| Description | Inquire | DescriptionIt contains a set of seven different homogeneous palladium catalysts, useful for rapid screening of catalysis conditions. It is in sampler format with individual components packaged for multiple experiments and mini scale-up. The cost of the kit is less than the total cost of individual DescriptionIt contains a set of seven different homogeneous palladium catalysts, useful for rapid screening of catalysis conditions. It is in sampler format with individual components packaged for multiple experiments and mini scale-up. The cost of the kit is less than the total cost of individual components.Catalysis Screening Kits... Read More | The commonly used method of eukarYOtic gene expression regulation research is the detection of reporter genes, and bioluminescence is the most commonly used and effective means of reporter gene detection. Luciferase can catalyze the conversion of the substrate luciferin and emit photons. This The commonly used method of eukarYOtic gene expression regulation research is the detection of reporter genes, and bioluminescence is the most commonly used and effective means of reporter gene detection. Luciferase can catalyze the conversion of the substrate luciferin and emit photons. This product provides a rapid, sensitive and stable detection method for the expression of Renilla luciferase reporter gene in mammalian cells. Product characteristic:1.Rapid : Cell lysis was completed within 10-15 min ;2.Convenience : The reagent is easy to prepare, and the sample detection steps are simple;Instruction:1. Cell lysis ( 1 ) Remove the culture medium and gently wash with PBS ( adherent cells can be directly performed this operation, suspension cells should be centrifuged to collect cells ). Add 1 × Lysis Buffer ( diluted component A with sterile water at 4 : 1 ) according to the following scheme, and then place the culture plate on a micro-oscillator at room temperature for 15 min to fully lyse the cells. Note : The pyrolysis products can be stored at room temperature for 6 h, and can be stored at − 70 °C for a long time ( the pyrolysis products cannot be repeatedly frozen and thawed ). ( 2 ) The pyrolysis products after full pyrolysis were centrifuged at 10000-15000 rpm for 3-5 min. After centrifugation, the supernatant was moved into a new EP tube for subsequent detection. 2. Preparation of working fluid ( 1 ) Restore all components to room temperature. ( 2 ) Dilute component C into renilla luciferase working solution with component B, and the dilution method is to add 1 µL C component to 49 µL B component. 3.chemiluminescence value detection ( 1 ) According to the operation instructions of the instrument, the instrument with chemiluminescence detection function was opened, such as multifunctional microplate reader. The parameters were set, the determination time was 10 s, and the determination interval was 2 s. ( 2 ) The cell lysis products were added to the measuring tube according to the volume of 20 ~ 100 µL ( keep the same amount of samples each time ). 1 × Lysis Buffer was blank control. ( 3 ) 100 µL renilla luciferase working solution was added to determine the RLU ( Relative light unit ) value ( Shaking mixing function is recommended for microplate reader ). Note : The renilla luciferase working solution cannot be stored for a long time. It is now ready for use and is used once. Component:RenillaLuciferase Lysis Buffer;RenillaLuciferase Assay Buffer;CoelenterazineMatters needing attention:Scope of application: Matters needing attention:1.Please instantaneously centrifuge the product to the bottom of the tube before use, and then carry out subsequent experiments ; 2.Due to the influence of temperature on the enzyme reaction, the sample and reagent should be measured after reaching room temperature. 3.The strongest wavelength of bioluminescence catalyzed by renilla luciferase is 480 nm, in order to prevent interference between holes, it is recommended to use white opaque orifice plate ;4. B component is recommended to carry out small batch packing according to the experimental requirements ; 5.It is recommended to use it now to avoid repeated freezing and thawing ; 6.For your safety and health, please wear experimental clothes and wear disposable gloves. Scope of application:Study on gene expression regulation and promoter... Read More | This kit is suitable for extracting total RNA from fresh whole blood (blood samples treated with anticoagulants such as citrate, EDTA, or heparin). It can process up to 1.5 ml of whole blood and elute to obtain high-purity RNA