| Description | Inquire | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917D DNA Standard B 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917E DNA Standard C 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917F DNA Standard D 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917G DNA Standard E 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis is a dye-based (SYBR Green I) qPCR NGS library quantification kit for cfDNA, which provides the reaction mixture, DNA primer mixture, standards, and sample dilutions required for the qPCR process, making it a complete reagent system that is easy and convenient to use. The fluorescent dye SYBR Green I contained in the reaction mixture binds to all double-stranded DNA. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, the length of the standard in the kit (about 270bp) is comparable to the average length of the cfDNA NGS libraries (250-300bp), which is able to quickly and accurately quantitate the concentration of the constructed cfDNA libraries. quantification.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.NOTE: High Rox and Low Rox are formulated as described in Method of Use 2.Applicable scopeThis product is designed for the absolute quantification of the concentration of Illumina platform second generation sequencing libraries. The end of the library contains Illumina P5 and P7 microarray binding sequences, the length of which does not exceed 1kb, and the concentration is not less than 0.02pM can be used for quantitative experiments. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-60 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR MasterMix10 µlqPCR Primer Mix0.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: 1 µl High Rox per 50 µl of reaction system; Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.3.qPCR reaction programIf the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.Refer to the specific instrument setup program for dissolution curves.data analysisStandard curve productionThe standard curve was plotted according to the data processing Excel sheet. The correlation coefficient R2 of the standard curve should be not less than 0.99, and the slope should be located between -3.1 and -3.6 when the Ct value is the longitudinal coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard A60 pMDNA Standard B6 pMDNA Standard C0.6 pMDNA Standard D0.06 pMDNA Standard E0.006 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More | Product introduction:This kit uses an improved SDS alkaline lysis method combined with DNA preparation membrane to selectively adsorb DNA to achieve the purpose of rapid purification of plasmid DNA. It is suitable for extracting up to 500ug of high-purity plasmid DNA from 120-300ml bacterial Product introduction:This kit uses an improved SDS alkaline lysis method combined with DNA preparation membrane to selectively adsorb DNA to achieve the purpose of rapid purification of plasmid DNA. It is suitable for extracting up to 500ug of high-purity plasmid DNA from 120-300ml bacterial culture for sequencing, in vitro transcription and translation, restriction enzyme digestion, bacterial transformation and other molecular biology experiments.Scope of application:Nucleic acid extraction and purification... Read More | Products contentProducts IntroductionThis kit is suitable for simple, rapid and efficient isolation and purification of DNA/RNA from whole blood, tissue homogenates, swabs, serum, plasma and other cell-free body fluids, etc. The unique buffer system enables the viral nucleic acids in the lysate to Products contentProducts IntroductionThis kit is suitable for simple, rapid and efficient isolation and purification of DNA/RNA from whole blood, tissue homogenates, swabs, serum, plasma and other cell-free body fluids, etc. The unique buffer system enables the viral nucleic acids in the lysate to bind to the silica gel centrifugal adsorbent columns in a highly efficient manner, and the viral nucleic acids obtained are of high purity and stable quality, free of protein, nuclease and other impurities, and can be used in a variety of routine operations, including PCR, fluorescence quantitative PCR and other experiments. It can be used for a variety of routine operations, including PCR, fluorescence quantitative PCR and other experiments.Bring your own instrumentsThermostatic mixer.Pre-experiment Preparation and Important Notes1. Read these instructions carefully before experimenting.2. If Proteinase K is to be stored for a long period of time, please keep it at -20℃.3. Check Buffer RLC for crystallization or precipitation prior to use, and if crystallization or precipitation occurs, redissolve Buffer RLC in a 56°C water bath.4. Pre-treatment of tissue samples: Take 20 mg of tissue samples into 1.5 mL centrifuge tubes (self-provided), add 500 µL of Buffer RLC, and after the tissue homogenizer breaks up, centrifuge the samples for 1 minute at 12,000 rpm (~13,400×g), and take 200 µL of supernatant as samples. procedure1. Take a 1.5 mL centrifuge tube (provided), add 500 µL of Buffer RLC, 200 µL of sample, 20 µL of Proteinase K, vortex for 5 s, and then place it in a thermostatic mixer at 1200 rpm for 10 min at room temperature. Note: For wet swab samples, 200 µL of sample was taken after sufficiently shaking and mixing. Note: For wet swabs, 200 µL was taken from the sample after it was soaked in 400 µL of saline, shaken and mixed thoroughly for 5 minutes, and then centrifuged at 12,000 rpm for 1 minute, and 200 µL was taken for extraction.2. Instantly remove the centrifuge tube and add the solution from step 1 to the Spin Columns DM in the collection tube. centrifuge at 12,000 rpm (~13,400 x g) for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.3. Add 500 µL of Buffer PGWT to the adsorbent column, centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.4. Add 500 µL of Buffer GWT2 to the adsorbent column, centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.5. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Place the adsorption column at room temperature for 2 minutes and allow to dry.6. Place the column in a new collection tube (RNase-Free Centrifuge Tube), add 40-100 µL of RNase-Free Water to the center of the column membrane, let it stand at room temperature for 2 minutes, and then centrifuge at 12,000 rpm for 1 minute to collect the nucleic acid solution. Store at -80℃ for a long time... Read More |