Assay kits are used to carry out analyses in a broad scope of applications including the study of targets such as drugs, molecules, disease pathways, chemical elements or compounds, and organisms. They are a routine procedure in the modern pharmaceutical, medical and forensic world as well as research and university laboratories around the globe. Assay kits come with all the necessary reagents, instructions and protocols for fast and efficient processing, allowing for repeatable results.
|  |  |  |  |  |
| Company | Aladdin Scientific Corporation | Aladdin Scientific Corporation | Aladdin Scientific Corporation | Aladdin Scientific Corporation | Aladdin Scientific Corporation |
| Item | Nuclear and Cytoplasmic Protein Extraction Kit | Cell Senescence β-Galactosidase Staining Kit | Human BAFF/BLyS/TNFSF13B ELISA Kit | IROA TruQuant IQQ Workflow Kit | Quick DNA Extraction Kit |
| Catalog Number | N778382 | C1342264 | H1127430 | I485863 | Q665673 |
| Price | Supplier Page | Supplier Page | Supplier Page | Supplier Page | Supplier Page |
| Description | Inquire | Inquire | Inquire | DescriptionTruQuant IQQ is a high-quality quantitation system for making simultaneous accurate biological measurements on several hundred biochemicals in small quantities of biological samples. This is achieved by (1) spiking a complex Internal Standard (WORKFLOW-A) into a biological sample to a) DescriptionTruQuant IQQ is a high-quality quantitation system for making simultaneous accurate biological measurements on several hundred biochemicals in small quantities of biological samples. This is achieved by (1) spiking a complex Internal Standard (WORKFLOW-A) into a biological sample to a) quantify all the biochemicals in the sample relative to their counterparts in the Internal Standard, b) suppression-correct each compound and c) normalize sample to sample variances; and (2) injecting the same well characterized Long-Term Reference Standard (WORKFLOW-B) to create a daily retention time (RT) library of all compounds to be found in the Internal Standard for reproducible ID, and to measure day-to-day (QA/QC) to assure reproducible instrument performance. The system is completely automated using IROA ClusterFinder™software.IROA TruQuant IQQ Workflow Kit contains the materials and tools for the analysis of 90 experimental samples. The kit is intended to be used for mass spectrometry metabolomics applications... Read More | Products contentProducts IntroductionThis product uses the principle that the difference between the concentration of salt ions inside and outside the cell can cause the cell membrane to burst to lyses the cell and releases the genomic DNA, without the need of extracting and purifying the genomic Products contentProducts IntroductionThis product uses the principle that the difference between the concentration of salt ions inside and outside the cell can cause the cell membrane to burst to lyses the cell and releases the genomic DNA, without the need of extracting and purifying the genomic DNA.This product is suitable for a variety of sources of samples, and can be used as a template for PCR and qPCR experiments after sample processing, and can achieve the effect of the purified DNA used as a template for PCR and qPCR experiments. Usage1. Depending on the type of sample, prepare the appropriate sample size according to the table below.2. Add the sample to a 1.5-mi centrifuge tube and add the recommended volume of Solution A as shown in the table below. Vortex for 20 s and allow to stand at room temperature for 3-5 min or incubate in a metal bath at 95°C for 3-5 min as recommended in the table below.3. After the sample has been sufficiently lysed (samples incubated in a metal bath at 95°C should be brought to room temperature), add the recommended volume of Solution B as shown in the table below and vortex for 30s.4. Store processed samples at 4°C if the next test is to be performed within 2 hours, or at -20°C if the next test cannot be performed immediately.take note of1) Depending on the requirements of the experimental conditions, the amount of samples can be expanded or reduced, and the amount of Solution A and Solution B can be increased in equal proportions.2) For blood and cell samples, the temperature of room temperature lysis is required to be around 25C. If the ambient temperature does not reach 25°, the lysis time can be extended appropriately, or the vortex shaking time can be extended to ensure that the samples are fully lysed. If there is no relevant professional instrument, the centrifuge tube can be shaken vigorously to ensure adequate lysis.3) After the tissue sample is made into tissue homogenate by adding 10 times the volume of saline, it can be processed in the same way as blood samples.4) Strictly prohibit the use of expired products, please do not mix different reagents.5) laboratory supplies should be regularly cleaned and 10% of the 84 disinfectant solution or ultraviolet lamp for anti-pollution treatment, special areas dedicated to prohibit cross use, so as to avoid contamination, the end of the test, the bench should be cleaned immediately... Read More |
| Get Quote | Supplier Page | Supplier Page | Supplier Page | Supplier Page | Supplier Page |