| Description | M666110 Component 96 T Storage M666110A Buffer WSL 40 mL RT M666110B Buffer MSL 40 mL RT M666110C Buffer CW1 (concentrate) 90 mL RT M666110D Buffer GW1 (concentrate) 40 mL RT M666110E Buffer GW2 (concentrate) 50 mL RT M666110F Buffer EB 30 mL RT M666110G Proteinase K 4×1.25 mL RT M666110H M666110 Component 96 T Storage M666110A Buffer WSL 40 mL RT M666110B Buffer MSL 40 mL RT M666110C Buffer CW1 (concentrate) 90 mL RT M666110D Buffer GW1 (concentrate) 40 mL RT M666110E Buffer GW2 (concentrate) 50 mL RT M666110F Buffer EB 30 mL RT M666110G Proteinase K 4×1.25 mL RT M666110H Magbeads V3 2×1 mL RTProduct Introduction:The reagent kit provides a simple, fast, and efficient method for extracting genomic DNA from blood samples. In the presence of high salt, DNA binds to the surface of silica coated Magheads. After rinsing, high-purity DNA is eluted in Buffer EB or deionized water. The purified DNA has good purity (A260/280 ratio between 1.7-1.9) and high integrity (>15 kb), and can be used for downstream experiments such as second-generation sequencing, quantitative PCR, and chip detection.Self provided instruments and reagents1) Constant temperature mixer2) 2/15 ml magnetic frame3) 32 channel nucleic acid extractor4) 96 channel nucleic acid extractor5) 96 DW Plate6) 8 channel Comb7) Spin tips pack8) Anhydrous ethanolPreparation and important precautions before the experiment1.Before the first use, add anhydrous ethanol to Buffer CW1, Buffer GW1, and Buffer GW2 according to the label of the reagent bottle and mark them properly.2.Magheads are strictly prohibited from freezing or centrifugation. Freezing and centrifugation may cause irreversible damage to Magheads.Operation stepsI. Manual single tube operation1. Use punching forceps to take 1 blood spot with a diameter of 6 mm or 4 blood spots with a diameter of 3 mm (depending on the actual situation) from the blood spot and place them in a 2.0 mL centrifuge tube.2. Add 40 to the centrifuge tube µ L Protein K and 300 µ L Buffer WSL, then place the centrifuge tube on a constant temperature mixer at 75 ℃ and 1200 rpm, shake and crack for 45 minutes to form Lysate. Remove the centrifuge tube from the constant temperature mixer, centrifuge briefly, and take the supernatant.Attention: If there is no constant temperature mixer, vortex the centrifuge tube for 10 seconds and incubate it in a 75 ℃ water bath for 30 minutes. During this period, vortex every 10 minutes for 10 seconds.3. Suck the supernatant into a new 2.0 mL centrifuge tube and add 300 µ L Buffer MSL, 300 µ L isopropanol and 20 µ L Magheads V3. Afterwards, place the centrifuge tube on a constant temperature mixer at 25 ℃ and 1600 rpm, shake and crack for 15 minutes, or invert the centrifuge tube and mix continuously for 15 minutes.4. Place the centrifuge tube on a magnetic stand and let it stand for 1 minute. After Magheads are completely adsorbed on the side wall of the centrifuge tube, discard the solution thoroughly (keep the centrifuge tube fixed on the magnetic stand).5. Remove the centrifuge tube from the magnetic frame and add 900 µ L Buffer CW1 (please check if anhydrous ethanol has been added before use), vortex point shake for 1 minute or vortex shake for 5 seconds, and then place it on a constant temperature mixer at 25 ℃ and 1600 rpm to shake and mix for 2 minutes (ensure that Magheads are in a mixed state during the shaking process). Afterwards, place the centrifuge tube on a magnetic stand and let it stand for 1 minute. After Magheads are completely adsorbed on the side wall of the centrifuge tube, gently invert the magnetic stand and wash the impurities on the centrifuge tube cover to completely discard the solution (keep the centrifuge tube fixed on the magnetic stand).6. Remove the centrifuge tube from the magnetic frame and add 500 µ L Buffer GW1 (please check if anhydrous ethanol has been added before use), vortex point shake for 1 minute or vortex shake for 5 seconds, and then place it on a constant temperature mixer at 25 ℃ and 1600 rpm to shake and mix for 2 minutes (ensure that Magheads are in a mixed state during the shaking process). Afterwards, place the centrifuge tube on a magnetic stand and let it stand for 1 minute. After Magheads are completely adsorbed on the side wall of the centrifuge tube, gently invert the magnetic stand and wash the impurities on the centrifuge tube cover to completely discard the solution (keep the centrifuge tube fixed on the magnetic stand).7. Remove the centrifuge tube from the magnetic frame and add 900 µ L Buffer GW2 (please check if anhydrous ethanol has been added before use), vortex point shake for 1 minute or vortex shake for 5 seconds, then place it on a constant temperature mixer at 25 ℃ and 1600 rpm, shake and mix for 2 minutes (ensure that Magheads are in a mixed state during the shaking process). Afterwards, place the centrifuge tube