| Description | Product contentS666146Component50 T200 TStorageS666146ABuffer GR25 mL120 mLRTS666146BBuffer GL25 mL120 mLRTS666146CBuffer GW1 (concentrate)13 mL52 mLRTS666146DBuffer GW2 (concentrate)15 mL75 mLRTS666146EBuffer GE15 mL60 mLRTS666146FProteinase K1.25 mL4×1.25 mLRTS666146GSpin Columns DS with Product contentS666146Component50 T200 TStorageS666146ABuffer GR25 mL120 mLRTS666146BBuffer GL25 mL120 mLRTS666146CBuffer GW1 (concentrate)13 mL52 mLRTS666146DBuffer GW2 (concentrate)15 mL75 mLRTS666146EBuffer GE15 mL60 mLRTS666146FProteinase K1.25 mL4×1.25 mLRTS666146GSpin Columns DS with Collection Tubes50 sets 200 setsRTS666146HCentrifuge Tubes (1.5 mL)50 EA200 EARTProductsThis kit provides a simple and rapid method for the isolation and purification of total DNA from buccal swab samples. The kit adopts a silica matrix membrane that can specifically bind DNA and a unique buffer system to adsorb DNA efficiently and specifically, and 0.5-3.5 µg of genomic DNA can be obtained from each swab, and the extracted DNA fragments are large, pure and of stable and reliable quality. It is suitable for enzyme digestion, PCR, library construction, Southern hybridization and other experiments.Self-contained reagent: anhydrous ethanol.Pre-experiment Preparation and Important Notes1. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.2. If precipitation is found in Buffer GL before use, dissolve Buffer GL in a 56°C water bath.3. All centrifugation steps can be performed at room temperature.4. Sampling: Use a buccal swab to wipe the inside of the mouth 6 times, dry for 2 hours and store. To ensure that the sample is not contaminated by food or drink, do not eat or drink for 30 minutes before sampling.Procedure1. The swab of the buccal swab was cut from the rod with scissors and placed in a 2mL centrifuge tube (supplied) and 400µL Buffer GR was added.Note: For genomic DNA without RNA contamination, add 4 µL of RNase A solution at a concentration of 100 mg/ml and shake to mix.2. Add 20 µL of Proteinase K and 400 µL of Buffer GL, immediately vortex and shake for 15 seconds and mix thoroughly.Note: Mix well immediately after adding Buffer GL; do not add Proteinase K directly to Buffer GL for use.3.56°C for 10 minutes and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.4. Add 400 µL of anhydrous ethanol, vortex and shake to mix thoroughly, and centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube.Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.5. Add the solution and precipitate obtained in the previous step to the Spin Columns DS in two batches of up to 700 µL at a time into the collection tube. centrifuge the column at 12,000 rpm (∼13,400 × g) for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.6. Add 500 µL of Buffer GW1 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.7. Add 500 µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge the column at 12,000 rpm for 3 minutes, pour off the waste liquid in the collection tube, and put the column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 1 minute and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new 1.5 mL centrifuge tube, add 50 µL of Buffer GE or sterilized water to the middle of the adsorption column overhanging the column, let stand at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store at -20℃.Attention:(1) If the downstream experiment is sensitive to pH or EDTA, it can be eluted with sterilized water. The pH value of the eluent has a great influence on the elution efficiency. If the eluent is made of water, the pH value should be 7.0-8.5 (the pH value of water can be adjusted to this range by using NaOH), and the elution efficiency is not high when the pH value is lower than 7.0.2) For long-term storage, it is recommended to elute with Buffer GE and store at -20°C... Read More | Product content:ComponentG665836100 rxnsG665836100 rxnsG665836100 rxns2×GoldStar Probe One Step Buffer1.4 ml1.4 ml1.4 mlGoldStar Probe One Step EnzymeMix100 µl100 µl100 µl50×Low ROX-50 µl-50×High ROX--50 µlRNase-Free Water1.5 ml1.5 ml1.5 mlProduct IntroductionProduct content:ComponentG665836100 rxnsG665836100 rxnsG665836100 rxns2×GoldStar Probe One Step Buffer1.4 ml1.4 ml1.4 mlGoldStar Probe One Step EnzymeMix100 µl100 µl100 µl50×Low ROX-50 µl-50×High ROX--50 µlRNase-Free Water1.5 ml1.5 ml1.5 mlProduct Introduction:This product is a specialized reagent kit for one-step Real Time RTqPCR using probe methods (TaqMan, Molecular Beacon, etc.). When using this product for Real Time RT qPCR reaction, reverse transcription and quantitative PCR are requiredConducted in the same reaction system, there is no need to add reagents or open the tube cap during the reaction process, avoiding contaminationThis has improved the efficiency of the experiment. This product has high detection