| Description | Product content: M665794Component125 TStorageM665794A2×miRNA qPCR Mixture (ROX)2×750 µL-20℃. Avoid freeze/thaw cycleM665794BReverse Primer, 10 µM60 µL-20℃. Avoid freeze/thaw cycleM665794CddH2O1.5 mL-20℃. Avoid freeze/thaw cycle Product Introduction:This kitProduct content: M665794Component125 TStorageM665794A2×miRNA qPCR Mixture (ROX)2×750 µL-20℃. Avoid freeze/thaw cycleM665794BReverse Primer, 10 µM60 µL-20℃. Avoid freeze/thaw cycleM665794CddH2O1.5 mL-20℃. Avoid freeze/thaw cycle Product Introduction:This kit uses the principle of SYBR Green I chimeric fluorescent dye method for miRNA fluorescence quantitative PCR detection. The kit includes 2 x miRNA qPCR Mixture and Reverse Primer required for detection. 2 x miRNA qPCR Mixture is a new generation pre mixed form of fluorescence quantitative PCR detection reagent specially developed for miRNA quantitative detection. The fluorescent dye SYBR Green I contained in it can bind to all double stranded DNA, making the product suitable for detecting different target sequences without the need to synthesize specific labeled probes. The GoldStar Taq DNA polymerase is a chemically modified and highly efficient thermal starter enzyme, coupled with a unique buffer system, which enhances reaction specificity, sensitivity, and enables accurate quantification of miRNA over a wider range. The 2x miRNA qPCR Mixture contains ROX dye and is suitable for fluorescence quantitative PCR instruments that require ROX as a calibration dye.Note: This kit must be used in conjunction with the miRNA cDNA first strand synthesis kit.Self prepared experimental materials: qPCR upstream primer.Forward Primer design principles:1. Follow the most common principles of primer design.2.Based on mature miRNA sequences, replacing U with T is the most basic and simplest design method.3.The Tm value of the downstream primer provided in the reagent kit is 63.6 ℃, and the Tm value of the upstream primer should be designed to be around 63.6 ℃ as much as possible.4. If the Tm value of the primer directly designed according to principle "2" is too low, several bases (preferably G or C bases) can be added to the 5 'end of the primer; One or several A bases can also be added at the 3 'end; Alternatively, both the 5 'and 3' ends can be modified simultaneously.5.If the Tm value of a primer designed directly according to principle "2" is too high, several bases can be removed from the 5 'or 3' end of the primer.Notes:1. Before using the reagent, please gently mix it upside down to avoid foaming, and use it after a brief centrifugation.2. The amount of miRNA first strand cDNA added should not exceed 10% of the volume of Real time PCR.3. For special detection systems, high content of cDNA templates can easily lead to non-specific amplification. Dilute cDNA appropriately (10 or 100 times dilution) based on the abundance of detected miRNAs.4. The 2x miRNA qPCR Mixture in this product contains SYBR Green I and ROX dyes. When storing this product or preparing PCR reaction solution, strong light exposure should be avoided.5. Avoid repeated freezing and thawing of this product. Repeated freezing and thawing may cause a decrease in product performance. This product can be stored at -20 ℃ for long-term storage. If frequent use is required in the short term, the 2xmiRNA qPCR Mixture can be stored at 2-8 ℃. However, the Reverse primer still needs to be stored at -20 ℃.Operation steps:1. Melt 2 x miRNA qPCR Mixture and Reverse Primer at room temperature (10 µ M). 2. When using, please gently mix the 2x miRNA qPCR Mixture upside down to avoid foaming, and use after brief centrifugation. If the reagent is not well mixed, its reaction performance will decrease.3. Place the reagent on ice and prepare the reaction system according to the following table: reagent volume final concentration 2×miRNA qPCR Mixture(ROX) 10 µl 1× Forward primer(10 µM) 0.4µl 0.2 µM Reverse primer(10 µM) 0.4µl 0.2 µM MiRNA first strand cDNA X µl — ddH2O up to 20 µl —4. The reaction program is set as follows:Attention!The pre denaturation reaction of this product must be completed at 95 ℃ for 10 minutes! Note: 1) The hot start enzyme used