| Description | Inquire | Format:2-ComponentEnzyme:Horseradish peroxidase | Product content: Component G665666 200 preps Buffer P1 60ml Buffer P2 60ml Buffer E3 60ml Buffer PW (concentrate) 25ml Buffer EB 30ml RNase A (10 mg/ml) 600 µl Spin Columns DM 200 with Collection Tubes 200Product Introduction:This reagent kit is suitable for extracting 1-5 ml of Product content: Component G665666 200 preps Buffer P1 60ml Buffer P2 60ml Buffer E3 60ml Buffer PW (concentrate) 25ml Buffer EB 30ml RNase A (10 mg/ml) 600 µl Spin Columns DM 200 with Collection Tubes 200Product Introduction:This reagent kit is suitable for extracting 1-5 ml of bacterial solution. On the basis of alkaline lysis of cells, it efficiently and specifically binds plasmid DNA through a new silicon-based membrane. Each adsorption column can adsorb up to 40% µ The plasmid DNA of g is effectively removed with a special buffer system to effectively remove impurities such as proteins. The yield and purity of plasmids obtained from this kit are high, and the quality is stable. It is suitable for downstream experiments such as cell transfection, DNA sequencing, PCR, PCR based mutations, in vitro transcription, transformed bacteria, and endonuclease digestion.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1. All components can be stably stored for 1 year in a dry, room temperature (15-30 ℃) environment. The adsorption column can be stored for a longer time at 2-8 ℃. 2.Buffer P1 with RNase A added can be stably stored for 6 months at 2-8 ℃. Before use, add RNase A to Buffer P1 (add all RNase A provided in the reagent kit), mix well, and store at 2-8 ℃. Before use, it is necessary to leave it at room temperature for a period of time, and then use it after returning to room temperature.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer P2 and Buffer E3. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. Note that Buffer P2 and Buffer E3 contain irritating substances. Please wear gloves when operating and immediately cover the lid after use.6.The amount and purity of plasmid extraction are related to factors such as bacterial culture concentration, strain type, plasmid size, and plasmid copy number.7. The maximum volume of Spin Columns DM is 750 µ l. If the sample volume is greater than 750 µ L can be added in batches.Operation steps:1. Take 1-5 ml of overnight cultured bacterial solution and add it to a centrifuge tube (provided). Centrifuge at 13000 rpm (~16200 × g) for 1 minute to collect bacteria, and try to discard all the supernatant as much as possible.2. Add 200 to the centrifuge tube containing bacterial sediment µ Buffer P1 (please check if RNase A has been added first), mix thoroughly with a pipette or vortex oscillator, and suspend bacterial precipitation.Attention: If the bacterial blocks are not thoroughly mixed, it will affect the cracking effect, resulting in low extraction amount and purity.3. Add 200 to the centrifuge tube µ Buffer P2, gently invert and mix 8-10 times to fully lyse the bacterial cells. At this point, the solution should become clear and viscous.Attention: Mix gently and do not shake vigorously to avoid interrupting genomic DNA and mixing genomic DNA fragments in the extracted plasmid. If the solution does not become clear, it indicates that the bacterial count may be too large and the lysis may not be complete. The bacterial count should be reduced or the dosage of P1, P2, E3, and isopropanol should be increased proportionally.4. Add 200 to the centrifuge tube µ Buffer E3, immediately invert and mix 8-10 times, at which point white flocculent precipitates appear. Centrifuge at 13000 rpm for 5 minutes.Attention: After adding Buffer E3, it should be mixed evenly immediately to avoid local precipitation.5. Add 260 to the spin columns DM that have been loaded into the collection tube µ After adding isopropanol, immediately add the supernatant collected in step 4 and mix it upside down.Attention: After adding isopropanol, immediately add the supernatant and mix well to avoid isopropanol dripping into the collection tube after being left for a long time. The maximum volume of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ l. Isopropanol and the supernatant can be collected in a centrifuge tube (provided by