| Description | Product introduction:Used to isolate lymphocytes from human organsMatters needing attention:1. samples, reagents and experimental environment in the whole process shall be carried out at 20 ± 2 ℃. In order to obtain the best experimental results, it is best to carry out the Product introduction:Used to isolate lymphocytes from human organsMatters needing attention:1. samples, reagents and experimental environment in the whole process shall be carried out at 20 ± 2 ℃. In order to obtain the best experimental results, it is best to carry out the experiment within 2 h of sampling. The longer the sample is stored, the worse the cell separation effect is. The separation effect is even worse after the sample is placed for more than 6 h, or even cannot achieve the purpose of separation. 2. in this experiment, it is better not to use plastic products with high polymerization materials (such as polystyrene), but use non-static, low static ionization heart tubes and glass products without alkali treatment, because the electrostatic effect will lead to cell adhesion, and the surface of alkali treated glass will become rough, which will affect the effect of cell separation. 3. aspirating too many lymphocyte layers and separation liquid layers will cause the granulocytes at the junction of separation liquid to be aspirated, thus increasing the number of mixed granulocytes. 4. when the amount of separating solution is greater than that of tissue single cell suspension sample, the separation effect is better.Scope of application:Lymphocyte isolation... Read More | Product content: G665990Component200 TStorageG665990ABuffer PG100 mLRTG665990BBuffer PS60 mLRTG665990CBuffer PW (concentrate)50 mLRTG665990DBuffer EB30 mLRTG665990ESpin Columns DM with Collection Tubes200 EART Product Introduction:This kit uses a new silicon-based plasma membrane technology and Product content: G665990Component200 TStorageG665990ABuffer PG100 mLRTG665990BBuffer PS60 mLRTG665990CBuffer PW (concentrate)50 mLRTG665990DBuffer EB30 mLRTG665990ESpin Columns DM with Collection Tubes200 EART Product Introduction:This kit uses a new silicon-based plasma membrane technology and reagent formulation. Through the unique centrifugal adsorption column and the DNA washing elution step, 100 bp-10 kb DNA fragments can be recovered and purified from ordinary or low melting point agarose gel. The sol speed is fast and the recovery rate is high. The sol solution contains a pH indicator, which can be used to determine whether the sol recovery has reached the optimal state based on its color. Each adsorption column can adsorb up to 10 µ G DNA, while effectively removing impurities such as primers, enzymes, mineral oil, and agarose. The purified and recovered DNA has high purity and concentration, good integrity, and can be directly used for molecular biology experiments such as sequencing, linking and transformation, labeling, and in vitro transcription.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.2. Before use, please check the Buffer PG. If crystallization or precipitation occurs, it can be left in a 37 ℃ water bath for 3-5 minutes to restore clarity.3. It is best to use a new electrophoresis buffer during electrophoresis to avoid affecting the electrophoresis and recovery efficiency; The following experiment requires high requirements, please use TAE electrophoresis buffer as much as possible.4.When cutting glue, the UV irradiation time should be as short as possible to avoid damage to DNA.5. The recovery rate is related to the initial amount of DNA and the elution volume. The smaller the initial amount, the smaller the elution volume, and the lower the recovery rate.6. Preheat the water bath to 50 ℃.7. Buffer PG contains a pH indicator. When the pH is ≤ 7.5, the color of the solution is yellow, and DNA can effectively bind to the membrane. When the pH is too high, the color of the solution turns orange red and purple, which needs to be adjusted.8. All centrifugation steps can be performed at room temperature.Operation steps:1. Cut the single purpose DNA strip from the agarose gel (try to cut the excess), put it into a clean centrifuge tube (self prepared), and weigh and calculate the weight of the gel (record the weight of the centrifuge tube in advance).Attention: If the volume of the adhesive block is too large, it can be cut into small pieces.2. Add one time of the volume of Buffer PG (if the gel weighs 100 mg, its volume can be regarded as 100 µ l. And so on.3.50 ℃ water bath and gently invert the centrifuge tube every 2-3 minutes until the sol turns yellow to ensure full dissolution of the gel block. If there are still unsolved glue blocks, you can add some more sol solution or continue to let it stand for a few minutes until the glue blocks are completely