| Description | Inquire | DescriptionCobalt is a transition metal that serves as a trace dietary mineral for all multicellular organisms. Cobalt is an important cofactor for the Vitamin B12class of compounds where it occupies the center of the vitamin B12corrin ring. Cobalt can also be coordinated in the active site of the DescriptionCobalt is a transition metal that serves as a trace dietary mineral for all multicellular organisms. Cobalt is an important cofactor for the Vitamin B12class of compounds where it occupies the center of the vitamin B12corrin ring. Cobalt can also be coordinated in the active site of the non-corrin containing metalloenzyme methionine aminopeptidase.Suitability: Suitable for quantitating cobalt concentrations in a variety of samplesPrinciple: The Cobalt Assay kit provides a simple and direct procedure for measuring cobalt in a variety of samples. In this assay, cobalt reacts with 2-mercaptoethanol under basic conditions to form a complex with a strong absorbance at 475 nm. Interference from the metal ions Fe2+, Cu2+, Ni2+, Zn2+, and Mn2+is <10% at this wavelength. This assay gives a linear range of 10-50 nmoles of cobalt.}Preparation instructionsSuitable for quantitating cobalt concentrations in a variety of samplesPrincipleThe Cobalt Assay kit provides a simple and direct procedure for measuring cobalt in a variety of samples. In this assay, cobalt reacts with 2-mercaptoethanol under basic conditions to form a complex with a strong absorbance at 475 nm. Interference... Read More | N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917D DNA Standard B 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917E DNA Standard C 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917F DNA Standard D 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917G DNA Standard E 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis is a dye-based (SYBR Green I) qPCR NGS library quantification kit for cfDNA, which provides the reaction mixture, DNA primer mixture, standards, and sample dilutions required for the qPCR process, making it a complete reagent system that is easy and convenient to use. The fluorescent dye SYBR Green I contained in the reaction mixture binds to all double-stranded DNA. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, the length of the standard in the kit (about 270bp) is comparable to the average length of the cfDNA NGS libraries (250-300bp), which is able to quickly and accurately quantitate the concentration of the constructed cfDNA libraries. quantification.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.NOTE: High Rox and Low Rox are formulated as described in Method of Use 2.Applicable scopeThis product is designed for the absolute quantification of the concentration of Illumina platform second generation sequencing libraries. The end of the library contains Illumina P5 and P7 microarray binding sequences, the length of which does not exceed 1kb, and the concentration is not less than 0.02pM can be used for quantitative experiments. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-60 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR MasterMix10 µlqPCR Primer Mix0.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: 1 µl High Rox per 50 µl of reaction system; Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.3.qPCR reaction programIf the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.Refer to the specific instrument setup program for dissolution curves.data analysisStandard curve productionThe standard curve was plotted according to the data processing Excel sheet. The correlation coefficient R2 of the standard curve should be not less than 0.99, and the slope should be located between -3.1 and -3.6 when the Ct value is the longitudinal coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard A60 pMDNA Standard B6 pMDNA Standard C0.6 pMDNA Standard D0.06 pMDNA Standard E0.006 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More | DescriptionWhite LED Array for Photo KitAlysis high-throughput screening platform. For use with Photo KitAlysis Starter Kit (Z742612). User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsFeatures:Designed and tested by synthetic chemists.Controller provides repeatableDescriptionWhite LED Array for Photo KitAlysis high-throughput screening platform. For use with Photo KitAlysis Starter Kit (Z742612). User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsFeatures:Designed and tested by synthetic chemists.Controller provides repeatable milliamp selection for photon intensity (sold seperately)0-30 mA variable LED outputNon-magnetic LED baseChemically resistant LED coverPTFE coated cablingPhoto Kitalysis Starter Kitrequired for operation (sold separately). Best when used withKitAlysis Benchtop Inertion Box(sold separately)... Read More | Product contentY666144Component50 TStorageY666144ABuffer P115 mLRTY666144BBuffer P215 mLRTY666144CBuffer N320 mLRTY666144DBuffer PS15 mLRTY666144EBuffer PB10 mLRTY666144FBuffer PW (concentrate)10 mLRTY666144GBuffer EB10 mLRTY666144HGlass Beads2 gRTY666144IRNase A (10mg/mL)150 µLRTY666144JSpin Product contentY666144Component50 TStorageY666144ABuffer P115 mLRTY666144BBuffer P215 mLRTY666144CBuffer N320 mLRTY666144DBuffer PS15 mLRTY666144EBuffer PB10 mLRTY666144FBuffer PW (concentrate)10 mLRTY666144GBuffer EB10 mLRTY666144HGlass Beads2 gRTY666144IRNase A (10mg/mL)150 µLRTY666144JSpin Columns DM with Collection Tubes50 setsRTProductsThis kit is improved on the basis of