| Description | Inquire | The miRNA extraction kit is specifically designed to isolate and purify miRNAs from various animal tissues, plant tissues, cells, serum, plasma and other samples. It can also extract small molecule RNAs such as siRNA and snRNA that are less than 200 nt, and can also be used for the extraction of The miRNA extraction kit is specifically designed to isolate and purify miRNAs from various animal tissues, plant tissues, cells, serum, plasma and other samples. It can also extract small molecule RNAs such as siRNA and snRNA that are less than 200 nt, and can also be used for the extraction of total RNA. This product combines phenol/guanidine lysis technology and silicon matrix membrane purification technology. The unique lysis solution can effectively inhibit RNases while removing most of DNA and proteins from cell or tissue samples through organic extraction. For some sensitive downstream experiments, if miRNA enrichment is required, this kit can be used to enrich miRNA separately. This product is suitable for a wide range of samples, with high purity of prepared RNA, and can be directly used for sensitive downstream applications, such as Northern Blot analysis, Real Time PCR, Microarray Analysis, etc. M665531Component50 TStorageM665531ATRIzon Reagent60 mL2-8℃. Protect from ligt.M665531BBuffer RWT (concentrate)15 mLRTM665531CBuffer RW2 (concentrate)11 mLRTM665531DRNase-Free Water10 mLRTM665531ESpin Columns RM with Collection Tubes50 setsRTM665531FSpin Columns RS with Collection Tubes50 setsRTM665531GRNase-Free Centrifuge Tubes (1.5 mL)50 EART Self prepared reagents: chloroform, anhydrous ethanol (newly opened or dedicated for RNA extraction).Preparation and important precautions before the experiment:To prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The extracted samples should avoid repeated freeze-thaw cycles, otherwise it will affect the quantity and quality of miRNA extraction.Before the first use, anhydrous ethanol should be added to Buffer RWT and Buffer RW2 according to the instructions on the reagent bottle label.4. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Operation steps:Protocol A: miRNA enrichment (can be directly used for sensitive downstream experiments)1. Sample processing1a Organization: Grind the organization in liquid nitrogen. Add 1 ml of TRIzon Reagent to every 30-50 mg of tissue, shake and mix well. The sample volume shall not exceed one tenth of the volume of TRIzon Reagent.1b Single layer culture of cells: Remove the culture medium, add TRIzon Reagent, and add 1 ml of TRIzon Reagent every 10 cm2 (the amount of lysis solution depends on the area of the culture bottle).1c Cell suspension: Centrifuge to obtain cell precipitate, discard supernatant. Add 1 ml of TRIzon Reagent to every 5 x 106-1 x 107 cells (cells do not require washing).1d Plasma or serum: Take 200 µ Add 5 times the volume of TRIzon Reagent to plasma or serum samples, shake and mix well for 30 seconds.2. After adding TRIzon Reagent to the sample, blow it repeatedly several times to fully crack it. Leave at room temperature for 5 minutes to completely separate the protein nucleic acid complex.3. Optional steps: Centrifuge at 4 ℃ 12000 rpm (~13400 × g) for 5 minutes, take the supernatant, and transfer it to a new centrifuge tube (provided by oneself) (if the sample contains more proteins, fats, polysaccharides, etc., this step can be performed).4. Add chloroform to the supernatant and add 200 to every 1 ml of TRIzon Reagent used µ Chloroform, cover the tube, vigorously shake for 15 seconds, and let it sit at room temperature for 5 minutes.Centrifuge at 5.4 ℃ and 12000 rpm for 15 minutes. The sample is divided into three layers: red organic phase, middle layer, and colorless aqueous phase. Transfer the upper colorless aqueous phase to a new centrifuge tube (self prepared).6. Add 1/3 volume of anhydrous ethanol to the solution obtained in step 5, mix well, and transfer the obtained solution and precipitate together into the adsorption column RM (Spin Columns RM) that has been loaded into the collection tube. If you cannot add all the solution to the adsorption column at once, please transfer it multiple times. Centrifuge at 12000 rpm for 30 seconds, discard the adsorption column RM after centrifugation, and retain the effluent.7. Add 2/3 times the volume of anhydrous ethanol to the solution obtained in step 6 and mix well.8. Transfer the solution and precipitate obtained from the previous step into the adsorption column RS (Spin Columns RS) that has been loaded into the collection tube. If you cannot add all the solution to the adsorption column at once, please transfer it multiple times. Centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RS back into the collection tube.9. Add 700 to the adsorption column RS µ L Buffer RWT (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RS back into the collection tube.10. Add 500 to the adsorption column RS µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RS back into the collection tube.11. Repeat step 10.12. Centrifuge at 12000 rpm for 1 minute and discard the waste liquid from the collection tube. Place the adsorption column RS at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column RS, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).13. Place the adsorption column RS in a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store the obtained RNA solution at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 13 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column RS and repeat step 13Protocol B: Extraction of total RNA (including miRNA and other small molecule RNAs<200 nt), steps 1-5 are the same as protocol A.6. Add 1.25 times the volume of anhydrous ethanol to the solution obtained in step 5 and mix well.7. Transfer the solution and precipitate obtained from the previous step into the spin columns RM that have been loaded into the collection tube. If you cannot add all the solution to the adsorption column RM at once, please transfer it multiple times. Centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM back into the collection tube.8. Add 700 to the adsorption column RM µ L Buffer RWT (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM back into the collection tube.9. Add 500 to the adsorption column RM µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM back into the collection tube.10. Repeat step 9.11. Centrifuge at 12000 rpm for 1 minute and discard the waste liquid from the collection tube. Place the adsorption column RM at room temperature for a few minutes to thoroughly air dry. Attention: The purpose of this step is to remove residual ethanol from the adsorption column RM, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).12. Transfer the adsorption column RM into a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store the obtained RNA solution at -70 ℃ to prevent degradation. Attention: 1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 12 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column RM and repeat step 12... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Product contentU665751Component100 TStorageU665751A2×UltraSYBR One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751BUltraSYBR One Step EnzymeMix50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751C50×High ROX50 µL-20℃. AvoidProduct contentU665751Component100 TStorageU665751A2×UltraSYBR One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751BUltraSYBR One Step EnzymeMix50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751C50×High ROX50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751DRNase-Free Water1.5 mL-20℃. Avoid freeze/ Thaw cycle. Product Introduction This product is a specialized kit for one-step Real-Time RT-qPCR. The SYBR Green I fluorescent dye contained can bind to all double-stranded DNA, allowing this product to be used for the detection of many different target sequences without the need to synthesize specific labeling probes. Real Time RT-qPCR reaction using this product, reverse transcription and quantitative PCR are carried out in the same reaction system, there is no need to add reagents during the reaction, no need to open the cap of the tube, avoiding contamination while improving the efficiency of the experiment. The new high-efficiency reverse transcriptase RNase H is activity-deficient, which reduces the degradation of RNA in the reverse transcription reaction. The enzyme has high reverse transcription efficiency and can perform a good reverse transcription reaction on a small amount of RNA template. It has high affinity to RNA and can read through RNA templates with high GC content and complex secondary structure. New efficient hot start enzyme, the enzyme activity is closed at room temperature, thus effectively avoiding non-specific amplification caused by non-specific binding of primers and templates or primer dimerization at room temperature, which greatly improves the accuracy of fluorescence quantitative PCR reaction. The included buffer system maximizes the efficacy of both enzymes at the same time and improves efficiency. This product has high sensitivity, high specificity, wide linear range, and more accurate quantification of target genes.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used with Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument. Instruments that do not require ROX calibration (U665567) Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others. Instruments that require High ROX calibration (U665751) ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1. Before using the reagents in this kit, please mix them gently by turning them up and down to avoid foaming as much as possible, and use them after brief centrifugation.2. This product uses RNA as the template for one-step RT-PCR experiment, RNase contamination should be avoided during operation, it is recommended to operate RNA in a special area, use special instruments and consumables, the operator with a mask and disposable gloves and often change the gloves, the experiment-related consumables should be processed with 0.1% DEPC (diethyl ether of pyrocarbonate) aqueous solution at 37℃ for 12 hours and autoclaved for 30 minutes before use. Sterilize for 30 minutes before use.3. UltraSYBR One Step RT-qPCR Buffer contains SYBR Green I fluorescent dye. Avoid bright light when storing this product or preparing PCR reaction solutions.4. Repeated freezing and thawing of each reagent in this kit should be avoided; repeated freezing and thawing may degrade the product performance. This product can be stored for a long time at -20℃, protected from light. If frequent use is required in the short term, it can be stored at 2-8℃.5. This kit must use specific primers, the choice of primers can be selected according to specific experiments, the good or bad primer design directly affects the results of RT-PCR reaction, the design of primers need to consider the GC content, primer length, primer position, the secondary structure of the PCR product and other factors, it is recommended to use a professional primer design software for design.6. This product cannot be used for fluorescent quantitative PCR by the probe method.Usage1. Dissolve RNA template, primers, 2× UltraSYBR One Step Buffer, UltraSYBR One Step EnzymeMix and RNase-Free Water and set aside on ice.2. PCR reaction system:Reagents25 µl Reaction systemFinal concentration2×UltraSYBR One Step Buffer12.5 µl1×Forward Primer,10 µM0.5 µl0.2 µM¹⁾Reverse Primer,10 µM0.5 µl0.2 µM¹⁾UltraSYBR One Step EnzymeMix0.5 µl RNA TemplateX µl10 pg – 100 ng50×Low ROX or High ROX(optional)2)0.5 µl1×RNase-Free Waterup to 25 µlNote: 1) Usually, the primer concentration of 0.2µM can get better results, and the final concentration of 0.1-0.5µM can be used as a reference for setting the range. If the amplification efficiency is not high, the concentration of primer can be increased; when non-specific reaction occurs, the concentration of primer can be decreased, thus optimizing the reaction system.(2) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.3. Vortex and shake to mix, centrifuge briefly, and collect the solution at the bottom of the tube.4. RT-qPCR reaction conditions (fluorescence quantitative PCR is a two-step method), this program is based on the ABI 7500 fluorescence quantitative PCR instrument as an exampleNote: 1) It is recommended to use two-step PCR reaction program, if you improve the reaction specificity, you can increase the annealing temperature to 60-64 ℃ as a reference for the setting range; if you do not get good experimental results due to the use of primers with lower Tm values, etc., you can try to carry out three-step PCR amplification.(2) For melting curve analysis, please set up the program recommended by the fluorescence quantitative PCR instrument used, and this program is set up with the ABI 7500 fluorescence quantitative PCR instrument as a reference.RT-qPCR reaction conditions (fluorescence quantitative PCR was a three-step method):Note: 1) For three-step PCR amplification, please use the range of 56℃-64℃ as the setting reference for the annealing temperature.(2) For melting curve analysis, please set up the program recommended by the fluorescence quantitative PCR instrument you are using, this program is ABI750 fluorescent quantitative PCR instrument as a reference setting... Read More | Inquire |