| Description | The Succinic Acid (Succinate) assay kit is suitable for the specific assay of succinic acid in wine, cheese, eggs, sauce and other food products. Succinic acid (or succinate) is found in all plant and animal materials as a result of the central metabolic role played by this dicarboxylic acid in the The Succinic Acid (Succinate) assay kit is suitable for the specific assay of succinic acid in wine, cheese, eggs, sauce and other food products. Succinic acid (or succinate) is found in all plant and animal materials as a result of the central metabolic role played by this dicarboxylic acid in the Citric Acid Cycle. Succinic acid concentrations are monitored in the manufacture of numerous foodstuffs and beverages, including wine, soy sauce, soy bean flour, fruit juice and dairy products (e.g. cheese).Product Description: Succinic acid is found in all plant and animal materials as a result of the central metabolic role played by this dicarboxylic acid in the Citric Acid Cycle. Succinic acid concentrations are monitored in the manufacture of numerous foodstuffs and beverages, including wine, soy sauce, soy bean flour, fruit juice and dairy products (e.g. cheese). The ripening process of apples can be followed by monitoring the falling levels of succinic acid. The occurrence of > 5 mg/kg of this acid in egg and egg products is indicative of microbial contamination. Apart from use as a flavouring agent in the food and beverage industries, succinic acid finds many other non-food applications, such as in the production of dyes, drugs, perfumes, lacquers, photographic chemicals and coolants. Preparation Instructions:Suitable for succinate determination in food, beverage, agricultural products, and other biological samples.Note for Content:The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).Browse all of our organic acid assay kits.Principle:The Succinate Assay Kit provides a simple, one step assay for measuring succinate. In this assay succinate is converted to pyruvate which reacts with specific reagents and dye to form a colored product. The color intensity at 570 nm or fluorescencAdvantages:Extended cofactors stability. Dissolved cofactors stable for > 1 year at 4oC.Very competitive price (cost per test)All reagents stable for > 2 years as suppliedVery rapid reaction (even at room temperature)Mega-Calc™ software tool is available from our website for hassle-free raw data processingStandard includedSuitable for manual, microplate and auto-analyser formats... Read More | Product IntroductionAlamar Blue detection reagent provides a simple, rapid, reliable and safe method for cell proliferation and cytotoxicity detection, which is suitable for high-throughput detection experiments. The main component of the detection reagent is a redox indicator. In the oxidized stateProduct IntroductionAlamar Blue detection reagent provides a simple, rapid, reliable and safe method for cell proliferation and cytotoxicity detection, which is suitable for high-throughput detection experiments. The main component of the detection reagent is a redox indicator. In the oxidized state, it appears purple-blue and non-fluorescent, while in the reduced state, it turns into a reduction product with pink or red fluorescence, with an absorption peak of 530-560nm and an emission peak of 590nm.In the process of cell proliferation, the ratios of NADPH/NADP, FADH/FAD, FMNH/FMN and NADH/NAD in the cell increase and are in a reducing environment. The dye taken into the cell is reduced by these metabolic intermediates and cytochromes and then released outside the cell and dissolved in the culture medium, changing the culture medium from non-fluorescent indigo blue to fluorescent pink. Finally, use an ordinary spectrophotometer or fluorophotometer for detection, and the absorbance and fluorescence intensity are proportional to the number of active cells.Instructions1. Add 10µl of detection reagent to 100µl of cell suspension, and incubate in a cell incubator for 2-6 hours. The color of the medium changes from indigo blue to pink and you can proceed to the next step.2. It is recommended to use a fluorescence microplate reader for detection, the excitation light wavelength is between 530-560 nm, the emission light wavelength is 590 nm, and the relative fluorescence unit (RFU) is recorded.3. Draw a standard curve or cell growth curve: the ordinate (Y axis) is the relative fluorescence unit (RFU); the abscissa (X axis) is the cell number or time point or drug concentration.Precautions1. The appropriate density of cells can increase the detection sensitivity. For 96-well plates, we recommend seeding 100 microliters of cells per well. The cell concentration range is: 100-10,000/well for adherent cells, 2,000-50,000/well for suspension cells, and medium as a blank control. For 384-well plates, the cell concentration and seeding volume are both halved.2. The whole process should be aseptic operation, because microbial contaminants can also reduce the detection reagents and affect the experimental results.3. Pay attention to the concentration of inoculated cells and the incubation time after adding detection reagents. If the cell concentration is too high or the incubation time is too long, it will cause a secondary reduction reaction, resulting in colorlessness and disappearance of fluorescence.4. When incubating, avoid light.5. This product can use fluorescence or spectrophotometric detection, but the sensitivity of fluorescence is high, and the experimental error is small. Fluorescence detection is recommended... Read