| Description | Products contentProducts IntroductionThis kit is suitable for simple, rapid and efficient isolation and purification of DNA/RNA from whole blood, tissue homogenates, swabs, serum, plasma and other cell-free body fluids, etc. The unique buffer system enables the viral nucleic acids in the lysate to Products contentProducts IntroductionThis kit is suitable for simple, rapid and efficient isolation and purification of DNA/RNA from whole blood, tissue homogenates, swabs, serum, plasma and other cell-free body fluids, etc. The unique buffer system enables the viral nucleic acids in the lysate to bind to the silica gel centrifugal adsorbent columns in a highly efficient manner, and the viral nucleic acids obtained are of high purity and stable quality, free of protein, nuclease and other impurities, and can be used in a variety of routine operations, including PCR, fluorescence quantitative PCR and other experiments. It can be used for a variety of routine operations, including PCR, fluorescence quantitative PCR and other experiments.Bring your own instrumentsThermostatic mixer.Pre-experiment Preparation and Important Notes1. Read these instructions carefully before experimenting.2. If Proteinase K is to be stored for a long period of time, please keep it at -20℃.3. Check Buffer RLC for crystallization or precipitation prior to use, and if crystallization or precipitation occurs, redissolve Buffer RLC in a 56°C water bath.4. Pre-treatment of tissue samples: Take 20 mg of tissue samples into 1.5 mL centrifuge tubes (self-provided), add 500 µL of Buffer RLC, and after the tissue homogenizer breaks up, centrifuge the samples for 1 minute at 12,000 rpm (~13,400×g), and take 200 µL of supernatant as samples. procedure1. Take a 1.5 mL centrifuge tube (provided), add 500 µL of Buffer RLC, 200 µL of sample, 20 µL of Proteinase K, vortex for 5 s, and then place it in a thermostatic mixer at 1200 rpm for 10 min at room temperature. Note: For wet swab samples, 200 µL of sample was taken after sufficiently shaking and mixing. Note: For wet swabs, 200 µL was taken from the sample after it was soaked in 400 µL of saline, shaken and mixed thoroughly for 5 minutes, and then centrifuged at 12,000 rpm for 1 minute, and 200 µL was taken for extraction.2. Instantly remove the centrifuge tube and add the solution from step 1 to the Spin Columns DM in the collection tube. centrifuge at 12,000 rpm (~13,400 x g) for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.3. Add 500 µL of Buffer PGWT to the adsorbent column, centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.4. Add 500 µL of Buffer GWT2 to the adsorbent column, centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.5. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Place the adsorption column at room temperature for 2 minutes and allow to dry.6. Place the column in a new collection tube (RNase-Free Centrifuge Tube), add 40-100 µL of RNase-Free Water to the center of the column membrane, let it stand at room temperature for 2 minutes, and then centrifuge at 12,000 rpm for 1 minute to collect the nucleic acid solution. Store at -80℃ for a long time... Read More | DescriptionUse in combination with the KitAlysis Bench Top Inertion Box (Z742064) or a glove box/glove bag to provide inert atmosphere for kit set-up.Designed to be used with KitAlysis High-Throughput Screening Kits.Components:24-Well Reaction BlockTorque ScrewdriverSmall screwdriver to easily DescriptionUse in combination with the KitAlysis Bench Top Inertion Box (Z742064) or a glove box/glove bag to provide inert atmosphere for kit set-up.Designed to be used with KitAlysis High-Throughput Screening Kits.Components:24-Well Reaction BlockTorque ScrewdriverSmall screwdriver to easily remove torqued screws after reaction is complete.10 Reaction Block Replacement Screws... Read More | DescriptionProvides an inert environment to run oxygen sensitive cross-coupling reactions in a laboratory fume hood.Designed to be used with KitAlysis High-Throughput Screening Kits and KitAlysis 24-Well Reaction Block | Products R669890Component50 TStorageR669890ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669890B10×Reaction Buffer1mL-20℃. Avoid freeze/thaw cycle.R669890CBuffer RL35 mLRTR669890DBuffer RW140 mLRTR669890EBuffer RW2 (concentrate)11 mLRTR669890FRNase-Free Water10 mLRTR669890GSpin Products R669890Component50 TStorageR669890ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669890B10×Reaction Buffer1mL-20℃. Avoid freeze/thaw cycle.R669890CBuffer RL35 mLRTR669890DBuffer RW140 mLRTR669890EBuffer RW2 (concentrate)11 mLRTR669890FRNase-Free Water10 mLRTR669890GSpin Columns FL with Collection Tubes50 setsRTR669890HSpin Columns RM with Collection Tubes50 setsRTR669890IRNase-Free Centrifuge Tubes (1.5 mL)100 EART ProductsThis kit adopts centrifugal adsorption columns with high efficiency and specificbinding of nucleic acids and unique buffer system, which can rapidly extract totalRNA from bacteria or cultured animal cells.The reaction can be completed in 30-40minutes, and the extracted total RNA is extremely pure and free of protein and othercontaminants, which is suitable for RT-PCR, Real-Time RT-PCR, microarray analysis,in vitro translation and other experiments. Self-contained reagents: Lysozyme, β-mercaptoethanol, anhydrous ethanol (freshlyopened or for RNA extraction). Pre-experiment Preparation and Important Notes 1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination. 