| Description | In the experimental process of molecular biology, Fluo ™ Green ® The dsDNA quantification kit is a product used for fluorescence detection and quantification of double stranded DNAThe method is very sensitive. Commonly used in molecular biology techniques: construction of cDNA libraries; In the experimental process of molecular biology, Fluo ™ Green ® The dsDNA quantification kit is a product used for fluorescence detection and quantification of double stranded DNAThe method is very sensitive. Commonly used in molecular biology techniques: construction of cDNA libraries; Purification and application of DNA fragments for subcloning, such as DNA quantification, product amplification, and further detection of primers. Vaccines are a commonly used control method in modern disease prevention. Nowadays, many vaccines are cell culture vaccines, such as recombinant hepatitis B vaccine, rabies vaccine and most other vaccines are produced by cell culture. Among them, the purification of vaccines is a key issue, and we need to remove host cell DNA and host proteins as much as possible. If the DNA and protein of the host cell are injected into the human body together with the vaccine, unpredictable consequences will occur.The conventional method for detecting DNA content is to measure its absorbance at 260nm (A260). The main disadvantage of this method is that nucleotides, single stranded nucleic acids, and proteins have a significant impact on the signal, and are also subject to interference from pollutants during the nucleic acid preparation process, making it difficult to distinguish between DNA and RNA. Additionally, this method is insensitive (5 µ g/mL dsDNA solution A260=0.1). Fluo ™ The Green quantitative detection method is simple and convenient, and has been selected by multiple biological product factories, becoming the standard for residual DNA detection in biological products.At present, this method has been included in the 2010 edition of the Chinese PharmacopoeiaPrinciple:Fluo ™ Green emits fluorescence only after binding to double stranded DNA, and does not emit fluorescence without DNA; The fluorescence emitted is directly proportional to the concentration of DNA. In the 2010 Chinese Pharmacopoeia, it was proposed that, Fluo ™ The detection limit of Green's quantitative DNA method is about 0.3ng/ml, and the linearity is good (R2>0.99) when the DNA content is in the range of 1.25-80ng/mLAdvantage:1) This method can determine double stranded DNA from any expressed host sample.2) It is possible to directly quantify PCR amplification products without purifying DNA from the reaction mixture.3) Far exceeding the sensitivity of traditional UV A260 detection methods and Hoechst33258.4) Higher concentrations of salt, urea, ethanol, chloroform, detergents, proteins, or agarose have no effect on the measurement.5) The effect of measuring dsDNA in the presence of equimolar concentrations of ssDNA and RNA is minimal.Required equipment• Micro fluorescence meter; Portable fluorescence analyzer - Shanghai Huguo Scientific Instrument Co., Ltd. HG-9 model; 1cm quartz colorimetric dish• Fluo ™ Green dsDNA quantitative detection kit, 1mL of concentrated reagent solution is sufficient for 200 measurements of 2mL volume.1×TE(10mM Tris 1mM EDTA)pH8.0; 250ug/mL calf thymus DNAExperimental planPreparation of reagentsFluo ™ The Green dsDNA quantification reagent is stored in anhydrous DMSO (dimethyl sulfoxide) in the form of 1mL concentrated solution. On the day of the experiment, prepare2X Fluo ™ The operating solution of Green's reagent was diluted with 1xTE at a ratio of 1:200 in concentrated solution (10mM Tris HCl,1mM EDTA, pH 7.5). If you want to prepare enough operating solution to determine 20 samples, you can add 100 µ L Fluo to 20mL1x TE ™ Green dsDNA quantification reagent. Due to the easy adsorption of reagents onto glass surfaces, they need to be prepared in plastic containers. Fluo ™ Green reagent is easily degraded by light, so the prepared solution should be wrapped in foil or stored in a dark place away from light.It is best to use the solution within a few hours of preparation to ensure optimal results.Experimental method:1). Preparation of standard working fluid:1mg of calf thymidine DNA dry powder (Tris, NaCl, and other concentrations have become standard systems) is added to 1mL of double distilled water to prepare a 1mg/mL standard working solution;2). Configuration of dye working fluid:6 uL Fluo ™ Add 1mL of TE to Green (note: use 1 × TE to mix Fluo) ™ Dilute Green 200 times, use and prepare immediately, avoid