| Description | Products contentProducts IntroductionThis product uses the principle that the difference between the concentration of salt ions inside and outside the cell can cause the cell membrane to burst to lyses the cell and releases the genomic DNA, without the need of extracting and purifying the genomic Products contentProducts IntroductionThis product uses the principle that the difference between the concentration of salt ions inside and outside the cell can cause the cell membrane to burst to lyses the cell and releases the genomic DNA, without the need of extracting and purifying the genomic DNA.This product is suitable for a variety of sources of samples, and can be used as a template for PCR and qPCR experiments after sample processing, and can achieve the effect of the purified DNA used as a template for PCR and qPCR experiments. Usage1. Depending on the type of sample, prepare the appropriate sample size according to the table below.2. Add the sample to a 1.5-mi centrifuge tube and add the recommended volume of Solution A as shown in the table below. Vortex for 20 s and allow to stand at room temperature for 3-5 min or incubate in a metal bath at 95°C for 3-5 min as recommended in the table below.3. After the sample has been sufficiently lysed (samples incubated in a metal bath at 95°C should be brought to room temperature), add the recommended volume of Solution B as shown in the table below and vortex for 30s.4. Store processed samples at 4°C if the next test is to be performed within 2 hours, or at -20°C if the next test cannot be performed immediately.take note of1) Depending on the requirements of the experimental conditions, the amount of samples can be expanded or reduced, and the amount of Solution A and Solution B can be increased in equal proportions.2) For blood and cell samples, the temperature of room temperature lysis is required to be around 25C. If the ambient temperature does not reach 25°, the lysis time can be extended appropriately, or the vortex shaking time can be extended to ensure that the samples are fully lysed. If there is no relevant professional instrument, the centrifuge tube can be shaken vigorously to ensure adequate lysis.3) After the tissue sample is made into tissue homogenate by adding 10 times the volume of saline, it can be processed in the same way as blood samples.4) Strictly prohibit the use of expired products, please do not mix different reagents.5) laboratory supplies should be regularly cleaned and 10% of the 84 disinfectant solution or ultraviolet lamp for anti-pollution treatment, special areas dedicated to prohibit cross use, so as to avoid contamination, the end of the test, the bench should be cleaned immediately... Read More | Cell proliferation detection is a basic experimental method to evaluate the health of cells, genotoxicity and the effect of antitumor drugs. The most accurate method to detect cell proliferation is the BrdU method. Edu detection kit is a revolutionary breakthrough of BrdU method. Edu (5-ethynyl-2 '-Cell proliferation detection is a basic experimental method to evaluate the health of cells, genotoxicity and the effect of antitumor drugs. The most accurate method to detect cell proliferation is the BrdU method. Edu detection kit is a revolutionary breakthrough of BrdU method. Edu (5-ethynyl-2 '- deoxyuridine) is a pyrimidine analog that integrates into the DNA duplex during DNA synthesis. Edu detection is based on the "click" reaction. A copper catalyzed azide reacts covalently with alkynes to form covalent bonds. In this kit, edu contains alkynes, Aladdin ® 488 / 555/594/647a azide dyes contain azide compounds. The edu labeling proliferation of click method is rapid and effective, and easy to use. BrdU method requires DNA denaturation (such as acid denaturation, thermal denaturation or digestion with DNase) to expose BrdU, so as to facilitate BrdU antibody binding; The edu method only needs paraformaldehyde fixation and Triton X-100 penetration to make the detection reagent enter the cells, and only a small amount of azide dye is needed to label the integrated edu very effectively. This kit contains all components required for edu method detection, and can be used for proliferation detection of cultured cells in vitro. Component:Product parameters: 590/617 nm Instruction:Experimental materials (self provided). 