| Description | Inquire | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | B669951 Component 50T Storage B669951A Buffer ATL 15 mL RT B669951B Buffer AL 15 mL RT B669951C Buffer AW1 (concentrate) 13 mL RT B669951D Buffer AW2 (concentrate) 15 mL RT B669951E Buffer EB 15 mL RT B669951F Proteinase K 1.25 mL RT B669951G Spin Columns DM with Collection Tubes 50 sets B669951 Component 50T Storage B669951A Buffer ATL 15 mL RT B669951B Buffer AL 15 mL RT B669951C Buffer AW1 (concentrate) 13 mL RT B669951D Buffer AW2 (concentrate) 15 mL RT B669951E Buffer EB 15 mL RT B669951F Proteinase K 1.25 mL RT B669951G Spin Columns DM with Collection Tubes 50 sets RTProductsThis kit is suitable for extracting high purity total DNA from Gram-negative and Gram-positive bacteria. 106-108 cells can be processed at a time, and up to 20 µg of total DNA can be obtained within one hour without the need for toxic solvents such as phenol or chloroform, and without the need for ethanol precipitation. The optimized buffer system enables the DNA in the lysate to be efficiently and specifically bound to the silica matrix centrifugal adsorption column, while other contaminants can flow through the membrane, and the inhibitors of PCR and other enzymatic reactions can be effectively removed through a two-step washing step, and finally washed off with low-salt buffer or water, so that high-purity DNA can be obtained.The purified DNA can be used for downstream experiments such as digestion, PCR, Real-Time PCR, library construction, Southern Blot and molecular labeling, molecular labeling and other downstream experiments. Self-contained reagents: anhydrous ethanol; Enzymatic Lysis Buffer is required for extraction of Gram-positive bacteria.Enzymatic Lysis Buffer was prepared by 20 mM Tris, pH 8.0; 2 mM Na2-EDTA, pH 8.0; and 1.2% Triton X-100. 121°C sterilization for 20 minutes, and the appropriate amount of Lysozyme was added at a final concentration of 20 mg/ml. Pre-experiment Preparation and Important Notes1. Add 1.25ml Proteinase K Storage Buffer to Proteinase K to dissolve it and store it at -20℃. Do not leave the prepared Proteinase K at room temperature for a long time, and avoid repeated freezing and thawing to avoid affecting its activity.2. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller DNA fragments and a decrease in the amount of extracted DNA.3. If extracting genomes from bacterial cultures with high accumulation of secondary metabolites or thick cell walls, it is recommended that samples be collected early in the logarithmic phase.4. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.5. Before use, please check Buffer GTL and Buffer GL for crystallization or precipitation. If crystallization or precipitation occurs, please re-dissolve Buffer GL and Buffer GTL in a 56℃ water bath.6. If the downstream experiments are sensitive to RNA contamination, 4µl of DNase-Free RNase A (100mg/ml) can be added before adding Buffer GL. RNase A is not provided in this kit.If the extracted samples are Gram-positive bacteria, customers need to prepare their own Enzymatic Lysis Buffer to treat the bacteria, which requires the use of Lysozyme (lysozyme) at a concentration of 20 mg/ml, which is not provided in this kit.Procedurei Extraction of genomic DNA from Gram-negative bacteria1. Take 1-5 ml of bacterial culture (106-108 cells, maximum 2×109 cells) and put it into a centrifuge tube (provided), centrifuge it at 12,000 rpm (~13,400×g) for 1 minute, and aspirate the supernatant as much as possible.2. Add 180 µl Buffer GTL to the precipitate and shake to resuspend the bacteria.3. Add 20 µl of Proteinase K, vortex and mix well, incubate at 56°C until the solution becomes clear, and invert or shake the centrifuge tube at intervals during the incubation to disperse the sample.Note: If RNA removal is required, add 4 µl of RNase A solution at a concentration of 100 mg/ml after the above steps are completed, shake to mix, and leave for 5-10 minutes at room temperature.4. Add 200µl Buffer GL and mix well with vortexing and shaking. Add 200µl of anhydrous ethanol and mix well with vortexing and shaking.Centrifuge briefly so that the solution on the walls of the tube collects at the bottom.Note: 1) If multiple samples are manipulated together, Buffer GL and anhydrous ethanol can be mixed in equal proportions and then added together, shaking to mix.2) The addition of Buffer GL and anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.5. Add