in this product must be activated under pre denaturation conditions of 95 ℃ and 10 minutes.2) The annealing temperature should be set at 60-64 ℃ as a reference range. When non-specific reactions occur, the annealing temperature can be increased... Read More | Hydrogen peroxide, a reactive oxygen species produced through the metabolism of molecular oxygen, serves as both an intracellular signaling messenger and a source of oxidative stress. Hydrogen peroxide is generated in cells via multiple mechanisms such as the NOX-mediated ROS production by Hydrogen peroxide, a reactive oxygen species produced through the metabolism of molecular oxygen, serves as both an intracellular signaling messenger and a source of oxidative stress. Hydrogen peroxide is generated in cells via multiple mechanisms such as the NOX-mediated ROS production by neutrophils and macrophages (respiratory burst) or by the dismutase of superoxide anions produced as a result of electron leak during mitochondrial respiration. Abnormal hydrogen peroxide production contributes to oxidative cell damage and the progression of diseases such as asthma, atherosclerosis, osteoporosis, and neurodegeneration.Intracellular hydrogen peroxide assay kit has been used to measure intracellular hydrogen peroxide levels... Read More | M666110 Component 96 T Storage M666110A Buffer WSL 40 mL RT M666110B Buffer MSL 40 mL RT M666110C Buffer CW1 (concentrate) 90 mL RT M666110D Buffer GW1 (concentrate) 40 mL RT M666110E Buffer GW2 (concentrate) 50 mL RT M666110F Buffer EB 30 mL RT M666110G Proteinase K 4×1.25 mL RT M666110H M666110 Component 96 T Storage M666110A Buffer WSL 40 mL RT M666110B Buffer MSL 40 mL RT M666110C Buffer CW1 (concentrate) 90 mL RT M666110D Buffer GW1 (concentrate) 40 mL RT M666110E Buffer GW2 (concentrate) 50 mL RT M666110F Buffer EB 30 mL RT M666110G Proteinase K 4×1.25 mL RT M666110H Magbeads V3 2×1 mL RTProduct Introduction:The reagent kit provides a simple, fast, and efficient method for extracting genomic DNA from blood samples. In the presence of high salt, DNA binds to the surface of silica coated Magheads. After rinsing, high-purity DNA is eluted in Buffer EB or deionized water. The purified DNA has good purity (A260/280 ratio between 1.7-1.9) and high integrity (>15 kb), and can be used for downstream experiments such as second-generation sequencing, quantitative PCR, and chip detection.Self provided instruments and reagents1) Constant temperature mixer2) 2/15 ml magnetic frame3) 32 channel nucleic acid extractor4) 96 channel nucleic acid extractor5) 96 DW Plate6) 8 channel Comb7) Spin tips pack8) Anhydrous ethanolPreparation and important precautions before the experiment1.Before the first use, add anhydrous ethanol to Buffer CW1, Buffer GW1, and Buffer GW2 according to the label of the reagent bottle and mark them properly.2.Magheads are strictly prohibited from freezing or centrifugation. Freezing and centrifugation may cause irreversible damage to Magheads.Operation stepsI. Manual single tube operation1. Use punching forceps to take 1 blood spot with a diameter of 6 mm or 4 blood spots with a diameter of 3 mm (depending on the actual situation) from the blood spot and place them in a 2.0 mL centrifuge tube.2. Add 40 to the centrifuge tube µ L Protein K and 300 µ L Buffer WSL, then place the centrifuge tube on a constant temperature mixer at 75 ℃ and 1200 rpm, shake and crack for 45 minutes to form Lysate. Remove the centrifuge tube from the constant temperature mixer, centrifuge briefly, and take the supernatant.Attention: If there is no constant temperature mixer, vortex the centrifuge tube for 10 seconds and incubate it in a 75 ℃ water bath for 30 minutes. During this period, vortex every 10 minutes for 10 seconds.3. Suck the supernatant into a new 2.0 mL centrifuge tube and add 300 µ L Buffer MSL, 300 µ L isopropanol and 20 µ L Magheads V3. Afterwards, place the centrifuge tube on a constant temperature mixer at 25 ℃ and 1600 rpm, shake and crack for 15 minutes, or invert the centrifuge tube and mix continuously for 15 minutes.4. Place the centrifuge tube on a magnetic stand and let it stand for 1 minute. After Magheads are