| Description | Inquire | CFDASE cell proliferation and tracking detection kit is a kit for cell proliferation and tracking detection based on CFDA se. This kit is composed of CFDASE powder, solvent and staining buffer. CFDASE is a derivative of fluorescein diacetate (FDA), which has cell membrane permeability and CFDASE cell proliferation and tracking detection kit is a kit for cell proliferation and tracking detection based on CFDA se. This kit is composed of CFDASE powder, solvent and staining buffer. CFDASE is a derivative of fluorescein diacetate (FDA), which has cell membrane permeability and does not have fluorescence luminescence. When CFDASE penetrates the cell membrane into living cells, it can be catalysed by esterases in the cytosol to produce carboxyfluorescein succinimidyl ester (CFSE), which can emit strong green fluorescence, cannot penetrate the cell membrane, and can remain intact in the cell. CFSE can also spontaneously and irreversibly covalently bind to intracellular amino groups to couple to cellular proteins. Meanwhile, the excess and uncoupled CFDASE returned to the extracellular medium by passive diffusion and was cleared by subsequent washing steps. The fluorescence of non dividing cells labeled by CFDASE is very stable, and the stable labeling time can reach several months, so it is very suitable for cell community analysis. The fluorescence of CFDASE labeled cells is very homogeneous, which is superior to other cell tracking fluorescent probes used previously, such as PKH26, and the fluorescence distribution of the divided progeny cells is also very uniform. In the process of cell division and proliferation, CFSE labeled fluorescence can be evenly distributed to the two progeny cells, and the fluorescence intensity becomes half of the parental cells. According to the fluorescence intensity, flow cytometer (FL1 channel) can detect undivided cells, cells that divide once (1 / 2 of the fluorescence intensity), twice (1 / 4 of the fluorescence intensity), three times (1 / 8 of the fluorescence intensity), and cells that divide more times. CFDASE can detect up to eight or more cleavages. CFDASE labeled cells can be used for proliferation studies in vitro and in vivo, and have the function of not staining adjacent cells. CFDASE is most commonly used to detect the proliferation of lymphocytes, and can also be used to detect the proliferation of fibroblasts, NK cells and other cells. CFDASE labeled cells showed green fluorescence. In addition to flow cytometry to detect cell proliferation, fluorescence microscopy can also be used for homogeneous staining of cell tracking observation.Components:ComponentsC598182-20TC598182-500TA. CFDA SE1 tube1 tubex5B.CFDA SE solvent20 µL500 µLC.10x CFDA SE Buffer1 mL x250 mLMatters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. CFDA and Se are easily hydrolyzed and will deteriorate quickly in aqueous solution. Please avoid contact with water during use. Contact with water during the process of labeling cells is within the permitted range. 3. CFDA se solvent will solidify at lower temperatures such as 4 º C and ice bath and stick to the bottom, wall or cover of the centrifugal tube. It can be used after incubating in a 20-25 º C water bath for a while until it is completely dissolved. 4. this kit optimizes the CFDA se staining system, but users are advised to explore the optimal working concentration and staining time according to their own cell type, culture conditions and application direction. Different cells have different lactonase activities, so the staining effect is different. 5. fluorescent dyes have quenching problems. Please avoid light during operation to slow down fluorescence quenching. 6. for your safety and health, please wear experimental clothes and disposable gloves.Usage method:1. Preparation of reagents(1) Preparation of CFDA SE storage solution: Take one tube of CFDA SE provided in the reagent kit and restore it to room temperature. Instantly centrifuge to allow the powder to fully settle to the bottom of the tube. Add 100 µ L CFDA SE solvent (add 20 µ L CFDA SE solvent) to it and dissolve it thoroughly to prepare CFDA SE storage solution (1000 ×). Prepared CFDA SE storage solution, stored at -20 ℃ in the dark, with a shelf life of two months- Storing at 70 ℃ in the dark can extend the usage time appropriately.(2) Preparation of CFDA SE Buffer: Dilute 10 x CFDA SE Buffer to 1 x with sterile cell culture grade water as needed. The prepared 1 × CFDA SE Buffer can be stored at 4 ℃ and can be stored at -20 ℃ if not in use for a long time.2. Marking and detection(1) Centrifuge the collected cells, use 1 mL 1 × CFDA SE Buffer to re suspend the cells in a 15 mL centrifuge tube, and adjust the cell concentration to 1-5 × 106 cells/mL.