| Description | DescriptionCAR10 is a kit that contains a selection of 10 carbohydrates/sugars: Arabinose, Fructose, Galactose, Glucose, α-Lactose, Maltose, Mannose, Ribose, Sucrose and Xylose, which may be used for general research, as reagents or as reference compounds in analytical procedures | D-Lactate, typically present in the bloodstream at nanomolar concentrations, is produced by an intestinal source or via the methylglyoxal pathway. In mammals, D-Lactate metabolism requires D-Lactate hydrogenase and is metabolized slowly, thus an increase in blood concentration levels can lead to D-Lactate, typically present in the bloodstream at nanomolar concentrations, is produced by an intestinal source or via the methylglyoxal pathway. In mammals, D-Lactate metabolism requires D-Lactate hydrogenase and is metabolized slowly, thus an increase in blood concentration levels can lead to acidemia and acidosis. The severity of this D-lactic acidosis can be associated with neurotoxic symptoms. Significant D-Lactate accumulations in the body can also be related to impaired metabolism and excretion.D-Lactate Colorimetric Assay kit has been used to determine the stereospecificity of lactate produced.Suitability: Suitable for use with samples of serum, plasma, cells, culture and fermentation media.Principle: In this assay, D-Lactate is specifically oxidized by D-Lactate hydrogenase and generates a proportional colorimetric product measured at 450 nm. The useful concentration range in samples is 0.1-10 mM D-Lactate... Read More | Product content N665859Component50 TStorageN665859ABuffer DS30 mLRTN665859BBuffer GTL15 mLRTN665859CBuffer GL15 mLRTN665859DBuffer GW1 (concentrate)13 mLRTN665859EBuffer GW2 (concentrate)15 mLRTN665859FBuffer TE10 mLRTN665859GProteinase K2×1.25 mLRTN665859HRNase A (100 mg/mL)0.4 Product content N665859Component50 TStorageN665859ABuffer DS30 mLRTN665859BBuffer GTL15 mLRTN665859CBuffer GL15 mLRTN665859DBuffer GW1 (concentrate)13 mLRTN665859EBuffer GW2 (concentrate)15 mLRTN665859FBuffer TE10 mLRTN665859GProteinase K2×1.25 mLRTN665859HRNase A (100 mg/mL)0.4 mLRTN665859ISpin Columns DF With Collection Tubes50 EA2-8℃N665859JCentrifuge Tubes (L-1.5 mL)50 EART Product IntroductionThis kit is suitable for the effective purification of genomic DNA from formalin-fixed, paraffin-embedded tissues.The product uses specially optimized dewaxing agent and lysis solution to release DNA from formalin-fixed or tissue sectioned samples, which does not involve the organic reagent xylene and does not need to be operated overnight; the digested samples are incubated at higher temperatures to remove formalin cross-linking of the free DNA, which can effectively improve the yield and purity of DNA; the optimized buffer system allows the inhibitors in the lysis solution to be specifically bound to the adsorbent membrane, which can be effectively removed by a two-step rinsing step. The optimized buffer system enables the DNA in the lysate to specifically bind to the adsorbent membrane, and the inhibitor is effectively removed by a two-step rinsing step, and finally eluted with low-salt buffer or water to obtain high-purity DNA.Meanwhile, configured with a high-efficiency microsorbent column, the elution volume can be as low as 20 µL.The purified DNA can be directly used for PCR, Real-time PCR, SNP Genotyping, STR genotyping, second-generation sequencing and pharmacogenomics research.The molecular weight of DNA isolated from formalin-fixed, paraffin-embedded samples is usually lower than that of DNA from fresh or frozen samples.The degree of DNA fragmentation depends on the type of sample, the duration of storage, and the conditions of fixation.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. After obtaining the sample, fix the sample in 4%-10% formalin as soon as possible, the fixation time should be 14-24 hours, too long a period of time will easily lead to genome breakage, affecting the downstream experiments. If the formaldehyde fixation time is too long or the sample has been stored for too long (> 1 year), it will easily lead to DNA integrity damage and unable to amplify long fragments.2. Ensure that the sample is thoroughly dehydrated before embedding; residual formalin will inhibit Proteinase K.3. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.4. Before use, please check Buffer GTL, Buffer GL and Buffer DS for any crystallization or precipitation. If there is any crystallization or precipitation, please re-dissolve Buffer GTL, Buffer GL and Buffer DS at 56℃ in a water bath.5. Preheat the water bath or thermostatic mixer to 56°C and keep the centrifuge at 25°C before starting the experiment.6. If downstream experiments are needed to reduce the low frequency of C>T:G>A transitions (artificial mutations) that occur to minimize the risk of false positives, 7 µL of UNG (1 U/uL) can be added after 1 hour of incubation at 90°C.Operation steps1. Sample processing:1a. Paraffin-embedded samples: Trim off excess paraffin from the tissue block with a scalpel to expose the tissue and then cut into 5-10µm slices. Take about 1×1cm2 slices (about 4-5 slices in total) and place them in a centrifuge tube (provided), add 160µL Buffer DS, vortex and shake for 10 seconds, then add 180µL Buffer GTL and 20µL Proteinase K, vortex and shake for 10 seconds. centrifuge the samples at 12,000rpm for 1 minute at 25℃.Note: 1) If the surface of the sample has been exposed to air, discard the 2-3 pieces that have been exposed to air and do not use them.2) DS will solidify below 18°C, and if it does it does not affect the following experiments.1b. Sample in formalin and other fixative: take about 20mg of sample, cut it into small pieces, place it in a centrifuge tube, add 500µL of 10mM PBS (PH7.4), vortex shaking, centrifuge at 12,000rpm for 1minute, discard the supernatant, and repeat 3 times. Add 180 µL Buffer GTL, 20 µL Proteinase K, vortex shaking to mix.2.56°C for 1 hour until the sample is completely dissolved. incubate at 90°C for 1 hour. centrifuge at 12,000 rpm, 25°C for 1 minute, and carefully pipette the lower aqueous phase (~180 µL) along the wall of the tube into a new centrifuge tube, trying to avoid aspirating the bottom precipitate and the upper layer of the wax solution.Note: 1) Samples can be left at room temperature after incubation at 56°C until the temperature of the water or dry bath reaches 90°C before placing the samples at 90°CIncubation.2) Optional step: add 7µL UNG (1U/µL), 50°C, 5min, no shaking. The purpose of this step is to minimize the risk of false positives by reducing the low-frequency occurrence of C>T:G>A transitions (artificial mutations) while effectively retaining the true occurrence of mutations.3. Optional step: If you need to remove RNA, you can lower the temperature of the sample to room temperature, then add 2µL of RNase A solution at a concentration of 100mg/mL, shake and mix well, and leave it at room temperature for 2 minutes.4. Add 20µL Proteinase K and incubate at 65℃, 450rpm for 15min.5. Add 200 µL of Buffer GL, mix well by vortexing and shaking, then add 200 µL of anhydrous ethanol and mix thoroughly by vortexing and shaking. Centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube.Note: 1) Mix well immediately after adding Buffer GL and anhydrous ethanol.2) The addition of Buffer GL and anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.3) If more than one sample needs to be manipulated, the Buffer GL and anhydrous ethanol can be pre-mixed and spiked.6. Add all the solution obtained in step 5 to the adsorption columns (Spin Columns DF) that have been loaded into the collection tube, centrifuge at 25℃, 12000rpm for 2 minutes, pour out the waste liquid in the collection tube, and put the adsorption columns back into the collection tube.7. Add 500µL of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.8. Add 500µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12000rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 8 can be repeated if further DNA purity is required.9.12 Centrifuge at 2000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions.10. Place the adsorption column in a new 1.5 mL collection tube, add 20-100 µL of Buffer TE or sterilized water to the middle of the adsorption column overhanging the column, let it stand at room temperature for 2-5 minutes, centrifuge it at 12,000 rpm for 1 minute, and collect the DNA solution.