on a magnetic stand and let it stand for 1 minute. After Magheads are completely adsorbed on the side wall of the centrifuge tube, gently invert the magnetic stand and wash the impurities on the centrifuge tube cover to completely discard the solution (keep the centrifuge tube fixed on the magnetic stand).8. Remove the centrifuge tube from the magnetic frame and add 300 µ After shaking with 75% ethanol for 1 minute or 5 seconds, place the mixture on a constant temperature mixer at 25 ℃ and 1600 rpm for 2 minutes (ensure that the Magheads are in a mixed state during the shaking process). Afterwards, place the centrifuge tube on a magnetic stand and let it stand for 1 minute. After Magheads are completely adsorbed on the side wall of the centrifuge tube, gently invert the magnetic stand and wash the impurities on the centrifuge tube cover to completely discard the solution (keep the centrifuge tube fixed on the magnetic stand).9. Keep the centrifuge tube fixed on the magnetic frame, use a pipette to further remove the solution from the bottom and cover of the centrifuge tube, and then leave it at room temperature for 5-10 minutes to allow the ethanol to evaporate completely.10. Remove the centrifuge tube from the magnetic frame and add 50-200 µ L Buffer EB. Vortex oscillation causes the magnetic beads to completely suspend in the eluent and then place them on a constant temperature mixer at 56 ℃ and 1600 rpm for 10 minutes of shaking and elution, or incubate the centrifuge tube in a 56 ℃ water bath for 10 minutes, with vortex oscillation every 3 minutes for 10 seconds.11. Place the centrifuge tube on a magnetic stand and let it stand for 2 minutes. After Magheads are completely adsorbed on the side wall of the centrifuge tube, transfer the eluent to a new centrifuge tube using a pipette and store at -20 ℃ for later use.II. Matching with CWE21001. Use punching forceps to take 1 blood spot with a diameter of 6 mm or 4 blood spots with a diameter of 3 mm (depending on the actual situation) from the blood spot and place them in a 2.0 mL centrifuge tube.2. Add 40 to the centrifuge tube µ L Protein K and 300 µ L Buffer WSL, then place the centrifuge tube on a constant temperature mixer at 75 ℃ and 1200 rpm, shake and crack for 45 minutes to form Lysate.3. Add the corresponding reagents to the 96DW deep well plate according to the table below. Position Reagent 1&7 Colume Lysate: All Buffer MSL: 300 µL isopropanol:300 µL Magbeads V3: 20 µL 2&8 Colume Buffer CW1: 900 µL 3&9 Colume Buffer GW1: 500 µL 4& 10 Colume Buffer GW2: 900 µL 5& 11 Colume 75%ethanol: 300 µL 6& 12 Colume Buffer EB: 70 µL4.Place the deep well plate and magnetic sleeve that have been added to the reagent at the corresponding positions of CWE2100/CWE3200, run the blood slide extraction program, and after about 40 minutes, the program ends. Remove the deep well plate and magnetic sleeve.5.Transfer the elution products from columns 6 and 12 of the deep well plate to a 1.5 mL centrifuge tube for low-temperature storage.III. Matching with CWE9601. Use punching forceps to take 1 blood spot with a diameter of 6 mm or 4 blood spots with a diameter of 3 mm (depending on the actual situation) from the blood spot and place them in a 2.0 mL centrifuge tube.2. Add 40 to the centrifuge tube µ L Protein K and 300 µ L Buffer WSL, then place the centrifuge tube on a constant temperature mixer at 75 ℃ and 1200 rpm, shake and crack for 45 minutes to form Lysate.3. Add the corresponding reagents to the 96DW deep well plate according to the table below Position Reagent Plate 1 Lysate: All Buffer MSL: 300 µL isopropanol :300 µL Magbeads V3: 20 µL Plate 2 Buffer CW1: 900 µL Plate 3 Buffer GW1: 500 µL Plate 4 Buffer GW2: 900 µL Plate 5 75% ethanol : 300 µL Plate 6 Buffer EB: 70 µL4. Place the deep well plate and magnetic sleeve that have been added to the reagent at the corresponding positions on CWE960, run the blood slide extraction program, and after about 40 minutes, the program ends. Remove the deep well plate and magnetic sleeve.5. Transfer the elution products from Plate 6 to a 1.5 mL centrifuge tube for low-temperature storage... Read More | Inquire | Product content C665709Component50 TStorageC665709ABuffer CL45 mLRTC665709BBuffer CB (concentrate)60 mLRTC665709CBuffer GW1 (concentrate)13 mLRTC665709DBuffer GW2 (concentrate)15 mLRTC665709EBuffer EBL10 mLRTC665709FProteinase K100 mgRTC665709GProteinase K Storage Buffer5 mLRTC665709HSpin Columns DFProduct content C665709Component50 TStorageC665709ABuffer CL45 mLRTC665709BBuffer CB (concentrate)60 mLRTC665709CBuffer GW1 (concentrate)13 mLRTC665709DBuffer GW2 (concentrate)15 mLRTC665709EBuffer EBL10 mLRTC665709FProteinase K100 mgRTC665709GProteinase K Storage Buffer5 mLRTC665709HSpin Columns DF with Collection Tubes50 EA2-8℃C665709ICentrifuge Tubes (L-1.5 mL)50 EART Product IntroductionThis kit is suitable for the extraction of