| Description | Inquire | Annexin V ( annexin-V ) is a Ca2 + dependent phospholipid binding protein with a molecular weight of 35-36 KD, which can selectively bind to phosphatidylserine ( PS ). Phosphatidylserine ( PS ) is mainly distributed in the inner side of the cell membrane, that is, the side adjacent to the cytoplasm.Annexin V ( annexin-V ) is a Ca2 + dependent phospholipid binding protein with a molecular weight of 35-36 KD, which can selectively bind to phosphatidylserine ( PS ). Phosphatidylserine ( PS ) is mainly distributed in the inner side of the cell membrane, that is, the side adjacent to the cytoplasm. In the early stage of apoptosis, different types of cells will turn phosphatidylserine out to the cell surface and expose to the extracellular environment. At this time, using Annexin V labeled with fluorescent protein PE, that is, Annexin V-PE, combined with phosphatidylserine ( PS ), the eversion of phosphatidylserine, an important feature of apoptosis, can be directly detected by flow cytometry. Normal cells will not be stained by Annexin V-PE, apoptotic or necrotic cells will be stained by Annexin V-PE. Annexin V-PE can be used in combination with partially non-permeable nuclear dye ( 7-AAD / PI ) to distinguish cells at different stages of apoptosis. RedNucleus II provided in this kit is a far-red dye that belongs to an anthraquinone compound and cannot penetrate the intact cell membrane of living cells and early apoptotic cells. It is non-permeable, but can quickly stain the nucleus / dsDNA in dead and permeable cells. RedNucleus II is an ideal substitute for propidium iodide ( PI ) and 7-AAD.Combined with Annexin V-PE, it has better spectral characteristics without compensation regulation : it is not excited by ultraviolet light and does not overlap with PE / PE homologues, so it can be combined with FITC, PE and purple fluorescent dyes for multicolor analysis. When combined with Annexin V-PE, RedNucleus II was excluded from living cells and early apoptotic cells, while late apoptotic cells and dead cells were double-positive for Annexin V-PE and RedNucleus II. Annexin V-PE / RedNucleus II apoptosis detection kit can be detected by flow cytometry or other fluorescence detection equipment. Components: Components A598354(10T) A598354(50T) A598354(100T) A. 1×Annexin V Combining buffer solution 10 mL 50 mL 50 mL×2 B. Annexin V-PE 50 µL 250 µL 500 µL C. RedNucleus II 100 µL 500 µL 1 mLProduct parameters:Annexin v-pe:ex/em=488/578 nmrednucleus ii:ex/em=635/695 NMUsage method:1. Experimental design: Blank tube: Negative control group cells, without Annexin V-PE/RedNucleus II. Used to regulate voltage.Single staining tube: Positive control group cells were treated with Annexin V-PE alone/RedNucleus II alone. Used for adjusting compensation.Detection tube: Add Annexin V-PE/RedNucleus II to the processed cells. After adjusting the voltage compensation using blank tubes and single dye tubes, obtain the required flow data.2. Collect cells(1) For suspended cells:a. After inducing cell apoptosis, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, collect the cells, gently resuspend the cells in PBS, and count them.Note: PBS resuspension cannot be omitted. The process of PBS resuspension also serves to wash cells, ensuring the subsequent binding of Annexin V-PE.b. Take 5 × 104-1 × 105 resuspended cells, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, and add 100 µ L of 1 × Annexin V binding buffer to gently resuspend the cells. c. Add 5 µ L Annexin V-PE and mix gently.d. Add 5 µ L of RedNucleus II staining solution and mix gently.e. Incubate at room temperature (20-25 º C) in the dark for 15 minutes. Aluminum foil can be used to avoid light. During the incubation process, cells can be resuspended 2-3 times to improve staining efficiency.(2) For adherent cells:a. Suck out the cell culture medium into a suitable centrifuge tube, wash the adherent cells with PBS once, and add an appropriate amount of trypsin cell digestion solution (without EDTA) to digest the cells. Incubate at room temperature until gently blowing can remove the trypsin cell digestion solution when the adherent cells are blown down. Overdigestion of pancreatic enzymes should be avoided.Note: For adherent cells, the trypsin digestion step is crucial. If the trypsin digestion time is too short, cells need to be blown hard to detach, which can easily cause damage to the cell membrane and lead to false positives of cell necrosis; If the digestion time is too long, it can also cause cell membrane damage and false positives of cell necrosis, and even affect the binding of phosphatidylserine and Annexin V-PE on the cell membrane, thereby interfering with the detection of cell