completely adsorbed on the side wall of the centrifuge tube, discard the solution thoroughly (keep the centrifuge tube fixed on the magnetic stand).5. Remove the centrifuge tube from the magnetic frame and add 900 µ L Buffer CW1 (please check if anhydrous ethanol has been added before use), vortex point shake for 1 minute or vortex shake for 5 seconds, and then place it on a constant temperature mixer at 25 ℃ and 1600 rpm to shake and mix for 2 minutes (ensure that Magheads are in a mixed state during the shaking process). Afterwards, place the centrifuge tube on a magnetic stand and let it stand for 1 minute. After Magheads are completely adsorbed on the side wall of the centrifuge tube, gently invert the magnetic stand and wash the impurities on the centrifuge tube cover to completely discard the solution (keep the centrifuge tube fixed on the magnetic stand).6. Remove the centrifuge tube from the magnetic frame and add 500 µ L Buffer GW1 (please check if anhydrous ethanol has been added before use), vortex point shake for 1 minute or vortex shake for 5 seconds, and then place it on a constant temperature mixer at 25 ℃ and 1600 rpm to shake and mix for 2 minutes (ensure that Magheads are in a mixed state during the shaking process). Afterwards, place the centrifuge tube on a magnetic stand and let it stand for 1 minute. After Magheads are completely adsorbed on the side wall of the centrifuge tube, gently invert the magnetic stand and wash the impurities on the centrifuge tube cover to completely discard the solution (keep the centrifuge tube fixed on the magnetic stand).7. Remove the centrifuge tube from the magnetic frame and add 900 µ L Buffer GW2 (please check if anhydrous ethanol has been added before use), vortex point shake for 1 minute or vortex shake for 5 seconds, then place it on a constant temperature mixer at 25 ℃ and 1600 rpm, shake and mix for 2 minutes (ensure that Magheads are in a mixed state during the shaking process). Afterwards, place the centrifuge tube on a magnetic stand and let it stand for 1 minute. After Magheads are completely adsorbed on the side wall of the centrifuge tube, gently invert the magnetic stand and wash the impurities on the centrifuge tube cover to completely discard the solution (keep the centrifuge tube fixed on the magnetic stand).8. Remove the centrifuge tube from the magnetic frame and add 300 µ After shaking with 75% ethanol for 1 minute or 5 seconds, place the mixture on a constant temperature mixer at 25 ℃ and 1600 rpm for 2 minutes (ensure that the Magheads are in a mixed state during the shaking process). Afterwards, place the centrifuge tube on a magnetic stand and let it stand for 1 minute. After Magheads are completely adsorbed on the side wall of the centrifuge tube, gently invert the magnetic stand and wash the impurities on the centrifuge tube cover to completely discard the solution (keep the centrifuge tube fixed on the magnetic stand).9. Keep the centrifuge tube fixed on the magnetic frame, use a pipette to further remove the solution from the bottom and cover of the centrifuge tube, and then leave it at room temperature for 5-10 minutes to allow the ethanol to evaporate completely.10. Remove the centrifuge tube from the magnetic frame and add 50-200 µ L Buffer EB. Vortex oscillation causes the magnetic beads to completely suspend in the eluent and then place them on a constant temperature mixer at 56 ℃ and 1600 rpm for 10 minutes of shaking and elution, or incubate the centrifuge tube in a 56 ℃ water bath for 10 minutes, with vortex oscillation every 3 minutes for 10 seconds.11. Place the centrifuge tube on a magnetic stand and let it stand for 2 minutes. After Magheads are completely adsorbed on the side wall of the centrifuge tube, transfer the eluent to a new centrifuge tube using a pipette and store at -20 ℃ for later use.II. Matching with CWE21001. Use punching forceps to take 1 blood spot with a diameter of 6 mm or 4 blood spots with a diameter of 3 mm (depending on the actual situation) from the blood spot and place them in a 2.0 mL centrifuge tube.2. Add 40 to the centrifuge tube µ L Protein K and 300 µ L Buffer WSL, then place the