added all at once, transfer it several times. centrifuge at 12,000 rpm for 1 minute, discard the waste solution, and return the column to the collection tube.6. Add 500 µl of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and return the adsorption column to the collection tube.7. Add 500 µl of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorbent column at room temperature for several minutes to dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorbent column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new centrifuge tube, add 50-200 µl Buffer GE to the middle part of the adsorption column overhanging the center of the adsorption column, leave it at room temperature for 2-5 minutes, centrifuge it at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20 ℃. note: 1) If the downstream experiments are sensitive to the pH or EDTA, the elution can be done with sterilized water. The pH of the elution solution has a great influence on the elution efficiency. If water is used as the elution solution it should be ensured that its pH is 7.0-8.5 (the pH of water can be adjusted to this range with NaOH), and the elution efficiency is not high when the pH is lower than 7.0.2) Incubation at room temperature for 5 minutes prior to centrifugation increases yield.3) Re-elution with an additional 50-200 µl Buffer GE or sterilized water can increase the yield.4) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 9 can be re-spiked onto the adsorbent membrane and step 9 repeated; if the elution volume is less than 200 µl, the final concentration of DNA can be increased, but the total yield may be reduced. If the amount of DNA is less than 1 µg, elution with 50 µl Buffer GE or sterilized water is recommended.(5) DNA stored in water will be affected by acidic hydrolysis. For long-term storage, it is recommended to elute with Buffer GE and store at -20℃.i. Extraction of genomic DNA from Gram-positive bacteria1. Take 1-5 ml of bacterial culture (106-108 cells, maximum 2×109 cells) and put it into a centrifuge tube (provided), centrifuge it at 12,000 rpm (~13,400×g) for 1 minute, and aspirate the supernatant as much as possible.2. Add 180µl Enzymatic Lysis Buffer (self-provided) to resuspend the bacteria.Enzymatic Lysis Buffer is prepared as described in the Self-Prepared Reagents section in the front of the manual.3. Incubate at 37°C for 30 minutes.4. Add 20µl Proteinase K and mix well. Add 200µl of Buffer GL and mix well with vortexing and shaking.Note: Do not add Proteinase K directly to Buffer GL.Incubate at 5.56°C for 30 minutes.Note: 1) If desired, incubation at 95°C for 15 minutes will inactivate the pathogen, but 95°C incubation will cause some DNA degradation.(2) If RNA removal is required, add 4µl of RNase A solution at a concentration of 100mg/ml after the above steps are completed, shake and mix well, and leave for 5-10 minutes at room temperature.6. Add 200µl of anhydrous ethanol and mix well with vortex shaking.Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.7. Add all of the solution obtained in step 6 (including the precipitate formed) to the Spin Columns DM that have been loaded into the collection tube, and if the solution cannot be added all at once, it can be transferred in several times. centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid from the collection tube, and put the column back into the collection tube.8. Add 500 µl of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.9. Add 500 µl Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge the column at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the column back into the collection tube.Note: Step 9 can be repeated if further DNA purity is required.10. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self-provided), add 50-200 µl of Buffer GE to the center of the adsorption column overhanging the center of the adsorption column, let it stand at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20℃.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH is 7.0-8.5 (you can use NaOH to adjust the pH of the water to this range), and the elution efficiency is not high when the pH is lower than 7.0.2) Incubation at room temperature for 5 minutes prior to centrifugation increases yield.3) Re-elution with an additional 50-200 µl Buffer GE or sterilized water can increase the yield.4) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 11 can be re-spiked onto the adsorbent membrane and step 11 repeated; if the elution volume is less than 200 µl, the final concentration of DNA can be increased, but the total yield may be reduced. If the amount of DNA is less than 1 µg, elution with 50 µl Buffer GE or sterilized water is recommended.