all of the solution obtained in step 4 (including the precipitate formed) to the Spin Columns DM in the collection tube, or if the solution cannot be added all at once, transfer it several times. centrifuge at 12,000 rpm for 1 minute, discard the waste solution, and return the column to the collection tube.6. Add 500 µl of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and return the adsorption column to the collection tube.7. Add 500 µl of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorbent column at room temperature for several minutes to dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorbent column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new centrifuge tube, add 50-200 µl Buffer GE to the middle part of the adsorption column overhanging the center of the adsorption column, leave it at room temperature for 2-5 minutes, centrifuge it at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20 ℃. note: 1) If the downstream experiments are sensitive to the pH or EDTA, the elution can be done with sterilized water. The pH of the elution solution has a great influence on the elution efficiency. If water is used as the elution solution it should be ensured that its pH is 7.0-8.5 (the pH of water can be adjusted to this range with NaOH), and the elution efficiency is not high when the pH is lower than 7.0.2) Incubation at room temperature for 5 minutes prior to centrifugation increases yield.3) Re-elution with an additional 50-200 µl Buffer GE or sterilized water can increase the yield.4) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 9 can be re-spiked onto the adsorbent membrane and step 9 repeated; if the elution volume is less than 200 µl, the final concentration of DNA can be increased, but the total yield may be reduced. If the amount of DNA is less than 1 µg, elution with 50 µl Buffer GE or sterilized water is recommended.(5) DNA stored in water will be affected by acidic hydrolysis. For long-term storage, it is recommended to elute with Buffer GE and store at -20℃.i. Extraction of genomic DNA from Gram-positive bacteria1. Take 1-5 ml of bacterial culture (106-108 cells, maximum 2×109 cells) and put it into a centrifuge tube (provided), centrifuge it at 12,000 rpm (~13,400×g) for 1 minute, and aspirate the supernatant as much as possible.2. Add 180µl Enzymatic Lysis Buffer (self-provided) to resuspend the bacteria.Enzymatic Lysis Buffer is prepared as described in the Self-Prepared Reagents section in the front of the manual.3. Incubate at 37°C for 30 minutes.4. Add 20µl Proteinase K and mix well. Add 200µl of Buffer GL and mix well with vortexing and shaking.Note: Do not add Proteinase K directly to Buffer GL.Incubate at 5.56°C for 30 minutes.Note: 1) If desired, incubation at 95°C for 15 minutes will inactivate the pathogen, but 95°C incubation will cause some DNA degradation.(2) If RNA removal is required, add 4µl of RNase A solution at a concentration of 100mg/ml after the above steps are completed, shake and mix well, and leave for 5-10 minutes at room temperature.6. Add 200µl of anhydrous ethanol and mix well with vortex shaking.Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.7. Add all of the solution obtained in step 6 (including the precipitate formed) to the Spin Columns DM that have been loaded into the collection tube, and if the solution cannot be added all at once, it can be transferred in several times. centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid from the collection tube, and put the column back into the collection tube.8. Add 500 µl of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.9. Add 500 µl Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge the column at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the column back into the collection tube.Note: Step 9 can be repeated if further DNA purity is required.10. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self-provided), add 50-200 µl of Buffer GE to the center of the adsorption column overhanging the center of the adsorption column, let it stand at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20℃.