| Description | Inquire | Products contentN665989Component240 TStorageN665989AIndex N501 Primers for Illumina240 µL-20℃. Avoid freeze/ Thaw cycle.N665989BlIndex N901-N924 Primers for Illumina24×10 µL-20℃. Avoid freeze/ Thaw cycle.Note: The amount of individual primers used is 1 µl, each N7-endProducts contentN665989Component240 TStorageN665989AIndex N501 Primers for Illumina240 µL-20℃. Avoid freeze/ Thaw cycle.N665989BlIndex N901-N924 Primers for Illumina24×10 µL-20℃. Avoid freeze/ Thaw cycle.Note: The amount of individual primers used is 1 µl, each N7-end primer can perform 10 DNA library constructs, and each kit can perform 240 DNA library constructs. Products IntroductionThis kit is a companion kit to the transposase-based Rapid DNA Library Construction Kit for Illumina platform library construction. Each kit contains one N5 primer and 24 N7 primers, which can be used to prepare 24 different single-ended Index libraries. All reagents provided in the kits have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The libraries can be used for sequencing on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Kangwei Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes;Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers. ProcedureFor the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol.Index N501 Primer for IlluminaIndex N901-N996 Primer for Illumina... Read More | Product introduction:Griess reagent can be used for spectrophotometric detection of nitrite. The reagent contains two chemicals, sulfonic acid and n- (1-naphthyl) ethylenediamine. Under acidic conditions, sulfamic acid is converted into diazonium salt by nitrite, which can form a highly Product introduction:Griess reagent can be used for spectrophotometric detection of nitrite. The reagent contains two chemicals, sulfonic acid and n- (1-naphthyl) ethylenediamine. Under acidic conditions, sulfamic acid is converted into diazonium salt by nitrite, which can form a highly colored azo dye with n- (1-naphthyl) ethylenediamine. This dye can be detected at 548 nm: because no is extremely unstable, it is oxidized to form nitrite and nitrate. Griess indirectly reflects the content of no by detecting the content of nitrite.Matters needing attention:1. before using Griess reagent, return it to room temperature and check the solution for precipitation. If Griess reagent I contains sediment when taken out, it can be placed in a 37 ℃ water bath until the sediment dissolves. 2. this product is potentially harmful. Avoid prolonged or repeated exposure. Avoid entering eyes, skin or clothing. Please wear lab clothes and disposable gloves for operation.Scope of application:No detectionComponent:Instruction:1.Griess Reagent I and II were taken out to restore the room temperature.2.Standard dilution : The standard NaNO2 ( 1-100 µM ) was diluted with the solution used for the sample to be tested. The standard was diluted to 1 µM, 10 µM, 20 µM, 40 µM, 80 µM and 100 µM, and 100 µL standard was added to each well. If the sample concentration is too low, the range of the standard curve can be appropriately reduced ( 1 µM, 2 µM, 3 µM, 4 µM, 6 µM, 8 µM, 10 µM ).3.Sample detection :( 1 ) According to the total volume of 200 µL / hole, 100 µL / hole sample was added to the 96-well plate ; if the sample is the supernatant of the culture medium, it can be sampled directly, and if there is sediment, the supernatant should be taken after centrifugation. If the sample is a cell or tissue, it can be quickly lysed by freeze-thaw, and then centrifuged to obtain the supernatant. The volume of less than 100 µL can be diluted with diH2O or 0.9 % NaCl ( corresponding standards also need to be diluted with diH2O or 0.9 % NaCl ).( 2 ) According to 50 µL / hole, Griess Reagent I was added to each hole.( 3 ) According to 50 µL / hole, Griess Reagent II was added to each hole.( 4 ) The absorbance was measured at 540 nm. If there is no 540 nm filter, 520-560 nm filter can also be. If there is no microplate reader or a suitable filter, the concentration of nitric oxide in the sample can also be determined by visual colorimetry. A more precise concentration gradient is required for the standard when visual colorimetric... Read More | Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly luciferase is widely used in gene regulation and drug screening. Firefly luciferase is a protein with a molecular weight of about 61 KD. In the presence of ATP, magnesium ions and oxygen, it can catalyze the production of oxyluciferin from luciferin. In the process of luciferin oxidation, it will produce a light signal. The optical signal of this kit is a kind of instantaneous light, which needs to be detected immediately after adding the working solution. The half-life of optical signal is about 5 min.Instruction:1.Working fluid configuration ( 1 ) Restore all components to room temperature. ( 2 ) The component B ( stock solution ) was fully diluted with component A to prepare a 0.2 mg / mL firefly luciferase working solution, which was vortexed and shaken to ensure full mixing. Note : The firefly luciferase working solution cannot be repeatedly frozen and thawed. If the dosage of a single experiment is small, it is recommended to subpackage according to a single dosage. At room temperature, the activity decreased by about 10 % after the working solution was configured for 3 h, and the activity decreased by about 25 % after 5 h. 2.chemiluminescence value detection ( 1 ) The cell culture plate was taken out from the incubator and incubated at room temperature for 20 min to restore it to room temperature ( 22-25 ° C ). ( 2 ) Add the same volume of firefly luciferase working solution with the medium to the culture plate and mix well. ( 3 ) Incubation at room temperature for 5 min. Note : The incubation time can be adjusted according to cell type and cell number. ( 4 ) The values were read by multifunctional microplate reader or chemiluminescence instrument ( instrument parameters : the determination time was 10 s, the determination interval was 2 s ).Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. the strongest wavelength of bioluminescence catalyzed by firefly luciferase is 560 nm. 3. to prevent interference between holes, it is recommended to use white opaque orifice plate.Recommendation:Component B is recommended to use sterile water in advance to configure 2 mg / mL storage solution, A component and B component configured as storage solution, and small batch packaging according to the experimental requirements. The detection working fluid is recommended to be used now to avoid repeated freezing and thawing. Component:One-Step Firefly Luciferase Assay Buffer;D-Luciferin Scope of application:Mainly used for ADCC detection... Read More | Inquire |