centrifuge tube on a constant temperature mixer at 75 ℃ and 1200 rpm, shake and crack for 45 minutes to form Lysate.3. Add the corresponding reagents to the 96DW deep well plate according to the table below. Position Reagent 1&7 Colume Lysate: All Buffer MSL: 300 µL isopropanol:300 µL Magbeads V3: 20 µL 2&8 Colume Buffer CW1: 900 µL 3&9 Colume Buffer GW1: 500 µL 4& 10 Colume Buffer GW2: 900 µL 5& 11 Colume 75%ethanol: 300 µL 6& 12 Colume Buffer EB: 70 µL4.Place the deep well plate and magnetic sleeve that have been added to the reagent at the corresponding positions of CWE2100/CWE3200, run the blood slide extraction program, and after about 40 minutes, the program ends. Remove the deep well plate and magnetic sleeve.5.Transfer the elution products from columns 6 and 12 of the deep well plate to a 1.5 mL centrifuge tube for low-temperature storage.III. Matching with CWE9601. Use punching forceps to take 1 blood spot with a diameter of 6 mm or 4 blood spots with a diameter of 3 mm (depending on the actual situation) from the blood spot and place them in a 2.0 mL centrifuge tube.2. Add 40 to the centrifuge tube µ L Protein K and 300 µ L Buffer WSL, then place the centrifuge tube on a constant temperature mixer at 75 ℃ and 1200 rpm, shake and crack for 45 minutes to form Lysate.3. Add the corresponding reagents to the 96DW deep well plate according to the table below Position Reagent Plate 1 Lysate: All Buffer MSL: 300 µL isopropanol :300 µL Magbeads V3: 20 µL Plate 2 Buffer CW1: 900 µL Plate 3 Buffer GW1: 500 µL Plate 4 Buffer GW2: 900 µL Plate 5 75% ethanol : 300 µL Plate 6 Buffer EB: 70 µL4. Place the deep well plate and magnetic sleeve that have been added to the reagent at the corresponding positions on CWE960, run the blood slide extraction program, and after about 40 minutes, the program ends. Remove the deep well plate and magnetic sleeve.5. Transfer the elution products from Plate 6 to a 1.5 mL centrifuge tube for low-temperature storage... Read More | This product can rapidly, gently, and efficiently lyse mammalian cells, effectively extracting cytoplasmic and nuclear proteins. This reagent uses a mild formula to ensure that the extracted protein maintains biological activity and can be applied to various protein analysis experiments, such as This product can rapidly, gently, and efficiently lyse mammalian cells, effectively extracting cytoplasmic and nuclear proteins. This reagent uses a mild formula to ensure that the extracted protein maintains biological activity and can be applied to various protein analysis experiments, such as reporter gene and enzyme activity determination, immune detection, protein purification, etc. The extracted protein can be quantitatively analyzed using the BCA method. The reagent kit contains a mixture of protease inhibitors, which can effectively prevent protein degradation during the protein extraction process.M665813Component100 TStorageM665813AMammalian Protein Extraction Reagent100 mLRTM665813BProtease Inhibitor Cocktail (100×)1 mL-20℃. Avoid freeze/thaw cycle. precautions1. This product can effectively lyse adherent cells cultured on cell culture plates (without scraping) and suspended cells collected by centrifugation, with higher extraction efficiency than repeated freeze-thaw or ultrasound methods. But for the extraction of tissue proteins, it is recommended to use the tissue protein extraction kit (CW0891).The optimal dosage for protein extraction from adherent cells is listed in Table 1. Collecting cells first can reduce the amount of reagents used to obtain higher protein concentrations.3. The amount of extraction reagents used can also be estimated based on the number of cells. If 2 × 106 Hela cells weigh about 20 mg, 200 need to be added µ Extract reagents.4. The protein extracted from this product can be quantitatively analyzed using the BCA method.Operation steps● Protein extraction from adherent cells1. Please remove the required Mammalian Protein Extraction Agent for pre cooling before protein extraction.2. Carefully pour out the culture medium of adherent cells and rinse the cells with PBS.3. Add an appropriate amount of Mammalian Protein Extraction Reagent (add Protein Inhibitor Cocktail in a 1:99 ratio 2-3 minutes before protein extraction), blow adherent cells on ice with a gun tip, transfer the lysate to a centrifuge tube, incubate on ice for 20 minutes, and allow the cells to fully lyse (please refer to Appendix 1 for the amount of reagent used, and the time for placing on ice should be adjusted according to different cell types). 