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH is 7.0-8.5 (you can use NaOH to adjust the pH of the water to this range), and the elution efficiency is not high when the pH is lower than 7.0.2) Incubation at room temperature for 5 minutes prior to centrifugation increases yield.3) Re-elution with an additional 50-200 µl Buffer GE or sterilized water can increase the yield.4) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 11 can be re-spiked onto the adsorbent membrane and step 11 repeated; if the elution volume is less than 200 µl, the final concentration of DNA can be increased, but the total yield may be reduced. If the amount of DNA is less than 1 µg, elution with 50 µl Buffer GE or sterilized water is recommended.(5) DNA stored in water will be affected by acidic hydrolysis. For long-term storage, it is recommended to elute with Buffer GE and store at -20℃... Read More | Live & deadtm animal cell viability / toxicity detection kit (calcein am, ethd-i) is a kit that provides double fluorescent staining for the detection of animal cell death and survival. The two probes in the kit can respectively measure the activity of cellular lactonase and the integrity of Live & deadtm animal cell viability / toxicity detection kit (calcein am, ethd-i) is a kit that provides double fluorescent staining for the detection of animal cell death and survival. The two probes in the kit can respectively measure the activity of cellular lactonase and the integrity of plasma membrane to reflect cell viability. The kit can be used for fluorescence microscopy, flow cytometry, microplate reader and other fluorescence detection systems. This kit can be applied to most eukarYOtic mammalian cells, including some tissues with adherent nuclei, but it is not applicable to fungi and yeast. Compared with trypan blue, the kit is faster, safer and more sensitive.Component: Product parameters:Calcein am: ex/em = 494 / 517 nm; Ethd-i: ex/em = 528 / 617 nm (bound DNA)Usage:Fluorescence microscopy detection1. Prepare working fluidPreparation 2 µ M Calcein AM and 4 µ M EthD-I staining solution: Remove the original solution of Calcein AM and EthD-I and restore them to room temperature. Add 20 µ L 2 mM EthD-I and 5 µ Mix 4 mM Calcein AM with 10 mL PBS or other serum-free buffer or culture medium, vortex well. The above working solution can be directly used for cell staining.Note: The aqueous solution of Calcein AM is easily hydrolyzed and should be used up every day. The concentration selection of Calcein AM and EthD-I varies depending on the type of cell used, with a recommended concentration range of 0.1-10 µ M.2. Prepare cells and conduct experiments(1) For adherent cells, they can be washed 2-3 times with 1 × PBS before staining. For suspended cells, centrifuge at room temperature of 250-1000 × g for 5 minutes and collect cells for staining.(2) Wash the cells thoroughly 2-3 times with 1 × PBS to remove residual esterase activity.(3) For adherent cells, add sufficient amount of Calcein AM/EthD-I staining solution. For suspended cells, add an appropriate amount of staining solution to control the cell density between 1-5 × 105/mL.(4) Incubate at room temperature in dark for 15-20 minutes (if the working solution concentration is high or the incubation temperature is high, the incubation time should be appropriately reduced).(5) Observe the labeled cells under a fluorescence microscope.Flow cytometry detection1. Remove the reagent and restore it to room temperature.2. Preparation 2 µ M Calcein AM and 4 µ M EthD-I staining solution: Take out the original solution of Calcein AM and EthD-I, and restore to room temperature. Add 20 µ L 2 mMEthD-I and 5 µ Vortex mix 4 mM Calcein AM with 10 mL PBS or other serum-free buffer or culture medium. The working fluid can directly stain cells.3. Wash cells thoroughly 2-3 times with 1 × PBS.4. Suspend cells with 0.5 mL of staining solution and control the cell density to 1-5 × 105/mL.Note: It is recommended to prepare two additional cell samples, each containing only one dye (Calcein AM and EthD-I), for compensatory regulation of flow cytometry single staining; Prepare another cell sample containing only buffer solution (which should be consistent with the buffer used to prepare Calcein AM and EthD-I detection working solutions) as a negative control for flow cytometry analysis.5. Incubate at room temperature in dark for 15-20 minutes.6. Within 1-2 hours, cell activity was detected by flow cytometry. Calcein AM can be excited by a 488 nm laser, with fluorescence emission spectra detected at around 530 nm and EthD-I emission spectra at around 610 nm.Note: When using the cell circle gate, attention should be paid to excluding cell debris and using a single staining tube to regulate compensation. Double staining tube flow cytometry should