with a molecular weight greater than 200 bp. Multiple samples can be This kit is suitable for extracting total RNA from fresh whole blood (blood samples treated with anticoagulants such as citrate, EDTA, or heparin). It can process up to 1.5 ml of whole blood and elute to obtain high-purity RNA with a molecular weight greater than 200 bp. Multiple samples can be completed simultaneously within 1 hour. This product does not require the ultra centrifugation step of CsCl purification and LiCl or ethanol precipitation. It does not contain toxic solvents such as phenol or chloroform. The purified RNA effectively removes enzyme inhibitors and pollutants such as heme and heparin. It can be directly used in various molecular biology routine experiments, such as RT-PCR, Northern Blot, Dot Blot, in vitro translation, and so on.Self prepared reagents: β- Mercaptoethanol, 70% ethanol (prepared with water without RNase), anhydrous ethanol. R666034 Component 50 T Storage R666034A Buffer RBL (10×) 60 mL RT R666034B Buffer RL 35 mL RT R666034C Buffer RW1 40 mL RT R666034D Buffer RW2 (concentrate) 11 mL RT R666034E RNase-Free Water 10 mL RT R666034F Spin Columns FL with Collection Tubes 50 sets RT R666034G Spin Columns RM with Collection Tubes 50 sets RT R666034H RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RT Preparation and important precautions before the experimentTo prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The sample should avoid repeated freezing and thawing, otherwise it will affect the yield and quality of RNA extraction. The sample can be stored in Buffer RL at -70 ℃ for one month.3. Before use, please check if there is any crystallization or precipitation in the Buffer RL. It can be dissolved again in a 56 ℃ water bath. Please add Buffer RL before use β- Mercaptoethanol, with a final concentration of 1%. Add 10 to 1 ml Buffer RL µ L β- Mercaptoethanol. join β- The buffer RL room temperature of mercaptoethanol can be stored for one month.4. Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. This reagent kit cannot be used for RNA extraction from frozen blood samples with anticoagulants added.6.10 × Buffer RBL needs to be diluted 10 times with water without RNase before use, and then stored at 2-8 ℃ after dilution.7. If downstream experiments are highly sensitive to DNA, it is recommended to treat RNA with DNase I that does not contain RNase.8. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Operation steps1. Add 5 times the volume of 1 x Buffer RBL to fresh anticoagulant whole blood samples of 0.5-1.5 ml (please dilute 10 x Buffer RBL with RNase free water before use), gently vortex or invert and mix well. Incubate on ice for 10-15 minutes, mix twice during the incubation process.Attention: During the incubation process, the cloudy suspension will become transparent, indicating that red blood cells have been lysed. If necessary, the incubation time can be extended to 20 minutes. 2. Centrifuge at 4 ℃, 2100 rpm (~400 × g) for 10 minutes, and carefully discard the supernatant.3. Add 2 times the volume of the blood sample to the above precipitate with 1 x Buffer RBL (please dilute 10 x Buffer RBL with RNase free water before use), gently vortex, and resuspend the precipitate thoroughly. 4. Centrifuge at 4 ℃ and 2100 rpm for 10 minutes, carefully and thoroughly remove the supernatant.Note: This step must completely remove the supernatant, otherwise it will affect the lysis and lead to a decrease in RNA production.5. Add Buffer RL to the precipitate (check if it has been added before use β- Mercaptoethanol, 0.5-1.5 ml of blood sample added to 600 µ L Buffer RL, or less than 0.5 ml of blood sample added to 350 µ L Buffer RL, mix well.6. Transfer the obtained liquid to the spin columns FL that have been loaded into the collection tube, centrifuge at 12000 rpm (~13400 × g) for 2 minutes, collect the filtrate, and discard the filter column.7. Add 1 volume (600) to the obtained filtrate µ L or 350 µ l) Mix 70% ethanol (prepared without RNase water) well.Attention: Adding ethanol may cause precipitation and will not affect subsequent experiments.8. Add all the solution obtained in the previous step to the spin columns RM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred in multiple batches. Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.9. Add 700 to the adsorption column µ Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.Optional steps: If conducting RNA experiments that are highly sensitive to trace amounts of DNA, replace step 9 with the following steps.1) Add 350 to the adsorption column µ Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.2) Preparation of DNase I mixture: Take 70 µ Reaction Buffer and 10 µ L DNase I storage solution, gently mix and prepare to a final volume of 80 µ The reaction solution of L.Attention: The above system is configured according to our company's DNase I (D665537) reaction system. Please refer to the corresponding manual for other company products.1) Add 350 to the adsorption column µ Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.2) Preparation of DNase I mixture: Take 70 µ Reaction Buffer and 10 µ L DNase I storage solution, gently mix and prepare to a final volume of 80 µ The reaction solution of L.Attention: The above system is configured according to our company's DNase I (D665537) reaction system. Please refer to the corresponding manual for other company products.3) Add 80 µ l of the prepared DNase I reaction solution directly to the adsorption column and incubate at 20-30 ℃ for 15 minutes.4) Add 350 to the adsorption column µ Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.10. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 15 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.11. Repeat step 10. 12. Centrifuge at 12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).13. Place the adsorption column in a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 13 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 13... Read More | Products contentProducts IntroductionThis kit is suitable for simple, rapid and efficient isolation and purification of DNA/RNA from whole blood, tissue homogenates, swabs, serum, plasma and other cell-free body fluids, etc. The unique buffer system enables the viral nucleic acids in the lysate to Products contentProducts IntroductionThis kit is suitable for simple, rapid and efficient isolation and purification of DNA/RNA from whole blood, tissue homogenates, swabs, serum, plasma and other cell-free body fluids, etc. The unique buffer system enables the viral nucleic acids in the lysate to bind to the silica gel centrifugal adsorbent columns in a highly efficient manner, and the viral nucleic acids obtained are of high purity and stable quality, free of protein, nuclease and other impurities, and can be used in a variety of routine operations, including PCR, fluorescence quantitative PCR and other experiments. It can be used for a variety of routine operations, including PCR, fluorescence quantitative PCR and other experiments.Bring your own instrumentsThermostatic mixer.Pre-experiment Preparation and Important Notes1. Read these instructions carefully before experimenting.2. If Proteinase K is to be stored for a long period of time, please keep it at -20℃.3. Check Buffer RLC for crystallization or precipitation prior to use, and if crystallization or precipitation occurs, redissolve Buffer RLC in a 56°C water bath.4. Pre-treatment of tissue samples: Take 20 mg of tissue samples into 1.5 mL centrifuge tubes (self-provided), add 500 µL of Buffer RLC, and after the tissue homogenizer breaks up, centrifuge the samples for 1 minute at 12,000 rpm (~13,400×g), and take 200 µL of supernatant as samples. procedure1. Take a 1.5 mL centrifuge tube (provided), add 500 µL of Buffer RLC, 200 µL of sample, 20 µL of Proteinase K, vortex for 5 s, and then place it in a thermostatic mixer at 1200 rpm for 10 min at room temperature. Note: For wet swab samples, 200 µL of sample was taken after sufficiently shaking and mixing. Note: For wet swabs, 200 µL was taken from the sample after it was soaked in 400 µL of saline, shaken and mixed thoroughly for 5 minutes, and then centrifuged at 12,000 rpm for 1 minute, and 200 µL was taken for extraction.2. Instantly remove the centrifuge tube and add the solution from step 1 to the Spin Columns DM in the collection tube. centrifuge at 12,000 rpm (~13,400 x g) for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.3. Add 500 µL of Buffer PGWT to the adsorbent column, centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.4. Add 500 µL of Buffer GWT2 to the adsorbent column, centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.5. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Place the adsorption column at room temperature for 2 minutes and allow to dry.6. Place the column in a new collection tube (RNase-Free Centrifuge Tube), add 40-100 µL of RNase-Free Water to the center of the column membrane, let it stand at room temperature for 2 minutes, and then centrifuge at 12,000 rpm for 1 minute to collect the nucleic acid solution. Store at -80℃ for a long time... Read More |