free DNA from fresh or frozen serum, plasma, lymph fluid and other cell-free body fluids.This kit adopts centrifugal adsorption columns that can specifically bind nucleic acids and a unique buffer system.After the sample is lysed, the free DNA binds to the silica gel membrane under high salt conditions, and the free DNA elutes from the silica gel membrane at low salt and high pH. The product can handle liquid samples of 0.1-1 ml, and the elution volume of the configured high-efficiency micro adsorption column can be as low as 20 µl. The purified DNA is of high yield and quality, with maximum removal of proteins, pigments, lipids, and other inhibitors, and the rate of free DNA yield is highly dependent on the type of samples, storage conditions, time, and inter-individual variations. The quality of free DNA obtained from purification is stable and reliable, and can be directly used in molecular biology experiments such as PCR, fluorescence quantitative PCR and second generation sequencing.Self-contained reagents: anhydrous ethanol, isopropanol.Pre-experiment Preparation and Important NotesAdd 5 ml of Proteinase K Storage Buffer to Proteinase K to dissolve it and store it at -20℃. Do not leave the prepared Proteinase K at room temperature for a long time.Repeated freezing and thawing of the sample should be avoided, as this can lead to a decrease in extraction.This kit can extract 0.1-1 ml of liquid samples.Before use, please check Buffer CL, Buffer CB for crystallization or precipitation, if there is any crystallization or precipitation, please re-dissolve Buffer CL, Buffer CB by incubation at 56℃ in a water bath.Before first use isopropyl alcohol should be added to Buffer CB according to the instructions on the reagent bottle label, mixed well, and labeled on the reagent bottle label.Before the first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle, mixed well, and labeled on the label of the reagent bottle.Preheat the water bath to 60°C before starting the experiment.The elution buffer Buffer EBL can be preheated to 60°C and used.Operation stepsAdd 20 µl of Proteinase K to the centrifuge tube (supplied).Add 200 µl of serum/plasma sample.Note: When the sample volume exceeds 200 µl, please increase the amount of Proteinase K, Buffer CL and Buffer CB reagents in equal proportions, and the specific amount of reagents added can be referred to the attached table.3. Add 160 µl Buffer CL, mix upside down and shake vigorously for at least 30 seconds.4. Incubate at 60°C for 30 minutes, during which time mixing was inverted several times.Note: Incubation of 200µl serum/plasma samples at 60°C for 10-15 minutes is sufficient.Add 360 µl of Buffer CB (check for addition of isopropanol before use) and shake until thoroughly mixed.Ice bath for 5 minutes and centrifuge briefly to concentrate the liquid on the walls and wall caps to the bottom of the tube.Add all of the solution obtained in step 6 to the adsorption columns (Spin Columns DF) that have been loaded into the collection tubes, and if the solution cannot be added all at once, it can be transferred in several times. centrifuge the columns at 12,000 rpm for 1 minute, pour off the waste solution from the collection tubes, and put the columns back into the collection tubes.Add 500µl of Buffer GW1 to the adsorbent column (check that anhydrous ethanol is added before use),centrifuge the column at 12,000rpm for 30 seconds, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.Add 750 µl Buffer GW2 to the adsorbent column (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 30 seconds, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.10. Add 750 µl of anhydrous ethanol to the adsorbent column and centrifuge at 12,000 rpm for 30 s. Pour off the waste liquid in the collection tube and put the adsorbent column back into the collection tube.11. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with the subsequent enzymatic reaction.12. Place the adsorption column in a new centrifuge tube, add 20-100 µl Buffer EBL or sterilized water to the middle part of the adsorption column overhanging the column, leave it at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20℃.Note: 1) If the downstream experiment is sensitive to pH, you can use sterilized water for elution. The pH value of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH value is 7.0-8.5 (you can use NaOH to adjust the pH value of water to this range), and the elution efficiency is not high when the pH value is lower than 7.0.2) Preheat the elution buffer BufferEBL to 60℃ and use it, and incubate it at room temperature for 5 minutes before centrifugation to increase the yield.3) If the final concentration of DNA is to be increased, the resulting solution can be reintroduced into the adsorption column and left at room temperature for 2-5 minutes and centrifuged at 12,000 rpm for 1 minute.4) Because DNA preserved