| Description | Inquire | Inquire | Product contentP666142Component200 TStorageP666142ABuffer P160 mLRTP666142BBuffer P260 mLRTP666142CBuffer N380 mLRTP666142DBuffer PB35 mLRTP666142EBuffer PW (concentrate)25 mLRTP666142FBuffer EB30 mLRTP666142GRNase A (10 mg/mL)600 µLRTP666142HSpin Columns DM with Collection Tubes200 EART Product contentP666142Component200 TStorageP666142ABuffer P160 mLRTP666142BBuffer P260 mLRTP666142CBuffer N380 mLRTP666142DBuffer PB35 mLRTP666142EBuffer PW (concentrate)25 mLRTP666142FBuffer EB30 mLRTP666142GRNase A (10 mg/mL)600 µLRTP666142HSpin Columns DM with Collection Tubes200 EART Product IntroductionThis kit is suitable for extracting 1-5 ml of bacterial solution. Based on the lysis of cells by alkaline lysis method, it adopts a unique silica matrix membrane adsorption technology and reagent formulation, and efficiently and exclusively binds plasmid DNA in solution by centrifugal adsorption columns in a high-salt state, and each adsorption column can adsorb a maximum of 30 µg of plasmid DNA, and removes proteins, genomes, RNAs, and other impurities to the greatest extent possible. The plasmid DNA obtained can be directly used for cell transfection, PCR, digestion, sequencing, ligation and other biological experiments.Self-contained reagent: anhydrous ethanol.Pre-experiment Preparation and Important Notes1. All components can be stably stored in dry, room temperature (15-30℃) environment for 1 year, the adsorption column can be stored at 2-8℃ for a longer period of time, and Buffer P1 with RNase A can be stably stored at 2-8℃ for 6 months.2. Before the first use, add all the RNase A solution into Buffer P1, mix well, and store it at 2-8°C. Before use, leave it at room temperature for a period of time, and then use it after recovering to room temperature.3. Anhydrous ethanol should be added to Buffer PW according to the instructions on the label of the reagent bottle before first use.4. If precipitation is found in Buffer P2, Buffer N3, or Buffer PB before use, the clarification can be restored by water bath at 37℃ for a few minutes (please do not shake Buffer P2 violently).5. Be careful not to touch Buffer P2, Buffer N3 and Buffer PB directly, and tighten the lid immediately after use.6. The amount and purity of extracted plasmid is related to the concentration of bacterial culture, strain type, plasmid size, plasmid copy number and other factors.Procedure1. Take 1-5 ml of the overnight culture and add it to a centrifuge tube (self-prepared), centrifuge for 30 seconds at 13,000 rpm (~16,200×g) to collect the bacterial precipitate, and discard the supernatant as much as possible.2. Add 250 µl of Buffer P1 to the centrifuge tube with the bacterial precipitate (please check that RNase A has been added first), mix well using a pipette or vortex shaker, and suspend the bacterial precipitate.Note: If the bacterial mass is not thoroughly mixed, it will affect the lysis effect, resulting in low extraction and purity.3. Add 250µl of Buffer P2 to the centrifuge tube and mix gently up and down 4-6 times, mixing well to lyse the organisms, at which point the solution should become clear and viscous.Note: Mix gently, do not shake vigorously to avoid interrupting the genomic DNA and causing the extracted plasmid to be mixed with genomic DNA fragments. This step should take no more than 5 minutes to avoid damage to the plasmid.4. Add 350 µl of Buffer N3 to the centrifuge tube and immediately mix gently up and down for 8-10 times, mixing well so that a white flocculent precipitate should appear. centrifuge at 13,000 rpm for 5 minutes.Note: Buffer N3 should be mixed immediately after addition to avoid localized precipitation.5. Transfer the supernatant obtained in step 4 to the Spin Columns DM that have been loaded into the collection tube, centrifuge at 13,000 rpm for 30 seconds, pour off the waste liquid from the collection tube, and place the column back into the collection tube.6. Add 150 µl Buffer PB to the adsorption column and centrifuge at 13,000 rpm for 30 seconds.7. Add 400 µl Buffer PW to the adsorption column (please check that anhydrous ethanol has been added first), centrifuge at 13,000 rpm for 1 minute, and pour off the waste liquid in the collection tube.8. Place the adsorbent column in a new centrifuge tube (supplied), add 50-100 µl Buffer EB to the middle of the adsorbent membrane, leave it at room temperature for 2 minutes, centrifuge at 13,000 rpm for 1 minute, and collect the plasmid solution into the centrifuge tube. -The plasmid solution was collected into the centrifuge tube.Note: 1) To increase the recovery efficiency of the plasmid, the resulting solution can be reintroduced into the