(2) Preparation of CFDA SE working solution: Dilute the CFDA SE storage solution (1000 ×) with 1 × CFDA SE Buffer to 2 ×.(3) Staining: Add 1 mL of CFDA SE working solution (2 x) to 1 mL of cell suspension to be labeled, invert and mix well, and incubate at 37 ℃ for 10 minutes.(4) Immediately add 5 times the volume of preheated complete culture medium (including serum) to the centrifuge tube, invert and mix well to terminate the labeling reaction.(5) Centrifuge at 1000 rpm for 5 minutes at room temperature to remove the supernatant, then wash once with 5-10 mL of complete culture medium.(6) Add 5-10 mL of complete culture medium and incubate at 37 ℃ for 5 minutes to promote the residence of CFDA SE in the cells and the entry of unreacted CFDA SE into the complete cell culture medium. Centrifuge at 1000 rpm for 5 minutes at room temperature to remove the supernatant and complete the final wash.(7) Subsequently, the cells can be cultured using the normal cultivation method. The labeling effect can be directly observed under a fluorescence microscope, or cell proliferation can be detected by flow cytometry after appropriate cultivation time, showing green fluorescence. The labeled cells can also be used for transplantation in live animals and for fluorescence tracing.Note: a If cell fixation is required, use aldehyde fixatives such as 4% paraformaldehyde to fix at room temperature for 15 minutes; If additional labeling such as antibody labeling is required afterwards, please permeabilize the cells with ice acetone for 10 minutes. b. The optimal labeling concentration and incubation time for CFDA SE vary for different cells. The initial experiment can be conducted according to the experimental steps. If the effect is not satisfactory, it is recommended to adjust the staining concentration and incubation time to achieve the best labeling effect.Scope of application:Cell proliferation assay... Read More | Product introduction:Dualucif The firefly & Renilla assay kit (dual luciferase reporter assay kit) provides an effective means to detect the expression of genes. In DLR detection, the activities of firefly luciferase and Renilla luciferase can be detected in a single sample in turn. FirstProduct introduction:Dualucif The firefly & Renilla assay kit (dual luciferase reporter assay kit) provides an effective means to detect the expression of genes. In DLR detection, the activities of firefly luciferase and Renilla luciferase can be detected in a single sample in turn. First, luciferin was used as substrate to detect the activity of firefly luciferase, then substances inhibiting the catalysis of firefly luciferase were added, and coelenterazine was added to detect the activity of Renilla luciferase to achieve dual luciferase reporter gene detection. The bioluminescence system of luciferase and its substrate can detect gene expression very sensitively and efficiently. Usually, the transcriptional regulatory element or 5'promoter region of the gene of interest is cloned upstream of luciferase, or the 3'-utr region is cloned downstream of luciferase to construct a reporter gene plasmid, and then transfect the cells. After the cells are treated with appropriate drugs, the cells are lysed, and the transcriptional regulation effect of drug treatment on the target gene is judged by detecting the luciferase activity. Renilla luciferase is more often used as an internal reference for detecting transfection efficiency to eliminate the difference in cell number and transfection efficiency. Firefly luciferase is a protein with a molecular weight of about 61 kDa. In the presence of ATP, magnesium ions and oxygen, it can catalyze the production of oxyluciferin from luciferin. In the process of luciferin oxidation, it will produce a light signal. Renilla luciferase is a protein with a molecular weight of about 36 kDa. In the presence of oxygen, it can catalyze the oxidation of coelenteramide to coelenteramide, and also produce light signals in the process of coelenteramide oxidation. The optical signal of this kit can be measured by chemiluminescence instrument, microplate reader or liquid scintillation tester. The kit has the characteristics of rapid detection, high sensitivity, wide detection range and no interference of cell endogenous activity.Instruction:1.Cell lysis ( 1 ) Remove the medium and gently wash twice with PBS ( adherent cells can be operated directly, suspension