-20°C to preserve DNA.Note: 1) The pH value of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH value is 7.0-8.5, the pH value is lower than 7.0 when the elution efficiency is not high.2) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 10 can be re-spiked onto the adsorbent membrane and left at room temperature for 2 minutes and centrifuged at 12,000 rpm for 1 minute... Read More | Product contentS666146Component50 T200 TStorageS666146ABuffer GR25 mL120 mLRTS666146BBuffer GL25 mL120 mLRTS666146CBuffer GW1 (concentrate)13 mL52 mLRTS666146DBuffer GW2 (concentrate)15 mL75 mLRTS666146EBuffer GE15 mL60 mLRTS666146FProteinase K1.25 mL4×1.25 mLRTS666146GSpin Columns DS with Product contentS666146Component50 T200 TStorageS666146ABuffer GR25 mL120 mLRTS666146BBuffer GL25 mL120 mLRTS666146CBuffer GW1 (concentrate)13 mL52 mLRTS666146DBuffer GW2 (concentrate)15 mL75 mLRTS666146EBuffer GE15 mL60 mLRTS666146FProteinase K1.25 mL4×1.25 mLRTS666146GSpin Columns DS with Collection Tubes50 sets 200 setsRTS666146HCentrifuge Tubes (1.5 mL)50 EA200 EARTProductsThis kit provides a simple and rapid method for the isolation and purification of total DNA from buccal swab samples. The kit adopts a silica matrix membrane that can specifically bind DNA and a unique buffer system to adsorb DNA efficiently and specifically, and 0.5-3.5 µg of genomic DNA can be obtained from each swab, and the extracted DNA fragments are large, pure and of stable and reliable quality. It is suitable for enzyme digestion, PCR, library construction, Southern hybridization and other experiments.Self-contained reagent: anhydrous ethanol.Pre-experiment Preparation and Important Notes1. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.2. If precipitation is found in Buffer GL before use, dissolve Buffer GL in a 56°C water bath.3. All centrifugation steps can be performed at room temperature.4. Sampling: Use a buccal swab to wipe the inside of the mouth 6 times, dry for 2 hours and store. To ensure that the sample is not contaminated by food or drink, do not eat or drink for 30 minutes before sampling.Procedure1. The swab of the buccal swab was cut from the rod with scissors and placed in a 2mL centrifuge tube (supplied) and 400µL Buffer GR was added.Note: For genomic DNA without RNA contamination, add 4 µL of RNase A solution at a concentration of 100 mg/ml and shake to mix.2. Add 20 µL of Proteinase K and 400 µL of Buffer GL, immediately vortex and shake for 15 seconds and mix thoroughly.Note: Mix well immediately after adding Buffer GL; do not add Proteinase K directly to Buffer GL for use.3.56°C for 10 minutes and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.4. Add 400 µL of anhydrous ethanol, vortex and shake to mix thoroughly, and centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube.Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.5. Add the solution and precipitate obtained in the previous step to the Spin Columns DS in two batches of up to 700 µL at a time into the collection tube. centrifuge the column at 12,000 rpm (∼13,400 × g) for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.6. Add 500 µL of Buffer GW1 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.7. Add 500 µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge the column at 12,000 rpm for 3 minutes, pour off the waste liquid in the collection tube, and put the column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 1 minute and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new 1.5 mL centrifuge tube, add 50 µL of Buffer GE or sterilized water to the middle of the adsorption column overhanging the column, let stand at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store at -20℃.Attention:(1) If the downstream experiment is sensitive to pH or EDTA, it can be eluted with sterilized water. The pH value of the eluent has a great influence on the elution efficiency. If the eluent is made of water, the pH value should be 7.0-8.5 (the pH value of water can be adjusted to this range by using NaOH), and the elution efficiency is not high when the pH value is lower than 7.0.2) For long-term storage, it is recommended to elute with Buffer GE and store at -20°C... Read More | Inquire |