| Description | Inquire | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | functional group:carboxylic acid Description:Liposome Kit has been used for the preparation of liposomes. Composition:Cholesterol, 9 µmol/package L-α-Phosphatidylcholine (egg yolk), 63 µmol/package Stearylamine, 18 µmol/package | Live & deadtm animal cell viability / toxicity detection kit (calcein am, ethd-i) is a kit that provides double fluorescent staining for the detection of animal cell death and survival. The two probes in the kit can respectively measure the activity of cellular lactonase and the integrity of Live & deadtm animal cell viability / toxicity detection kit (calcein am, ethd-i) is a kit that provides double fluorescent staining for the detection of animal cell death and survival. The two probes in the kit can respectively measure the activity of cellular lactonase and the integrity of plasma membrane to reflect cell viability. The kit can be used for fluorescence microscopy, flow cytometry, microplate reader and other fluorescence detection systems. This kit can be applied to most eukarYOtic mammalian cells, including some tissues with adherent nuclei, but it is not applicable to fungi and yeast. Compared with trypan blue, the kit is faster, safer and more sensitive.Component: Product parameters:Calcein am: ex/em = 494 / 517 nm; Ethd-i: ex/em = 528 / 617 nm (bound DNA)Usage:Fluorescence microscopy detection1. Prepare working fluidPreparation 2 µ M Calcein AM and 4 µ M EthD-I staining solution: Remove the original solution of Calcein AM and EthD-I and restore them to room temperature. Add 20 µ L 2 mM EthD-I and 5 µ Mix 4 mM Calcein AM with 10 mL PBS or other serum-free buffer or culture medium, vortex well. The above working solution can be directly used for cell staining.Note: The aqueous solution of Calcein AM is easily hydrolyzed and should be used up every day. The concentration selection of Calcein AM and EthD-I varies depending on the type of cell used, with a recommended concentration range of 0.1-10 µ M.2. Prepare cells and conduct experiments(1) For adherent cells, they can be washed 2-3 times with 1 × PBS before staining. For suspended cells, centrifuge at room temperature of 250-1000 × g for 5 minutes and collect cells for staining.(2) Wash the cells thoroughly 2-3 times with 1 × PBS to remove residual esterase activity.(3) For adherent cells, add sufficient amount of Calcein AM/EthD-I staining solution. For suspended cells, add an appropriate amount of staining solution to control the cell density between 1-5 × 105/mL.(4) Incubate at room temperature in dark for 15-20 minutes (if the working solution concentration is high or the incubation temperature is high, the incubation time should be appropriately reduced).(5) Observe the labeled cells under a fluorescence microscope.Flow cytometry detection1. Remove the reagent and restore it to room temperature.2. Preparation 2 µ M Calcein AM and 4 µ M EthD-I staining solution: Take out the original solution of Calcein AM and EthD-I, and restore to room temperature. Add 20 µ L 2 mMEthD-I and 5 µ Vortex mix 4 mM Calcein AM with 10 mL PBS or other serum-free buffer or culture medium. The working fluid can directly stain cells.3. Wash cells thoroughly 2-3 times with 1 × PBS.4. Suspend cells with 0.5 mL of staining solution and control the cell density to 1-5 × 105/mL.Note: It is recommended to prepare two additional cell samples, each containing only one dye (Calcein AM and EthD-I), for compensatory regulation of flow cytometry single staining; Prepare another cell sample containing only buffer solution (which should be consistent with the buffer used to prepare Calcein AM and EthD-I detection working solutions) as a negative control for flow cytometry analysis.5. Incubate at room temperature in dark for 15-20 minutes.6. Within 1-2 hours, cell activity was detected by flow cytometry. Calcein AM can be excited by a 488 nm laser, with fluorescence emission spectra detected at around 530 nm and EthD-I emission spectra at around 610 nm.Note: When using the cell circle gate, attention should be paid to excluding cell debris and using a single staining tube to regulate compensation. Double staining tube flow cytometry should obtain two relatively independent cell populations: a live cell population displaying green fluorescence and a dead cell population displaying red fluorescence.ELISA reader detection1. Cultivate an appropriate amount of adherent or suspended cells in a 96 well black ELISA plate.Note: Dead cells can be obtained by treating cells with 1% saponin or 0.1-0.5% digitalis saponin for 10 minutes.2. Preparation 2 µ M Calcein AM and 4 µ M EthD-I staining solution:Remove the original solutions of Calcein AM and EthD-I and restore them to room temperature. Add 20 µ L 2 mM EthD-I and 5 µ Mix 4 mM Calcein AM 10 mL PBS or other serum-free buffer or culture medium, vortex well.Note: (1) 10 mL of staining solution is sufficient to stain a 96 well plate, and the volume of the staining solution can be adjusted according to experimental needs. The concentrations of Calcein AM and EthD-I can range from 0.1 to 10 µ Explore between M.