| Description | Product DescriptionAcetyl esterase (sialate-O-acetylesterase) is a recombinant protein from Tannerella forsythia, ATCC 43037 strain, expressed in Escherichia coli. The enzyme removes acetyl groups attached via an O- group, mainly 9-, 8- and 7-. It can be used for monitoring of diacetylation of Product DescriptionAcetyl esterase (sialate-O-acetylesterase) is a recombinant protein from Tannerella forsythia, ATCC 43037 strain, expressed in Escherichia coli. The enzyme removes acetyl groups attached via an O- group, mainly 9-, 8- and 7-. It can be used for monitoring of diacetylation of sialic acids on products such as erythropoietin (EPO).The Zyme Acetyl Esterase Kit removes 9-, 8- and 7-O-acetyl groups from released sialic acids, released glycans or glycoproteins. It is commonly used for the characterization of highly-sialylated biotherapeutics such as EPO, FSH and blood clotting factors.Molecular Weight76.3 kDContentsAcetyl esterase – PBS pH7.5 buffer containing 10 mM Tris-HClReaction Buffer – 500 mM sodium acetate pH5.5Number of SamplesSufficient for up to 50 samples.Amount of SampleUp to 10 µg glycoprotein, up to 2.5 µg released glycans and up to 1 µg free sialic acid per digestion.Suitable SamplesAcetyl esterase (sialate-O-acetylesterase) can act upon complex glycoprotein samples, such as erythropoietin (EPO), bovine submaxillary mucin and oral epithelial cell-bound glycans, and on N- and O-glycans released from a glycoprotein. Either fluorescently labelled or unlabelled glycans are suitable. It can also be used on released sialic acids.Unit DefinitionOne unit (U) of acetyl esterase is defined as the amount of enzyme required to produce 300 µmole of 4-nitrophenol and acetate in 1 minute at 30°C in a buffer containing 50 mM Tris-HCl, 140 mM NaCl, pH 8.5, from 4-nitrophenyl acetate, a chromogenic esterase substrateStorageProtect from sources of heat and light. When stored correctly, the enzyme should be stable for 24 months from date of purchase. Exposure to ambient temperatures (20 – 26°C) over 3 days does not result in a reduction of enzymatic activity.ShippingThe product should be shipped at 4°C.HandlingEnsure that any glass, plastic ware or solvents used with this item are free of environmental carbohydrates. Use powder-free gloves for all sample handling procedures and avoid contamination with environmental carbohydrate.SafetyPlease read the Safety Data Sheets (SDSs) for all chemicals used. All processes involving labelling reagents should be performed using appropriate personal safety protection – safety glasses, chemically resistant gloves (e.g. nitrile), lab coat, and when appropriate, in a laboratory fume cupboard.For research use only. Not for human or drug use ApplicationAcetyl esterase (sialate-O-acetylesterase) can be used to remove 9-, 8- and 7-O-acetyl groups from released sialic acids, released glycans or glycoproteins... Read More | Products contentProducts IntroductionThis product uses the principle that the difference between the concentration of salt ions inside and outside the cell can cause the cell membrane to burst to lyses the cell and releases the genomic DNA, without the need of extracting and purifying the genomic Products contentProducts IntroductionThis product uses the principle that the difference between the concentration of salt ions inside and outside the cell can cause the cell membrane to burst to lyses the cell and releases the genomic DNA, without the need of extracting and purifying the genomic DNA.This product is suitable for a variety of sources of samples, and can be used as a template for PCR and qPCR experiments after sample processing, and can achieve the effect of the purified DNA used as a template for PCR and qPCR experiments. Usage1. Depending on the type of sample, prepare the appropriate sample size according to the table below.2. Add the sample to a 1.5-mi centrifuge tube and add the recommended volume of Solution A as shown in the table below. Vortex for 20 s and allow to stand at room temperature for 3-5 min or incubate in a metal bath at 95°C for 3-5 min as recommended in the table below.3. After the sample has been sufficiently lysed (samples incubated in a metal bath at 95°C should be brought to room temperature), add the recommended volume of Solution B as shown in the table below and vortex for 30s.4. Store processed samples at 4°C if the next test is to be performed within 2 hours, or at -20°C if the next test cannot be performed immediately.take note of1) Depending on the requirements of the experimental conditions, the amount of samples can be expanded or reduced, and the amount of Solution A and Solution B can be increased in equal proportions.2) For blood and cell samples, the temperature of room temperature lysis is required to be around 25C. If the ambient temperature does not reach 25°, the lysis time can be extended appropriately, or the vortex shaking time can be extended to ensure that the samples are fully lysed. If there is no relevant professional instrument, the centrifuge tube can be shaken vigorously to ensure adequate lysis.3) After the tissue sample is made into tissue homogenate by adding 10 times the volume of saline, it can be processed in the same way as blood samples.4) Strictly prohibit the use of expired products, please do not mix different reagents.5) laboratory supplies should be regularly cleaned and 10% of the 84 disinfectant solution or ultraviolet lamp for anti-pollution treatment, special areas dedicated to prohibit cross use, so as to avoid contamination, the end of the test, the bench should be