10 mM PBS, pH 7.2-7.6. 4% paraformaldehyde fixing solution (in PBS)Propensive reagent (0.5% Triton X -100 in PBS). 2 mg/mL glycine solution (in ddH2O). 3% BSA in PBS, pH 7.2-7.6. 1% BSA in PBS, pH 7.2-7.6. ddH2O. 96/24/12/6 well culture plate or dishFluorescence microscopy detection method1. Cell cultureTake logarithmic growth stage cells and inoculate them into a 96 well plate with 4 × 103-1 × 105 cells per well (the number and density of cells can be adjusted according to cell size, growth rate, and specific requirements of experimental treatment), and culture until normal growth stage.2. Drug treatmentPerform various drug treatments according to experimental needs.3. EdU marking(1) Dilute EdU solution (component A) in a certain proportion with complete cell culture medium to an appropriate concentration, then add it to the cells and mix well; Set up a negative control group without EdU treatment.Note: The labeling concentration of EdU needs to be adjusted according to cell type, and it is recommended to explore with an initial concentration of 10 µ M. In the pre experiment, it is recommended to set an EdU concentration gradient, which can be referred to in Tables 2 and 3.(2) Incubate in a cell culture incubator for 2 hours.Note: The optimal incubation time is related to the cell cycle. Most tumor cell lines can use a 2-hour incubation time, as shown in Appendix 2. The concentration of EdU is related to incubation time,Short term incubation (<2 hours) should use high concentrations, such as 10-50 µ M; Long term incubation (>24 hours) should use low concentrations, such as 1-10 µ M; You can also refer to Appendix 3.4. Cell fixation and permeation promotionNote: For experiments that require cell surface antigen labeling, it can be considered to wash the cells twice with a 3% BSA washing solution after completing EdU incubation, before cell fixation and permeation promotion.(1) After incubation, remove the culture medium. Wash cells twice with 1X PBS for 5 minutes each time to remove EdU residues that have not been incorporated into DNA. Cells with weak adhesion can reduce cleaning intensity. Join 50 µ After incubating at room temperature for 20 minutes with 4% paraformaldehyde fixative, remove the fixative.(2) Add 50 to each hole µ L 2 mg/mL glycine solution, incubate at room temperature for 5 minutes, and neutralize the remaining fixed solution.(3) At a rate of 100 per hole µ Wash cells twice with 3% BSA.(4) Remove the washing solution and add 100 µ L 0.5% Triton X -100, incubate at room temperature for 10 minutes.5. EdU detectionNote: Each sample in this reference step uses 100 µ The working fluid of L can be adjusted by users according to their own sample situation.(1) Prepare 1 x Click iT EdU reaction buffer (component C): Dilute component C 10 times with ddH2O.(2) Configure 5 x Click iT EdU buffer additives (component E): add 300 µ Mix L of ddH2O into a 30 mg E component tube (final concentration of 100 mg/mL) until completely dissolved. After use, the remaining storage solution is stored at -20 ℃ and can be stored for one year. Once the solution turns brown, it indicates that the active ingredients have degraded and cannot be reused.Note: Different specifications of component E are dissolved in ddH2O according to this ratio, and prepared into a 5 x storage solution for future use.(3) Prepare 1 x Click iT EdU buffer additive: Dilute 5 x Click iT EdU buffer additive with ddH2O to 1 x, and the solution should be prepared and used immediately.(4) Prepare Click it working solution according to Table 1.Table 1 Click it working fluid Reaction components Taking the sample size of 10 holes as an example 1 x Click it EdU reaction buffer 855 µL CuSO4 (component D) 40 µL YF® 488/555/594/647A Azide(Component B) 5 µL 1 x Click it EdU buffer additive 100 µL Total volume 1 mL (5) Remove penetration enhancer, 100 per well µ Wash twice with 3% BSA washing solution of L.(6) Add 100 to each hole µ L Click iT working solution, evenly covering cells.(7) Incubate at room temperature in dark for 30 minutes.