| Description | This reagent kit uses an adsorption column that can specifically bind to viral RNA and a unique buffer system, suitable for isolating viral RNA from cell-free body fluids such as serum, plasma, urine, cerebrospinal fluid, and cell culture supernatants. The viral RNA specifically binds to the siliconThis reagent kit uses an adsorption column that can specifically bind to viral RNA and a unique buffer system, suitable for isolating viral RNA from cell-free body fluids such as serum, plasma, urine, cerebrospinal fluid, and cell culture supernatants. The viral RNA specifically binds to the silicon substrate membrane, and pollutants flow through the membrane. Completely remove impurities such as proteins through two efficient washes, and then wash high-purity viral RNA with RNase free water or RNase Free Water provided by the reagent kit. The virus RNA extracted by this kit can be directly used for experiments such as RT-PCR, Real time RT-PCR, and Western blot analysis. R666005Component50 TStorageR666005ABuffer GL15 mLRTR666005BBuffer RW140 mLRTR666005CBuffer RW2(concentrate)11 mLRTR666005DProteinase K12.5 mgRTR666005EProteinase K Storage Buffer1.25 mLRTR666005FRNase-Free Water10 mLRTR666005GSpin Columns RS with Collection Tubes50 setsRTR666005HRNase-Free Centrifuge Tubes(1.5 mL)50 EART Self prepared reagent: anhydrous ethanol, 0.9% NaCl.Preparation and important precautions before the experiment1. Add 1.25 ml of Protein K Storage Buffer to Protein K to dissolve it and store at -20 ℃. The prepared Protein K should not be left at room temperature for a long time to avoid repeated freeze-thaw cycles, which may affect its activity.2. To prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.3. Serum or plasma should avoid repeated freeze-thaw cycles that may cause protein denaturation or precipitation, reduce viral titers, and thus affect the yield of extracted viral nucleic acids.4. Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. If buffer GL precipitates, it can be heated at 56 ℃ to dissolve and then placed at room temperature.6. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Operation steps1. Take 200 at room temperature µ Add serum or plasma to a 1.5 ml centrifuge tube (self provided). Attention: Less than 200 µ 0.9% NaCl (provided by the customer) can be added to make up for it.2. Add 20 to the solution in the previous step µ Protein K, mix well.3. Add 200 µ L Buffer GL, vortex oscillation for 15 seconds. Note: Do not directly add Protein K to Buffer GL. 4. Incubate at 56 ℃ for 15 minutes, briefly centrifuge, and collect the solution on the tube wall to the bottom of the tube.5. Add 250 µ Anhydrous ethanol, vortex for 15 seconds, incubate at room temperature for 5 minutes, briefly centrifuge, and collect the solution from the tube wall to the bottom of the tube.6. Add all the solution obtained in step 5 to the Spin Columns RS that have been loaded into the collection tube. If it is not possible to add all the solution to the adsorption column at once, please transfer it in two batches, centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and put the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.8. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.9. Add 500 to the adsorption column µ Centrifuge anhydrous ethanol at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube. 10. Centrifuge at 12000 rpm for 3 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Attention:1) The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).2) Recommended steps: Place the adsorption column into a new 1.5 ml centrifuge tube (provided), open the tube cover, and incubate in a 56 ℃ oven for 3 minutes to thoroughly dry the membrane of the adsorption column.11. Place the adsorption column in a new RNase free centrifuge tube and add 20-50 to the middle of the adsorption column in the air µ Place RNase Free Water at room temperature for 5 minutes, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 20 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 20-50 µ Repeat step 11 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 11... Read More | DescriptionCholesteryl ester transfer protein (CETP) is present in normal human plasma and transfers neutral lipids from high density lipoproteins (HDL) to very low density lipoprotein (VLDL) and low density lipoprotein (LDL). CETP plays an important role in lipoprotein metabolism and influences theDescriptionCholesteryl ester transfer protein (CETP) is present in normal human plasma and transfers neutral lipids from high density lipoproteins (HDL) to very low density lipoprotein (VLDL) and low density lipoprotein (LDL). CETP plays an important role in lipoprotein metabolism and influences the reverse cholesterol transport pathway.Preparation instructionsSuitable for high-throughput screening (HTS), mechanism of action (MOA) studies, and structure-activity relationship (SAR) work in CETP sources.PrincipleThe CETP RP Activity Assay uses a proprietary substrate that enables the detection of CETP-mediated neutral lipid mass transfer. The method is useful for measuring CETP activity in recombinant protein (RP) or purified CETP samples and has a high D... Read More | Inquire | Product Content D669986Component50 TStorageD669986ABuffer SA15 mLRTD669986B2×PCR MasterMix1 mL-20℃. Avoid freeze/thaw cycle.D669986CProteinase K12.5 mgRTD669986DProteinase K Storage Buffer1.25 mLRTProductsThis kit adopts a unique buffer system containing all the reagents for rapid Product Content D669986Component50 TStorageD669986ABuffer SA15 mLRTD669986B2×PCR MasterMix1 mL-20℃. Avoid freeze/thaw cycle.D669986CProteinase K12.5 mgRTD669986DProteinase K Storage Buffer1.25 