apoptosis.b. Add the cell culture medium collected in the previous step, gently blow down the cells, transfer them to a centrifuge tube, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, collect the cells, gently resuspend the cells in PBS and count them.Note: Adding the cell culture medium from the previous step is very important. On the one hand, it can collect cells that have already been suspended and undergone apoptosis or necrosis. On the other hand, the serum in the cell culture medium can effectively inhibit or neutralize residual trypsin. The residual trypsin will digest and degrade the subsequently added Annexin V-PE, leading to staining failure.c. Take 5 × 104-1 × 105 resuspended cells, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, and add 100 µ L of 1 × Annexin V binding buffer to gently resuspend the cells. d. Add 5 µ L Annexin V-PE and mix gently.e. Add 5 µ L of RedNucleus II staining solution and mix gently.f. Incubate at room temperature (20-25 º C) in the dark for 15 minutes. Aluminum foil can be used to avoid light. During the incubation process, cells can be resuspended 2-3 times to improve staining efficiency.3. Result analysis:(1) Flow cytometry detection:a. After incubation, 400 µ L of 1 × Annexin V binding buffer can be directly added to resuspend the cells, and immediately detected on the machine. Annexin V-PE is excited by 488 nm/566 nm laser, and the fluorescence emission spectrum is detected at 578 nm (BL2 (FL2)/YL1 channel), while the RedNucleus II channel emission spectrum is approximately at 695 nm (RL1 (FL4) channel).b. On the scatter plot of the bivariate flow cytometer, live cells are shown in the lower left quadrant, which is (Annexin V-PE -/RedNucleus II -); The lower right quadrant represents early apoptotic cells, which are (Annexin V-PE+/RedNucleus II -); The upper right quadrant represents necrotic and late stage apoptotic cells, which are (Annexin V-PE+/RedNucleus II+); The upper left quadrant displays naked nuclear cells, which are (Annexin V-PE -/RedNucleus II+).(2) Fluorescence microscopy detection:a. Centrifuge at 1000 rpm for 5 minutes, collect cells, and gently resuspend them in 400 µ L of 1 × Annexin V binding buffer. Transfer the cells to a 96 well plate and settle for a moment or perform cell smear, then observe under a fluorescence microscope.b. Annexin V-PE is compatible with PE filters. RedNucleus II can use a far red long pass filter.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. to reduce the process of apoptosis, the incubation process can be operated on ice, but the incubation time should be extended to at least 30 min. 3. as apoptosis is a rapid process, it is recommended that samples be analyzed within 1 h after staining. 4. for adherent cells, digestion is a key step. If there are floating cells when adherent cells induce apoptosis, the floating cells and adherent cells should be collected and stained. Handle adherent cells with care to avoid artificial damage to cells. The trypsin digestion time is too short, and the cells need to be blown hard to fall off, which is easy to cause damage to the cell membrane and excessive intake of rednucleus II; If the digestion time is too long, the cell membrane is also prone to damage, and even affect the binding of phosphatidylserine and annexin v-pe on the cell membrane. When digesting, spread pancreatin on the bottom of the well plate, fully contact the pancreatin with the cells when shaking gently, then pour out most of the pancreatin, use the remaining small amount of pancreatin to digest for a period of time, and terminate when the gap between cells increases and the bottom of the bottle is spotted. Try not to use EDTA in the digestive juice, which will affect the binding of annexin V to PS. 5. after the adherent cells are digested with trypsin, it is recommended to stain after recovering in the optimal culture conditions and medium for about 30 min to avoid false positives. 6. in order to avoid losing cells when washing cells, you can use a large tip over a small tip to aspirate. 7. the optimal concentration of dye is determined by the specific experimental requirements. 8. fluorescent dyes have quenching problems. Please try to avoid light during storage and use to slow down fluorescence quenching. 9. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Early apoptosis detection, annexin V Kit... Read More | Product introduction:Dualucif The firefly & Renilla assay kit (dual luciferase reporter assay kit) provides an effective means to detect the expression of genes. In DLR detection, the activities of firefly luciferase and Renilla luciferase can be detected in a single sample in turn. FirstProduct introduction:Dualucif The firefly & Renilla assay kit (dual luciferase reporter assay kit) provides an effective means to detect the expression of genes. In DLR detection, the activities of firefly luciferase and Renilla luciferase can be detected in a single sample in turn. First, luciferin was used as substrate to detect the activity of firefly luciferase, then substances inhibiting the catalysis of firefly luciferase were added, and coelenterazine was added to detect the activity of Renilla luciferase to achieve dual luciferase reporter gene detection. The bioluminescence system of luciferase and its substrate can detect gene expression very sensitively and efficiently. Usually, the transcriptional regulatory element or 5'promoter region of the gene of interest is cloned upstream of luciferase, or the 3'-utr region is cloned downstream of luciferase to construct a reporter gene plasmid, and then transfect the cells. After the cells are treated with appropriate drugs, the cells are lysed, and the transcriptional regulation effect of drug treatment on the target gene is judged by detecting the luciferase activity. Renilla luciferase is more often used as an internal reference for detecting transfection efficiency to eliminate the difference in cell number and transfection efficiency. Firefly luciferase is a protein with a molecular weight of about 61 kDa. In the presence of ATP, magnesium ions and oxygen, it can catalyze the production of oxyluciferin from luciferin. In the process of luciferin oxidation, it will produce a light signal. Renilla luciferase is a protein with a molecular weight of about 36 kDa. In the presence of oxygen, it can catalyze the oxidation of coelenteramide to coelenteramide, and also produce light signals in the process of coelenteramide oxidation. The optical signal of this kit can be measured by chemiluminescence instrument, microplate reader or liquid scintillation tester. The kit has the characteristics of rapid detection, high sensitivity, wide detection range and no interference of cell endogenous activity.Instruction:1.Cell lysis ( 1 ) Remove the medium and gently wash twice with PBS ( adherent cells can be operated directly, suspension cells need to be centrifuged to collect cells ). Add 1 × Lysis Buffer ( diluted component A with sterile water at 4 : 1 ) according to the following scheme, and then place the culture plate on a micro-oscillator at room temperature for 15 min to fully lyse the cells. Note : The pyrolysis products can be stored at room temperature for 6 h, and can be stored at − 70 °C for a long time ( the pyrolysis products cannot be repeatedly frozen and thawed ). ( 2 ) The pyrolysis products were centrifuged at 10000-15000 rpm for 3-5 min. After centrifugation, the supernatant was transferred into a new EP tube for subsequent detection. Note : Cells can be detected immediately after lysis, or frozen, and re-detected when needed. The frozen samples need to be thawed to room temperature for detection. 2. Preparation of working fluid ( 1 ) Restore all components to room temperature. ( 2 ) Dilute component C with component B to 0.2 mg / mL firefly luciferase working solution. Note : The firefly luciferase working solution cannot be repeatedly frozen and thawed. If the amount of a single experiment is small, it is recommended to be subpackaged into small specifications according to a single amount of use. ( 3 ) The E component was diluted into the renilla luciferase working solution with the D component, and the dilution method was 1 µL E component was added to the 49 µL D component. Note : Renilla luciferase working solution needs to be prepared now. 3.chemiluminescence value detection ( 1 ) According to the operation instructions of the instrument, the instrument with chemiluminescence detection function was opened, such as multifunctional microplate reader. The parameters were set, the determination time was 10 s, and the determination interval was 2 s. ( 2 ) each sample determination, take the sample 20-100 µL ( if the sample volume is enough, please add 100 µL ; if the sample amount is insufficient, the amount can be appropriately reduced, but the amount of detection holes needs to be consistent ). 