| Description | Inquire | The aladdin 488 Caspase-3 live cell assay kit contains the aladdin 488 Caspase-3 substrate and the Ac-DEVD-CHO Caspase-3 inhibitor. aladdin 488 Caspase-3 Substrate provides an effective tool for detecting apoptosis based on Caspase-3 activity, suitable for fluorescence microscopy and flow cytometry.The aladdin 488 Caspase-3 live cell assay kit contains the aladdin 488 Caspase-3 substrate and the Ac-DEVD-CHO Caspase-3 inhibitor. aladdin 488 Caspase-3 Substrate provides an effective tool for detecting apoptosis based on Caspase-3 activity, suitable for fluorescence microscopy and flow cytometry. Compared with other fluorescent substrates or fluorescent inhibitors of Caspase based on ( FLICA ) analysis, aladdin 488 Caspase-3 Substrate does not inhibit the apoptosis process of intact cells while detecting Caspase-3 activity. Substrate is composed of fluorescent DNA dyes coupled with Caspase-3 DEVD recognition sequence. Substrate initially had no fluorescence and entered the cytoplasm through the cell membrane. In apoptotic cells, Caspase-3 cleaves the Substrate and releases high-affinity DNA staining, which migrates to the nucleus to label DNA and emits bright green fluorescence.Therefore, aladdin 488 Caspase-3 Substrate is bifunctional, which can not only detect Caspase-3 activity, but also visualize the morphological changes of the nucleus during apoptosis. Aladdin 488 staining can be fixed in formaldehyde and compatible with subsequent immunostaining experiments.Parameters:aladdin 488:Ex/Em = 500/530 nm (with DNA)Component:Points for attention:1.Please instantaneously centrifuge the product to the bottom of the tube before use, and then carry out subsequent experiments. 2.Cells can be co-stained with a final concentration of 1µM Hoechst 33342 dye to produce blue fluorescence staining of the nucleus ( Ex / Em = 346 / 460 nm ). 3.Aladdin 488 staining can be fixed by formaldehyde, but it is not compatible with methanol fixation. 4.Formaldehyde-fixed aladdin 488-stained cells can be treated with 0.1 % TritonX-100 for subsequent staining, but the brightness of the treated staining may be weakened. 5.Fluorescent dyes all have quenching problems, please try to avoid light to slow down the fluorescence quenching. 6.For your safety and health, please wear experimental clothes and wear disposable gloves.Scope of application:Caspase 3 kit and apoptosis detectionUsage:1. Experimental optimization: The experimental steps provided below are based on the endpoint detection system. Aladdin 488 Substrate can also be used for long-term cell incubation course research. Cell density, substrate concentration, and inhibitor concentration may need to be optimized. The optimal substrate concentration may be between 1-10 µ Between M. Cells can be incubated with substrates in culture medium, PBS, or other buffer of your choice. For adherent cells, we recommend replacing them with fresh culture media containing substrates to prevent background heterogeneity. The operation of changing the medium or washing the cells after substrate incubation is freely selectable.2. We suggest that you set the following controls:A. Negative control: cells that do not induce apoptosis;B. Positive control: cells that induce apoptosis;C. Inhibitor control: Induce cell apoptosis while incubating Caspase-3/7 inhibitors (or 10-30 minutes in advance), and finally add Aladdin 488 Caspase-3 substrate.3. The Caspase-3/7 inhibitor Ac-DEVD-CHO in the Ac-DEVD-CHO Caspase-3 inhibitor control kit can be used to confirm that Caspase-3/7 depends on the fluorescence signal of aladdin 488. For inhibitor control, the final concentration of the inhibitor should be at least twice the substrate concentration (e.g. when using 5 µ At substrate M aladdin 488, the concentration of Ac-DEVD-CHO is 10 µ M). Before adding the substrate, incubate Ac-DEVD-CHO at room temperature for 15-30 minutes. After adding the substrate, continue to retain the inhibitor in the incubation solution. Ac-DEVD-CHO is a reversible competitive inhibitor. In certain cell types, effective Caspase-3/7 inhibitors require the use of irreversible inhibitors, such as Z-DEVD-FMK, or the addition of inhibitors before or during apoptosis induction.4. Flow cytometry(1) Choose appropriate methods to induce cell apoptosis, with untreated cell samples as controls.