(8) Remove Click-iT working fluid and add 100 µ After washing cells twice with 3% BSA, remove the washing solution and add 100 µ L PBS keeps cells moist. If there are no other special requirements, photography analysis can be carried out.6. DNA re staining (optional)(1) Using 100 µ Wash the cells once with PBS and remove the washing solution.(2) Dilute Hoechst 33342 (component F) 2000 times with PBS.(3) Add 100 to each hole µ Incubate L 1 x Hoechst 33342 solution at room temperature in dark for 15-30 minutes.(4) Remove Hoechst 33342 solution and use 100 µ Wash cells twice with PBS.7. Imaging and analysisIt is recommended to take fluorescence microscopy photos immediately after staining is completed for observation; If conditions permit, please store in a dark and moist environment at 4 ° C for 3 days before taking photos. Flow cytometry detection method1. Cell cultureInoculate 1 × 105~3 × 106 cells per well into a 6-well plate.2. Drug treatmentPerform various drug treatments according to experimental needs.3. EdU labeled cells(1) Dilute EdU solution (component A) in a certain proportion with complete cell culture medium to an appropriate concentration, then add it to the cells and mix well; Set up a negative control group without EdU treatment.Note: The labeling concentration of EdU needs to be adjusted according to cell type, and it is recommended to explore with an initial concentration of 10 µ M. In the pre experiment, it is recommended to set an EdU concentration gradient, which can be referred to in Tables 2 and 3.(2) Incubate in a cell culture incubator for 2 hours. The time of EdU incubation of cells can be directly used as an indicator for measuring cell DNA synthesis, and the choice of time point and incubation time depend on the cell growth rate. Pulse labeled cells incubated with brief EdU can be used to study cell cycle dynamics.Note: The optimal incubation time is related to the cell cycle. Most tumor cell lines can use a 2-hour incubation time, as shown in Appendix 2. The concentration of EdU is related to the incubation time, and high concentrations, such as 10-50, should be used for short-term incubation (<2 hours) µ M; Long term incubation (>24 hours) should use low concentrations, such as 1-10 µ M; You can also refer to Appendix 3.4. Cell fixation and permeation promotionNote: For experiments that require cell surface antigen labeling, it can be considered to wash cells twice with 1% BSA after completing EdU incubation, before cell fixation and permeation promotion.(1) After incubation, collect cells, add 1 mL of PBS to each tube to clean the cells, centrifuge at 1000 rpm for 5 minutes, and discard the supernatant to remove EdU residue that has not been added to DNA.(2) Add 1 mL of 4% paraformaldehyde fixative to each tube to resuspend cells.(3) Incubate at room temperature for 20 minutes, centrifuge at 1000 rpm for 5 minutes, and discard the supernatant.(4) Add 1 mL of 2 mg/mL glycine to each tube and incubate for 5 minutes. Neutralize the remaining fixed solution, centrifuge at 1000 rpm for 5 minutes, and discard the supernatant. Add 1 mL of PBS to each tube for cleaning once, centrifuge at 1000 rpm for 5 minutes, and discard the supernatant.(5) Add 1mL of 0.5% Triton X-100 osmotic enhancer to each tube and resuspend cells. Incubate at room temperature for 10 minutes.5. EdU detectionNote: For 6-well plate samples, reference can be made to 1 mL of working solution per well. Users can adjust the dosage according to their own sample situation.(1) Prepare 1 x Click iT EdU reaction buffer: Dilute component C 10 times with ddH2O.(2) Prepare 5 x Click iT EdU buffer additives (component E): Add 300 µ L ddH2O to 30 mg of component E in a test tube (final concentration 100 mg/mL), mix well until completely dissolved. After use, the remaining storage solution is stored at -20 ℃ and can be stored for one year. Once the solution turns brown, it indicates that the active ingredients have degraded and cannot be reused.Note: Different specifications of component E are dissolved in ddH2O according to this ratio to form 5 x storage solution for future use.(3) Prepare 1 x Click iT EdU buffer additive: Dilute 5 x Click iT EdU buffer additive storage solution with ddH2O to 1 x, and the solution should be prepared and used immediately.