2) RNase-free water should be used to prepare the solution. 3) Operators wear disposable masks and gloves, and change gloves diligently duringthe experiment. 2. Add β-mercaptoethanol to Buffer RL before use to reach a final concentrationof 1%, e.g., add 10 µl of β-mercaptoethanol to 1 ml of Buffer RL. Buffer RL withβ-mercaptoethanol can be stored at 4℃ for 1 month, if precipitation occurs, pleaseheat to dissolve and use.3. Anhydrous ethanol should be added to Buffer RW2 before first use according tothe instructions on the reagent bottle label. 4. All centrifugation steps are carried out at room temperature if not otherwisespecified, and all steps should be performed quickly. Procedure 1. Centrifuge at 12,000 rpm (~13,400 x g) at 4°C for 2 minutes to collect theorganisms (maximum volume of organisms should not exceed 1 x 109) and carefullyremove all supernatants. Note: Supernatants that leave residues can interfere with the subsequent digestionprocess. 2. Thoroughly resuspend the organisms with 100 µl of TE buffer containing Lysozymeand incubate at room temperature. The specific formulation and incubation time areas follows:/The final concentration of Lysozyme in TE bufferincubation timeG-germ400µg/ml3-5minG+germ3mg/ml5-10min 3. Add 350 µl of Buffer RL (check that β-mercaptoethanol has been added beforeuse), vortex and shake to mix (insoluble precipitate may appear in this step), addall of the solution and the precipitate to the filter columns (Spin Columns FL) thathave been loaded into the collection tubes, and centrifuge at 12,000 rpm for 2minutes. 4. Add 250 µl of anhydrous ethanol to the filtrate obtained in the previous stepand mix well (a precipitate may appear at this point). Transfer the resulting solution together with the precipitate to a Spin Columns RM packed in a collectiontube, centrifuge at 12,000 rpm for 1 min, discard the waste solution and put thecolumn back into the collection tube.5. Add 350 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for1min, discard the waste liquid and put the adsorbent column back into the collectiontube.6. Preparation of DNase I mixture: Take 52µl of RNase-Free Water, add 8µl of 10×Reaction Buffer and 20µl of DNase I (1U/µl) to it, mix well, and make a finalvolume of 80µl of reaction solution.7. Add 80µl of DNase I mixture directly to the adsorption column and incubate at20-30°C for 15 minutes.8. Add 350 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for1min, discard the waste liquid and put the adsorbent column back into the collectiontube.9. Add 500 µl of Buffer RW2 to the column (check that anhydrous ethanol is addedbefore use), centrifuge at 12,000 rpm for 1 min, and discard the waste solution.10. Repeat step 9.11. Place the adsorbent column back into the collection tube and centrifuge at 12,000rpm for 2 minutes. Note: The purpose of this step is to remove residual ethanol from the adsorptioncolumn; ethanol residue can interfere with subsequent enzymatic reactions (zymography, PCR, etc.).12. Load the adsorption column into a new RNase-Free collection tube, add 30-50 µl of RNase-Free Water to the middle of the adsorption membrane, leave it at roomtemperature for 1 minute, centrifuge at 12,000 rpm for 1 minute, collect the RNAsolution, and store the RNA at -70°C to prevent degradation. Note: 1) The volume of RNase-Free Water should not be less than 30 µl, too smallvolume affects the recovery rate. 2) If you want to increase the RNA yield, repeat step 12 with 30-50 µl of freshRNase-Free Water. If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 12 repeated... Read More | This kit combines efficient guanidine isothiocyanate lysis technology with silicon matrix membrane purification technology to efficiently extract total RNA from animal cells and tissues. The starting sample usually has a maximum of 30 mg of tissue or 1 x 107 cells. This reagent kit can also recover This kit combines efficient guanidine isothiocyanate lysis technology with silicon matrix membrane purification technology to efficiently extract total RNA from animal cells and tissues. The starting sample usually has a maximum of 30 mg of tissue or 1 x 107 cells. This reagent kit can also recover partially purified RNA, RNA obtained from in vitro transcription and enzymatic reactions. This reagent kit can extract and purify high-quality RNA with a