More | Products contentN665954Component24 T96 TStorageN665954ATPS V136 µL144 µL-20℃. Avoid freeze/thaw cycle.N665954B5×FA Reaction Buffer96 µL384 µL-20℃. Avoid freeze/thaw cycle.N665954CTS Buffer72 µL288 µL-20℃. Avoid freeze/thaw cycle.N665954D2× Products contentN665954Component24 T96 TStorageN665954ATPS V136 µL144 µL-20℃. Avoid freeze/thaw cycle.N665954B5×FA Reaction Buffer96 µL384 µL-20℃. Avoid freeze/thaw cycle.N665954CTS Buffer72 µL288 µL-20℃. Avoid freeze/thaw cycle.N665954D2× PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw cycle. * This kit is suitable for human genomic DNA library construction, the starting template DNA input amount is 1 ng, our company also has 50 ng and 5 ng of human genomic DNA starting transposase method library construction kit, in order to get a higher quality library, different starting amount of DNA is recommended to use different kits. Products IntroductionThis kit is developed for Illumina's high-throughput sequencing platform and provides the enzyme premix system and reaction buffer for genomic DNA library construction, including all components except PCR primers. Compared with the traditional library construction kits, this kit adopts the new transposase method for library construction, which can complete DNA fragmentation, end repair and junction reaction in one simple enzymatic reaction, significantly reducing the amount of template, reducing the number of experimental steps, and shortening the time of library construction; it adopts the high-fidelity DNA polymerase for library enrichment, and the preference-free PCR amplification can expand the coverage area of the sequence, which can be used for efficient and effective sequencing. The use of high-fidelity DNA polymerase for library enrichment and preference-free PCR amplification broadens the coverage area of the sequence and enables efficient preparation of DNA libraries for Illumina's second-generation sequencing platform. The kit is suitable for use with 1 ng of starting template DNA, and all reagents in the kit have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction.Product Features● DNA fragmentation and junction ligation in one step.● Ultra-fidelity amplification minimizes amplification preference.Provide your own instruments, kits and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. Library PCR primer kit: It is recommended to use Kangwei transposase method for second generation sequencing multi-sample primer kit.4. Anhydrous ethanol, deionized water (pH between 7.0 and 8.0).5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes.Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important Notes1. Avoid repeated freezing and thawing of reagents.2. PCR products are easily contaminated due to improper operation, resulting in inaccurate results. It is recommended to isolate the PCR reaction system preparation area from the PCR product purification area, and to use special pipettes to clean the experimental areas at regular intervals.3. Bead purification: the beads should be equilibrated to room temperature before use, all operations on the beads should be carried out at room temperature, 80% ethanol should be dispensed freshly, the beads should be rinsed and dried until the surface is free of liquid reflections and has a frosted appearance, insufficient drying of the beads will cause ethanol residue that will affect the subsequent experiments, and over-drying of the beads will affect the efficiency of DNA recovery.4. The kit is suitable for human genomic DNA library construction, if the DNA sample is a PCR product, it should be ensured that its length>.500 bp, since transposases do not work on DNA ends, it is recommended to extend the PCR product by 50-100 bp at each end of the PCR product to avoid low coverage of the ends for sequencing. Sample PreparationDNA purity requirement: A260/A280 = 1.8-2.0. Sample DNA: dissolved in ultrapure water.DNA quantification: Too much or too little DNA will affect the quality of the library. It is recommended to use Nano to test the purity of the genomic DNA and then use Qubit to test the concentration of the genome (do not use any absorbance-based assay for template quantification). Schematic diagram of DNA banking process procedureDNA fragmentation, junction reaction 1. Add the following reagents to a 200 µl PCR tube:2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:inactivation reactionAfter the DNA is fragmented, the enzyme is still in a high active state, so it should be removed from the PCR instrument immediately and terminated by adding the Reaction Termination Buffer, in order to prevent the DNA from being fragmented too much and resulting in smaller library fragments.1. Add 3 µl of TS Buffer to the PCR tube containing the fragmentation product.2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Incubate at room temperature for 5 min, or if the room temperature is too low, place the reaction on a PCR instrument at 25°C with the thermal cover closed.PCR amplification1. Add the following reagents to a 200 µl PCR tube.2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube. 3. Place the above PCR tubes in the PCR instrument with the thermal cap open, and the reaction program is as follows:Selective recovery of library DNA fragmentsIt is recommended to use CombiVision Magnetic Beads DNA Purification and Recovery Kit for selective recovery of DNA fragments. When different sizes of DNA fragments are required, the amount of magnetic beads used is different, please refer to the attached table for the specific amount of magnetic beads used.