| Description | DescriptionCobalt is a transition metal that serves as a trace dietary mineral for all multicellular organisms. Cobalt is an important cofactor for the Vitamin B12class of compounds where it occupies the center of the vitamin B12corrin ring. Cobalt can also be coordinated in the active site of the DescriptionCobalt is a transition metal that serves as a trace dietary mineral for all multicellular organisms. Cobalt is an important cofactor for the Vitamin B12class of compounds where it occupies the center of the vitamin B12corrin ring. Cobalt can also be coordinated in the active site of the non-corrin containing metalloenzyme methionine aminopeptidase.Suitability: Suitable for quantitating cobalt concentrations in a variety of samplesPrinciple: The Cobalt Assay kit provides a simple and direct procedure for measuring cobalt in a variety of samples. In this assay, cobalt reacts with 2-mercaptoethanol under basic conditions to form a complex with a strong absorbance at 475 nm. Interference from the metal ions Fe2+, Cu2+, Ni2+, Zn2+, and Mn2+is <10% at this wavelength. This assay gives a linear range of 10-50 nmoles of cobalt.}Preparation instructionsSuitable for quantitating cobalt concentrations in a variety of samplesPrincipleThe Cobalt Assay kit provides a simple and direct procedure for measuring cobalt in a variety of samples. In this assay, cobalt reacts with 2-mercaptoethanol under basic conditions to form a complex with a strong absorbance at 475 nm. Interference... Read More | Alanine Aminotransferase (ALT), also known as serum glutamic-pyruvic transaminase (SGPT), is a pyridoxal-phosphate-dependent enzyme that catalyzes the reversible transfer of an amino group from alanine to α-ketoglutarate, generating pyruvate and glutamate. ALT is found primarily in liver and Alanine Aminotransferase (ALT), also known as serum glutamic-pyruvic transaminase (SGPT), is a pyridoxal-phosphate-dependent enzyme that catalyzes the reversible transfer of an amino group from alanine to α-ketoglutarate, generating pyruvate and glutamate. ALT is found primarily in liver and serum, but occurs in other tissues as well. Hepatocellular injury often results in an increase of serum ALT levels and serum ALT levels can be used as a marker for liver injury.ALT Activity Assay kit has been used to determine the activity of alanine aminotransferase (ALT) in serum samples... Read More | Inquire | Products contentNote: The amount of individual primers used is 1 µl, each N7-end primer can perform 10 DNA library constructs, and each kit can perform 240 DNA library constructs.Products IntroductionThis kit is a companion kit to the transposase-based Rapid DNA Library Construction Kit for Products contentNote: The amount of individual primers used is 1 µl, each N7-end primer can perform 10 DNA library constructs, and each kit can perform 240 DNA library constructs.Products IntroductionThis kit is a companion kit to the transposase-based Rapid DNA Library Construction Kit for Illumina platform library construction. Each kit contains one N5 primer and 24 N7 primers, which can be used to prepare 24 different single-ended Index libraries. All reagents provided in the kits have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The libraries can be used for sequencing on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Kangwei Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes; Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers. procedureFor the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol. Index N501 Primer for Illumina Index N901-N996 Primer for Illumina... Read More | Product Content R669990Component50 TStorageR669990ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669990B10×Reaction Buffer1 mL-20℃. Avoid freeze/thaw cycle.R669990CBuffer RL35 mLRTR669990DBuffer RW135 mLRTR669990EBuffer RW2 (concentrate)11 mLRTR669990FRNase-Free Water10 Product Content R669990Component50 TStorageR669990ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669990B10×Reaction Buffer1 mL-20℃. Avoid freeze/thaw cycle.R669990CBuffer RL35 mLRTR669990DBuffer RW135 mLRTR669990EBuffer RW2 (concentrate)11 mLRTR669990FRNase-Free Water10 mLRTR669990GSpin Columns RM with Collection Tubes50 setsRTR669990HRNase-Free Centrifuge Tubes (1.5 mL)50 EART ProductsThis kit combines highly efficient guanidine isothiocyanate cleavage technology with silica matrix membrane purification for the efficient extraction of total RNA from animal cells and tissues, typically up to 30 mg of tissue or 1x107 cells as a starting sample. The kit also allows recovery of incompletely purified RNA, in vitro transcription and RNA from enzymatic reactions. high quality RNA with molecular weights greater than 200 bases can be extracted and purified using the kit with virtually no DNA residue. If RNA experiments that are very sensitive to trace DNA are to be performed, residual DNA can be removed by on-column digestion using RNase-free DNase. The extracted RNA can be used in downstream experiments such as RT-PCR, Nothern Blot and Dot Blot. Self-contained reagents: β-mercaptoethanol, anhydrous ethanol (freshly opened or for RNA extraction).Pre-experiment Preparation and Important Notes1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination.2) RNase-free water should be used to prepare the solution.