(2) Adhering cells should be digested with trypsin or other methods before performing the aladdin 488 Caspase-3 experiment.(3) Resuspend cells with culture medium or buffer to achieve a cell density of 106 cells/mL(4) Suck 0.2 mL of cell suspension into a flow cytometry test tube.(5) Inhibitor control samples were treated with Ac-DEVD-CHO on cells (see 3 above) Ac-DEVD-CHO Caspase-3 inhibitor control.(6) 200 µ Add 5 to L cell suspension µ Substrate of 0.2 mM and immediately mix to achieve a substrate concentration of 5 µ M. The optimal substrate concentration for different cells may vary and requires analysis and optimization.(7) Incubate cells at room temperature in dark for 15-30 minutes.(8) Join 300 µ L-medium or PBS, analyzed by flow cytometry. Detect the channel for green fluorescence (Ex/Em=485/515 nm).5. Fluorescence microscope(1) Choose appropriate methods to induce cell apoptosis, with untreated cell samples as controls.(2) Inhibitor control samples were treated with Ac-DEVD-CHO on cells (see 3 above) Ac-DEVD-CHO Caspase-3 inhibitor control.(3) Using a solution containing 5 µ M Substrate's fresh culture medium or PBS is used to replace the cell culture medium (see 1 above) Experimental optimization). For the inhibitor control group, the inhibitor was incubated together with the substrate.(4) Incubate cells at room temperature for 30 minutes or longer.(5) Cells can be directly observed in culture media containing Substrate. For the endpoint analysis method, PBS was used to clean the cells, fluorescence microscopy was used to observe the cells, and a filter (Ex/Em=485/515 nm) was used to observe green fluorescence.6. Fluorescence enzyme-linked immunosorbent assay (ELISA) reader(1) Adherent cells grow in black 96 well plates; Suspend cells, adjust the density to 106 cells/mL, and divide 0.2 mL of cell suspension into one well.(2) Choose appropriate methods to induce cell apoptosis, with untreated cell samples as controls. Note: Cells may be processed in tubes or bottles and then transferred to a 96 well detection plate.(3) Inhibitor control samples were treated with Ac-DEVD-CHO on cells (see 3 above) Ac-DEVD-CHO Caspase-3 inhibitor control.(4) For suspended cells, directly add Substrate and mix well. For adherent cells, use a solution containing 5 µ M Substrate's fresh culture medium or PBS is used to replace the cell culture medium (see 1 above) Experimental optimization). For the inhibitor control group, the inhibitor was incubated together with the substrate.(5) Cells can be directly observed in culture media containing Substrate.(6) For suspended cells, gently shake to resuspend the cells. The fluorescence enzyme-linked immunosorbent assay instrument is set with an excitation wavelength of 488 nm and an emission wavelength of 520 nm. Suggest using bottom collection method for adherent cells. Changes in the density of adherent cells may lead to inaccurate readings... Read More | DescriptionCobalt is a transition metal that serves as a trace dietary mineral for all multicellular organisms. Cobalt is an important cofactor for the Vitamin B12class of compounds where it occupies the center of the vitamin B12corrin ring. Cobalt can also be coordinated in the active site of the DescriptionCobalt is a transition metal that serves as a trace dietary mineral for all multicellular organisms. Cobalt is an important cofactor for the Vitamin B12class of compounds where it occupies the center of the vitamin B12corrin ring. Cobalt can also be coordinated in the active site of the non-corrin containing metalloenzyme methionine aminopeptidase.Suitability: Suitable for quantitating cobalt concentrations in a variety of samplesPrinciple: The Cobalt Assay kit provides a simple and direct procedure for measuring cobalt in a variety of samples. In this assay, cobalt reacts with 2-mercaptoethanol under basic conditions to form a complex with a strong absorbance at 475 nm. Interference from the metal ions Fe2+, Cu2+, Ni2+, Zn2+, and Mn2+is <10% at this wavelength. This assay gives a linear range of 10-50 nmoles of cobalt.