in water will be affected by acidic hydrolysis, for long-term storage, it is recommended to elute it with Buffer EBL and store it at -20℃.Table: Recommended reagent additions for different sample sizes... Read More | Inquire | Product content: Component S665549 50 preps Buffer SW 60 ml Buffer SL 60 ml Buffer GL 50 ml Buffer GW1(concentrate) 2X13 ml Buffer GW2(concentrate) 15 ml Buffer GE 15 ml Spin Columns DM 50 with Collection Tubes 50Product IntroductionThis kit is suitable for Product content: Component S665549 50 preps Buffer SW 60 ml Buffer SL 60 ml Buffer GL 50 ml Buffer GW1(concentrate) 2X13 ml Buffer GW2(concentrate) 15 ml Buffer GE 15 ml Spin Columns DM 50 with Collection Tubes 50Product IntroductionThis kit is suitable for extracting total DNA from fecal samples, including the total DNA of cells, bacteria, parasites, and viruses in the samples, as well as samples containing high concentrations of PCR reaction inhibitors. This product can process up to 300 mg of fecal samples and purify to obtain mainly 20-30 kb DNA fragments. The purification process does not require toxic solvents such as phenol or chloroform, and does not require ethanol precipitation. High purity DNA can be obtained within one hour. This reagent kit adopts a unique buffering system to efficiently bind DNA from the lysis solution to the adsorption column. At the same time, protein impurities and other organic compounds that inhibit downstream reactions in feces can flow through the membrane. Inhibitors of PCR and enzyme reactions, as well as residual impurities, can be effectively removed through two washing steps. Finally, high-purity DNA can be obtained by washing with low salt buffer or water. The purified DNA can be directly used for downstream experiments such as enzyme digestion, PCR, Real Time PCR, library construction, Southern Blot, and molecular labeling.Preparation and important precautions before the experiment1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.Before the first use, anhydrous ethanol should be added to Buffer GW1 and GW2 according to the instructions on the reagent bottle label.3. Before use, please check whether there is crystallization or precipitation in Buffer SL and Buffer GL. If there is crystallization or precipitation, please dissolve Buffer SL and Buffer GL again in a 56 ℃ water bath.4. If downstream experiments are sensitive to RNA contamination, 4 can be added after adding Buffer SL µ RNase A of DNase Free (100 mg/ml) is not provided in this kit. If needed, it can be ordered separately from our company, item number: S665549Operation steps1. Take a fecal sample of 100-300 mg and place it in a centrifuge tube (provided by oneself).2. Add 1 ml of Buffer SW and vortex for 3-5 minutes to evenly disperse the sample in the solution. Centrifuge at 12000 rpm (~13400 × g) for 1 minute and discard the supernatant.3. Add 1 ml of Buffer SL and vortex for 3-5 minutes to evenly disperse the sample in the solution. Take a water bath at 65 ℃ for 20 minutes and vortex for 15 seconds every 5 minutes. Note: To remove RNA, add 4 after completing the above steps µ RNase A solution (product number: CW0601S) with a concentration of 100 mg/ml, shake well and let stand at room temperature for 5-10 minutes.4.Centrifuge at 2000 rpm for 3 minutes and transfer the supernatant to a new centrifuge tube (provided by oneself).5. Add an equal volume of Buffer GL to the supernatant, invert and mix 15-25 times, and leave on ice for 5 minutes. Centrifuge at 12000 rpm for 5 minutes. Attention: At this time, the liquid may be in a transparent or turbid state, which does not affect the experiment. 6. Add the supernatant obtained in step 5 to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. 8. Repeat step 7.9. Add 500 to the adsorption column µ Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.10.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self provided) and add 50-100 drops of suspended droplets to the middle of the adsorption column µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Note: 1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency will be reduced2) Incubating at room temperature for 5 minutes before centrifugation can increase yield.3) Use an additional 50-100 µ Further washing with buffer GE or sterilized water can increase yield.4) If you want to increase the final concentration of DNA, you can add the DNA eluent obtained in step 11 back onto the adsorption membrane and repeat step 11; It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with buffer GE or sterilized water.5) DNA stored in water can be affected by acidic hydrolysis. If long-term storage is required, it is recommended to elute with Buffer GE and store at -20 ℃.6) The residual trace PCR inhibitors in the genomic DNA template may have adverse effects on the PCR reaction, which can be solved by diluting DNA by 2-10 times... Read More |