oneself), mixed well, and passed through the column in batches.6.13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 400 to the adsorption column µ L Buffer PW (please check if anhydrous ethanol has been added first), centrifuge at 13000 rpm for 1 minute, and discard the waste liquid in the collection tube.8. Place the adsorption column in a new collection tube and add 50-100 to the middle of the adsorption membrane µ Centrifuge at 13000 rpm for 1 minute using buffer EB and collect the plasmid solution into a centrifuge tube- Store the plasmid at 20 ℃.Note: 1) To increase the efficiency of plasmid recovery, the obtained solution can be added back to the adsorption column, left at room temperature for 2-5 minutes, centrifuged at 13000 rpm for 2 minutes, and collected into a centrifuge tube.2) When the plasmid copy number is low or>10 kb, preheating the buffer EB in a water bath at 65-70 ℃ can increase the extraction efficiency... Read More | Product content Q665687Component100 TStorageQ665687AQuick T4 DNA Ligase (15 U/µL)100 µL-20℃. Avoid freeze/thaw cycle.Q665687B2×Quick Ligation Reaction Buffer5×200 µL-20℃. Avoid freeze/thaw cycle. Product IntroductionThe Quick Ligation Reaction Kit allows ligationProduct content Q665687Component100 TStorageQ665687AQuick T4 DNA Ligase (15 U/µL)100 µL-20℃. Avoid freeze/thaw cycle.Q665687B2×Quick Ligation Reaction Buffer5×200 µL-20℃. Avoid freeze/thaw cycle. Product IntroductionThe Quick Ligation Reaction Kit allows ligation of DNA sticky or flush ends in 5 minutes at room temperature (25°C). The kit contains Quick T4 DNA Ligase and 2×Quick Ligation Reaction Buffer optimized for fast and efficient DNA ligation.The ligation efficiency of Quick Ligation is equivalent to 1 hour of conventional ligation with T4 DNA Ligase. The Quick Ligation products can be used directly in routine bacterial transformation experiments.matters needing attention1. This kit enables most of the linkage reactions to reach the reaction endpoint within 5 minutes or less at 25°C. Increasing the reaction time will not enhance the reaction efficiency. If you use the rapid connection reaction after 1 hour, the conversion efficiency will be significantly reduced; if the rapid connection reaction at 25 ℃ overnight, the conversion efficiency will drop to 75%.2. 2×Quick Ligation Reaction Buffer contains ATP, which should be thawed on ice and mixed thoroughly before use. It is recommended to freeze the buffer in small tubes for the first time, so as to avoid repeated freezing and thawing, which will affect the efficiency of DNA ligation.3. Since T4 DNA Ligase contains glycerol, which is sticky and easy to hang on the wall, it is recommended to collect the liquid to the bottom of the tube by centrifugation for a short period of time before use, and the tip of the lance should not go too deep into the liquid surface when taking samples to avoid sticking to the tip of the lance and causing losses.4. If the quick ligation product is used for electrotransformation, the PEG in the quick ligation reaction system will affect the efficiency of electrotransformation, and it is recommended to use a centrifugal column to purify the ligation product from DNA before electrotransformation.Usage1. The reaction solution was prepared according to the following system:*The amount of Insert DNA used: the molar ratio of Vector DNA and Insert DNA is generally 1:3-1:8, and the appropriate molar ratio of Vector DNA and Insert DNA can be selected according to the experimental situation.Calculation of DNA molar number: DNA molar number (nmol)=DNA mass (ng)/( 660daltons x number of inserted DNA bases bp).2. mix gently and centrifuge briefly. react at 25°C for 5 minutes.Note: The reaction time should not exceed 15 minutes, otherwise the connection efficiency will be reduced.3. Do not perform heat inactivation reactions. Centrifuge instantly and collect the solution from the wall to the bottom of the tube.Note: Heat inactivation significantly reduces transformation efficiency due to the presence of PEG in the buffer.4. After the reaction, store the DNA ligation product at 0-4℃, and then carry out transformation experiments; you can also store the DNA ligation product at -20℃.Note: When transforming by chemical method, do not add more than 10% of the volume of the receptor cell for the ligation product.5. Heat shock the ligation product to transform 50 µl of receptor cells or take 1-2 µl of ligation product to electroshock transform 50 µl of receptor cells.Note: 1) When transforming by chemical method, do not add more than 10% of the volume of the receptor cell for the ligation product.