cells need to be centrifuged to collect cells ). Add 1 × Lysis Buffer ( diluted component A with sterile water at 4 : 1 ) according to the following scheme, and then place the culture plate on a micro-oscillator at room temperature for 15 min to fully lyse the cells. Note : The pyrolysis products can be stored at room temperature for 6 h, and can be stored at − 70 °C for a long time ( the pyrolysis products cannot be repeatedly frozen and thawed ). ( 2 ) The pyrolysis products were centrifuged at 10000-15000 rpm for 3-5 min. After centrifugation, the supernatant was transferred into a new EP tube for subsequent detection. Note : Cells can be detected immediately after lysis, or frozen, and re-detected when needed. The frozen samples need to be thawed to room temperature for detection. 2. Preparation of working fluid ( 1 ) Restore all components to room temperature. ( 2 ) Dilute component C with component B to 0.2 mg / mL firefly luciferase working solution. Note : The firefly luciferase working solution cannot be repeatedly frozen and thawed. If the amount of a single experiment is small, it is recommended to be subpackaged into small specifications according to a single amount of use. ( 3 ) The E component was diluted into the renilla luciferase working solution with the D component, and the dilution method was 1 µL E component was added to the 49 µL D component. Note : Renilla luciferase working solution needs to be prepared now. 3.chemiluminescence value detection ( 1 ) According to the operation instructions of the instrument, the instrument with chemiluminescence detection function was opened, such as multifunctional microplate reader. The parameters were set, the determination time was 10 s, and the determination interval was 2 s. ( 2 ) each sample determination, take the sample 20-100 µL ( if the sample volume is enough, please add 100 µL ; if the sample amount is insufficient, the amount can be appropriately reduced, but the amount of detection holes needs to be consistent ). 1 × Lysis Buffer was blank control. ( 3 ) 100 µL firefly luciferase working solution was added to determine the RLU ( relative light unit ) value ( it is recommended that the microplate reader set up the Shaking mixing function ). Note : Since the luminescence is instantaneous, it is recommended to detect immediately after adding the firefly luciferase working solution. ( 4 ) 100 µL renilla luciferase working solution was added to determine the RLU ( relative light unit ) value ( Shaking mixing function is recommended for microplate reader ). ( 5 ) In the case of renilla luciferase as an internal reference, the RLU value measured by firefly luciferase was divided by the RLU value measured by renilla luciferase. According to the obtained ratio, the activation degree of the target reporter gene between different samples was compared. If firefly luciferase is used as an internal reference, similar calculations can also be performed.Component:Recommendation:It is recommended to use component B in advance to prepare 2 mg / mL storage solution, component B, component D and component C prepared as storage solution, and to carry out small batch packing according to the experimental requirements. All test working fluids are recommended to be used now to avoid repeated freezing and thawing.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. in order to obtain the best determination effect, when using a single tube chemiluminescence instrument for determination, the time from the mixing of sample and determination reagent to the pre determination should be controlled as much as possible; When using a multi-functional fluorescent microplate reader with chemiluminescence detection function, it is advisable to add all samples first, and then uniformly add firefly luciferase detection reagent. 3. the strongest wavelength of firefly luciferase catalyzed bioluminescence is 560 nm, and the strongest wavelength of Renilla luciferase catalyzed bioluminescence is 480 nm. 4. to prevent interference between holes, it is recommended to use white opaque orifice plate. 5. due to the influence of temperature on enzyme reaction, the sample and reagent should be measured after reaching room temperature. 6. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Study on gene expression regulation and promoter... Read More | Product contentcomponent50T200TBuffer LP125mL100mLBuffer LP210mL40mLBuffer LP3 (concentrate)21ml84mlBuffer GW2 (concentrate)15mL75mlBuffer GE15mL60mLRNase A(10 mg/ml)300µl1.25mLSpin Columns DM with Collection Tubes50200ProductsThis kit uses centrifugal adsorption columns with highProduct contentcomponent50T200TBuffer LP125mL100mLBuffer LP210mL40mLBuffer LP3 (concentrate)21ml84mlBuffer GW2 (concentrate)15mL75mlBuffer GE15mL60mLRNase A(10 mg/ml)300µl1.25mLSpin Columns DM with Collection Tubes50200ProductsThis kit uses centrifugal adsorption columns with high efficiency and specific binding of nucleic acids and a unique buffer system, which is suitable for extracting genomic DNA from a wide variety of different fresh or frozen plant tissues with maximum removal of impurities from the plant tissues. The kit eliminates the need for phenol/chloroform extraction and is safe to handle. The extracted genomic DNA fragments are large, high purity, stable and reliable quality, suitable for PCR, fluorescence quantitative PCR, molecular labeling, library construction and other experiments.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller fragments of extracted DNA and a decrease in the amount extracted.2. Anhydrous ethanol should be added to Buffer LP3 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use. Check Buffer LP1 and Buffer LP2 for crystallization or precipitation before use. If crystallization or precipitation occurs, re-dissolve Buffer LP1 and Buffer LP2 in a 56°C water bath. Procedure1. Take about 100mg of fresh plant tissue or about 20mg of dry weight tissue and add liquid nitrogen to grind it fully.2. Collect the ground powder into a centrifuge tube (self-provided), add 400 µl Buffer LP1 and 6 µl RNase A (10 mg/ml), vortex and oscillate for 1 minute, and leave it at room temperature for 10 minutes to allow for full cleavage.Note: 1) Use vortex shaking or pipette blowing to fully lyses the tissue, incomplete tissue lysis will affect the final DNA yield. 2) Do not mix Buffer LP1 with RNase A prior to use.3. Add 130 µl Buffer LP2, mix well and vortex for 1 minute.4. Centrifuge at 12,000 rpm (~13,400 x g) for 5 minutes and transfer the supernatant to a new centrifuge tube (supplied).5. Add 1.5 times the volume of Buffer LP3 (check that anhydrous ethanol has been added before use) and mix thoroughly (e.g., 500 µl filtrate to 750 µl Buffer LP3).Note: Buffer LP3 should be mixed immediately after addition; precipitation may occur but will not affect subsequent experiments.6. Add all of the solution and precipitate obtained in the previous step to the adsorption columns (Spin Columns DM) that have been loaded into the collection tubes, if the solution cannot be added all at once, it can be transferred in several times. centrifuge the columns at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tubes, and put the columns back into the collection tubes.7. Add 500 µl of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: If the adsorbent membrane appears green, add 500 µl of anhydrous ethanol to the adsorbent column, centrifuge the column at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.8. Repeat step 7.9. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).10. Place the adsorption column in a new centrifuge tube (supplied), add 50-100 µl of Buffer GE or sterilized water dropwise to the middle of the adsorbent membrane, leave it at room temperature for 2-5 minutes, and centrifuge it at 12,000 rpm for 1 minute to collect the DNA solution. -The DNA solution was collected by centrifugation at 12,000 rpm for 1 min.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH value of the eluent has a great influence on the elution efficiency, if you use water as the eluent, you should ensure that the pH value is 7.0-8.5 (you can use NaOH to adjust the pH value of the water to this range), and when the pH value is lower than 7.0, the elution efficiency is not high.2) Incubation at room temperature for 5 minutes prior to centrifugation increases yield.(3) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 10 can be re-added to the adsorbent membrane and repeat step 10; if the elution volume is less than 100µl, the final concentration of DNA can be increased, but it may reduce the total DNA yield. If the amount of DNA obtained is less than 1µg, 50µl Buffer GE is recommended for elution.4) Because DNA stored in water is subject to acidic hydrolysis, for long-term storage, elution with Buffer GE and storage at -20°C are recommended... Read More | Product contentP666142Component200 TStorageP666142ABuffer P160 mLRTP666142BBuffer P260 mLRTP666142CBuffer N380 mLRTP666142DBuffer PB35 mLRTP666142EBuffer PW (concentrate)25 mLRTP666142FBuffer EB30 mLRTP666142GRNase A (10 mg/mL)600 µLRTP666142HSpin Columns DM with Collection Tubes200 EART Product contentP666142Component200 TStorageP666142ABuffer