(5) DNA stored in water will be affected by acidic hydrolysis. For long-term storage, it is recommended to elute with Buffer GE and store at -20℃... Read More | EndoFree Plasmid Midi Kit Cat No. Component Size(50T) Storage E665631A Buffer P1 30 mL RT E665631B Buffer P2 30 mL RT E665631C Buffer E3 30 mL RT E665631D Buffer PS 15 mL RT E665631E Buffer PW (concentrate) 10 mL RT E665631F Endo-free Buffer EB 10 mL RTEndoFree Plasmid Midi Kit Cat No. Component Size(50T) Storage E665631A Buffer P1 30 mL RT E665631B Buffer P2 30 mL RT E665631C Buffer E3 30 mL RT E665631D Buffer PS 15 mL RT E665631E Buffer PW (concentrate) 10 mL RT E665631F Endo-free Buffer EB 10 mL RT E665631G RNase A (10 mg/mL) 600 µL RT E665631H Buffer ER 8 mL RT E665631I CWBlue 300 µL RT E665631J Spin Columns DL with Collection Tubes 50 EA RT E665631K Endo-Remover FM with Collection 50 EA RTProduct Introduction:Endotoxins are a common pollutant in plasmid extraction. Due to the high sensitivity of eukaryotic cells to endotoxins, the presence of endotoxins in plasmids can greatly reduce the transfection efficiency of eukaryotic cells. This reagent kit provides a simple, fast, and efficient new method for extracting endotoxin free plasmids. The extracted plasmids can remove endotoxins to the maximum extent possible and effectively remove contamination of genomic DNA, RNA, proteins, and other substances. This reagent kit is suitable for extracting 5-15mL of bacterial solution. On the basis of alkaline lysis of cells, it efficiently and specifically binds plasmid DNA through a new silicon-based membrane. Each adsorption column can adsorb up to 100 µ The plasmid DNA of g is effectively removed using a special buffer system and endotoxin removal filter column, effectively removing impurities such as endotoxins and proteins. The plasmid obtained from this kit has high purity and stable quality, making it particularly suitable for cell transfection. It can also be used for downstream experiments such as DNA sequencing, PCR, PCR based mutations, in vitro transcription, transformed bacteria, and endonuclease digestion.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1. All components can be stably stored in a dry, room temperature (15-30 ℃) environment for 1 year, and can be stored at 2-8 ℃ for longer periods of time. Buffer P1 with RNase A added can be stably stored at 2-8 ℃ for 6 months.2. Before the first use, add all RNase A solution to Buffer P1, mix well, and store at 2-8 ℃. Before use, let it sit at room temperature for a period of time. After returning to room temperature, use.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer P2 and Buffer E3. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. Be careful not to come into direct contact with Buffer P2 and Buffer E3, and immediately cover them tightly after use.6.The amount and purity of plasmid extraction are related to factors such as bacterial culture concentration, strain type, plasmid size, and plasmid copy number.Operation steps:1. Take 5-15 mL of overnight cultured bacterial solution and add it to a centrifuge tube (self provided). Centrifuge at 13000 rpm (~16200 × g) for 1 minute to collect bacteria, and try to discard all the supernatant as much as possible.2. Add 500 to the centrifuge tube containing bacterial sediment µ L Buffer P1 (please check if RNase A has been added first), mix thoroughly with a pipette or vortex oscillator, and suspend bacterial precipitation. Attention: If the bacterial blocks are not thoroughly mixed, it will affect the cracking effect, resulting in low extraction amount and purity.3. Add 500 to the centrifuge tube µ L Buffer P2, gently invert and mix 8-10 times, allowing the bacterial cells to fully lyse. Leave at room temperature for 3-5 minutes. At this point, the solution should become clear and viscous. Attention: Mix gently and do not shake vigorously to avoid interrupting genomic DNA and mixing genomic DNA fragments in the extracted plasmid. If the solution does not become clear, it indicates that the bacterial count may be too high and the lysis may not be complete. The bacterial count should be reduced.4. Add 500 to the centrifuge tube µ L Buffer E3, immediately invert and mix 8-10 times until white flocculent precipitates appear. Let it stand at room temperature for 5 minutes. Centrifuge at 13000 rpm for 5 minutes, extract the supernatant, and add it to the filter column (Endo Remove FM) (already loaded into the collection tube). Centrifuge at 13000 rpm for 1 minute to filter, then transfer the filtrate from the collection tube to the centrifuge tube (self provided). Attention: 1) After adding Buffer E3, it should be immediately mixed to avoid local precipitation. 2) The maximum volume of the adsorption column is 750 µ L. So please filter the supernatant twice and mix it in the same self provided centrifuge tube.5. Add 450 to the filtrate µ Mix L isopropanol upside down.6. Column balance: Add 200 to the spin columns DL that have been loaded into the collection tube µ L Buffer PS, centrifuge at 13000 rpm for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Transfer the mixed solution of filtrate and isopropanol from step 5 to an equilibrium adsorption column (already loaded into a collection tube). 8.13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. Attention: The maximum volume of the adsorption column is 750 µ L. So the solution obtained in step 5 is divided multiple times and passed through the column. 9. Add 750 to the adsorption column µ L Buffer PW (please check if anhydrous ethanol has been added first), centrifuge at 13000 rpm for 1 minute, and discard the waste liquid in the collection tube.10. Place the adsorption column back into the recovery manifold and centrifuge at 13000 rpm for 1 minute.