light.3). Dilution of standard working fluid:(1) Mother liquor dilution: Take 10ul (1mg ⁄ mL) of standard working solution and add it to 990ul TE solution to dilute the concentration to 10ug ⁄ mL. Take 10ul (10ug ⁄ mL) of standard working solution and add it to 990ul TE solution to dilute the concentration to 100ng ⁄ mL;(2) Dilute by multiple ratio: Take 800ul (100ng ⁄ mL) of standard working solution and add it to 200ul of TE solution to achieve a concentration of 80ng ⁄ mL (pharmacopoeia regulation: fluorescent)The light staining method shows good linearity in the range of 1.25-80 ng/mL for DNA content, with a detection limit of 0.3 ng/mL. Take 500ul (80ng ⁄ mL) of standard working solution and add it to 500ul TE solution, diluting the concentration to 40ng ⁄ mL; Dilute sequentially by multiple ratios to prepare 20ng/ml 10ng/ml 5.0ng/ml 2.5ng/ml1.25ng/ml and 0.625ng/ml standard solution;4). Preparation of standard curve: Take 100ul of each gradient standard solution and dye working solution diluted by multiple ratios, mix well, and leave them at room temperature in the dark for 5 minutes. Use FB-15 portable fluorescence analyzer to detect the fluorescence value of the sample: Add the mixed solution to the microcalorimeter, make sure not to introduce bubbles into the sample, and gently tap the outside of the microcalorimeter to disperse the bubbles. Measure the fluorescence values of the sample and blank control using 1 × TE buffer as a blank; Corresponding to the concentration of standard solution (ng/ml)Perform linear regression on fluorescence intensity and prepare a standard curve.5). Measure the fluorescence value of the remaining samples. The fluorescence meter will provide a direct concentration reading, which can be used to generate a standard curve of DNA concentration. Final concentration of DNA to be tested Fluorescence reading value (ng/ml) / 100 6210 50 3195 40 2507 20 1261 10 620.8 5 298 4 258.8 2 152 0.5 43.8 0 0.72... Read More | Glycogen and starch generate glucose-1-phosphate (1PG/G1P) during the process of phosphohydrolysis. This reagent kit provides a simple, sensitive, and rapid determination method: Glucose-1-phosphate (1PG/G1P) is reduced from NADP+to NADPH by the sequential action of phosphoglucose mutase and Glycogen and starch generate glucose-1-phosphate (1PG/G1P) during the process of phosphohydrolysis. This reagent kit provides a simple, sensitive, and rapid determination method: Glucose-1-phosphate (1PG/G1P) is reduced from NADP+to NADPH by the sequential action of phosphoglucose mutase and phosphoglucose dehydrogenase. The content of glucose-1-phosphate (1PG/G1P) in the sample can be calculated by detecting the increase in NADPH at 340nm.Composition and preparation of reagent kit: Reagent name Specifications Save requirements Remarks Extraction solution Liquid 100mL x 1 bottle 4 ℃ storage / Reagent 1 Powder mg x 1 tube 4 ℃ storage Shake or centrifuge the reagent a few times before use to make it fall to the bottom, then dissolve it in 1.2mL of distilled water for later use. Reagent 2 Powder mg x 1 tube Store at -20 ℃ Shake or centrifuge the reagent a few times before use to make it fall to the bottom, then dissolve it in 1.2mL of distilled water for later use. Reagent 3 Liquid 16mL x 1 bottle 4 ℃ storage / Reagent 4 Powder mg x 1 tube Store at -20 ℃ Shake or centrifuge the reagent a few times before use to make it fall to the bottom, then add 1 Dissolve 1mL of distilled water for later use. TRC 1 powder 4 ℃ storage Only used to identify whether the reagents in the kit are normal (not involved in result calculation). Usage: Use a pre standard tube (GIP) to shake the powder a few times until it falls to the bottom, then add 0.5mL of distilled water and mix well to dissolveDilute GIP with a concentration of 4mg/mL and then dilute it four times to 1mg/mL for later use: follow the instructions in the sample addition table for the measuring tube operationRequired instruments and supplies:ELISA reader, 96 well plate, desktop centrifuge, adjustable pipette, mortar, ice and distilled water.Determination of glucose-1-phosphate (1PG/G1P) content:1. Sample preparation① Organizational sample:Suggest weighing around 0 1g of tissue, add 1mL of extraction solution, and homogenize in an ice bath. Centrifuge at 12000rpm, 4 ℃ for 10 minutes, take the supernatant, and place it on ice for testing.[Note]: If the sample size is increased, it can be extracted in a ratio of tissue mass (g) to extraction solution volume (mL) of 1:5-10.