cleaned immediately... Read More | Product content: Component S665549 50 preps Buffer SW 60 ml Buffer SL 60 ml Buffer GL 50 ml Buffer GW1(concentrate) 2X13 ml Buffer GW2(concentrate) 15 ml Buffer GE 15 ml Spin Columns DM 50 with Collection Tubes 50Product IntroductionThis kit is suitable for Product content: Component S665549 50 preps Buffer SW 60 ml Buffer SL 60 ml Buffer GL 50 ml Buffer GW1(concentrate) 2X13 ml Buffer GW2(concentrate) 15 ml Buffer GE 15 ml Spin Columns DM 50 with Collection Tubes 50Product IntroductionThis kit is suitable for extracting total DNA from fecal samples, including the total DNA of cells, bacteria, parasites, and viruses in the samples, as well as samples containing high concentrations of PCR reaction inhibitors. This product can process up to 300 mg of fecal samples and purify to obtain mainly 20-30 kb DNA fragments. The purification process does not require toxic solvents such as phenol or chloroform, and does not require ethanol precipitation. High purity DNA can be obtained within one hour. This reagent kit adopts a unique buffering system to efficiently bind DNA from the lysis solution to the adsorption column. At the same time, protein impurities and other organic compounds that inhibit downstream reactions in feces can flow through the membrane. Inhibitors of PCR and enzyme reactions, as well as residual impurities, can be effectively removed through two washing steps. Finally, high-purity DNA can be obtained by washing with low salt buffer or water. The purified DNA can be directly used for downstream experiments such as enzyme digestion, PCR, Real Time PCR, library construction, Southern Blot, and molecular labeling.Preparation and important precautions before the experiment1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.Before the first use, anhydrous ethanol should be added to Buffer GW1 and GW2 according to the instructions on the reagent bottle label.3. Before use, please check whether there is crystallization or precipitation in Buffer SL and Buffer GL. If there is crystallization or precipitation, please dissolve Buffer SL and Buffer GL again in a 56 ℃ water bath.4. If downstream experiments are sensitive to RNA contamination, 4 can be added after adding Buffer SL µ RNase A of DNase Free (100 mg/ml) is not provided in this kit. If needed, it can be ordered separately from our company, item number: S665549Operation steps1. Take a fecal sample of 100-300 mg and place it in a centrifuge tube (provided by oneself).2. Add 1 ml of Buffer SW and vortex for 3-5 minutes to evenly disperse the sample in the solution. Centrifuge at 12000 rpm (~13400 × g) for 1 minute and discard the supernatant.3. Add 1 ml of Buffer SL and vortex for 3-5 minutes to evenly disperse the sample in the solution. Take a water bath at 65 ℃ for 20 minutes and vortex for 15 seconds every 5 minutes. Note: To remove RNA, add 4 after completing the above steps µ RNase A solution (product number: CW0601S) with a concentration of 100 mg/ml, shake well and let stand at room temperature for 5-10 minutes.4.Centrifuge at 2000 rpm for 3 minutes and transfer the supernatant to a new centrifuge tube (provided by oneself).5. Add an equal volume of Buffer GL to the supernatant, invert and mix 15-25 times, and leave on ice for 5 minutes. Centrifuge at 12000 rpm for 5 minutes. Attention: At this time, the liquid may be in a transparent or turbid state, which does not affect the experiment. 6. Add the supernatant obtained in step 5 to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. 8. Repeat step 7.9. Add 500 to the adsorption column µ Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.10.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self provided) and add 50-100 drops of suspended droplets to the middle of the adsorption column µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Note: 1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency will be reduced2) Incubating at room temperature for 5 minutes before centrifugation can increase yield.3) Use an additional 50-100 µ Further washing with buffer GE or sterilized water can increase yield.4) If you want to increase the final concentration of DNA, you can add the DNA eluent obtained in step 11 back onto the adsorption membrane and repeat step 11; It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with buffer GE or sterilized water.5) DNA stored in water can be affected by acidic hydrolysis. If long-term storage is required, it is recommended to elute with Buffer GE and store at -20 ℃.6) The residual trace PCR inhibitors in the genomic DNA template may have adverse effects on the PCR reaction, which can be solved by diluting DNA by 2-10 times... Read More | DescriptionThe Universal Coupling Kit makes particle-based immunoassays, lateral flow tests and biomolecule separation applications more flexible than ever before. It is the only kit that allows users to select and couple their choice of carboxylated particle with their chosen protein.Employing a DescriptionThe Universal Coupling Kit makes particle-based immunoassays, lateral flow tests and biomolecule separation applications more flexible than ever before. It is the only kit that allows users to select and couple their choice of carboxylated particle with their chosen protein.Employing a unique mechanism to immobilise proteins, Anteo′s advantages outweigh those of conventional covalent chemistries such as NHS/EDC or passive binding. This facilitates coupling of antibodies with ease, improved functionality and reproducibility, leading to better uniformity between experiments.Anteo′s