| Description | Inquire | Format:2-ComponentEnzyme:Horseradish peroxidase | N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917D DNA Standard B 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917E DNA Standard C 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917F DNA Standard D 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917G DNA Standard E 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis is a dye-based (SYBR Green I) qPCR NGS library quantification kit for cfDNA, which provides the reaction mixture, DNA primer mixture, standards, and sample dilutions required for the qPCR process, making it a complete reagent system that is easy and convenient to use. The fluorescent dye SYBR Green I contained in the reaction mixture binds to all double-stranded DNA. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, the length of the standard in the kit (about 270bp) is comparable to the average length of the cfDNA NGS libraries (250-300bp), which is able to quickly and accurately quantitate the concentration of the constructed cfDNA libraries. quantification.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.NOTE: High Rox and Low Rox are formulated as described in Method of Use 2.Applicable scopeThis product is designed for the absolute quantification of the concentration of Illumina platform second generation sequencing libraries. The end of the library contains Illumina P5 and P7 microarray binding sequences, the length of which does not exceed 1kb, and the concentration is not less than 0.02pM can be used for quantitative experiments. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-60 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR MasterMix10 µlqPCR Primer Mix0.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: 1 µl High Rox per 50 µl of reaction system; Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.3.qPCR reaction programIf the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.Refer to the specific instrument setup program for dissolution curves.data analysisStandard curve productionThe standard curve was plotted according to the data processing Excel sheet. The correlation coefficient R2 of the standard curve should be not less than 0.99, and the slope should be located between -3.1 and -3.6 when the Ct value is the longitudinal coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard A60 pMDNA Standard B6 pMDNA Standard C0.6 pMDNA Standard D0.06 pMDNA Standard E0.006 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More | This kit is used to extract and purify high-quality total RNA from various plants, and is also suitable for the extraction of fungal hyphal RNA. A unique Shredder separation column is used for homogenization and filtration of high viscosity plant or fungal lysates, while silica based membrane is This kit is used to extract and purify high-quality total RNA from various plants, and is also suitable for the extraction of fungal hyphal RNA. A unique Shredder separation column is used for homogenization and filtration of high viscosity plant or fungal lysates, while silica based membrane is used to adsorb RNA for purification, effectively removing various pollutants such as polysaccharides through washing. The washed RNA can be directly used in various downstream experiments. RNA with a molecular weight greater than 200 bases was extracted using this reagent kit, with high purity and almost no DNA residue. If it is an RNA experiment that is very sensitive to trace amounts of DNA, the remaining DNA can be digested and removed on a column using DNase I without RNase. The extracted RNA can be used for experiments such as Northern Blot, Dot Blot, RT-PCR, and in vitro translation. R665489Component50 TStorageR665489ABuffer RL35 mLRTR665489BBuffer RLC35 mLRTR665489CBuffer RW140 mLRTR665489DBuffer RW2 (concentrate)11 mLRTR665489ERNase-Free Water10 mLRTR665489FSpin Columns FL with Collection Tubes50 setsRTR665489GSpin Columns RM with Collection Tubes50 setsRTR665489HRNase-Free Centrifuge Tubes (1.5 mL)50 EART Self prepared reagents:β- Mercaptoethanol, anhydrous ethanol (newly opened or dedicated for RNA extraction).Preparation and important precautions before the experiment:To prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The extracted samples should avoid repeated freeze-thaw cycles, otherwise it will affect the quantity and quality of RNA extraction.3. Please add Buffer RL before use β- Mercaptoethanol, with a final concentration of 1%. Add 10 to 1 ml Buffer RL µ L β Mercaptoethanol. join β- The buffer RL room temperature of mercaptoethanol can be stored for one month. No need to add buffer RLC when using it β- Mercaptoethanol.Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. If precipitation occurs in Buffer RL and Buffer RLC, please heat them to dissolve and place them at room temperature.6. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.7. If downstream experiments are highly sensitive to DNA, it is recommended to treat RNA with DNase I without RNase.Operation steps:1. Take 50-100 mg of fresh plant tissue, add liquid nitrogen and quickly grind it into powder.2. Collect the ground powder into a centrifuge tube (provided by oneself) and add 600 µ L Buffer RL (check if it is added before use) β- Sulfhydryl ethanol or Buffer RLC, vortex oscillation causes it to fully decompose.Attention:1) The main component of Buffer RL is guanidine isothiocyanate, which is suitable for the lysis of most plant tissues. However, in some plant tissues (such as corn endosperm), due to the unique secondary metabolites, guanidine isothiocyanate causes precipitation in the sample, resulting in poor RNA extraction efficiency. In this case, Buffer RLC can be added instead of Buffer RL.2) Incubating at 56 ℃ for 1-3 minutes helps with tissue lysis, but plants with high starch content should not be subjected to high-temperature incubation.3. Transfer all the liquid obtained in step 2 to the spin columns FL that have been loaded into the collection tube, centrifuge at 12000 rpm (~13400 × g) for 2 minutes, and transfer the supernatant from the collection tube to a new centrifuge tube (provided by oneself).Attention:1) When aspirating liquid, the tip of the gun can be cut off for easy sampling.2) Spin Columns FL can remove most of the fragments, but there will still be a small amount flowing out. After centrifugation, precipitation will form in the collection tube. When proceeding to the next step, be careful not to absorb the sediment.4. Add 0.5 times the volume of anhydrous ethanol to the clean cracking solution obtained in step 3 and quickly mix well. Attention: Adding ethanol may cause precipitation, but it does not affect subsequent experiments.5. Add all the solutions obtained in step 4 to the spin columns RM that have been loaded into the collection tube. If it is not possible to add all the solutions to the adsorption column at once, please transfer them in two separate steps. Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.6. Add 700 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube. Optional steps: If conducting RNA experiments that are highly sensitive to trace amounts of DNA, replace step 6 with the following steps.1) Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 15 seconds, discard the waste liquid, and place the adsorption column back into the recovery manifold.2) Preparation of DNase I mixture: Take 52 µ Add 8 RNase Free Water to it µ 10 x Reaction Buffer and 20 µ DNase I (1 U/ µ l) Mix well and prepare to a final volume of 80 µ The reaction solution of L.Attention:The above system is configured according to our company's DNase I reaction system. Please refer to the corresponding instructions for other company products.3) Add 80 µ l of DNase I reaction solution directly to the adsorption column and incubate at 20-30 ℃ for 15 minutes.4) Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 15 seconds, discard the waste liquid, and place the adsorption column back into the recovery manifold.7. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 15 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.8. Repeat step 7.Centrifuge at 9.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly dry the anhydrous ethanol in the column.Attention:The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).10. Place the adsorption column in a new RNase free centrifuge tube, and add 30-50 to the middle of the adsorption column in the air µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 10 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 10... Read More | R669988 Component 50T Storage R669988A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. R669988B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. R669988C Buffer RL 35 mL RT R669988D Buffer RLC 35 mL RT R669988E Buffer RW1 40 mL RT R669988F Buffer RW2 (concentrate) 11 mL R669988 Component 50T Storage R669988A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. R669988B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. R669988C Buffer RL 35 mL RT R669988D Buffer RLC 35 mL RT R669988E Buffer RW1 40 mL RT R669988F Buffer RW2 (concentrate) 11 mL RT R669988G RNase-Free Water 10 mL RT R669988H Spin Columns FL with Collection Tubes 50 sets RT R669988I Spin Columns RM with Collection Tubes 50 sets RT R669988J RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RTProductsThis kit is used for the extraction and purification of high-quality total RNA from a variety of plants, and is also suitable for the extraction of fungal mycelial RNA. The unique separation column is used for homogenization and filtration of high viscosity plant or fungal lysates, while the silicon matrix membrane is used to adsorb the RNA for purification, so that various contaminants, such as polysaccharides, are effectively removed by washing, and the eluted RNA can be directly used in various downstream experiments. The molecular weight of RNA extracted by this kit is more than 200 bases, with high purity and almost no DNA residue. For RNA experiments that are very sensitive to trace DNA, the residual DNA can be removed by digestion on a column using RNase-free DNase. The extracted RNA can be used in Northern Blot, Dot Blot, RT-PCR and in vitro translation experiments.Self-contained reagents: β-mercaptoethanol, anhydrous ethanol (freshly opened or for RNA extraction).Pre-experiment Preparation and Important Notes1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination.2) RNase-free water should be used to prepare the solution.