adsorbent column, left at room temperature for 2 minutes, centrifuged at 13,000 rpm for 1 minute, and the plasmid solution collected into a centrifuge tube.2) For low plasmid copy number or >10 kb, Buffer EB is preheated at 65-70°C in a water bath to increase extraction efficiency... Read More | Products R669890Component50 TStorageR669890ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669890B10×Reaction Buffer1mL-20℃. Avoid freeze/thaw cycle.R669890CBuffer RL35 mLRTR669890DBuffer RW140 mLRTR669890EBuffer RW2 (concentrate)11 mLRTR669890FRNase-Free Water10 mLRTR669890GSpin Products R669890Component50 TStorageR669890ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669890B10×Reaction Buffer1mL-20℃. Avoid freeze/thaw cycle.R669890CBuffer RL35 mLRTR669890DBuffer RW140 mLRTR669890EBuffer RW2 (concentrate)11 mLRTR669890FRNase-Free Water10 mLRTR669890GSpin Columns FL with Collection Tubes50 setsRTR669890HSpin Columns RM with Collection Tubes50 setsRTR669890IRNase-Free Centrifuge Tubes (1.5 mL)100 EART ProductsThis kit adopts centrifugal adsorption columns with high efficiency and specificbinding of nucleic acids and unique buffer system, which can rapidly extract totalRNA from bacteria or cultured animal cells.The reaction can be completed in 30-40minutes, and the extracted total RNA is extremely pure and free of protein and othercontaminants, which is suitable for RT-PCR, Real-Time RT-PCR, microarray analysis,in vitro translation and other experiments. Self-contained reagents: Lysozyme, β-mercaptoethanol, anhydrous ethanol (freshlyopened or for RNA extraction). Pre-experiment Preparation and Important Notes 1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination. 2) RNase-free water should be used to prepare the solution. 3) Operators wear disposable masks and gloves, and change gloves diligently duringthe experiment. 2. Add β-mercaptoethanol to Buffer RL before use to reach a final concentrationof 1%, e.g., add 10 µl of β-mercaptoethanol to 1 ml of Buffer RL. Buffer RL withβ-mercaptoethanol can be stored at 4℃ for 1 month, if precipitation occurs, pleaseheat to dissolve and use.3. Anhydrous ethanol should be added to Buffer RW2 before first use according tothe instructions on the reagent bottle label. 4. All centrifugation steps are carried out at room temperature if not otherwisespecified, and all steps should be performed quickly. Procedure 1. Centrifuge at 12,000 rpm (~13,400 x g) at 4°C for 2 minutes to collect theorganisms (maximum volume of organisms should not exceed 1 x 109) and carefullyremove all supernatants. Note: Supernatants that leave residues can interfere with the subsequent digestionprocess. 2. Thoroughly resuspend the organisms with 100 µl of TE buffer containing Lysozymeand incubate at room temperature. The specific formulation and incubation time areas follows:/The final concentration of Lysozyme in TE bufferincubation timeG-germ400µg/ml3-5minG+germ3mg/ml5-10min 3. Add 350 µl of Buffer RL (check that β-mercaptoethanol has been added beforeuse), vortex and shake to mix (insoluble precipitate may appear in this step), addall of the solution and the precipitate to the filter columns (Spin Columns FL) thathave been loaded into the collection tubes, and centrifuge at 12,000 rpm for 2minutes. 4. Add 250 µl of anhydrous ethanol to the filtrate obtained in the previous stepand mix well (a precipitate may appear at this point). Transfer the resulting solution together with the precipitate to a Spin Columns RM packed in a collectiontube, centrifuge at 12,000 rpm for 1 min, discard the waste solution and put thecolumn back into the collection tube.5. Add 350 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for1min, discard the waste liquid and put the adsorbent column back into the collectiontube.6. Preparation of DNase I mixture: Take 52µl of RNase-Free Water, add 8µl of 10×Reaction Buffer and 20µl of DNase I (1U/µl) to it, mix well, and make a finalvolume of 80µl of reaction solution.7. Add 80µl of DNase I mixture directly to the adsorption column and incubate at20-30°C for 15 minutes.8. Add 350 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for1min, discard the waste liquid and put the adsorbent column back into the collectiontube.9. Add 500 µl of Buffer RW2 to the column (check that anhydrous ethanol is addedbefore use), centrifuge at 12,000 rpm for 1 min, and discard the waste solution.10. Repeat step 9.11. Place the adsorbent column back into the collection tube and centrifuge at 12,000rpm for 2 minutes. Note: The purpose of this step is to remove residual ethanol from the adsorptioncolumn; ethanol residue can interfere with subsequent enzymatic reactions (zymography, PCR, etc.).12. Load the