(2) If the quick ligation product is used for electrotransformation, it is recommended to use a centrifugal column to purify the ligation product from DNA before electrotransformation because the PEG in the quick ligation reaction system will affect the efficiency of electrotransformation... Read More | Products contentProducts IntroductionThe Single Cell Whole Genome Amplification Kit can be used as a template for whole genome amplification of single cells or micro samples. The total time for single-cell amplification is about 3 hours, and 2-5 µg of genomic DNA, with a size of 200-1500 bp, Products contentProducts IntroductionThe Single Cell Whole Genome Amplification Kit can be used as a template for whole genome amplification of single cells or micro samples. The total time for single-cell amplification is about 3 hours, and 2-5 µg of genomic DNA, with a size of 200-1500 bp, can be obtained after lysis, pre-amplification and amplification. The amplified product can be widely used in second-generation sequencing, large fragment copy number variation analysis, SNP typing, qPCR analysis and gene chip analysis.Bring your own instruments and reagentsPCR instrument Reaction tubes: low adsorption tubes recommended Gun Heads: High quality filtered gun heads are recommended Microcentrifuge, vortex mixercaveat The sensitivity of this product is very high, the experimental operation should be completed in a positive pressure ultra-clean bench or clean environment, the concentration of the amplification reaction products is high, should be well isolated to avoid aerosol contamination caused by amplification products.Operation flow diagramprocedurePre-experiment preparationSingle cells were obtained by flow cytometry sorting, buffer dilution, micromanipulation and laser microdissection. It is recommended that the cells be washed prior to the experiments with a 1× PBS solution free of Mg2+ and Ca2+, taking care to ensure that the volume of PBS solution in subsequent experiments does not exceed 2 µl. take note of Since the whole experiment is carried out in the same PCR tube and the reaction volume is small, the pipette tip should not touch the liquid in the tube when adding liquid, so as to avoid taking single cells or DNA out of the reaction system; when pipetting, please add the liquid along the wall of the tube carefully and do not blow the liquid in the PCR tube; before the reaction, please centrifuge briefly to make sure that the liquid in the reaction system is mixed evenly. Thaw the cell lysate, pre-amplifier and amplifier on ice before use.cell lysis 1)Mix Cell Lysis Buffer and Cell Lysis Enzyme according to the number of reactions N, shake to mix, centrifuge briefly and set aside.2)Mix single cells with the cell lysis mix in a PCR tube and run the following program.2. Pre-amplification reaction1)Mix Cell Lysis Buffer and Cell Lysis Enzyme according to the number of reactions N, shake to mix, centrifuge briefly and set aside.2)Add 5 µl of pre-amplification mix to 10 µl of lysis reaction product from the previous step and run the following program. 3. Amplification reaction1)Mix Amplification Buffer and Amp Enzyme Mix according to the number of reactions N, mix with shaking, centrifuge briefly and set aside.2)Add 60 µl of amplification mix to 15 µl of pre-amplification reaction product from the previous step and run the following program.Note: The number of cycles can be adjusted as needed, 14 cycles are recommended for single cells obtained by flow sorting, etc.Amplification product detection 1. Agarose gel electrophoresis 5 µl of the amplified product was subjected to agarose gel electrophoresis (1% agarose gel, 110 V, 25-35 min), and the amplified product was 200-1500 bp in size. 2. Quantitative Amplification products were subjected to magnetic bead or column purification, and purified products were quantified using Qubit with a final yield of 2-5 µg... Read More |