}Preparation instructionsSuitable for quantitating cobalt concentrations in a variety of samplesPrincipleThe Cobalt Assay kit provides a simple and direct procedure for measuring cobalt in a variety of samples. In this assay, cobalt reacts with 2-mercaptoethanol under basic conditions to form a complex with a strong absorbance at 475 nm. Interference... Read More | DescriptionPhoto KitAlysis Starter Kit enables screening of 24 micro-scale simultaneous photocatalytic reactions with consistent and reproducible photon intensity. User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsComponents:Photo KitAlysis LED ControllerBlue LED DescriptionPhoto KitAlysis Starter Kit enables screening of 24 micro-scale simultaneous photocatalytic reactions with consistent and reproducible photon intensity. User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsComponents:Photo KitAlysis LED ControllerBlue LED Array (470 nm)Photo KitAlysis Reaction BlockTorque screwdriverSmall screwdriver to easily remove torqued screws after reaction is completeFeatures:Designed and tested by synthetic chemists.Controller provides repeatable milliamp selection for photon intensity0-30 mA variable LED output3 different LED options: blue (470 nm, included), green (527 nm, sold separately), and white (sold separately)Non-magnetic LED baseChemically resistant LED coverPTFE coated cablingDesigned to be used withPhoto KitAlysis High-Throughput Reaction Screening Kit(sold separately).Best when used withKitAlysis Benchtop Inertion Box(sold separately)... Read More | Products contentProducts IntroductionThis product uses the principle that the difference between the concentration of salt ions inside and outside the cell can cause the cell membrane to burst to lyses the cell and releases the genomic DNA, without the need of extracting and purifying the genomic Products contentProducts IntroductionThis product uses the principle that the difference between the concentration of salt ions inside and outside the cell can cause the cell membrane to burst to lyses the cell and releases the genomic DNA, without the need of extracting and purifying the genomic DNA.This product is suitable for a variety of sources of samples, and can be used as a template for PCR and qPCR experiments after sample processing, and can achieve the effect of the purified DNA used as a template for PCR and qPCR experiments. Usage1. Depending on the type of sample, prepare the appropriate sample size according to the table below.2. Add the sample to a 1.5-mi centrifuge tube and add the recommended volume of Solution A as shown in the table below. Vortex for 20 s and allow to stand at room temperature for 3-5 min or incubate in a metal bath at 95°C for 3-5 min as recommended in the table below.3. After the sample has been sufficiently lysed (samples incubated in a metal bath at 95°C should be brought to room temperature), add the recommended volume of Solution B as shown in the table below and vortex for 30s.4. Store processed samples at 4°C if the next test is to be performed within 2 hours, or at -20°C if the next test cannot be performed immediately.take note of1) Depending on the requirements of the experimental conditions, the amount of samples can be expanded or reduced, and the amount of Solution A and Solution B can be increased in equal proportions.2) For blood and cell samples, the temperature of room temperature lysis is required to be around 25C. If the ambient temperature does not reach 25°, the lysis time can be extended appropriately, or the vortex shaking time can be extended to ensure that the samples are fully lysed. If there is no relevant professional instrument, the centrifuge tube can be shaken vigorously to ensure adequate lysis.3) After the tissue sample is made into tissue homogenate by adding 10 times the volume of saline, it can be processed in the same way as blood samples.4) Strictly prohibit the use of expired products, please do not mix different reagents.5) laboratory supplies should be regularly cleaned and 10% of the 84 disinfectant solution or ultraviolet lamp for anti-pollution treatment, special areas dedicated to prohibit cross use, so as to avoid contamination, the end of the test, the bench should be cleaned immediately... Read More |