obtain two relatively independent cell populations: a live cell population displaying green fluorescence and a dead cell population displaying red fluorescence.ELISA reader detection1. Cultivate an appropriate amount of adherent or suspended cells in a 96 well black ELISA plate.Note: Dead cells can be obtained by treating cells with 1% saponin or 0.1-0.5% digitalis saponin for 10 minutes.2. Preparation 2 µ M Calcein AM and 4 µ M EthD-I staining solution:Remove the original solutions of Calcein AM and EthD-I and restore them to room temperature. Add 20 µ L 2 mM EthD-I and 5 µ Mix 4 mM Calcein AM 10 mL PBS or other serum-free buffer or culture medium, vortex well.Note: (1) 10 mL of staining solution is sufficient to stain a 96 well plate, and the volume of the staining solution can be adjusted according to experimental needs. The concentrations of Calcein AM and EthD-I can range from 0.1 to 10 µ Explore between M.(2) The aqueous solution of Calcein AM is easily hydrolyzed and should be used up every day. EthD-I working solution can be stored at -20 ℃ for at least one year.3. Wash the cells thoroughly with 1 × PBS to remove residual esterase activity. For adherent cells, add 100 to each well µ Wash cells with PBS. For suspended cells, add 100 µ Resuspend cells with L PBS and centrifuge to remove the supernatant. Repeat the above operation.4. Add 100 to each hole µ L PBS.5. Add 100 to each hole µ L staining solution, making the total volume of each well 200 µ L. The final concentration of Calcein AM is 1 µ M. The final concentration of EthD-I is 2 µ M. Gently shake the culture plate to evenly cover the cells with the liquid.Incubate at room temperature in dark for 30-45 minutes.Note: The optimal incubation time varies for different cells, with 30 minutes as the initial incubation time. Subsequently, the staining time can be adjusted and optimized according to the actual staining effect to obtain a more ideal staining effect.7. Enzyme reader detection. When the ELISA reader is set to fluorescein, it can detect Calcein AM; When the ELISA reader is set to rhodamine or Texas Red, EthD-I can be detected. Select the optimal emission and excitation wavelengths based on spectral characteristics.Note: By comparing the relative fluorescence values (RFU) measured between the sample group and the control group, the changes in the number of dead and live cells can be obtained. Another method of data analysis is also provided below.The following method can calculate the ratio of live cells to dead cells in a certain region. The required samples include dead cell control group, live cell control group, and the sample group to be tested. Dead cells can be obtained by treating cells with 1% saponin or 0.1-0.5% digitalis saponin for 10 minutes.1. Prepare staining solution and follow the above steps to stain cells. Additionally, prepare 1 mL and 2 mL separately µ M Calcein AM and 4 µ M EthD-I solution, stain the control group according to the following instructions. For the following groups of cells or cell-free groups, it is necessary to maintain complete consistency in cell count, detection of working solution concentration, incubation time, and incubation temperature.2. Measurement of sample group and control group:A. The measured values of the sample group at 645 nm are denoted as Calcein AM and EthD-I=F (645) sam.B. The measured values of the sample group at 530 nm are denoted as Calcein AM and EthD-I=F (530) sam.C. The measurement value of dead cell EthD-I single staining control group at 645 nm is denoted as EthD-I=F (645) maxD. The measurement value of dead cell Calcein AM single staining control group at 645 nm is recorded as Calcein AM=F (645) minE. The measurement value of live cell EthD-I single staining control group at 530 nm is recorded as EthD-I=F (530) min.F. The measurement value of live cell Calcein AM single staining control group at 530 nm is denoted as Calcein AM=F (530) max.G. A blank control well without cells (with or without dye), the detection value at 530 nm is recorded as F (530) 0.H. A blank control well without cells (with or without dye), the detection value at 645 nm is recorded as F (645) 0.3. Calculate the ratio of dead cells to live cells based on measurement data:%Live Cells=(B-E) ÷ (F-E)%Dead Cells=(A-D) ÷ (C-D)Determine the ratio of live cells to dead cells in a certain areaBy creating fluorescence spectral standard curves at 530 nm and 645 nm, the number of dead and live cells can be determined, and the fluorescence intensity of each dye is linearly related to the number of dead or live cells in the sample.