| Description | Inquire | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | N665925 Component 1 mL 5 mL Storage N665925A 2×SYBR qPCR Master Mix 1 1 mL 5 mL -20℃. Avoid freeze/ Thaw cycle. N665925B qPCR Primer Mix 1 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925C DNA Standard I 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925 Component 1 mL 5 mL Storage N665925A 2×SYBR qPCR Master Mix 1 1 mL 5 mL -20℃. Avoid freeze/ Thaw cycle. N665925B qPCR Primer Mix 1 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925C DNA Standard I 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925D DNA Standard II 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925E DNA Standard III 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925F DNA Standard IV 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925G DNA Standard V 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis product is a real-time fluorescence quantitative PCR of the products after NGS library construction using a dye method (SYBR Green I).(qPCR). The kit provides the reaction mixes, DNA primer mixtures, standards and sample dilutions required for the qPCR process, making the reagent system complete and easy to use. The fluorescent dye SYBR Green I contained in the reaction mixture can bind to all double-stranded DNA; the GoldStar Taq DNA Polymerase used is a chemically modified new high-efficiency hot-start polymerase, and the activation of the enzyme needs to be incubated at 95℃ for 10 minutes. the product has high specificity, high amplification efficiency, and is able to quickly and accurately quantify the concentration of the constructed libraries. The product is highly specific and efficient in amplification, and can quickly and accurately quantify the concentration of the constructed library.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.Note: High Rox and Low Rox are formulated as described in Use 2.Scope of applicationThis product is designed for absolute quantification of the concentration of Ion torrent platform second generation sequencing libraries. The end of the library contains Ion torrent P5 and P7 microarray binding sequences, the length of which does not exceed 1kb, and the concentration is not less than 0.005pM can be used to perform quantitative experiments with this product. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-CCA TCT CAT CCC TGC GTG TC - 3' Primer 2: 5'-CCT CTC TAT GGG CAG TCG GTG AT-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.Usage1. Amplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.05-50 pM. 4°C on ice was set aside.2. qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR MasterMix10 µlqPCR Primer Mix 10.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: add 1 µl High Rox per 50 µl of reaction system;Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.3. qPCR reaction program1) Please use 60-64℃ as a reference for setting range of annealing temperature, and increase the annealing temperature when non-specific reaction occurs.2) If the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.data analysis1. Standard curve productionThe standard curve was plotted using Ct values in the valid range. The standard curve correlation coefficient R2 should not be less than 0.99 and the slope should lie between -3.1 and -3.6. If the standard curve parameters are not reasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard I50 pMDNA Standard II5 pMDNA Standard III0.5 pMDNA Standard IV0.05 pMDNA Standard V0.005 pM2. Library concentration calculationThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attention1. Before testing, these instructions should be read in detail. It should be operated by personnel with professional experience or qualified by training.2. For use, please mix gently by turning up and down, avoid foaming as much as possible, and use it after centrifugation for a short period of time.3. Avoid repeated freezing and thawing of the product, repeated freezing and thawing may degrade the performance of the product.4. When preparing the reaction solution, please use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More | Product contentU665751Component100 TStorageU665751A2×UltraSYBR One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751BUltraSYBR One Step EnzymeMix50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751C50×High ROX50 µL-20℃. AvoidProduct contentU665751Component100 TStorageU665751A2×UltraSYBR One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751BUltraSYBR One Step EnzymeMix50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751C50×High ROX50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751DRNase-Free Water1.5 mL-20℃. Avoid freeze/ Thaw cycle. Product Introduction This product is a specialized kit for one-step Real-Time RT-qPCR. The SYBR Green I fluorescent dye contained can bind to all double-stranded DNA, allowing this product to be used for the detection of many different target sequences without the need to synthesize specific labeling probes. Real Time RT-qPCR reaction using this product, reverse transcription and quantitative PCR are carried out in the same reaction system, there is no need to add reagents during the reaction, no