P160 mLRTP666142BBuffer P260 mLRTP666142CBuffer N380 mLRTP666142DBuffer PB35 mLRTP666142EBuffer PW (concentrate)25 mLRTP666142FBuffer EB30 mLRTP666142GRNase A (10 mg/mL)600 µLRTP666142HSpin Columns DM with Collection Tubes200 EART Product IntroductionThis kit is suitable for extracting 1-5 ml of bacterial solution. Based on the lysis of cells by alkaline lysis method, it adopts a unique silica matrix membrane adsorption technology and reagent formulation, and efficiently and exclusively binds plasmid DNA in solution by centrifugal adsorption columns in a high-salt state, and each adsorption column can adsorb a maximum of 30 µg of plasmid DNA, and removes proteins, genomes, RNAs, and other impurities to the greatest extent possible. The plasmid DNA obtained can be directly used for cell transfection, PCR, digestion, sequencing, ligation and other biological experiments.Self-contained reagent: anhydrous ethanol.Pre-experiment Preparation and Important Notes1. All components can be stably stored in dry, room temperature (15-30℃) environment for 1 year, the adsorption column can be stored at 2-8℃ for a longer period of time, and Buffer P1 with RNase A can be stably stored at 2-8℃ for 6 months.2. Before the first use, add all the RNase A solution into Buffer P1, mix well, and store it at 2-8°C. Before use, leave it at room temperature for a period of time, and then use it after recovering to room temperature.3. Anhydrous ethanol should be added to Buffer PW according to the instructions on the label of the reagent bottle before first use.4. If precipitation is found in Buffer P2, Buffer N3, or Buffer PB before use, the clarification can be restored by water bath at 37℃ for a few minutes (please do not shake Buffer P2 violently).5. Be careful not to touch Buffer P2, Buffer N3 and Buffer PB directly, and tighten the lid immediately after use.6. The amount and purity of extracted plasmid is related to the concentration of bacterial culture, strain type, plasmid size, plasmid copy number and other factors.Procedure1. Take 1-5 ml of the overnight culture and add it to a centrifuge tube (self-prepared), centrifuge for 30 seconds at 13,000 rpm (~16,200×g) to collect the bacterial precipitate, and discard the supernatant as much as possible.2. Add 250 µl of Buffer P1 to the centrifuge tube with the bacterial precipitate (please check that RNase A has been added first), mix well using a pipette or vortex shaker, and suspend the bacterial precipitate.Note: If the bacterial mass is not thoroughly mixed, it will affect the lysis effect, resulting in low extraction and purity.3. Add 250µl of Buffer P2 to the centrifuge tube and mix gently up and down 4-6 times, mixing well to lyse the organisms, at which point the solution should become clear and viscous.Note: Mix gently, do not shake vigorously to avoid interrupting the genomic DNA and causing the extracted plasmid to be mixed with genomic DNA fragments. This step should take no more than 5 minutes to avoid damage to the plasmid.4. Add 350 µl of Buffer N3 to the centrifuge tube and immediately mix gently up and down for 8-10 times, mixing well so that a white flocculent precipitate should appear. centrifuge at 13,000 rpm for 5 minutes.Note: Buffer N3 should be mixed immediately after addition to avoid localized precipitation.5. Transfer the supernatant obtained in step 4 to the Spin Columns DM that have been loaded into the collection tube, centrifuge at 13,000 rpm for 30 seconds, pour off the waste liquid from the collection tube, and place the column back into the collection tube.6. Add 150 µl Buffer PB to the adsorption column and centrifuge at 13,000 rpm for 30 seconds.7. Add 400 µl Buffer PW to the adsorption column (please check that anhydrous ethanol has been added first), centrifuge at 13,000 rpm for 1 minute, and pour off the waste liquid in the collection tube.8. Place the adsorbent column in a new centrifuge tube (supplied), add 50-100 µl Buffer EB to the middle of the adsorbent membrane, leave it at room temperature for 2 minutes, centrifuge at 13,000 rpm for 1 minute, and collect the plasmid solution into the centrifuge tube. -The plasmid solution was collected into the centrifuge tube.Note: 1) To increase the recovery efficiency of the plasmid, the resulting solution can be reintroduced into the adsorbent column, left at room temperature for 2 minutes, centrifuged at 13,000 rpm for 1 minute, and the plasmid solution collected into a centrifuge tube.2) For low plasmid copy number or >10 kb, Buffer EB is preheated at 65-70°C in a water bath to increase extraction efficiency... Read More |