1 × Lysis Buffer was blank control. ( 3 ) 100 µL firefly luciferase working solution was added to determine the RLU ( relative light unit ) value ( it is recommended that the microplate reader set up the Shaking mixing function ). Note : Since the luminescence is instantaneous, it is recommended to detect immediately after adding the firefly luciferase working solution. ( 4 ) 100 µL renilla luciferase working solution was added to determine the RLU ( relative light unit ) value ( Shaking mixing function is recommended for microplate reader ). ( 5 ) In the case of renilla luciferase as an internal reference, the RLU value measured by firefly luciferase was divided by the RLU value measured by renilla luciferase. According to the obtained ratio, the activation degree of the target reporter gene between different samples was compared. If firefly luciferase is used as an internal reference, similar calculations can also be performed.Component:Recommendation:It is recommended to use component B in advance to prepare 2 mg / mL storage solution, component B, component D and component C prepared as storage solution, and to carry out small batch packing according to the experimental requirements. All test working fluids are recommended to be used now to avoid repeated freezing and thawing.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. in order to obtain the best determination effect, when using a single tube chemiluminescence instrument for determination, the time from the mixing of sample and determination reagent to the pre determination should be controlled as much as possible; When using a multi-functional fluorescent microplate reader with chemiluminescence detection function, it is advisable to add all samples first, and then uniformly add firefly luciferase detection reagent. 3. the strongest wavelength of firefly luciferase catalyzed bioluminescence is 560 nm, and the strongest wavelength of Renilla luciferase catalyzed bioluminescence is 480 nm. 4. to prevent interference between holes, it is recommended to use white opaque orifice plate. 5. due to the influence of temperature on enzyme reaction, the sample and reagent should be measured after reaching room temperature. 6. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Study on gene expression regulation and promoter... Read More | Products contentProducts IntroductionThis product uses the principle that the difference between the concentration of salt ions inside and outside the cell can cause the cell membrane to burst to lyses the cell and releases the genomic DNA, without the need of extracting and purifying the genomic Products contentProducts IntroductionThis product uses the principle that the difference between the concentration of salt ions inside and outside the cell can cause the cell membrane to burst to lyses the cell and releases the genomic DNA, without the need of extracting and purifying the genomic DNA.This product is suitable for a variety of sources of samples, and can be used as a template for PCR and qPCR experiments after sample processing, and can achieve the effect of the purified DNA used as a template for PCR and qPCR experiments. Usage1. Depending on the type of sample, prepare the appropriate sample size according to the table below.2. Add the sample to a 1.5-mi centrifuge tube and add the recommended volume of Solution A as shown in the table below. Vortex for 20 s and allow to stand at room temperature for 3-5 min or incubate in a metal bath at 95°C for 3-5 min as recommended in the table below.3. After the sample has been sufficiently lysed (samples incubated in a metal bath at 95°C should be brought to room temperature), add the recommended volume of Solution B as shown in the table below and vortex for 30s.4. Store processed samples at 4°C if the next test is to be performed within 2 hours, or at -20°C if the next test cannot be performed immediately.take note of1) Depending on the requirements of the experimental conditions, the amount of samples can be expanded or reduced, and the amount of Solution A and Solution B can be increased in equal proportions.2) For blood and cell samples, the temperature of room temperature lysis is required to be around 25C. If the ambient temperature does not reach 25°, the lysis time can be extended appropriately, or the vortex shaking time can be extended to ensure that the samples are fully lysed. If there is no relevant professional instrument, the centrifuge tube can be shaken vigorously to ensure adequate lysis.3) After the tissue sample is made into tissue homogenate by adding 10 times the volume of saline, it can be processed in the same way as blood samples.4) Strictly prohibit the use of expired products, please do not mix different reagents.5) laboratory supplies should be regularly cleaned and 10% of the 84 disinfectant solution or ultraviolet lamp for anti-pollution treatment, special areas dedicated to prohibit cross use, so as to avoid contamination, the end of the test, the bench should be cleaned immediately... Read More | DescriptionMaterials included in the kit are designed to be used with the Hy-Energy′s PCTPro-2000 System. They also can be used for demonstration purposes and as standards during the development of novel hydrogen storage and battery materials |