(2) The aqueous solution of Calcein AM is easily hydrolyzed and should be used up every day. EthD-I working solution can be stored at -20 ℃ for at least one year.3. Wash the cells thoroughly with 1 × PBS to remove residual esterase activity. For adherent cells, add 100 to each well µ Wash cells with PBS. For suspended cells, add 100 µ Resuspend cells with L PBS and centrifuge to remove the supernatant. Repeat the above operation.4. Add 100 to each hole µ L PBS.5. Add 100 to each hole µ L staining solution, making the total volume of each well 200 µ L. The final concentration of Calcein AM is 1 µ M. The final concentration of EthD-I is 2 µ M. Gently shake the culture plate to evenly cover the cells with the liquid.Incubate at room temperature in dark for 30-45 minutes.Note: The optimal incubation time varies for different cells, with 30 minutes as the initial incubation time. Subsequently, the staining time can be adjusted and optimized according to the actual staining effect to obtain a more ideal staining effect.7. Enzyme reader detection. When the ELISA reader is set to fluorescein, it can detect Calcein AM; When the ELISA reader is set to rhodamine or Texas Red, EthD-I can be detected. Select the optimal emission and excitation wavelengths based on spectral characteristics.Note: By comparing the relative fluorescence values (RFU) measured between the sample group and the control group, the changes in the number of dead and live cells can be obtained. Another method of data analysis is also provided below.The following method can calculate the ratio of live cells to dead cells in a certain region. The required samples include dead cell control group, live cell control group, and the sample group to be tested. Dead cells can be obtained by treating cells with 1% saponin or 0.1-0.5% digitalis saponin for 10 minutes.1. Prepare staining solution and follow the above steps to stain cells. Additionally, prepare 1 mL and 2 mL separately µ M Calcein AM and 4 µ M EthD-I solution, stain the control group according to the following instructions. For the following groups of cells or cell-free groups, it is necessary to maintain complete consistency in cell count, detection of working solution concentration, incubation time, and incubation temperature.2. Measurement of sample group and control group:A. The measured values of the sample group at 645 nm are denoted as Calcein AM and EthD-I=F (645) sam.B. The measured values of the sample group at 530 nm are denoted as Calcein AM and EthD-I=F (530) sam.C. The measurement value of dead cell EthD-I single staining control group at 645 nm is denoted as EthD-I=F (645) maxD. The measurement value of dead cell Calcein AM single staining control group at 645 nm is recorded as Calcein AM=F (645) minE. The measurement value of live cell EthD-I single staining control group at 530 nm is recorded as EthD-I=F (530) min.F. The measurement value of live cell Calcein AM single staining control group at 530 nm is denoted as Calcein AM=F (530) max.G. A blank control well without cells (with or without dye), the detection value at 530 nm is recorded as F (530) 0.H. A blank control well without cells (with or without dye), the detection value at 645 nm is recorded as F (645) 0.3. Calculate the ratio of dead cells to live cells based on measurement data:%Live Cells=(B-E) ÷ (F-E)%Dead Cells=(A-D) ÷ (C-D)Determine the ratio of live cells to dead cells in a certain areaBy creating fluorescence spectral standard curves at 530 nm and 645 nm, the number of dead and live cells can be determined, and the fluorescence intensity of each dye is linearly related to the number of dead or live cells in the sample.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. phenol red or serum may interfere with the detection of this kit. 3. fluorescent dyes have quenching problems. Please try to avoid light during experimental operation to slow down fluorescence quenching. 4. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Dead and live cell staining (animal)... Read More | Products contentN665730Component24 T96 TStorageN665730ATPS V50 144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730B5×FA Reaction Buffer144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730C2×HiFidelity PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw Products contentN665730Component24 T96 TStorageN665730ATPS V50 144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730B5×FA Reaction Buffer144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730C2×HiFidelity PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw cycle.N665730DPPM48 µL192 µL-20℃. Avoid freeze/thaw cycle.* This kit is suitable for human genomic DNA library construction with a starting template DNA input of 50 ng. We also have transposase library construction kits for human genomic DNA starting at 5 ng and 1 ng, so it is recommended to use different kits for different starting amounts of DNA in order to obtain higher quality libraries. Products IntroductionThis kit is developed for Illumina's high-throughput sequencing platform and provides the enzyme premix system and reaction buffer for genomic DNA library construction, including all components except PCR primers. Compared with the traditional library construction kits, this kit adopts the new transposase method for library construction, which can complete DNA fragmentation, end repair and junction reaction in one simple enzymatic reaction, significantly reducing the amount of template, reducing the number of experimental steps, and shortening the time of library construction; it adopts the high-fidelity DNA polymerase for library enrichment, and the preference-free PCR amplification can expand the coverage area of the sequence, which can be used for efficient and effective sequencing. The use of high-fidelity DNA polymerase for library enrichment and preference-free PCR amplification broadens the coverage area of the sequence and enables efficient preparation of DNA libraries for Illumina's second-generation sequencing platform. The kit is suitable for DNA libraries with a starting template of 50 ng, and all reagents in the kit have been subjected to strict quality control and functional validation to maximize the stability and reproducibility of library construction. Product Features ● DNA fragmentation and junction ligation in one step.● Ultra-fidelity amplification minimizes amplification-preferred steps.Provide your own instruments, kits and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use DNA purification and recovery kit by magnetic bead method.3. Library PCR primer kits: transposase method for second-generation sequencing multi-sample primer kits are recommended. 