mLRTProductsThis kit adopts a unique buffer system containing all the reagents for rapid preparation of genomic DNA and PCR amplification, and is suitable for one-step extraction of genomic DNA from various plant and animal tissues and bacteria and for PCR amplification. The whole extraction process does not require liquid nitrogen grinding, organic solvent extraction, anhydrous ethanol precipitation, and the quality of extracted DNA is stable. The 2×PCR MasterMix provided in this kit is a highly compatible PCR reagent that can amplify DNA samples efficiently and specifically, which includes DNA polymerase, dNTPs, MgCl2, reaction buffer, PCR reaction enhancer and so on. It is characterized by fast and easy, high sensitivity, high specificity, good stability, etc. It is especially suitable for high throughput screening.Pre-experiment Preparation and Important Notes1. Add the specified amount of Proteinase K Storage Buffer to Proteinase K to dissolve it and store it at -20℃. Do not leave the prepared Proteinase K at room temperature for a long time, and avoid repeated freezing and thawing to avoid affecting its activity.2. Repeated freezing and thawing of the samples should be avoided, as this will result in smaller DNA fragments and a decrease in the amount of extracted DNA.3. Before use, please check Buffer SA for crystallization or precipitation. If crystallization or precipitation occurs, please re-dissolve Buffer SA in a 56℃ water bath.4. The PCR MasterMix provided with this product is 2×, when using it, you need to add template and primer, and add RNase-Free Water to make up the volume, so that its concentration is 1× to carry out the reaction.Procedure1. Fetch:Plant material: take about 10 mg of sample in a centrifuge tube (provided); Animal material: take about 10 mg of sample in a centrifuge tube (provided);Bacteria: Take 200-800 µL of bacteria in good growth condition in a centrifuge tube (self-provided) and collect the bacteria.2. Add 200 µL of Buffer SA and vortex to mix.Note: In the case of plant leaves and animal tissues, they should be ground with a pestle and mortar as much as possible: in the case of plant seeds, they should be crushed and finely ground beforehand; bacterial and 1-3 mm rat-tail samples can be directly vortex lysed.3. Add 10µL of Proteinase K, mix well, incubate at 56℃ for 10 minutes, and treat at 95℃ for 5 minutes.Note: 1) In the case of animal tissue samples, the incubation time at 56°C may be extended to 30 minutes as appropriate; if there is any incompletely digested tissue, it should be removed as thoroughly as possible after centrifugation in the next step.2) Be careful not to exceed 5 minutes when treating at 95°C.4. 13,000 rpm (~17,900 x g), centrifugation for 5 minutes.5. Transfer the supernatant to a new centrifuge tube (self-prepared) and use it directly for PCR amplification, or store the solution at 4℃ or -20℃.6. PCR amplification:1) PCR reaction system:The following examples are conventional PCR reaction systems and reaction conditions, which should be improved and optimized according to the template, primer structure and target fragment size in actual operation.reagents20 µL systemfinal concentration2×PCR MasterMix10 µL1×Forward Primer, 10 µM1 µL0.4 µMReverse Primer, 10 µM1 µL0.4 µMTemplate DNA1-2 µL RNase-free Waterup to 20 µLNote: Please use the final concentration of 0.2-0.6µM as a reference for setting the range of primer concentration. If the amplification efficiency is not high, the concentration of primer can be increased; if a non-specific reaction occurs, the concentration of primer can be decreased, thus optimizing the reaction system.2)PCR reaction conditions:movetemptimingpremutability94°C2mindenaturation94°C30sannealing (metallurgy)55-65°C30s30-40 cyclesreach72°C60sultimate extension72°C5minNote: 1) In general, the annealing temperature is 5℃ lower than the melting temperature of the amplification primer Tm, and the annealing time is generally 30-60 seconds. When the desired amplification efficiency cannot be obtained, the annealing temperature should be lowered appropriately; when a non-specific reaction occurs, the annealing temperature should be raised, thus optimizing the reaction conditions.(2) The extension time is set according to the size of the fragment to be amplified, and the amplification efficiency of Taq DNA Polymerase included in this product is 1kb/30s. 3) The number of cycles can be set according to the downstream application of the amplification product. If the number of cycles is too low, the amplification is insufficient; if the number of cycles is high, the chance of mismatch will increase and the non-specific background will be serious. Therefore, the number of cycles should be minimized under the premise of ensuring the product yield.(3) Result detection: 5 µL of reaction product was taken at the end of the reaction and directly detected by agarose gel electrophoresis... Read More | The perfect KitAlysis Labware starter kit that combines the KitAlysis Inertion Box (Z742064) with the KitAlysis 24-Well Reaction Block and Screwdriver Set (Z742107).Provides an inert environment to run oxygen sensitive cross-coupling reactions in a laboratory fume hood.Designed to be used with The perfect KitAlysis Labware starter kit that combines the KitAlysis Inertion Box (Z742064) with the KitAlysis 24-Well Reaction Block and Screwdriver Set (Z742107).Provides an inert environment to run oxygen sensitive cross-coupling reactions in a laboratory fume hood.Designed to be used with KitAlysis High-Throughput Screening Kits.Components:Ιnertion Box24-Well Reaction BlockTorque Screwdriver set with bitReaction Block Replacement Screws (10ea)... Read More |