sensitivity, strong fluorescence signal, and high signal-to-noise ratio, making it very suitable forDetection of RNA viruses and other trace amounts of RNA. The special buffering system it contains can enable reverse transcriptase to interact with DNA polymeraseMaximize the effectiveness and improve reaction efficiency. By using this product, a wider linear range can be obtained, which is beneficial for the target base Due to more accurate quantification, good repeatability, and high reliability.ROX dye is used to correct the fluorescence signal error generated between wells in quantitative PCR instruments, and is generally used for ABIReal Time PCR amplification equipment from companies such as Stratagene. The excitation optical systems of different instruments vary, thereforeThe concentration of ROX dye must be matched with the corresponding fluorescence quantitative PCR instrument.matters needing attention:1. Before using the reagents in this reagent kit, please gently mix them upside down to avoid foaming as much as possible, and use them after brief centrifugation. 2. This product uses RNA as a template for one-step RT-PCR experiments, and RNase contamination should be avoided during the operation process,2.It is recommended to perform RNA operations in a dedicated area, using specialized instruments and consumables. Operators should wear masks and disposable gloves and frequently change gloves. Experimental consumables should be treated with a 0.1% DEPC (diethyl pyrocarbonate) aqueous solution at 37 ℃ for 12 hours and sterilized under high pressure for 30 minutes before use.3. Each reagent in this kit should avoid repeated freezing and thawing as much as possible, as repeated freezing and thawing may lead to a decrease in product performance.4. This reagent kit must use specific primers, and the selection of primers can be based on specific experiments. The quality of primer design directly affects the results of RT qPCR reaction. When designing primers, GC content, primer length, and primer should be considered Due to factors such as location, secondary structure of PCR products, it is recommended to use professional primer design software for design.5. It is recommended to use specific probes in this reagent kit and use professional design software for design. Usage: The following examples are typical reaction systems and conditions. In practical operation, corresponding improvements and optimizations should be made based on the differences in template, primer structure, and target fragment size. (Please prepare the reaction solution on ice)1. Dissolve the RNA template, primers, 2xGoldStar Probe One Step Buffer, GoldStar Probe One Step EnzymeMix, and RNase Free Water and place them on ice for later use.2. PCR reaction system: reagent 25 µl Reaction system final concentration 2×GoldStar Probe One Step Buffer 12.5 µl 1× Forward Primer,10 µM 0.5 µl 0.2 µM 1) Reverse Primer,10 µM 0.5 µl 0.2 µM 1) Probe ,10 µM 0.5 µl 0.2 µM 2) GoldStar Probe One Step EnzymeMix 1.0 µl / RNA Template X µl 10 pg – 100 ng3) 50×Low ROX or High ROX (optional)4) 0.5 µl 1× RNase-Free Water up to 25 µl /Note: 1) Typically, the primer concentration is 0.2 µ M can achieve good results, ranging from 0.1 to 1.0 µ M serves as a reference for setting the range. 2) The concentration of the probe used is related to the fluorescent quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance. Please refer to the instrument manual or the specific usage requirements of each fluorescent probe for concentration adjustment during actual use.3) The amount of RNA templates is usually based on 10 pg-100 ng as a reference. Due to the different copy numbers of target genes contained in templates of different species, gradient dilution can be applied to the templates to determine the optimal template usage.4) The excitation optical systems of different instruments vary, and depending on the instrument used for fluorescence quantification, 50 x Low ROX or 50 x High ROX can be added.3. Mix well, centrifuge briefly, and collect the solution to the bottom of the tube.4. RT-PCR reaction conditions steps temperature time / Reverse Transcription 45℃ 10 min / PCR pre denaturation 95℃ 10 min / denaturation 95℃ 15s 30-40cycle Annealing/Extension 60℃ 45s 30-40cycleAttention:1) The hot start enzyme used in this product must be activated under pre denaturation conditions of 95 ℃ and 5-10 minutes.2) It is recommended to use a two-step PCR reaction program. If good experimental results cannot be obtained due to the use of primers with lower Tm values, a three-step PCR amplification can be attempted. The annealing temperature should be set within the range of 56 ℃ -64 ℃ as a reference... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Apoptosis refers to the cell autonomous and orderly death controlled by genes to maintain the stability of the internal environment. Apoptosis is different from cell necrosis. Apoptosis generally refers to a programmed cell death process that occurs during the development of body cells or under the Apoptosis refers to the cell autonomous and orderly death controlled by genes to maintain the stability of the internal environment. Apoptosis is different from cell necrosis. Apoptosis generally refers to a programmed cell death process that occurs during the development of body cells or under the action of some factors through the regulation of intracellular genes and their products. Cell necrosis is a cell death process that is caused by strong physical and chemical or biological factors to cause disordered changes in cells. The difference between apoptosis and necrosis lies in the characteristic morphological and biochemical changes, including the changes of cell membrane permeability and nuclear chromatin, the contraction of cytoplasm and the loss of membrane asymmetry. The oxazole yellow/pi membrane permeability apoptosis detection kit produced by our company is a dual fluorescence detection kit based on oxazole yellow and PI dyes. This kit is suitable for fluorescence microscopy, flow cytometry, fluorescence microplate reader and other fluorescence detection systems. Oxazole yellow is a non cell membrane penetrating cyanine monomer green fluorescent dye with high affinity for DNA. It basically has no fluorescence when it is not bound to DNA, but can emit bright green fluorescence after binding to DNA. When apoptosis occurs, the permeability of cell membrane changes. At this time, oxazole yellow can enter the cell and bind to DNA, emitting bright green fluorescence. Therefore, it is often used for the detection of apoptosis. It should be noted that oxazole yellow can also stain dead cells, so it needs to be double stained with PI that specifically fluorescently stains dead cells to effectively determine apoptosis. PI (propidium iodide) is a red fluorescent dye that can stain DNA. It is an analog of pyridine bromide that releases red fluorescence after embedding double stranded DNA. Although PI cannot pass through the membrane of living cells, it can cross the damaged cell membrane of dead cells to stain nuclei. Therefore, oxazole yellow combined with PI can be directly used for the detection of apoptosis. Apoptotic cells show green fluorescence, dead cells show both red and green fluorescence positive, and living cells have little or no fluorescence.Components: Components O598364-50T A. Oxazole yellow dye 50 µL B. Propidium Iodide (PI) 50 µLUsage (using flow cytometry as an example):1. Cell preparation(1) For adherent cells, after trypsin digestion, resuspend in culture medium and wash once with pre cooled PBS; The digestion time of trypsin should not be too long to prevent false positives. Note: Digest with trypsin and allow the cells to recover in the optimal cell culture conditions and medium for about 30 minutes, then stain.(2) For suspended cells, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, and wash once with pre cooled PBS.2. Cell stainingSuspend cells in pre cooled PBS, with a recommended cell count of 106 cells/mL per sample. Add 1 µ L Oxazole Yellow and 1 µ L to 1 mL of the samplePI, Gently blow and mix well. Incubate on ice in the dark for 30 minutes. Note: We suggest adding the following two experimental controls:Blank tube: negative control group cells, without dye, used to regulate voltage.Single staining tube: Positive control group cells were treated with only two tubes, Oxazole yellow and PI, for regulating compensation.3. Flow detectionAfter incubation, the sample can be directly detected by flow cytometry, or centrifuged at 1000 rpm for 5 minutes, the supernatant can be aspirated, and the sample can be resuspended in 1 mL of pre cooled PBS for flow cytometry detection. Oxazole yellow can be excited by a 488 nm laser, and the detected fluorescence emission spectrum is around 530 ± 30 nm (FITC channel), while the PI channel emission spectrum is around 617 nm (PI or PE channel).Product parameters:Oxazole yellow dye:ex/em = 491 / 509 nm (bound DNA); Propidium iodine:ex/em = 535 / 617 nm (combined with DMatters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. fluorescent dyes have quenching problems. Please try to avoid light to slow down fluorescence quenching. 3. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Membrane permeability apoptosis assay... Read More | V669947 Component 50T Storage V669947A Buffer GL 15 mL RT V669947B Buffer GW1 (concentrate) 13 mL RT V669947C Buffer GW2 (concentrate) 15 mL RT V669947D Buffer RE 10 mL RT V669947E Proteinase K 12.5 mg RT V669947F Proteinase K Storage Buffer 1.25 mL RT V669947G Spin Columns RS with Collection Tubes V669947 Component 50T Storage V669947A Buffer GL 15 mL RT V669947B Buffer GW1 (concentrate) 13 mL RT V669947C Buffer GW2 (concentrate) 15 mL RT V669947D Buffer RE 10 mL RT V669947E Proteinase K 12.5 mg RT V669947F Proteinase K Storage Buffer 1.25 mL RT V669947G Spin Columns RS with Collection Tubes 50 RT V669947H RNase-Free Centrifuge Tubes (1.5 mL) 50 RTProductsThis kit is suitable for the extraction of viral RNA and DNA from fresh or frozen plasma, serum and cell-free body fluids. It is easy to operate as it does not require the use of organic solvents such as phenol and chloroform for extraction. The kit uses a unique buffer system to enable efficient and specific binding of viral nucleic acids in lysate to silica gel centrifugal adsorption columns. Inhibitors of PCR and enzyme reactions as well as residual impurities can be efficiently removed in a two-step effective rinsing step, and finally high purity viral nucleic acids can be obtained by using a low-salt buffer or water for elution. The purified viral nucleic acid is free of protein, nuclease and other impurities, and can be used directly in PCR, RT-PCR, Real-Time PCR, blotting experiments and so on.Self-contained reagent: anhydrous ethanol.Pre-experiment and Important Notes1. Add 1.25ml Proteinase K Storage Buffer to Proteinase K to dissolve it and store it at -20℃. Do not leave the prepared Proteinase K at room temperature for a long time, and avoid repeated freezing and thawing to avoid affecting its activity. Do not add Proteinase K directly into Buffer GL.2. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller DNA fragments and a decrease in the amount of extracted DNA.3. Avoid repeated freezing and thawing of serum or plasma, which can lead to protein denaturation or precipitation, reducing the viral titer and thus affecting the yield of extracted viral nucleic acids.4. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the label instructions of the reagent bottle before first use.5. Check Buffer GL for crystallization or precipitation before use. If crystallization or precipitation occurs, redissolve Buffer GL in a water bath at 56℃.Procedure1. Take a 1.5 ml centrifuge tube (self-provided) and add 20 µl Proteinase K.2. Add 200 µl serum or plasma to the centrifuge tube. Add 200µl Buffer GL and vortex and shake for 15 seconds.Note: 1) Sample volume less than 200 µl can be made up by adding 0.9% NaCl (self-provided). 2) In order to ensure effective lysis of the sample, the sample needs to be mixed well with Buffer GL after adding Buffer GL.3. Incubate at 56°C for 15 minutes, centrifuge briefly, and collect the solution from the wall of the tube to the bottom of the tube.4. 250 µl of anhydrous ethanol was added, vortexed and shaken for 15 seconds, left at room temperature for 5 minutes, centrifuged briefly, and the solution on the wall of the tube was collected at the bottom of the tube.Note: If the ambient temperature exceeds 25°C, anhydrous ethanol should be used after pre-cooling on ice.5. Add the solution obtained in step 4 to the adsorbent column (RNase-Free Columns RS) that has been loaded into the collection tube, and if the solution cannot be added at one time, it can be transferred in several times. centrifuge the column at 12,000 rpm (~13,400 × g) for 1 min, pour off the waste liquid in the collection tube, and put the column back into the collection tube.6. Add 500 µl of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.7. Add 500 µl of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Add 500 µl of anhydrous ethanol to the adsorbent column and centrifuge at 12,000 rpm for 1 min. Pour off the waste liquid in the collection tube and put the adsorbent column back into the collection tube.9. Centrifuge at 12,000 rpm for 3 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is the removal of residual ethanol from the adsorbent column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).10. Place the adsorption column in a new collection tube (RNase-Free Centrifuge Tube), add 20-150 µl of Buffer RE or sterilized water overhanging the middle of the adsorption column membrane, leave it at room temperature for 2-5 minutes, and then centrifuge it at 12,000 rpm for 1 minute to collect the nucleic acid solution.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH of the eluent has a great influence on the elution efficiency, if water is used as the eluent it should be ensured that its pH is 7.0-8.5 (the pH of water can be adjusted to this range with NaOH), and the elution efficiency is not high when the pH is lower than 7.0.(2) For long-term storage, please store the DNA solution at -20℃ and the RNA solution at -70℃.3) If the final concentration of DNA/RNA is to be increased, the DNA/RNA eluate obtained in step 10 can be re-spiked onto the adsorbent membrane and step 10 repeated... Read More |