② Bacterial/cellular samples:Collect bacteria or cells into a centrifuge tube first, centrifuge and discard the supernatant; Take about 5 million bacteria or cells and add them to 1mLExtract solution, sonicate bacteria or cells (ice bath, power 200W, sonication for 3s, interval 10s, repeated 30 times); Centrifuge at 12000rpm at 4 ℃ for 10 minutes, take the supernatant, and place it on ice for testing.[Note]: If the sample size is increased, extraction can be carried out in a ratio of 500-1000:1 of bacteria/cell quantity (104) to extraction solution (mL).③ Liquid sample: direct detection.2. Machine testing:① Preheat the enzyme-linked immunosorbent assay (ELISA) reader for at least 30 minutes and adjust the wavelength to 340nm.② Thaw the reagent to room temperature (25 ℃);③ Add reagents to the 96 well plate in the following order according to the table:② Thaw the reagent to room temperature (25 ℃);③ Add reagents to the 96 well plate in the following order according to the table: Reagent name (µL) Measurement tube Blank tube (only done once) Reagent 1 10 10 Reagent 2 10 10 Reagent 3 150 170 Sample 20 / Mix well, incubate at room temperature (25 ℃) for 20 minutes, and then read A1 at 340nm (if the A value continues to increase, the incubation time needs to be extended until the absorbance value remains unchanged within 2 minutes). Reagent 4 10 10 Mix well, incubate at room temperature (25 ℃) for 20 minutes, and then read A2 at 340nm (if the A value continues to increase, the incubation time needs to be extended until the absorbance value remains unchanged within 2 minutes). Δ A=(A2-A1) measurement - (A2-A1) blank.[Note] 1 If the difference in Δ A is hovering around zero, the sample size V1 can be increased (such as increasing to 50 µ L, the three phases of the reagent should be reduced while keeping the total volume unchanged), or the sample sampling mass W can be increased. The changed V1 and W need to be substituted into the formula for recalculation.If the A2 value exceeds 1.2, the amount of sample added V1 can be reduced (such as to 10 µ L, the three-phase reagent should be increased while keeping the total volume unchanged), or the sample can be diluted with distilled water (keeping the sample addition system unchanged), and the changed V1 and D need to be substituted into the formula for recalculation.Result calculation:1. Calculated by sample weight:1PG/G1P content (µ g/g fresh weight)=[(Δ A ÷ (ε× d) × V2 × 106 × MR] ÷ (W × V1 ÷ V) × D=836 × Δ A ÷ W × D2. Calculated by the number of cells:1PG/G1P content (µ g/104 cell)=[(Δ A ÷ (ε× d) × V2 × 106 × MR] ÷ (500 × V1 ÷ V) × D=1.7 × Δ A × D. 3. Calculated by liquid volume:1PG/G1P content (µ g/mL)=[(Δ A ÷ (ε× d) × V2 × 106 × Mr] ÷ V1=836 × Δ A ε---NADPH Molar extinction coefficient,6.22×103 L/mol/cm; d---96 Orifice plate optical diameter,0.5cm; V---Add volume of extraction solution,1 mL; V1---Add sample volume,0.02mL V2---Total reaction volume;0.2mL=2×10-4L; W---Sample quality,g; Mr---Glucose-1-phosphate(1PG/G1P)Molecular weight;260; 500---Number of cells, in millions; D---Dilution ratio,Undiluted is 1。 /... Read More | Products contentNote: The amount of individual primers used is 1 µl, each N7-end primer can perform 10 DNA library constructs, and each kit can perform 240 DNA library constructs.Products IntroductionThis kit is a companion kit to the transposase-based Rapid DNA Library Construction Kit for Products contentNote: The amount of individual primers used is 1 µl, each N7-end primer can perform 10 DNA library constructs, and each kit can perform 240 DNA library constructs.Products IntroductionThis kit is a companion kit to the transposase-based Rapid DNA Library Construction Kit for Illumina platform library construction. Each kit contains one N5 primer and 24 N7 primers, which can be used to prepare 24 different single-ended Index libraries. All reagents provided in the kits have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The libraries can be used for sequencing on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Kangwei Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes; Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers. procedureFor the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol. Index N501 Primer for Illumina Index N901-N996 Primer for Illumina... Read More | Product content: S665546Component50 TStorageS665546ABuffer QSL45 mLRTS665546BBuffer RIL11 mL2-8℃S665546CBuffer ML10 mLRTS665546DBuffer GW1 (concentrate)13 mLRTS665546EBuffer GW2 (concentrate)26 mLRTS665546FBuffer EBL13 mLRTS665546GRNase A240 µLRTS665546HLysis Tubes Ⅱ50 Product content: S665546Component50 TStorageS665546ABuffer QSL45 mLRTS665546BBuffer RIL11 