common alkaline lysis method, the glass beads can effectively break the yeast cell wall, the new silica matrix membrane and buffer system can efficiently and specifically bind the plasmid DNA, and at the same time can maximize the removal of proteins and other impurities, the whole process is convenient and fast, no need to use toxic and harmful reagents, and can be processed at the same time for multiple samples. In addition to yeast cells, it can also be used in E. coli. Plasmid DNA extracted with this kit can be used in various molecular biology experiments, such as ligation, transformation, sequencing and library screening.Self-contained reagents: β-mercaptoethanol, anhydrous ethanol.Pre-experiment Preparation and Important Notes1. All components can be stably stored in dry, room temperature (15-30℃) environment for 1 year, the adsorption column can be stored at 2-8℃ for a longer period of time, and Buffer P1 with RNase A can be stably stored at 2-8℃ for 6 months.2. Before the first use, add all the RNase A solution to Buffer P1, mix well, and store at 2-8℃.3. Anhydrous ethanol should be added to Buffer PW before first use according to the instructions on the reagent bottle label.4. Before use, please check whether Buffer P2 and Buffer N3 are crystallized or precipitated. If there is any crystallization or precipitation phenomenon, it can be clarified by taking a water bath at 37℃ for a few minutes to restore the clarity.5. Be careful not to touch Buffer P2 and Buffer N3 directly, and tighten the lid immediately after use.6. The amount of plasmid extracted is related to the yeast strain, plasmid copy number, culture conditions, etc. Usually, yeast plasmid copy number is very low, which is difficult to be detected by electrophoresis or spectrophotometer method.Procedure1. Take 1-5 ml of yeast culture (maximum 5×107 yeast cells, generally for Saccharomyces cerevisiae OD = 1.0, equivalent to 1-2×107 cells/ml) and add it to a centrifuge tube (self-provided), centrifuge for 30 seconds at 12,000 rpm (~13,400×g), collect the bacterial precipitate, and aspirate as much as possible to discard the supernatant.2. Add 250µl Buffer P1 to the bacterium (please check if RNase A has been added first) and resuspend the precipitate.3. Add 40mg of Glass Beads to the above mixture and vortex and shake for 10 minutes.4. Add 250 µl of Buffer P2 to the centrifuge tube, mix gently by turning up and down 6-8 times, and let stand at room temperature for 5-10 minutes, at which time the bacterial solution should become clear and viscous.Note: Mix gently, do not shake violently, so as not to interrupt the genomic DNA, resulting in genomic DNA fragments mixed in the extracted plasmid. If the solution does not become clear, it suggests that the amount of bacteria may be too large and the lysis is not complete, and the amount of bacteria should be reduced.5. Add 350 µl of Buffer N3 to the centrifuge tube and immediately mix gently up and down 6-8 times, at which point a white flocculent precipitate appears, and centrifuge at 12,000 rpm for 20 minutes.Note: Buffer N3 should be mixed immediately after addition to avoid localized precipitation.6. Column Equilibration: Add 200 µl of Buffer PS to the Spin Columns DM in the collection tube, centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid from the collection tube, and place the column back into the collection tube.7. Add the supernatant from step 5 to the adsorbent column that has been loaded into the collection tube, taking care not to aspirate the precipitate.Note: The maximum volume of the adsorption column is 750 µl, and the solution is passed through the column in 2 times.8. Centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube and place the adsorption column back into the collection tube.9. Add 150 µl Buffer PB to the adsorbent column, centrifuge at 12,000 rpm for 1 min, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.10. Add 750 µl Buffer PW to the adsorption column (please check that anhydrous ethanol has been added first), centrifuge at 12,000 rpm for 1 minute, and pour off the waste liquid in the collection tube.11. Place the column back into the recovery collection tube and centrifuge at 12,000 rpm for 2 minutes, pouring off the waste liquid. Leave the column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).12. Place the adsorbent column in a new centrifuge tube, add 50-100 µl of Buffer EB to the center of the adsorbent membrane dropwise, let it stand at room temperature for a few minutes, centrifuge at 13,000 rpm for 1 minute, and collect the plasmid solution into the centrifuge tube. Store the plasmid at -20°C.Attention:1) To increase the recovery efficiency of the plasmid, the resulting solution can be reintroduced into the adsorbent column, left at room temperature for a few minutes, centrifuged at 13,000 rpm for 1 minute, and the plasmid solution collected into a centrifuge tube.2) When the plasmid copy number is low or >10 kb, Buffer EB is preheated at 65-70°C in a water bath, which can increase the extraction efficiency.3) Usually yeast plasmids have very low copy number and are difficult to detect by electrophoresis or spectrophotometry. If the extracted plasmid is to be used in the next step of the experiment, it is usually recommended to use 1-5µl of the plasmid as PCR template, and 5-10µl of the plasmid for transformation of E. coli.4) Commercial high transformation efficiency receptor cells should be used for transformation of E. coli... Read More |