adsorption column into a new RNase-Free collection tube, add 30-50 µl of RNase-Free Water to the middle of the adsorption membrane, leave it at roomtemperature for 1 minute, centrifuge at 12,000 rpm for 1 minute, collect the RNAsolution, and store the RNA at -70°C to prevent degradation. Note: 1) The volume of RNase-Free Water should not be less than 30 µl, too smallvolume affects the recovery rate. 2) If you want to increase the RNA yield, repeat step 12 with 30-50 µl of freshRNase-Free Water. If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 12 repeated... Read More | This reagent kit uses an adsorption column that can specifically bind to viral RNA and a unique buffer system, suitable for isolating viral RNA from cell-free body fluids such as serum, plasma, urine, cerebrospinal fluid, and cell culture supernatants. The viral RNA specifically binds to the siliconThis reagent kit uses an adsorption column that can specifically bind to viral RNA and a unique buffer system, suitable for isolating viral RNA from cell-free body fluids such as serum, plasma, urine, cerebrospinal fluid, and cell culture supernatants. The viral RNA specifically binds to the silicon substrate membrane, and pollutants flow through the membrane. Completely remove impurities such as proteins through two efficient washes, and then wash high-purity viral RNA with RNase free water or RNase Free Water provided by the reagent kit. The virus RNA extracted by this kit can be directly used for experiments such as RT-PCR, Real time RT-PCR, and Western blot analysis. R666005Component50 TStorageR666005ABuffer GL15 mLRTR666005BBuffer RW140 mLRTR666005CBuffer RW2(concentrate)11 mLRTR666005DProteinase K12.5 mgRTR666005EProteinase K Storage Buffer1.25 mLRTR666005FRNase-Free Water10 mLRTR666005GSpin Columns RS with Collection Tubes50 setsRTR666005HRNase-Free Centrifuge Tubes(1.5 mL)50 EART Self prepared reagent: anhydrous ethanol, 0.9% NaCl.Preparation and important precautions before the experiment1. Add 1.25 ml of Protein K Storage Buffer to Protein K to dissolve it and store at -20 ℃. The prepared Protein K should not be left at room temperature for a long time to avoid repeated freeze-thaw cycles, which may affect its activity.2. To prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.3. Serum or plasma should avoid repeated freeze-thaw cycles that may cause protein denaturation or precipitation, reduce viral titers, and thus affect the yield of extracted viral nucleic acids.4. Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. If buffer GL precipitates, it can be heated at 56 ℃ to dissolve and then placed at room temperature.6. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Operation steps1. Take 200 at room temperature µ Add serum or plasma to a 1.5 ml centrifuge tube (self provided). Attention: Less than 200 µ 0.9% NaCl (provided by the customer) can be added to make up for it.2. Add 20 to the solution in the previous step µ Protein K, mix well.3. Add 200 µ L Buffer GL, vortex oscillation for 15 seconds. Note: Do not directly add Protein K to Buffer GL. 4. Incubate at 56 ℃ for 15 minutes, briefly centrifuge, and collect the solution on the tube wall to the bottom of the tube.5. Add 250 µ Anhydrous ethanol, vortex for 15 seconds, incubate at room temperature for 5 minutes, briefly centrifuge, and collect the solution from the tube wall to the bottom of the tube.6. Add all the solution obtained in step 5 to the Spin Columns RS that have been loaded into the collection tube. If it is not possible to add all the solution to the adsorption column at once, please transfer it in two batches, centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and put the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.8. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.9. Add 500 to the adsorption column µ Centrifuge anhydrous ethanol at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube. 10. Centrifuge at 12000 rpm for 3 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Attention:1) The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).2) Recommended steps: Place the adsorption column into a new 1.5 ml centrifuge tube (provided), open the tube cover, and incubate in a 56 ℃ oven for 3 minutes to thoroughly dry the membrane of the adsorption column.11. Place the adsorption column in a new RNase free centrifuge tube and add 20-50 to the middle of the adsorption column in the air µ Place RNase Free Water at room temperature for 5 minutes, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 20 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 20-50 µ Repeat step 11 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 11... Read More |