molecular weight greater than 200 bases, with almost no DNA residue. If RNA experiments are to be conducted that are highly sensitive to trace amounts of DNA, residual DNA can be digested and removed on a column using DNase I without RNase. The extracted RNA can be used for downstream experiments such as RT-PCR, Northern Blot, Dot Blot, etc. R666020Component50 TStorageR666020ABuffer RL35 mLRTR666020BBuffer RW140 mLRTR666020CBuffer RW2 (concentrate)11 mLRTR666020DRNase-Free Water10 mLRTR666020ESpin Columns RM with Collection Tubes50 setsRTR666020FRNase-Free Centrifuge Tubes (1.5 mL)50 EART Self prepared reagents: β- Mercaptoethanol, anhydrous ethanol (newly opened or dedicated for RNA extraction).Preparation and important precautions before the experimentTo prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The extracted samples should avoid repeated freeze-thaw cycles, otherwise it will affect the quantity and quality of RNA extraction.3. Before use, please check if there is any crystallization or precipitation in the Buffer RL. It can be heated at 56 ℃ and re solved. Please add Buffer RL before use β- Mercaptoethanol, with a final concentration of 1%. Add 10 to 1ml Buffer RL µ L β- Mercaptoethanol. join β- The buffer RL room temperature of mercaptoethanol can be stored for one month.4. Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.6. If downstream experiments are highly sensitive to DNA, it is recommended to treat RNA with DNase I that does not contain RNase.Operation steps1. Sample processing1a organization: Grind the organization in liquid nitrogen. Add 600 to every 20-30 mg of tissue µ L Buffer RL (check if it is added before use) β- Mercaptoethanol), tissue sample less than 20 mg plus 350 µ Buffer RL. The sample volume shall not exceed one tenth of the buffer RL volume.1b Single layer culture of cells: The cells are directly lysed or processed into cell suspensions in a culture bottle, centrifuged to obtain cell precipitates, and the supernatant is discarded. 600 is added every 6-10 cm2 of culture area µ Buffer RL, less than 6 cm2, add 350 µ Blow buffer RL several times to fully crack it.1c cell suspension: Centrifuge at 12000 rpm (~13400 × g) for 1 minute to discard the supernatant and obtain cell precipitate. Add 600 cells every 5 × 106-1 × 107 cells µ Buffer RL, less than 5 × 106 cells added to 350 µ Blow buffer RL several times to fully crack it.Attention:1) Try to eliminate the cell culture medium as much as possible, as it may inhibit cell lysis and affect RNA production.2) Try to fully suspend and lyse the cells, otherwise it will affect RNA production.2. After the sample is fully lysed, it should be left at room temperature for 5 minutes to completely separate the protein nucleic acid complex.3. Centrifuge at 2000rpm for 2-5 minutes, take the supernatant and proceed to the next step.4. Add 1 volume (600) µ L or 350 µ l) Mix 70% ethanol (prepared without RNase water) well.Attention: Adding ethanol may cause precipitation and will not affect subsequent experiments.5. Add all the solution obtained in step 4 to the Spin Columns RM that has been loaded into the collection tube. If it is not possible to add all the solution to the adsorption column at once, please transfer it in two batches, centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube. Attention: The maximum loading capacity of the adsorption column is 100 µ g, do not overload, otherwise it will affect the yield and purity of RNA.6. Add 700 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column in the collection tube.Optional steps: If conducting RNA experiments that are highly sensitive to trace amounts of DNA, replace step 6 with the following steps.1) Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 15 seconds, discard the waste liquid, and place the adsorption column back into the recovery manifold.2) Preparation of DNase I mixture: Take 52 µ Add 8 RNase Free Water to it µ 10 x Reaction Buffer and 20 µ DNase I (1 U/ µ l) Mix well and prepare to a final volume of 80 µ The reaction solution of L.Attention: The above system is configured according to our company's DNase I reaction system. Please refer to the corresponding manual for other company products.3) Add 80 µ l of the prepared DNase I reaction solution directly to the adsorption column and incubate at 20-30 ℃ for 15 minutes.4) Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 15 seconds, discard the waste liquid, and place the adsorption column back into the recovery manifold.7. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.8. Repeat step 7. 9. Centrifuge at 12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).10. Place the adsorption column in a new RNase free centrifuge tube, and add 30-50 to the middle of the adsorption column in the air µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 10 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 10... Read More |