mL2-8℃S665546CBuffer ML10 mLRTS665546DBuffer GW1 (concentrate)13 mLRTS665546EBuffer GW2 (concentrate)26 mLRTS665546FBuffer EBL13 mLRTS665546GRNase A240 µLRTS665546HLysis Tubes Ⅱ50 EARTS665546ISpin Columns DM With Collection Tubes50 EARTProduct IntroductionThis kit provides a method for extracting total DNA from soil or fecal samples, including the total DNA of cells, bacteria, parasites, and viruses in the samples. It is also suitable for extracting DNA from samples containing high concentrations of PCR reaction inhibitors. This reagent kit adopts a unique buffering system to efficiently bind DNA from the lysis solution to the adsorption column. Inhibitors of PCR and enzyme reactions, as well as residual impurities, can be effectively removed through washing steps. Finally, high-purity DNA can be obtained by washing with low salt buffer or water. The purified DNA can be directly used for downstream experiments such as second-generation sequencing (16S amplicons and metagenomes), library construction, PCR, qPCR, Southern Blot, enzyme digestion molecular markers, etc.Self prepared reagents1. Constant temperature mixer - Product number: CW25932. Anhydrous ethanol, isopropanol3. Vortex oscillator or tissue grinderPreparation and important precautions before the experiment1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.Before the first use, anhydrous ethanol should be added to Buffer GW1 (concentrate) and Buffer GW2 (concentrate) according to the instructions on the reagent bottle label.3. Take out the buffer RIL before use and store it at 2-8 ℃ immediately after use.Operation steps1. Centrifuge the Lysis Tube briefly to allow the beads to settle at the bottom.2. a. Add 0.1-0.3 g of soil or fecal sample to Lysis Tube, and add 740-820 µ L Buffer QSL and 4 µ L RNase A, tighten the tube cover and briefly vortex to mix.b. If fecal samples are stored in non lytic fecal preservation solutions (such as CWY041S and CWY041M), add 200 to Lysis Tube µ L-600 µ L solid-liquid mixture, centrifuge at 13000 rpm for 1 minute, discard the storage solution (if the amount of solid after centrifugation is too small, it can be enriched again, but should not exceed 0.3g). Join 620 µ LBuffer QSL and 4 µ L RNase A, tighten the tube cover and briefly vortex to mix.3. Fix the Lysis Tube in an oscillating grinding device equipped with a 2 mL adapter and process it according to the optimized grinding conditions of your equipment (see appendix).4. Shake the Lysis Tube on a constant temperature mixer at 70 ℃ and 1200 rpm for 10 minutes. Subsequently, centrifuge at 13000 rpm for 2 minutes to precipitate solid particles. Transfer 540 µ Transfer the supernatant to a new 2 mL centrifuge tube.5. Add 180 µ L Buffer RIL, vortex for 5 seconds, centrifuge at 13000 rpm for 2 minutes.Attention: Remove the buffer RIL before use and store it at 2-8 ℃ immediately after use.6. Add 160 to the new centrifuge tube in sequence µ L Buffer ML, 480 µ Supernatant from step 5, 320 µ L isopropanol, vortex for 5 seconds.7. Transfer the solution from the previous step to 650 µ Centrifuge at 12000 rpm (~13400 × g) for 1 minute into the spin columns DM that have been loaded into the collection tube.8. Discard the waste liquid in the collection pipe and place the adsorption column back into the collection pipe. Repeat step 7 until all the solution has been transferred.9. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.10. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. 11. Repeat step 10.12.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).13. Place the adsorption column in a new centrifuge tube (self provided) and add 50-200 drops of suspended droplets to the middle of the adsorption column µ L Buffer EBL or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Note: 1) Incubating at room temperature for 5 minutes before centrifugation can increase yield.2) Use an additional 50-100 µ Further elution with L buffer or sterilized water can increase yield.3) If you want to increase the final concentration of DNA, you can add the DNA eluent obtained in step 13 back onto the adsorption membrane and repeat step 13, but it may reduce the total yield.4) The elution buffer does not contain chelating agents, please store DNA at -20 ℃.5) The residual trace PCR inhibitors in the genomic DNA template may have adverse effects on the PCR reaction, which can usually be resolved by diluting the DNA by 2-10 times.Appendix: Grind the sample using one of the following methods1. Manually vortex oscillate at maximum speed on the vortex oscillator for 10 minutes.2. On a vortex oscillator equipped