(3) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.2. Avoid repeated freezing and thawing of the extracted samples, otherwise it will affect the amount and quality of RNA extraction.3. Please add β-mercaptoethanol to Buffer RL before use, add 10µl of β-mercaptoethanol to 1ml of Buffer RL. Buffer RL with β-mercaptoethanol can be stored for 1 month at room temperature.4. Anhydrous ethanol should be added to Buffer RW2 before first use according to the instructions on the reagent bottle label.5. Buffer RL may be heated at 56°C to dissolve if precipitation occurs and then left at room temperature.All centrifugation steps are performed at room temperature and all maneuvers are performed quickly.Procedure1. Sample handling1a Tissue: Grind tissue in liquid nitrogen. Add 600 µl Buffer RL for every 20-30 mg of tissue (check for addition of β-mercaptoethanol before use), and 350 µl Buffer RL for tissue samples of less than 20 mg. Sample volume is not to exceed one-tenth of the Buffer RL volume.1b Cells in monolayer culture: Lysed or processed into cell suspension directly in culture flask, centrifuged to obtain cell precipitate, discarded the supernatant, added 600µl Buffer RL for every 6-10 cm2 of culture area, 350µl Buffer RL for less than 6cm2, and blown several times repeatedly to make the cells lysed sufficiently.1c Cell suspension: centrifuge at 12,000 rpm (~13,400 × g) for 1 min and discard the supernatant to obtain the cell precipitate. Add 600 µl Buffer RL for every 5×106-1×107 cells, and 350 µl Buffer RL for less than 5×106 cells, and blow several times repeatedly to fully lysate.Note: 1) Try to get rid of the cell culture medium, which may inhibit cell lysis affecting RNA yield.2) Try to keep the cells well suspended and well lysed, otherwise RNA yield is affected.2. After the sample is fully lysed, leave it at room temperature for 5 minutes to allow complete separation of the protein-nucleic acid complex.3. Centrifuge at 12,000 rpm for 2-5 min and remove the supernatant for the following operations.4. Add 1x volume (600µl or 350µl) of 70% ethanol (prepared without RNase water) to the solution obtained in step 3 and mix well.Note: The addition of ethanol may produce a precipitate that will not affect subsequent experiments.5. Add all of the solution obtained in the previous step to the Spin Columns RM in the collection tube. If you cannot add all of the solution to the column at once, transfer it in two passes, centrifuge at 12,000 rpm for 1 minute, and discard the waste solution. Place the column back into the collection tube.Note: The maximum loading capacity of the adsorption column is 100µg, do not overload as this will affect the yield and purity of the RNA.6. Add 350 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, discard the waste liquid and put the adsorbent column back into the collection tube.7. Preparation of DNase I mixture: Take 52 µl of RNase-Free Water, add 8 µl of 10×Reaction Buffer and 20 µl of DNase I (1 U/µl) to it, mix well, and prepare a final volume of 80 µl of reaction solution.8. Add 80µl of DNase I mixture directly to the adsorption column and incubate at 20-30°C for 15 minutes.9. Add 200 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, discard the waste liquid and put the adsorbent column back into the collection tube.10. Add 500µl Buffer RW2 to the column (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the column back into the collection tube.11. Repeat step 10.12. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for a few minutes to thoroughly dry the anhydrous ethanol in the adsorption column.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).13. Transfer the adsorbent column into a new centrifuge tube, add 30-50 µl of RNase-Free Water to the middle of the adsorbent membrane, leave it at room temperature for 1 min, centrifuge at 12,000 rpm for 1 min, collect the RNA solution, and store the RNA at -70°C to prevent degradation.Note: 1) The volume of RNase-Free Wate should not be less than 30 µl, too small volume affects the recovery rate.2) If you want to increase the RNA yield, repeat step 13 with 30-50 µl of fresh RNase-Free Water.3) If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 13 repeated... Read More |