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. phenol red or serum may interfere with the detection of this kit. 3. fluorescent dyes have quenching problems. Please try to avoid light during experimental operation to slow down fluorescence quenching. 4. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Dead and live cell staining (animal)... Read More | Product content Q665687Component100 TStorageQ665687AQuick T4 DNA Ligase (15 U/µL)100 µL-20℃. Avoid freeze/thaw cycle.Q665687B2×Quick Ligation Reaction Buffer5×200 µL-20℃. Avoid freeze/thaw cycle. Product IntroductionThe Quick Ligation Reaction Kit allows ligationProduct content Q665687Component100 TStorageQ665687AQuick T4 DNA Ligase (15 U/µL)100 µL-20℃. Avoid freeze/thaw cycle.Q665687B2×Quick Ligation Reaction Buffer5×200 µL-20℃. Avoid freeze/thaw cycle. Product IntroductionThe Quick Ligation Reaction Kit allows ligation of DNA sticky or flush ends in 5 minutes at room temperature (25°C). The kit contains Quick T4 DNA Ligase and 2×Quick Ligation Reaction Buffer optimized for fast and efficient DNA ligation.The ligation efficiency of Quick Ligation is equivalent to 1 hour of conventional ligation with T4 DNA Ligase. The Quick Ligation products can be used directly in routine bacterial transformation experiments.matters needing attention1. This kit enables most of the linkage reactions to reach the reaction endpoint within 5 minutes or less at 25°C. Increasing the reaction time will not enhance the reaction efficiency. If you use the rapid connection reaction after 1 hour, the conversion efficiency will be significantly reduced; if the rapid connection reaction at 25 ℃ overnight, the conversion efficiency will drop to 75%.2. 2×Quick Ligation Reaction Buffer contains ATP, which should be thawed on ice and mixed thoroughly before use. It is recommended to freeze the buffer in small tubes for the first time, so as to avoid repeated freezing and thawing, which will affect the efficiency of DNA ligation.3. Since T4 DNA Ligase contains glycerol, which is sticky and easy to hang on the wall, it is recommended to collect the liquid to the bottom of the tube by centrifugation for a short period of time before use, and the tip of the lance should not go too deep into the liquid surface when taking samples to avoid sticking to the tip of the lance and causing losses.4. If the quick ligation product is used for electrotransformation, the PEG in the quick ligation reaction system will affect the efficiency of electrotransformation, and it is recommended to use a centrifugal column to purify the ligation product from DNA before electrotransformation.Usage1. The reaction solution was prepared according to the following system:*The amount of Insert DNA used: the molar ratio of Vector DNA and Insert DNA is generally 1:3-1:8, and the appropriate molar ratio of Vector DNA and Insert DNA can be selected according to the experimental situation.Calculation of DNA molar number: DNA molar number (nmol)=DNA mass (ng)/( 660daltons x number of inserted DNA bases bp).2. mix gently and centrifuge briefly. react at 25°C for 5 minutes.Note: The reaction time should not exceed 15 minutes, otherwise the connection efficiency will be reduced.3. Do not perform heat inactivation reactions. Centrifuge instantly and collect the solution from the wall to the bottom of the tube.Note: Heat inactivation significantly reduces transformation efficiency due to the presence of PEG in the buffer.4. After the reaction, store the DNA ligation product at 0-4℃, and then carry out transformation experiments; you can also store the DNA ligation product at -20℃.Note: When transforming by chemical method, do not add more than 10% of the volume of the receptor cell for the ligation product.5. Heat shock the ligation product to transform 50 µl of receptor cells or take 1-2 µl of ligation product to electroshock transform 50 µl of receptor cells.Note: 1) When transforming by chemical method, do not add more than 10% of the volume of the receptor cell for the ligation product.(2) If the quick ligation product is used for electrotransformation, it is recommended to use a centrifugal column to purify the ligation product from DNA before electrotransformation because the PEG in the quick ligation reaction system will affect the efficiency of electrotransformation... Read More |