4. Centrifuge at 14000 × g for 5-10 minutes.5. Transfer the supernatant to a new tube for further analysis. ● Suspension cell protein extraction1. Please remove the required Mammalian Protein Extraction Agent for pre cooling before protein extraction.2. Suspend 2500 × g of cells, centrifuge for 10 minutes, and discard the supernatant. Rinse cells with PBS. 2500 × g, centrifuge for 10 minutes, discard the supernatant.3. Add an appropriate amount of Mammalian Protein Extraction Agent, and 2-3 minutes before protein extraction, add Protein Inhibitor Cocktail in a ratio of 1:99, which is 1 x working solution.4. Add at least 1 ml of 1x working solution to every 100 mg of cells. If the extracted sample size is large, a small amount of 1x working solution can be used to resuspend the cells first, and then the remaining working solution can be added.5. After blowing evenly, place it on ice for 20 minutes to allow the cells to fully lyse (the time for placing it on ice should be adjusted according to different cell types). 6. Centrifuge at 14000 × g for 15 minutes.7. Transfer the supernatant to a new tube for further analysis.Table 1. Recommended usage of extraction reagents Cell culture plate type or dish type Extraction reagent usage 100 mm 500-1,000 µl 60 mm 250-500 µl 6-well culture plate 200-400 µl /well 24-well culture plate 100-200 µl /well 96-well culture plate 50-100 µl /well Table 2. Common Problems and Solutions Problem Possible reasons Resolvent Low extraction rate Low protein expression level Optimize transfection system Low extraction rate Insufficient reagent usage Increase the usage of extraction reagents Low extraction rate Reagent unable to dissolve cell membrane Increase cracking time or increase shaking amplitude Unable to obtain membrane protein This product is more suitable for extracting nuclear plasma protein Using eukaryotic cell membrane protein extraction kit... Read More | Product content: Component O66550510 preps O665505 50 preps Blocking Buffer 100 ml 500 ml Antibody Pretreat Solution( HRP/Mouse ) 1 ml 5 × 1 ml Dilution Buffer 100 ml 500 ml Wash Buffer( 10× ) 100 ml 500 mlProduct Introduction:The one-step rapid WB assay kit (Product content: Component O66550510 preps O665505 50 preps Blocking Buffer 100 ml 500 ml Antibody Pretreat Solution( HRP/Mouse ) 1 ml 5 × 1 ml Dilution Buffer 100 ml 500 ml Wash Buffer( 10× ) 100 ml 500 mlProduct Introduction:The one-step rapid WB assay kit (mouse) is the latest Western Blot detection kit developed by Kangwei Century, which can obtain high-quality Western Blot results in about 1 hour. It is easy to operate, has high detection sensitivity, low background, does not require the addition of secondary antibodies, and has strong system stability. The conventional Western Blot indirect detection process (blocking, primary antibody binding, and secondary antibody binding) requires a long time, a complex experimental process, and requires multi-step condition optimization. After transferring the protein on the gel to the carrier membrane, incubate it with the blocking solution in the reagent kit for 5 minutes, and then incubate the carrier membrane with the primary antibody treated with antibody reaction solution. After washing three times (5 minutes each time), luminescence or colorimetric detection can be performed. This reagent kit is designed for use in experimental systems where the target protein primary antibody is derived from mice.Notes:1. The customer prepares their own mouse source primary antibody.2. Before using Blocking Buffer blocking solution, Antibody Pretreat Solution (HRP/Mouse) antibody reaction solution (mouse), and Wash Buffer (10 x) rinse solution, please mix thoroughly.3. If there is precipitation in the rinsing solution when stored at 2-8 ℃, please