(If using other brands of magnetic beads, you need to figure out the optimal amount of magnetic beads by yourself).Note: Amplification products can also be fragment length sorted and purified using the Gum Recovery Kit. If there is no special requirement for library length distribution, amplification products can also be purified directly from DNA fragments without selective recovery of DNA fragments as described on page 4 of the manual.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Transfer the PCR products to a 1.5 ml centrifuge tube, rehydrate to 100 µl, add several volumes of magnetic beads equilibrated to room temperature, vortex for 5 seconds, and let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, and carefully aspirate the supernatant and transfer it to a new 1.5 ml centrifuge tube.Note: Do not discard the top clear.4. Add several volumes of magnetic beads to the supernatant, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.5. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA.Note: Do not discard the beads.6. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.7. Repeat step 6 once.8. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 20 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.9. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new tube. Table: Suggested amount of magnetic beads for different segment selection recoveryLibrary DNA fragment purificationWe recommend the use of the Kangwei Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. 50 µl of magnetic beads equilibrated to room temperature were added to the PCR product, vortexed and shaken for 5 seconds, and then left to stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 25 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new tube. Library quality controlDetermination of library concentrationIn order to obtain high-quality sequencing results, accurate quantification of DNA libraries is required, and the first recommendation is to use Real-timePCR methods are used for absolute quantification of DNA libraries. Additionally, fluorescent dye methods such as the Qubit method or the fluorescent dye picogreen method can be used; do not use quantification methods based on absorbance measurements here. The following approximate formula can be used to convert the molar concentration of the DNA library.Library fragment distributionThe prepared DNA libraries can be detected by agarose gel electrophoresis or Agilent 2100 Bioanalyzer.Range of segment length distributions... Read More | Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly luciferase is widely used in gene regulation and drug screening. Firefly luciferase is a protein with a molecular weight of about 61 KD. In the presence of ATP, magnesium ions and oxygen, it can catalyze the production of oxyluciferin from luciferin. In the process of luciferin oxidation, it will produce a light signal. The optical signal of this kit is a kind of instantaneous light, which needs to be detected immediately after adding the working solution. The half-life of optical signal is about 5 min.Instruction:1.Working fluid configuration ( 1 ) Restore all components to room temperature. ( 2 ) The component B ( stock solution ) was fully diluted with component A to prepare a 0.2 mg / mL firefly luciferase working solution, which was vortexed and shaken to ensure full mixing. Note : The firefly luciferase working solution cannot be repeatedly frozen and thawed. If the dosage of a single experiment is small, it is recommended to subpackage according to a single dosage. At room temperature, the activity decreased by about 10 % after the working solution was configured for 3 h, and the activity decreased by about 25 % after 5 h. 2.chemiluminescence value detection ( 1 ) The cell culture plate was taken out from the incubator and incubated at room temperature for 20 min to restore it to room temperature ( 22-25 ° C ). ( 2 ) Add the same volume of firefly luciferase working solution with the medium to the culture plate and mix well. ( 3 ) Incubation at room temperature for 5 min. Note : The incubation time can be adjusted according to cell type and cell number. ( 4 ) The values were read by multifunctional microplate reader or chemiluminescence instrument ( instrument parameters : the determination time was 10 s, the determination interval was 2 s ).Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. the strongest wavelength of bioluminescence catalyzed by firefly luciferase is 560 nm. 3. to prevent interference between holes, it is recommended to use white opaque orifice plate.Recommendation:Component B is recommended to use sterile water in advance to configure 2 mg / mL storage solution, A component and B component configured as storage solution, and small batch packaging according to the experimental requirements. The detection working fluid is recommended to be used now to avoid repeated freezing and thawing. Component:One-Step Firefly Luciferase Assay Buffer;D-Luciferin Scope of application:Mainly used for ADCC detection... Read More | This kit is used to extract and purify high-quality total RNA from various plants, and is also suitable for the extraction of fungal hyphal RNA. A unique Shredder separation column is used for homogenization and filtration of high viscosity plant or fungal lysates, while silica based membrane is This kit is used to extract and purify high-quality total RNA from various plants, and is also suitable for the extraction of fungal hyphal RNA. A unique Shredder separation column is used for