dissolved.Note: 1) After the gel is completely dissolved, the gel solution is yellow, and subsequent operations can be carried out; If the glue solution is orange red or purple, 10-30 can be added to the glue solution µ 3 M sodium acetate (pH 5.0), adjust the color of the solution to yellow before proceeding with subsequent operations.2) After the gel block is completely dissolved, it is best to lower the temperature of the gel solution to room temperature before loading the column. The adsorption column has a weaker ability to bind DNA at higher temperatures.4. (Optional step) When the recovered fragment is less than 300 bp, add 1/2 of the gel volume of isopropanol, and mix it upside down (if the gel weighs 100 mg, add 50 µ Isopropanol of L.5. Column balance: Add 200 to the spin columns DM that have been loaded into the collection tube µ Centrifuge at 13000 rpm (~16200 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.6. Add the solution obtained from steps 3 or 4 to the adsorption column that has been loaded into the collection tube, let it stand at room temperature for 2 minutes, centrifuge at 13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.Attention: The volume of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ L can be added in batches.7. Add 450 to the adsorption column µ LBuffer PW (please check if anhydrous ethanol has been added before use), centrifuge at 13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.Note: If purified DNA is used for salt sensitive experiments (such as flat end ligation or direct sequencing), it is recommended to add Buffer PW and let it stand for 2-5 minutes before centrifugation.8. Repeat step 7.9.13000 rpm for 1 minute and discard the waste liquid from the collection tube.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).10. Place the adsorption column into a new 1.5 ml centrifuge tube (provided by oneself), and add 50 drops to the middle position of the adsorption membrane in the air µ L Buffer EB, leave at room temperature for 2 minutes. Centrifuge at 13000 rpm for 1 minute and collect DNA solution- Store DNA at 20 ℃.Attention:1) To improve the recovery of DNA, the solution obtained by centrifugation can be re dropped onto the adsorption column, left at room temperature for 2 minutes, and centrifuged at 13000 rpm for 1 minute.2) The elution volume should not be less than 30 µ l. A small volume will affect the recovery efficiency.3) When recovering DNA fragments larger than 10 kb, Buffer EB should be preheated in a 50 ℃ water bath to increase recovery efficiency.Note: This reagent kit is also suitable for the purification and recovery of PCR products. Add an equal volume of Buffer PG to the PCR reaction solution and mix thoroughly (for small fragments with a recovery of less than 150bp, the solution volume can be increased to three times to improve the recovery rate). Follow step 5 above for further operations... Read More | Product content: Component G665666 200 preps Buffer P1 60ml Buffer P2 60ml Buffer E3 60ml Buffer PW (concentrate) 25ml Buffer EB 30ml RNase A (10 mg/ml) 600 µl Spin Columns DM 200 with Collection Tubes 200Product Introduction:This reagent kit is suitable for extracting 1-5 ml of Product content: Component G665666 200 preps Buffer P1 60ml Buffer P2 60ml Buffer E3 60ml Buffer PW (concentrate) 25ml Buffer EB 30ml RNase A (10 mg/ml) 600 µl Spin Columns DM 200 with Collection Tubes 200Product Introduction:This reagent kit is suitable for extracting 1-5 ml of bacterial solution. On the basis of alkaline lysis of cells, it efficiently and specifically binds plasmid DNA through a new silicon-based membrane. Each adsorption column can adsorb up to 40% µ The plasmid DNA of g is effectively removed with a special buffer system to effectively remove impurities such as proteins. The yield and purity of plasmids obtained from this kit are high, and the quality is stable. It is suitable for downstream experiments such as cell transfection, DNA sequencing, PCR, PCR based mutations, in vitro transcription, transformed bacteria, and endonuclease digestion.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1. All components can be stably stored for 1 year in a dry, room temperature (15-30 ℃) environment. The adsorption column can be stored for a longer time at 2-8 ℃. 2.Buffer P1 with RNase A added can be stably stored for 6 months at 2-8 ℃. Before use, add RNase A to Buffer P1 (add all RNase A provided in the reagent kit), mix well, and store at 2-8 ℃. Before use, it is necessary to leave it at room temperature for a period of time, and then use it after returning to room temperature.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer P2 and Buffer E3. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. Note that Buffer P2 and Buffer E3 contain irritating substances. Please wear gloves when operating and immediately cover the lid after use.6.The amount and purity of plasmid extraction are related to factors such as bacterial culture concentration, strain type, plasmid size, and plasmid copy number.7. The maximum volume of Spin Columns DM is 750 µ l. If the sample volume is greater than 750 µ L can be added in batches.Operation steps:1. Take 1-5 ml of overnight cultured bacterial solution and add it to a centrifuge tube (provided). Centrifuge at 13000 rpm (~16200 × g) for 1 minute to collect bacteria, and try to discard all the supernatant as much as possible.2. Add 200 to the centrifuge tube containing bacterial sediment µ Buffer P1 (please check if RNase A has been added first), mix thoroughly with a pipette or vortex oscillator, and suspend bacterial precipitation.Attention: If the bacterial blocks are not thoroughly mixed, it will affect the cracking effect, resulting in low extraction amount and purity.3. Add 200 to the centrifuge tube µ Buffer P2, gently invert and mix 8-10 times to fully lyse the bacterial cells. At this point, the solution should become clear and viscous.Attention: Mix gently and do not shake vigorously to avoid interrupting genomic DNA and mixing genomic DNA fragments in the extracted plasmid. If the solution does not become clear, it indicates that the bacterial count may be too large and the lysis may not be complete. The bacterial count should be reduced or the dosage of P1, P2, E3, and isopropanol should be increased proportionally.4. Add 200 to the centrifuge tube µ Buffer E3, immediately invert and mix 8-10 times, at which point white flocculent precipitates appear. Centrifuge at 13000 rpm for 5 minutes.Attention: After adding Buffer E3, it should be mixed evenly immediately to avoid local precipitation.5. Add 260 to the spin columns DM that have been loaded into the collection tube µ After adding isopropanol, immediately add the supernatant collected in step 4 and mix it upside down.Attention: After adding isopropanol, immediately add the supernatant and mix well to avoid isopropanol dripping into the collection tube after being left for a long time. The maximum volume of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ l. Isopropanol and the supernatant can be collected in a centrifuge tube (provided by oneself), mixed well, and passed through the column in batches.6.13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 400 to the adsorption column µ L Buffer PW (please check if anhydrous ethanol has been added first), centrifuge at 13000 rpm for 1 minute, and discard the waste liquid in the collection tube.8. Place the adsorption column in a new collection tube and add 50-100 to the middle of the adsorption membrane µ Centrifuge at 13000 rpm for 1 minute using buffer EB and collect the plasmid solution into a centrifuge tube- Store the plasmid at 20 ℃.Note: 1) To increase the efficiency of plasmid recovery, the obtained solution can be added back to the adsorption column, left at room temperature for 2-5 minutes, centrifuged at 13000 rpm for 2 minutes, and collected into a centrifuge tube.2) When the plasmid copy number is low or>10 kb, preheating the buffer EB in a water bath at 65-70 ℃ can increase the extraction efficiency... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Product contentU665751Component100 TStorageU665751A2×UltraSYBR One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751BUltraSYBR One Step EnzymeMix50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751C50×High ROX50 µL-20℃. AvoidProduct contentU665751Component100 TStorageU665751A2×UltraSYBR One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751BUltraSYBR One Step EnzymeMix50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751C50×High ROX50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751DRNase-Free Water1.5 mL-20℃. Avoid freeze/ Thaw cycle. Product Introduction This product is a specialized kit for one-step Real-Time RT-qPCR. The SYBR Green I fluorescent dye contained can bind to all double-stranded DNA, allowing this product to be used for the detection of many different target sequences without the need to synthesize specific labeling probes. Real Time RT-qPCR reaction using this product, reverse transcription and quantitative PCR are carried out in the same reaction system, there is no need to add reagents during the reaction, no need to open the cap of the tube, avoiding contamination while improving the efficiency of the experiment. The new high-efficiency reverse transcriptase RNase H is activity-deficient, which reduces the degradation of RNA in the reverse transcription reaction. The enzyme has high reverse transcription efficiency and can perform a good reverse transcription reaction on a small amount of RNA template. It has high affinity to RNA and can read through RNA templates with high GC content and complex secondary structure. New efficient hot start enzyme, the enzyme activity is closed at room temperature, thus effectively avoiding non-specific amplification caused by non-specific binding of primers and templates or primer dimerization at room temperature, which greatly improves the accuracy of fluorescence quantitative PCR reaction. The included buffer system maximizes the efficacy of both enzymes at the same time and improves efficiency. This product has high sensitivity, high specificity, wide linear range, and more accurate quantification of target genes.