restore it to room temperature, dissolve the precipitation, and use it normally. The 1x rinsing solution can be stored at room temperature for one month.4. It is recommended to stain the membrane with reagents such as spring red after the transfer is completed, and cut off any excess parts on the membrane to increase the efficiency of the reagents.5. The optimal dilution amount for primary antibody and antibody reaction solution HRP (mouse) needs to be determined through preliminary experiments.6. The antibody reaction solution HRP (mouse), antibody dilution solution, and antibody dosage can be increased or decreased proportionally according to the size of the membrane.7. The antibody dilution solution containing the first antibody can be recycled and reused once. It is recommended not to reuse antibodies with poor specificity and affinity. If the recovered antibody is used within 1-2 days and stored at 2-8 ℃ for long-term storage, please freeze it at -20 ℃ to avoid repeated freeze-thaw cycles.8. If there is a high background, please adjust the amount of antibodies and increase the number of times the film is washed.9. All reagents in the reagent kit should be stored at 2-8 ℃ to avoid freezing and thawing.Operation steps:This product is suitable for the sealing and antibody incubation steps after membrane transfer, taking a 5 cm x 8 cm membrane as an example:1. Preparation of rinsing solution: Dilute 10 ml of Wash Buffer (10 x) with distilled water to 100 ml, which is 1 x Wash Buffer. Set aside. Use 8-10 ml for each film wash.2. Sealing: After the membrane transfer is completed, immerse the membrane in 10 ml Blocking Buffer and seal at room temperature for 5 minutes.3. Rinse: Pour off the sealing solution, add 8-10 ml of 1 x Wash Buffer, and rinse at a high speed on a shaker for 1 minute.4. Prepare antibody incubation solution while washing the membrane: Take Antibody Pretreat Solution (HRP/Mouse) 100 µ Add mouse derived primary antibody 3-10 into the centrifuge tube µ g. Suck and beat the gun head until thoroughly mixed, and incubate at room temperature for 5 minutes. Add to 10 ml Dilution Buffer and mix well. Note: 1) The dosage of primary antibody can also be adjusted according to the dilution of the antibody. Taking the final dilution of antibodies at 1:1000 as an example, take 100 µ Add HRP (mouse) antibody reaction solution into the EP tube and add 10 µ Add the first antibody to 10 ml of antibody diluent, mix well, and incubate at room temperature for 5 minutes. 2) If the membrane area is small, the amount of antibodies, reaction solution, and diluent can be reduced proportionally.5. After completing step 3, pour out the rinsing solution and add the antibody incubation solution mixed with primary antibody, Antibody Pretreat Solution (HRP/Mouse), and Dilution Buffer to the membrane (ensuring that the incubation solution completely submerges the surface of the membrane). Incubate at room temperature on a shaker at around 60 rpm for 40 minutes.6. Discard (recover) the antibody incubation solution and rinse 3-5 times with the prepared 1 x Wash Buffer, each time for 3 minutes. 7. Conduct subsequent testing. It is recommended to use ECL or DAB methods for testing.Application examples:Example 1 Antigen is 293T cell lysateA: Normal WB control: beta actin mouse monoclonal antibody (CW0096) 5 µ Incubate at room temperature for 40 minutes, wash the film and dilute the secondary antibody sheep anti mouse HRP (CW0102) 1:10000. Incubate at room temperature for 40 minutes and expose ECL (CW0049).B: One step method WB: beta actin mouse monoclonal antibody (CW0096) 5 µ Incubate at room temperature for 40 minutes and expose ECL (CW0049).Example 2 Antigen is E. coli multi label protein lysateC: Normal WB control: GST mouse monoclonal antibody (CW0084) 2.5 µ Incubate at room temperature for 40 minutes, wash the film and dilute the secondary antibody sheep anti mouse HRP (CW0102) 1:10000. Incubate at room temperature for 40 minutes and expose ECL (CW0049).D: One step method WB: GST mouse monoclonal antibody (CW0084) was incubated at room temperature with 2.5ug for 40 minutes, and ECL (CW0049) was exposed... Read More |