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self provided)... Read More | This kit combines efficient guanidine isothiocyanate lysis technology with silicon matrix membrane purification technology to efficiently extract total RNA from animal cells and tissues. The starting sample usually has a maximum of 30 mg of tissue or 1 x 107 cells. This reagent kit can also recover This kit combines efficient guanidine isothiocyanate lysis technology with silicon matrix membrane purification technology to efficiently extract total RNA from animal cells and tissues. The starting sample usually has a maximum of 30 mg of tissue or 1 x 107 cells. This reagent kit can also recover partially purified RNA, RNA obtained from in vitro transcription and enzymatic reactions. This reagent kit can extract and purify high-quality RNA with a molecular weight greater than 200 bases, with almost no DNA residue. If RNA experiments are to be conducted that are highly sensitive to trace amounts of DNA, residual DNA can be digested and removed on a column using DNase I without RNase. The extracted RNA can be used for downstream experiments such as RT-PCR, Northern Blot, Dot Blot, etc. R666020Component50 TStorageR666020ABuffer RL35 mLRTR666020BBuffer RW140 mLRTR666020CBuffer RW2 (concentrate)11 mLRTR666020DRNase-Free Water10 mLRTR666020ESpin Columns RM with Collection Tubes50 setsRTR666020FRNase-Free Centrifuge Tubes (1.5 mL)50 EART Self prepared reagents: β- Mercaptoethanol, anhydrous ethanol (newly opened or dedicated for RNA extraction).Preparation and important precautions before the experimentTo prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The extracted samples should avoid repeated freeze-thaw cycles, otherwise it will affect the quantity and quality of RNA extraction.3. Before use, please check if there is any crystallization or precipitation in the Buffer RL. It can be heated at 56 ℃ and re solved. Please add Buffer RL before use β- Mercaptoethanol, with a final concentration of 1%. Add 10 to 1ml Buffer RL µ L β- Mercaptoethanol. join β- The buffer RL room temperature of mercaptoethanol can be stored for one month.4. Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.6. If downstream experiments are highly sensitive to DNA, it is recommended to treat RNA with DNase I that does not contain RNase.Operation steps1. Sample processing1a organization: Grind the organization in liquid nitrogen. Add 600 to every 20-30 mg of tissue µ L Buffer RL (check if it is added before use) β- Mercaptoethanol), tissue sample less than 20 mg plus 350 µ Buffer RL. The sample volume shall not exceed one tenth of the buffer RL volume.1b Single layer culture of cells: The cells are directly lysed or processed into cell suspensions in a culture bottle, centrifuged to obtain cell precipitates, and the supernatant is discarded. 600 is added every 6-10 cm2 of culture area µ Buffer RL, less than 6 cm2, add 350 µ Blow buffer RL several times to fully crack it.1c cell suspension: Centrifuge at 12000 rpm (~13400 × g) for 1 minute to discard the supernatant and obtain cell precipitate. Add 600 cells every 5 × 106-1 × 107 cells µ Buffer RL, less than 5 × 106 cells added to 350 µ Blow buffer RL several times to fully crack it.Attention:1) Try to eliminate the cell culture medium as much as possible, as it may inhibit cell lysis and affect RNA production.2) Try to fully suspend and lyse the cells, otherwise it will affect RNA production.2. After the sample is fully lysed, it should be left at room temperature for 5 minutes to completely separate the protein nucleic acid complex.3. Centrifuge at 2000rpm for 2-5 minutes, take the supernatant and proceed to the next step.4. Add 1 volume (600) µ L or 350 µ l) Mix 70% ethanol (prepared without RNase water) well.Attention: Adding ethanol may cause precipitation and will not affect subsequent experiments.5. Add all the solution obtained in step 4 to the Spin Columns RM that has been loaded into the collection tube. If it is not possible to add all the solution to the adsorption column at once, please transfer it in two batches, centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube. Attention: The maximum loading capacity of the adsorption column is 100 µ g, do not overload, otherwise it will affect the yield and purity of RNA.6. Add 700 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column in the collection tube.Optional steps: If conducting RNA experiments that are highly sensitive to trace amounts of DNA, replace step 6 with the following steps.1) Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 15 seconds, discard the waste liquid, and place the adsorption column back into the recovery manifold.2) Preparation of DNase I mixture: Take 52 µ Add 8 RNase Free Water to it µ 10 x Reaction Buffer and 20 µ DNase I (1 U/ µ l) Mix well and prepare to a final volume of 80 µ The reaction solution of L.Attention: The above system is configured according to our company's DNase I reaction system. Please refer to the corresponding manual for other company products.3) Add 80 µ l of the prepared DNase I reaction solution directly to the adsorption column and incubate at 20-30 ℃ for 15 minutes.4) Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 15 seconds, discard the waste liquid, and place the adsorption column back into the recovery manifold.7. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.8. Repeat step 7. 