with a 1.5-2 mL horizontal centrifuge tube holder, oscillate at maximum speed for 10 minutes (keeping the Lysis Tube horizontal). If the sample size exceeds 12, extend by 5-10 minutes. For example, using Scientific Industries or Mobile's Vortex Genie2 vortex oscillator.3.When using Qiagen's TissueLyser II, grind at 25Hz for 10 minutes.4.When using Qiagen's PowerLyzer 24 Homogenizer, homogenize at 2000 rpm for 30 seconds, pause for 30 seconds, and then homogenize again at 2000 rpm for 30 seconds.5.When using FastPrep-24 from MP Biomedicals, the recommended speed is 6.0 and the time is 40 seconds... Read More | Cell viability and cytotoxicity assays are usually used for drug screening and compound cytotoxicity testing. The CCK-8 kit uses highly water-soluble tetrazolium salt ( called WST-8 ) to produce water-soluble WST-8 for cell proliferation and cytotoxicity assays. Unlike MTT, WST-8 and WST-8 have no Cell viability and cytotoxicity assays are usually used for drug screening and compound cytotoxicity testing. The CCK-8 kit uses highly water-soluble tetrazolium salt ( called WST-8 ) to produce water-soluble WST-8 for cell proliferation and cytotoxicity assays. Unlike MTT, WST-8 and WST-8 have no cytotoxicity in cell culture medium, so multiple downstream experiments can be performed using the same detection plate. CCK-8 method is a convenient colorimetric method for the determination of cell viability. It does not need the solubilization process and only needs the least steps to provide the results. The CCK-8 method can be used for the determination of 96-well microplates and high-throughput screening of 384-well microplates. Advantage:At present, the commercially available liquid CCK-8 kits generally have defects such as harsh storage conditions ( -4C or -20 ), unstable use in different pH ranges, and easy deterioration ( discoloration or precipitation ). The solid instant CCK-8 kit adopts a new formula and Swiss process, which overcomes these shortcomings of the liquid CCK-8 kit. It can be stored at room temperature for a long time ( > 3 years ), ready to use, stable in a wide pH range, and the experimental results are more reliable. Compared with the liquid CCK-8 kit, the solid-soluble CCK-8 kit has higher sensitivity and the biological response time is shortened by half.Application scope:It can be used for drug screening, cell proliferation assay, cytotoxicity assay, tumor drug sensitivity test and activity detection of biological factors. Operating instructions:This reagent kit can be used for drug screening, cell proliferation assay, cytotoxicity assay, tumor drug sensitivity assay, and activity detection of biological factors.1. Carefully and slowly tear along the gap in the packaging bag;2. Pour all the powder in the bag into a clean container containing 10mL of ultrapure water, shake continuously for 1 minute, and use it when the solid is completely dissolved;3. Unused reagents must be stored at low temperatures below 4 ℃.Equipment required for testing:Enzyme reader 96 well plate with 450-490 nm filter;Carbon dioxide incubator;96 well plate, sterilized transparent plate for cell detection;Multi channel pipette (8 or 12 channels: 10-100 µ l);Blood cell counter or cell counter.Cell viability testing:1. Inoculate cell suspension (100 µ l/well) into a 96 well plate and pre culture the plate in a carbon dioxide incubator for 24 hours (37 ℃, 5% CO2);2. Add 10 µ l of CCK-8 solution to each well (be careful not to generate bubbles in the well as it may affect the reading of OD value);3. Incubate the culture plate in the incubator for 1-4 hours;4. Measure the absorbance at 450 nm using an enzyme-linked immunosorbent assay (ELISA) reader;5. If the OD value is not determined temporarily, 10 µ l of 0.1M HCI solution or 1% w/v SDS solution can be added to each well, and the culture plate can be covered and stored in the dark at room temperature. Within 24 hours of measurement, the absorbance will not change.Cell proliferation toxicity testing:1. Inoculate cell suspension (100 µ l/well) into a 96 well plate and pre culture the plate in an incubator for 24 hours (37 ℃, 5% CO2);2. Add 10ul of different concentrations of the substance to be tested to the culture plate;3. Incubate the culture plate in the incubator for an appropriate period of time (e.g. 6, 12, 24, or 48 hours);4. Add 10 µ l of CCK-8 solution to each well (be careful not to generate bubbles in the well as they may affect the reading of the OD value);5. Incubate the culture plate in the incubator for 1-4 hours;6. Measure the absorbance at 450nm using an enzyme-linked