4. Anhydrous ethanol, deionized water (pH between 7.0 and 8.0).5. Reaction tubes: It is recommended to use low adsorption PCR tubes and 1.5 ml centrifuge tubes. Tips: It is recommended to use high quality filter tips to prevent contamination of kits and library samples. Pre-experiment Preparation and Important Notes1. Avoid repeated freezing and thawing of reagents.2. PCR products are easily contaminated due to improper operation, resulting in inaccurate results. It is recommended to isolate the PCR reaction system preparation area from the PCR product purification area, and to use special pipettes to clean the experimental areas at regular intervals.3. Bead purification: the beads should be equilibrated to room temperature before use, all operations on the beads should be carried out at room temperature, 80% ethanol should be dispensed freshly, the beads should be rinsed and dried until the surface is free of liquid reflections and has a frosted appearance, insufficient drying of the beads will cause ethanol residue that will affect the subsequent experiments, and over-drying of the beads will affect the efficiency of DNA recovery.4. The kit is suitable for human genomic DNA library construction, if the DNA sample is a PCR product, it should be ensured that its length>.500 bp, since transposases do not work on DNA ends, it is recommended to extend the PCR product by 50-100 bp at each end of the PCR product to avoid low coverage of the ends for sequencing.Sample PreparationDNA purity requirements: A260/A280 = 1.8-2.0. Sample DNA: dissolve in ultrapure water. DNA Quantification: Too much or too little DNA will affect the quality of the library. It is recommended to use Nano to test the purity of the genomic DNA and then use Qubit to test the concentration of the genome (do not use any absorbance-based assay for template quantification).Schematic diagram of DNA banking processprocedureDNA fragmentation, junction reaction1. Add the following reagents to a 200 µl PCR tube: 2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:DNA should be purified immediately after the fragmentation reaction has been performed and the transposase is still in a high state of activity.to prevent smaller library fragments due to DNA over-fragmentation. Purification of fragmentation productsWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Add 50 µl of magnetic beads equilibrated to room temperature to the fragmentation product, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, then add 23 µlddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer 21 µl of supernatant to a new 200 µl PCR tube.PCR amplification Add the following reagents to the 200 µl PCR tube: Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:Selective recovery of library DNA fragmentsIt is recommended to use CombiVision Magnetic Beads DNA Purification and Recovery Kit for selective recovery of DNA fragments. When different sizes of DNA fragments are required, the amount of magnetic beads to be used is different, please refer to the attached table for the specific amount of magnetic beads to be used (if other brands of magnetic beads are used, you need to find out the optimal amount of magnetic beads to be used on your own).Note: Amplification products can also be fragment length sorted and purified using the Gum Recovery Kit. If there is no special requirement for library length distribution, the amplification products can also be purified without selective recovery of DNA fragments as described on page 6 of the manual.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Transfer the PCR product to a 1.5 ml centrifuge tube, rehydrate to 100 µl and add several volumes of magnetic beads equilibrated to room temperature, vortex for 5 seconds and let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, and carefully aspirate the supernatant and transfer it to a new 1.5 ml centrifuge tube.Note: Do not discard the top clear.4. Add several volumes of magnetic beads to the supernatant, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.5. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA.Note: Do not discard the beads.6. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.7. Repeat step 6 once.8. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 20 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.9. Remove the centrifuge tube from the magnetic rack, vortex and oscillate to completely resuspend the beads, and let stand at room temperature for 5 minutes. Leave brieflycentrifuge, place the tube on a magnetic rack until the solution is clear, and transfer the supernatant solution to a new centrifuge tube. Table: Suggested amount of magnetic beads for different segment selection recoveryLibrary DNA fragment purificationWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. 50 µl of magnetic beads equilibrated to room temperature were added to the PCR product, vortexed and shaken for 5 seconds, and then left to stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 25 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new tube.Library quality controlDetermination of library concentrationIn order to obtain high-quality sequencing results, accurate quantification of DNA libraries is required, and the first recommendation is to use Real-timePCR methods are used for absolute quantification of DNA libraries. Additionally, fluorescent dye methods such as the Qubit method or the fluorescent dye picogreen method can be used; do not use quantification methods based on absorbance measurements here. The following approximate formula can be used to convert the molar concentration of the DNA library. Average total length of librariesApproximate conversion formula Library fragment distributionThe prepared DNA libraries can be detected by agarose gel electrophoresis or Agilent 2100 Bioanalyzer.Range of segment length distributions... Read More |