need to open the cap of the tube, avoiding contamination while improving the efficiency of the experiment. The new high-efficiency reverse transcriptase RNase H is activity-deficient, which reduces the degradation of RNA in the reverse transcription reaction. The enzyme has high reverse transcription efficiency and can perform a good reverse transcription reaction on a small amount of RNA template. It has high affinity to RNA and can read through RNA templates with high GC content and complex secondary structure. New efficient hot start enzyme, the enzyme activity is closed at room temperature, thus effectively avoiding non-specific amplification caused by non-specific binding of primers and templates or primer dimerization at room temperature, which greatly improves the accuracy of fluorescence quantitative PCR reaction. The included buffer system maximizes the efficacy of both enzymes at the same time and improves efficiency. This product has high sensitivity, high specificity, wide linear range, and more accurate quantification of target genes.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used with Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument. Instruments that do not require ROX calibration (U665567) Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others. Instruments that require High ROX calibration (U665751) ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1. Before using the reagents in this kit, please mix them gently by turning them up and down to avoid foaming as much as possible, and use them after brief centrifugation.2. This product uses RNA as the template for one-step RT-PCR experiment, RNase contamination should be avoided during operation, it is recommended to operate RNA in a special area, use special instruments and consumables, the operator with a mask and disposable gloves and often change the gloves, the experiment-related consumables should be processed with 0.1% DEPC (diethyl ether of pyrocarbonate) aqueous solution at 37℃ for 12 hours and autoclaved for 30 minutes before use. Sterilize for 30 minutes before use.3. UltraSYBR One Step RT-qPCR Buffer contains SYBR Green I fluorescent dye. Avoid bright light when storing this product or preparing PCR reaction solutions.4. Repeated freezing and thawing of each reagent in this kit should be avoided; repeated freezing and thawing may degrade the product performance. This product can be stored for a long time at -20℃, protected from light. If frequent use is required in the short term, it can be stored at 2-8℃.5. This kit must use specific primers, the choice of primers can be selected according to specific experiments, the good or bad primer design directly affects the results of RT-PCR reaction, the design of primers need to consider the GC content, primer length, primer position, the secondary structure of the PCR product and other factors, it is recommended to use a professional primer design software for design.6. This product cannot be used for fluorescent quantitative PCR by the probe method.Usage1. Dissolve RNA template, primers, 2× UltraSYBR One Step Buffer, UltraSYBR One Step EnzymeMix and RNase-Free Water and set aside on ice.2. PCR reaction system:Reagents25 µl Reaction systemFinal concentration2×UltraSYBR One Step Buffer12.5 µl1×Forward Primer,10 µM0.5 µl0.2 µM¹⁾Reverse Primer,10 µM0.5 µl0.2 µM¹⁾UltraSYBR One Step EnzymeMix0.5 µl RNA TemplateX µl10 pg – 100 ng50×Low ROX or High ROX(optional)2)0.5 µl1×RNase-Free Waterup to 25 µlNote: 1) Usually, the primer concentration of 0.2µM can get better results, and the final concentration of 0.1-0.5µM can be used as a reference for setting the range. If the amplification efficiency is not high, the concentration of primer can be increased; when non-specific reaction occurs, the concentration of primer can be decreased, thus optimizing the reaction system.(2) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.3. Vortex and shake to mix, centrifuge briefly, and collect the solution at the bottom of the tube.4. RT-qPCR reaction conditions (fluorescence quantitative PCR is a two-step method), this program is based on the ABI 7500 fluorescence quantitative PCR instrument as an exampleNote: 1) It is recommended to use two-step PCR reaction program, if you improve the reaction specificity, you can increase the annealing temperature to 60-64 ℃ as a reference for the setting range; if you do not get good experimental results due to the use of primers with lower Tm values, etc., you can try to carry out three-step PCR amplification.(2) For melting curve analysis, please set up the program recommended by the fluorescence quantitative PCR instrument used, and this program is set up with the ABI 7500 fluorescence quantitative PCR instrument as a reference.RT-qPCR reaction conditions (fluorescence quantitative PCR was a three-step method):Note: 1) For three-step PCR amplification, please use the range of 56℃-64℃ as the setting reference for the annealing temperature.(2) For melting curve analysis, please set up the program recommended by the fluorescence quantitative PCR instrument you are using, this program is ABI750 fluorescent quantitative PCR instrument as a reference setting... Read More |