9. Centrifuge at 12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).10. Place the adsorption column in a new RNase free centrifuge tube, and add 30-50 to the middle of the adsorption column in the air µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 10 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 10... Read More | This reagent kit is based on TRIzon's improved columnar total RNA extraction kit. This product can be extracted from animal groupsExtract total RNA from samples such as textiles, plant materials, various microorganisms, and cultured cells. Firstly, the cracking solution is fully cracked This reagent kit is based on TRIzon's improved columnar total RNA extraction kit. This product can be extracted from animal groupsExtract total RNA from samples such as textiles, plant materials, various microorganisms, and cultured cells. Firstly, the cracking solution is fully cracked andHomogenized samples, in their unique high salt state, RNA specifically binds to silicon matrix membranes, greatly reducingEffectively removing organic solvent contamination while removing protein contamination, resulting in higher purity and quality of RNA. bookThe product can quickly extract total RNA from various cells or tissues, and can process 30-50 mg of tissue or 5 × 10 ⁶ cells each time,Can handle multiple different samples simultaneously. If it is an RNA experiment that is very sensitive to trace amounts of DNA, the residual DNA can be utilizedUsing DNase without RNase for digestion and removal on the column, the extracted RNA can be directly applied to RT-PCR Experiments such as Northern Blot, Dot Blot, and in vitro translation. U665516 Component 50 T Storage U665516A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. U665516B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. U665516C TRIzon Reagent 60 mL 2-8℃. Protect from light. U665516D TRIzon PaI™ 10 mL 2-8℃. Protect from light. U665516E Buffer RW1 40 mL RT U665516F Buffer RW2 (concentrate) 11 mL RT U665516G RNase-Free Water 10 mL RT U665516H Spin Columns RM with Collection Tubes 50 sets RT U665516I RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RTPreparation and important precautions before the experiment:1.To prevent RNase pollution, attention should be paid to the following aspects:1) RNase's plastic products and gun heads to avoid cross contamination.2) Prepare the solution using water without RNase.3) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The sample should avoid repeated freezing and thawing, otherwise it will affect the yield and quality of RNA extraction.3. If TRIzon Reagent is found to have precipitates before use, it can be dissolved in a water bath at 56 ℃ for a few minutes.Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Usage:1. Sample processing1a. Organization: 30-50 mg of tissue is thoroughly ground in liquid nitrogen and 1 mL of TRIzon Reagent is added, or 1 mL of TRIzon Reagent is added to the tissue sample and homogenized. Attention: The sample volume should not exceed 10% of the volume of TRIzon Reagent.2a. Single layer cell culture: Remove the culture medium and add an appropriate amount every 10 cm ² Add 1 mL of TRIzon Reagent.3a. Cell suspension: Collect cells by centrifugation. Add 1 mL of TRIzon Reagent to every 5 × 10 µ m cell.2. After adding TRIzon Reagent, repeatedly blow a few times to fully crack the sample. Leave at room temperature for 5 minutes to completely separate the protein nucleic acid complex.3. Add 200 to every 1 mL of TRIzon Reagent µ LTRIzon PaI ™, Cover the tube tightly, vigorously shake for 15 seconds, and let it sit at room temperature for 2 minutes.4. Centrifuge at 4 ℃ 12000 rpm (~13400 × g) for 10 minutes. At this time, the sample is divided into three layers: the red organic phase, the middle layer, and the upper colorless aqueous phase. RNA is mainly in the upper aqueous phase. Move the upper aqueous phase to a new RNase Free centrifuge tube (provided).5. Add an equal volume of 70% ethanol (prepared without RNase water) to the obtained aqueous solution, invert and mix well.6. Add all the solutions obtained in the previous step to the spin columns RM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred in multiple batches. Centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.8. Preparation of DNase I mixture: Take 52 µ LRNase Free Water, add 8 to it µ L 10 x Reaction Buffer and 20 µ L DNase I (1 U/ µ L) Mix well and prepare to a final volume of 80 µ The reaction solution of L.9. Directly add 80 µ L DNase I mixture to the adsorption column and incubate at 20-30 ℃ for 15 minutes.10. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 1 minute, discard the waste liquid, and place the adsorption column back into the recovery manifold.11. Add 500 to the adsorption column µ L Buffer RW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.12. Repeat step 11.Centrifuge at 12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes and thoroughly air dry. Attention: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (enzyme digestion,. )PCR, etc.14. Place the adsorption column in a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ L. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 14 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 14... Read More |