(4) Prepare Click it working solution according to Table 2.Table 2 Click it working fluid Reaction components Volume of liquid required for a single reaction 1×Click-iT EdU reaction buffer 875 µL CuSO4 (component D) 20 µL YF® 488/555/594/647A Azide(Component B) 5 µL 1×Click-iT EdU buffer additive 100 µL Total volume 1 mL (5) Soak at 1000 rpm for 5 minutes, discard the supernatant, remove the enhancer, add 1mL of 1% BSA washing solution to each tube and wash twice. Soak at 1000 rpm for 5 minutes, discard the supernatant.(6) Add 1 mL of Click iT working solution to each tube and mix well.(7) Incubate at room temperature in dark for 30 minutes.(8) Soak at 1000 rpm for 5 minutes, discard the staining reaction solution, add 1% BSA to each tube to wash the cells twice, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, and resuspend the cells again with 1 mL of 1% BSA (the volume of resuspend cells can be adjusted according to the number of cells), and detect with a flow cytometer.Note: If other biomarker tests are required, please refer to step 4.6. Intracellular antigen labeling (optional steps)(1) Add antibody working solution and mix well.(2) Under dark conditions, incubate antibodies at appropriate temperature and time.7. Flow detection and analysis:(1) It is recommended to conduct flow cytometry testing immediately after dyeing is completed; If conditions are limited, please store in a dark place at 4 ℃ for testing, but it should not exceed 3 days.(2) It is recommended to test the number of cells up to one million levels as much as possible. If the number of cells is small, the number of cells tested can be adjusted to 100000 levels starting from the experiment. For cases where the cell yield is too low (just to the level of ten thousand), it may not be conducive to making a flow chart. Therefore, the cleaning frequency in step 5 (8) can be appropriately reduced.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. fluorescent dyes have quenching problems. Please try to avoid light during experimental operation to slow down fluorescence quenching. 3. click it edu buffer additive solution should be prepared and used immediately to ensure the best results. 4. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Cell proliferation detection (cell imaging flow universal)... Read More | Products content Box 1: Circularization reagentC666001Component16 TStorageC666001ASplint Oligo20 µL-20℃.Avoid freeze/thaw cycle. C666001B5×Splint Buffer T4250 µL-20℃.Avoid freeze/thaw cycle. C666001CDNA Ligase50 µL-20℃.Avoid freeze/thaw cycle. C666001DDigestion Products content Box 1: Circularization reagentC666001Component16 TStorageC666001ASplint Oligo20 µL-20℃.Avoid freeze/thaw cycle. C666001B5×Splint Buffer T4250 µL-20℃.Avoid freeze/thaw cycle. C666001CDNA Ligase50 µL-20℃.Avoid freeze/thaw cycle. C666001DDigestion Buffer20 µL-20℃.Avoid freeze/thaw cycle. C666001EDigestion Enzyme I70 µL-20℃.Avoid freeze/thaw cycle. C666001FDigestion Enzyme III25 µL-20℃.Avoid freeze/thaw cycle. Box 2: Magnetic Beads for DNA Purification and RecoveryC666001Component16 TStorageC666001GCMPure4×1.5 mL2-8℃Products IntroductionThe Cyclization Kit is a modular kit tailored for the MGI high-throughput sequencing platform. With this kit, PCR products after junction ligation can be prepared into single-stranded circular DNA libraries suitable for MGI sequencers. All reagents provided in the kit have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 (Cat. No. 12321D) is recommended.2. "Qubit" 3.0 Fluorescence Quantimeter (ThermoFisher, Cat. No. Q33216)3. Qubit" ssDNA Assay Kit (Invitrogen, Cat. No. Q10212)4. Anhydrous ethanol, EB (10 mM Tris-HCl, pH 8.0), NF Water (pH between 7.0 and 8.0).5. reaction tubes: low adsorption PCR tubes with 1.5 mIEP tubes are recommended: 5.Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and libraries. Pre-experiment Preparation and Important Notes 1. Sample preparation.PCR product: 2330 ng total (total amount when multiple PCR products are mixed) in a volume of 49 pL (if the volume of PCR product is insufficient, add NF Water to bring the total volume to 49 pl). -PCR product: Fragment size: The fragment peak is between 200-500 bp. -PCR product fragment size: Fragment peaks between 200-500 bp. -PCR product modification: Fixed sequences (with Index) for MGISEQ-2000, MGISEQ-200 and BGISEQ-500 sequencing platforms were added.2. Reagent preparation-Remove the corresponding reagents from the kit, centrifuge briefly, and place the enzyme mixture on ice until ready to use: buffers need to be dissolved at room temperature before use, then centrifuged with shaking and placed on ice until ready to use, and NF Water and EB are placed at room temperature until ready to use: "Please make up the mixture on ice:Precipitation may appear after the buffer in the kit is dissolved, the precipitation does not affect the function of the reagent, please shake and mix well until the precipitation disappears and then use. Schematic diagram of the cyclization process procedurecyclize 1. 1 wl of Splint Oligo was added to the 49JI PCR product. The product was denatured and incubated on a PCR instrument at 95°C for 3 min, then immediately transferred to an ice bath and allowed to stand for 2 min. 2. The reaction mixture was prepared on ice according to the following system. 3. Add 15ul of the above reaction mixture to 50µl of denatured DNA.4. Place the above PCR tubes on the PCR instrument under the following conditions Reaction. digest 1. Prepare the digestion reaction solution on ice according to the following system. 2. After the cyclization reaction, add 8l of digestion reaction solution directly to the cyclization system, mix well, centrifuge briefly and then place the PCR tube on the PCR instrument and react under the following conditions. 3. Purification was carried out immediately after the reaction.Purification of digestive products1. Remove CMPure at room temperature 30 minutes prior to use and mix well with shaking.2. Transfer the digested product to a 1.5 mIEP tube, pipette 340 pICMPure into the digested product, mix well by gently blowing 10 times with a pipette and incubate for 10 minutes at room temperature.3. Instantaneous centrifugation, place the EP tube on a magnetic rack and let stand for 5 minutes until the liquid is clear, pipette and discard the supernatant.4. Keep the EP tube fixed on a magnetic rack, add 250ul of freshly prepared 80% ethanol, let it stand at room temperature for 1 minute, then carefully discard the supernatant.5. Repeat step 4 once, try to suck up the liquid at the bottom of the tube: Note: Do not suck up the magnetic beads, so as not to affect the yield.6. Keep the EP tube fixed on the magnetic rack, open the cap and dry it at room temperature for 5-10 minutes.7. Remove the EP tube from the magnetic rack, add 35ul of EB or NF Water for DNA elution, pipette blow to mix and dissolve at room temperature for 10 min.8. Centrifuge instantaneously, place the EP tube on a magnetic rack and let stand for 2 minutes until the liquid is clarified, transfer the supernatant to a new EP tube. -Store at 20C and leave to prepare DNB... Read More | Inquire | Products contentNote: The amount of individual primers used is 1 µl, each N7-end primer can perform 10 DNA library constructs, and each kit can perform 240 DNA library constructs.Products IntroductionThis kit is a companion kit to the transposase-based Rapid DNA Library Construction Kit for Products contentNote: The amount of individual primers used is 1 µl, each N7-end primer can perform 10 DNA library constructs, and each kit can perform 240 DNA library constructs.Products IntroductionThis kit is a companion kit to the transposase-based Rapid DNA Library Construction Kit for Illumina platform library construction. Each kit contains one N5 primer and 24 N7 primers, which can be used to prepare 24 different single-ended Index libraries. All reagents provided in the kits have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The libraries can be used for sequencing on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Kangwei Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes; Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers. procedureFor the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol. Index N501 Primer for Illumina Index N901-N996 Primer for Illumina... Read More |