Activation Reagent is water-based and replaces the dry chemicals you would use with the traditional NHS/EDC method. Our One-Step-Activation only takes one hour, and improves efficiency in terms of both time and cost. It also provides the ability to either store activated particles up to 12 months for later use, or to immediately couple proteins.Particle-Based Immunoassays, Lateral Flow, Bioseparations and Immunoprecipitation... Read More | V669947 Component 50T Storage V669947A Buffer GL 15 mL RT V669947B Buffer GW1 (concentrate) 13 mL RT V669947C Buffer GW2 (concentrate) 15 mL RT V669947D Buffer RE 10 mL RT V669947E Proteinase K 12.5 mg RT V669947F Proteinase K Storage Buffer 1.25 mL RT V669947G Spin Columns RS with Collection Tubes V669947 Component 50T Storage V669947A Buffer GL 15 mL RT V669947B Buffer GW1 (concentrate) 13 mL RT V669947C Buffer GW2 (concentrate) 15 mL RT V669947D Buffer RE 10 mL RT V669947E Proteinase K 12.5 mg RT V669947F Proteinase K Storage Buffer 1.25 mL RT V669947G Spin Columns RS with Collection Tubes 50 RT V669947H RNase-Free Centrifuge Tubes (1.5 mL) 50 RTProductsThis kit is suitable for the extraction of viral RNA and DNA from fresh or frozen plasma, serum and cell-free body fluids. It is easy to operate as it does not require the use of organic solvents such as phenol and chloroform for extraction. The kit uses a unique buffer system to enable efficient and specific binding of viral nucleic acids in lysate to silica gel centrifugal adsorption columns. Inhibitors of PCR and enzyme reactions as well as residual impurities can be efficiently removed in a two-step effective rinsing step, and finally high purity viral nucleic acids can be obtained by using a low-salt buffer or water for elution. The purified viral nucleic acid is free of protein, nuclease and other impurities, and can be used directly in PCR, RT-PCR, Real-Time PCR, blotting experiments and so on.Self-contained reagent: anhydrous ethanol.Pre-experiment and Important Notes1. Add 1.25ml Proteinase K Storage Buffer to Proteinase K to dissolve it and store it at -20℃. Do not leave the prepared Proteinase K at room temperature for a long time, and avoid repeated freezing and thawing to avoid affecting its activity. Do not add Proteinase K directly into Buffer GL.2. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller DNA fragments and a decrease in the amount of extracted DNA.3. Avoid repeated freezing and thawing of serum or plasma, which can lead to protein denaturation or precipitation, reducing the viral titer and thus affecting the yield of extracted viral nucleic acids.4. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the label instructions of the reagent bottle before first use.5. Check Buffer GL for crystallization or precipitation before use. If crystallization or precipitation occurs, redissolve Buffer GL in a water bath at 56℃.Procedure1. Take a 1.5 ml centrifuge tube (self-provided) and add 20 µl Proteinase K.2. Add 200 µl serum or plasma to the centrifuge tube. Add 200µl Buffer GL and vortex and shake for 15 seconds.Note: 1) Sample volume less than 200 µl can be made up by adding 0.9% NaCl (self-provided). 2) In order to ensure effective lysis of the sample, the sample needs to be mixed well with Buffer GL after adding Buffer GL.3. Incubate at 56°C for 15 minutes, centrifuge briefly, and collect the solution from the wall of the tube to the bottom of the tube.4. 250 µl of anhydrous ethanol was added, vortexed and shaken for 15 seconds, left at room temperature for 5 minutes, centrifuged briefly, and the solution on the wall of the tube was collected at the bottom of the tube.Note: If the ambient temperature exceeds 25°C, anhydrous ethanol should be used after pre-cooling on ice.5. Add the solution obtained in step 4 to the adsorbent column (RNase-Free Columns RS) that has been loaded into the collection tube, and if the solution cannot be added at one time, it can be transferred in several times. centrifuge the column at 12,000 rpm (~13,400 × g) for 1 min, pour off the waste liquid in the collection tube, and put the column back into the collection tube.6. Add 500 µl of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.7. Add 500 µl of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Add 500 µl of anhydrous ethanol to the adsorbent column and centrifuge at 12,000 rpm for 1 min. Pour off the waste liquid in the collection tube and put the adsorbent column back into the collection tube.9. Centrifuge at 12,000 rpm for 3 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is the removal of residual ethanol from the adsorbent column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).10. Place the adsorption column in a new collection tube (RNase-Free Centrifuge Tube), add 20-150 µl of Buffer RE or sterilized water overhanging the middle of the adsorption column membrane, leave it at room temperature for 2-5 minutes, and then centrifuge it at 12,000 rpm for 1 minute to collect the nucleic acid solution.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH of the eluent has a great influence on the elution efficiency, if water is used as the eluent it should be ensured that its pH is 7.0-8.5 (the pH of water can be adjusted to this range with NaOH), and the elution efficiency is not high when the pH is lower than 7.0.(2) For long-term storage, please store the DNA solution at -20℃ and the RNA solution at -70℃.3) If the final concentration of DNA/RNA is to be increased, the DNA/RNA eluate obtained in step 10 can be re-spiked onto the adsorbent membrane and step 10 repeated... Read More |