immunosorbent assay (ELISA) reader;7. If the OD value is not determined temporarily, 10 µ l of 0.1M HCI solution or 1% w/v SDS solution can be added to each well, and the culture plate can be covered and stored in the dark at room temperature. Within 24 hours of measurement, the absorbance will not change.Calculation method for cell survival rate/inhibition rate:Cell survival rate=[As Ab)/(Ac Ab)] x 100%Inhibition rate=[(Ac As)/(Ac Ab)] x 100%As: absorbance of experimental wells (including cells, culture medium, CCK-8 solution, and drug solution);Ac: absorbance of control wells (including cells, culture medium, CCK-8 solution, without drugs);Ab: Blank well absorbance (including culture medium and CCK-8 solution, excluding cells and drugs).Points for attention: 1.Unused reagents must be stored at low temperature below 4 °C, and stored in the dark at-20 °C for two years after unpacking, so as to avoid repeated thawing ; 2.The culture time of CCK-8 is generally 1-4 hours, but the naked eye can be taken out to observe the color degree in about 30 minutes. According to the cell type, the conditions need to be explored. The best reaction time of CCK-8 is based on the best time of specific color development.3. It is recommended to do a few holes to explore the number of inoculated cells and the culture time after adding CCK-8 reagent ; 3.The WST-8 in this kit will react with reducing agents ( such as some antioxidants ) to interfere with the detection. Before the cell proliferation-toxicity test, the background OD can be checked to confirm whether there is a reducing agent in the substance to be tested. If the effect of reducing agent needs to be removed, the fresh medium can be replaced before adding CCK-8 ( remove the medium, wash the cells twice with the medium, and then add the new medium ) ; 4.Phenol red in the medium does not affect the experimental results, and the absorbance of phenol red can be eliminated by deducting the absorbance of the background in the blank hole during calculation, so it will not affect the detection. 5.It is recommended to use a multi-channel pipette to reduce the difference between parallel holes. When adding CCK-8 reagent, it is recommended to add it obliquely to the wall of the culture plate, not to insert it under the liquid surface of the medium, which is easy to produce bubbles and interfere with OD determination. 6.If the drug contains metal, it has an effect on the color of CCK-8. The final concentration of 1mM lead chloride, ferric chloride and copper sulfate will inhibit the color reaction of 5 %, 15 % and 90 %, and reduce the sensitivity. If the final concentration is 10mM, the color reaction will be 100 % inhibited ; 7.When using a 96-well plate for detection, if the cell culture time is long, attention should be paid to the evaporation problem. On the one hand, because a circle around the 96-well plate is the easiest to evaporate, the method of discarding the surrounding circle can be adopted, and the same amount of PBS, water or culture medium can be added. On the other hand, the 96-well plate can be placed near the water source in the incubator to alleviate evaporation ; 8.When using standard 96-well plates, the minimum inoculation amount of adherent cells is at least 1,000 cells / well ( 100µl medium ). The sensitivity of detecting white blood cells is relatively low, so it is recommended that the inoculation amount should not be less than 2,500 cells / well ( 100 µl medium ). If you want to use a 24-well plate or a 6-well plate experiment, first calculate the corresponding inoculation amount per well, and add the CCK-8 solution according to 10 % of the total volume of the medium per well ; 9.Cell culture time varies according to the type and number of cells ( per well ), usually the color of white blood cells is weak, requiring a longer culture time ( 4 hours ) and a large number of cells ( ~ 105 cells / well ) ; 10.CCK-8 reagent is very low toxic to cells. The continuous reaction between it and dehydrogenase in living cells makes the color of the solution deepen and the OD value increase. The following methods can terminate the CCK-8 reaction ( 96-well plate ) : a ) After the color reaction, the culture plate was placed in a refrigerator at 4 ° C ; b ) 10µL 0.1MHCL solution was added to each well ; c ) 10 µL 1 % ( w / v ) SDS ( sodium dodecyl sulfate ) solution was added to each well. After the reaction stopped, the OD value should be measured within 24 hours. 11.To determine the specific number of cells, it is recommended to do the standard curve at the same time... Read More |