(3) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.2. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination.(2) Glassware should be dry-roasted at 180°C for 4 hours before use, and plasticware can be soaked in 0.5M NaOH for 10 minutes, rinsed thoroughly with water and autoclaved.3) RNase-free water should be used to prepare the solution.(4) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.3. Avoid repeated freezing and thawing of the extracted samples, otherwise it will affect the amount and quality of RNA extraction.4. Please add β-mercaptoethanol to Buffer RL before use, add 10µl of β-mercaptoethanol to 1ml of Buffer RL, it can be stored for 1 month at room temperature. Buffer RL with β-mercaptoethanol can be stored at room temperature for 1 month. β-mercaptoethanol is not required for use of Buffer RLC.5. Anhydrous ethanol should be added to Buffer RW2 before first use according to the instructions on the reagent bottle label.6. If precipitation occurs in Buffer RL and Buffer RLC, heat to dissolve and leave at room temperature.7. All centrifugation steps are carried out at room temperature and all steps are performed quickly. Procedure1. 50-100 mg of plant tissue is quickly ground to a powder in liquid nitrogen and added to 600 µl of Buffer RL (check for addition of β-mercaptoethanol before use) or Buffer RLC. vortexing and oscillating to allow for adequate lysis.Note: 1) The main component of Buffer RL is guanidine isothiocyanate, which is suitable for lysis of most plant tissues. However, in some plant tissues (e.g. endosperm of corn), due to the special secondary metabolites, guanidine isothiocyanate causes precipitation of the sample, resulting in poor RNA extraction, in this case, Buffer RLC can be added instead of Buffer RL.2) Incubation at 56°C for 1-3 minutes helps tissue lysis, but do not incubate at high temperatures for plants with high starch content.2. Transfer all the liquid obtained in step 1 to an adsorption column (Spin Columns FL) that has been loaded into a collection tube, centrifuge at 12,000 rpm (~13,400 x g) for 2 minutes, and transfer the supernatant from the collection tube to a new centrifuge tube (supplied).Note: 1) The tip of the tip of the gun can be cut off when aspirating liquids to facilitate sampling.2) Spin Columns FL removes most of the debris, but a small portion will still flow out and a precipitate will form in the collection tube after centrifugation, so be careful to avoid aspirating the precipitate when proceeding to the next step.3. Add 0.5 times the volume of anhydrous ethanol to the clean lysate obtained in step 2 and mix rapidly.Note: Precipitation may occur upon addition of ethanol, but does not affect subsequent tests.4. Transfer the solution obtained in the previous step to the Spin Columns RM in the collection tube. If it is not possible to add all of the solution to the column at one time, centrifuge the column at 12,000 rpm for 15 seconds in two batches, discard the waste solution and put the column back into the collection tube.5. Add 350 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, discard the waste liquid and put the adsorbent column back into the collection tube.6. Preparation of DNase I mixture: Take 52µl of RNase-Free Water, add 8µl of 10×Reaction Buffer and 20µl of DNase I (1U/µl) to it, mix well, and make a final volume of 80µl of reaction solution.7. Add 80µl of DNase I mixture directly to the adsorption column and incubate at 20-30°C for 15 minutes.8. Add 350 µl of Buffer RW1 to the adsorption column, centrifuge at 12,000 rpm for 1 minute, discard the waste liquid and put the column back into the collection tube.9. Add 500 µl of Buffer RW2 to the column (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 15 seconds, and discard the waste solution.10. Repeat step 9.11. Place the adsorbent column back into the collection tube, centrifuge at 12,000 rpm for 1 minute, and allow the column to come to room temperature for a few minutes to thoroughly dry out the anhydrous ethanol in the adsorbent column.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (zymography, PCR, etc.).12. Load the adsorption column into a new centrifuge tube, add 30-50 µl of RNase-Free Water to the middle of the adsorbent membrane, leave it at room temperature for 1 minute, centrifuge at 12,000 rpm for 1 minute, and store the resulting RNA solution at -70°C to prevent degradation.Note: 1) The volume of RNase-Free Water should not be less than 30 µl, too small volume affects the recovery rate.2) If you want to increase the RNA yield, repeat step 12 with 30-50 µl of fresh RNase-Free Water.3) If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 12 repeated... Read More |