homogenization and filtration of high viscosity plant or fungal lysates, while silica based membrane is used to adsorb RNA for purification, effectively removing various pollutants such as polysaccharides through washing. The washed RNA can be directly used in various downstream experiments. RNA with a molecular weight greater than 200 bases was extracted using this reagent kit, with high purity and almost no DNA residue. If it is an RNA experiment that is very sensitive to trace amounts of DNA, the remaining DNA can be digested and removed on a column using DNase I without RNase. The extracted RNA can be used for experiments such as Northern Blot, Dot Blot, RT-PCR, and in vitro translation. R665489Component50 TStorageR665489ABuffer RL35 mLRTR665489BBuffer RLC35 mLRTR665489CBuffer RW140 mLRTR665489DBuffer RW2 (concentrate)11 mLRTR665489ERNase-Free Water10 mLRTR665489FSpin Columns FL with Collection Tubes50 setsRTR665489GSpin Columns RM with Collection Tubes50 setsRTR665489HRNase-Free Centrifuge Tubes (1.5 mL)50 EART Self prepared reagents:β- Mercaptoethanol, anhydrous ethanol (newly opened or dedicated for RNA extraction).Preparation and important precautions before the experiment:To prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The extracted samples should avoid repeated freeze-thaw cycles, otherwise it will affect the quantity and quality of RNA extraction.3. Please add Buffer RL before use β- Mercaptoethanol, with a final concentration of 1%. Add 10 to 1 ml Buffer RL µ L β Mercaptoethanol. join β- The buffer RL room temperature of mercaptoethanol can be stored for one month. No need to add buffer RLC when using it β- Mercaptoethanol.Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. If precipitation occurs in Buffer RL and Buffer RLC, please heat them to dissolve and place them at room temperature.6. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.7. If downstream experiments are highly sensitive to DNA, it is recommended to treat RNA with DNase I without RNase.Operation steps:1. Take 50-100 mg of fresh plant tissue, add liquid nitrogen and quickly grind it into powder.2. Collect the ground powder into a centrifuge tube (provided by oneself) and add 600 µ L Buffer RL (check if it is added before use) β- Sulfhydryl ethanol or Buffer RLC, vortex oscillation causes it to fully decompose.Attention:1) The main component of Buffer RL is guanidine isothiocyanate, which is suitable for the lysis of most plant tissues. However, in some plant tissues (such as corn endosperm), due to the unique secondary metabolites, guanidine isothiocyanate causes precipitation in the sample, resulting in poor RNA extraction efficiency. In this case, Buffer RLC can be added instead of Buffer RL.2) Incubating at 56 ℃ for 1-3 minutes helps with tissue lysis, but plants with high starch content should not be subjected to high-temperature incubation.3. Transfer all the liquid obtained in step 2 to the spin columns FL that have been loaded into the collection tube, centrifuge at 12000 rpm (~13400 × g) for 2 minutes, and transfer the supernatant from the collection tube to a new centrifuge tube (provided by oneself).Attention:1) When aspirating liquid, the tip of the gun can be cut off for easy sampling.2) Spin Columns FL can remove most of the fragments, but there will still be a small amount flowing out. After centrifugation, precipitation will form in the collection tube. When proceeding to the next step, be careful not to absorb the sediment.4. Add 0.5 times the volume of anhydrous ethanol to the clean cracking solution obtained in step 3 and quickly mix well. Attention: Adding ethanol may cause precipitation, but it does not affect subsequent experiments.5. Add all the solutions obtained in step 4 to the spin columns RM that have been loaded into the collection tube. If it is not possible to add all the solutions to the adsorption column at once, please transfer them in two separate steps. Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.6. Add 700 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube. Optional steps: If conducting RNA experiments that are highly sensitive to trace amounts of DNA, replace step 6 with the following steps.1) Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 15 seconds, discard the waste liquid, and place the adsorption column back into the recovery manifold.2) Preparation of DNase I mixture: Take 52 µ Add 8 RNase Free Water to it µ 10 x Reaction Buffer and 20 µ DNase I (1 U/ µ l) Mix well and prepare to a final volume of 80 µ The reaction solution of L.Attention:The above system is configured according to our company's DNase I reaction system. Please refer to the corresponding instructions for other company products.3) Add 80 µ l of DNase I reaction solution directly to the adsorption column and incubate at 20-30 ℃ for 15 minutes.4) Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 15 seconds, discard the waste liquid, and place the adsorption column back into the recovery manifold.7. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 15 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.8. Repeat step 7.Centrifuge at 9.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly dry the anhydrous ethanol in the column.Attention:The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).10. Place the adsorption column in a new RNase free centrifuge tube, and add 30-50 to the middle of the adsorption column in the air µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 10 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 10... Read More |