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used with Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument. Instruments that do not require ROX calibration (U665567) Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others. Instruments that require High ROX calibration (U665751) ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1. Before using the reagents in this kit, please mix them gently by turning them up and down to avoid foaming as much as possible, and use them after brief centrifugation.2. This product uses RNA as the template for one-step RT-PCR experiment, RNase contamination should be avoided during operation, it is recommended to operate RNA in a special area, use special instruments and consumables, the operator with a mask and disposable gloves and often change the gloves, the experiment-related consumables should be processed with 0.1% DEPC (diethyl ether of pyrocarbonate) aqueous solution at 37℃ for 12 hours and autoclaved for 30 minutes before use. Sterilize for 30 minutes before use.3. UltraSYBR One Step RT-qPCR Buffer contains SYBR Green I fluorescent dye. Avoid bright light when storing this product or preparing PCR reaction solutions.4. Repeated freezing and thawing of each reagent in this kit should be avoided; repeated freezing and thawing may degrade the product performance. This product can be stored for a long time at -20℃, protected from light. If frequent use is required in the short term, it can be stored at 2-8℃.5. This kit must use specific primers, the choice of primers can be selected according to specific experiments, the good or bad primer design directly affects the results of RT-PCR reaction, the design of primers need to consider the GC content, primer length, primer position, the secondary structure of the PCR product and other factors, it is recommended to use a professional primer design software for design.6. This product cannot be used for fluorescent quantitative PCR by the probe method.Usage1. Dissolve RNA template, primers, 2× UltraSYBR One Step Buffer, UltraSYBR One Step EnzymeMix and RNase-Free Water and set aside on ice.2. PCR reaction system:Reagents25 µl Reaction systemFinal concentration2×UltraSYBR One Step Buffer12.5 µl1×Forward Primer,10 µM0.5 µl0.2 µM¹⁾Reverse Primer,10 µM0.5 µl0.2 µM¹⁾UltraSYBR One Step EnzymeMix0.5 µl RNA TemplateX µl10 pg – 100 ng50×Low ROX or High ROX(optional)2)0.5 µl1×RNase-Free Waterup to 25 µlNote: 1) Usually, the primer concentration of 0.2µM can get better results, and the final concentration of 0.1-0.5µM can be used as a reference for setting the range. If the amplification efficiency is not high, the concentration of primer can be increased; when non-specific reaction occurs, the concentration of primer can be decreased, thus optimizing the reaction system.(2) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.3. Vortex and shake to mix, centrifuge briefly, and collect the solution at the bottom of the tube.4. RT-qPCR reaction conditions (fluorescence quantitative PCR is a two-step method), this program is based on the ABI 7500 fluorescence quantitative PCR instrument as an exampleNote: 1) It is recommended to use two-step PCR reaction program, if you improve the reaction specificity, you can increase the annealing temperature to 60-64 ℃ as a reference for the setting range; if you do not get good experimental results due to the use of primers with lower Tm values, etc., you can try to carry out three-step PCR amplification.(2) For melting curve analysis, please set up the program recommended by the fluorescence quantitative PCR instrument used, and this program is set up with the ABI 7500 fluorescence quantitative PCR instrument as a reference.RT-qPCR reaction conditions (fluorescence quantitative PCR was a three-step method):Note: 1) For three-step PCR amplification, please use the range of 56℃-64℃ as the setting reference for the annealing temperature.(2) For melting curve analysis, please set up the program recommended by the fluorescence quantitative PCR instrument you are using, this program is ABI750 fluorescent quantitative PCR instrument as a reference setting... Read More |