| Description | Inquire | Cell proliferation detection is a basic experimental method to evaluate the health of cells, genotoxicity and the effect of antitumor drugs. The most accurate method to detect cell proliferation is the BrdU method. Edu detection kit is a revolutionary breakthrough of BrdU method. Edu (5-Cell proliferation detection is a basic experimental method to evaluate the health of cells, genotoxicity and the effect of antitumor drugs. The most accurate method to detect cell proliferation is the BrdU method. Edu detection kit is a revolutionary breakthrough of BrdU method. Edu (5-ethynyl-2 '- deoxyuridine) is a pyrimidine analog that integrates into the DNA duplex during DNA synthesis. Edu detection is based on the "click" reaction. A copper catalyzed azide reacts covalently with alkynes to form covalent bonds. In this kit, edu contains alkynes, Aladdin ® 488 / 555/594/647a azide dyes contain azide compounds. The edu labeling proliferation of click method is rapid and effective, and easy to use. BrdU method requires DNA denaturation (such as acid denaturation, thermal denaturation or digestion with DNase) to expose BrdU, so as to facilitate BrdU antibody binding; The edu method only needs paraformaldehyde fixation and Triton X-100 penetration to make the detection reagent enter the cells, and only a small amount of azide dye is needed to label the integrated edu very effectively. This kit contains all components required for edu method detection, and can be used for proliferation detection of cultured cells in vitro.Component:Product parameters:555/565 nm;Instruction: Experimental materials (self provided). 10 mM PBS, pH 7.2-7.6. 4% paraformaldehyde fixing solution (in PBS)Propensive reagent (0.5% Triton X -100 in PBS). 2 mg/mL glycine solution (in ddH2O). 3% BSA in PBS, pH 7.2-7.6. 1% BSA in PBS, pH 7.2-7.6. ddH2O. 96/24/12/6 well culture plate or dishFluorescence microscopy detection method1. Cell cultureTake logarithmic growth stage cells and inoculate them into a 96 well plate with 4 × 103-1 × 105 cells per well (the number and density of cells can be adjusted according to cell size, growth rate, and specific requirements of experimental treatment), and culture until normal growth stage.2. Drug treatmentPerform various drug treatments according to experimental needs.3. EdU marking(1) Dilute EdU solution (component A) in a certain proportion with complete cell culture medium to an appropriate concentration, then add it to the cells and mix well; Set up a negative control group without EdU treatment.Note: The labeling concentration of EdU needs to be adjusted according to cell type, and it is recommended to explore with an initial concentration of 10 µ M. In the pre experiment, it is recommended to set an EdU concentration gradient, which can be referred to in Tables 2 and 3.(2) Incubate in a cell culture incubator for 2 hours.Note: The optimal incubation time is related to the cell cycle. Most tumor cell lines can use a 2-hour incubation time, as shown in Appendix 2. The concentration of EdU is related to the incubation time, and high concentrations, such as 10-50, should be used for short-term incubation (<2 hours) µ M; Long term incubation (>24 hours) should use low concentrations, such as 1-10 µ M; You can also refer to Appendix 3.4. Cell fixation and permeation promotionNote: For experiments that require cell surface antigen labeling, it can be considered to wash the cells twice with a 3% BSA washing solution after completing EdU incubation, before cell fixation and permeation promotion.(1) After incubation, remove the culture medium. Wash cells twice with 1X PBS for 5 minutes each time to remove EdU residues that have not been incorporated into DNA. Cells with weak adhesion can reduce cleaning intensity. Join 50 µ After incubating at room temperature for 20 minutes with 4% paraformaldehyde fixative, remove the fixative.(2) Add 50 to each hole µ L 2 mg/mL glycine solution, incubate at room temperature for 5 minutes, and neutralize the remaining fixed solution.(3) At a rate of 100 per hole µ Wash cells twice with 3% BSA.(4) Remove the washing solution and add 100 µ L 0.5% Triton X -100, incubate at room temperature for 10 minutes.5. EdU detectionNote: Each sample in this reference step uses 100 µ The working fluid of L can be adjusted by users according to their own sample situation.(1) Prepare 1 x Click iT EdU reaction buffer (component C): Dilute component C 10 times with ddH2O.(2) Configure 5 x Click iT EdU buffer additives (component E): add 300 µ Mix L of ddH2O into a 30 mg E component tube (final concentration of 100 mg/mL) until completely dissolved. After use, the remaining storage solution is stored at -20 ℃ and can be stored for one year. Once the solution turns brown, it indicates that the active ingredients have degraded and cannot be reused.Note: Different specifications of component E are dissolved in ddH2O according to this ratio, and prepared into a 5 x storage solution for future use.(3) Prepare 1 x Click iT EdU buffer additive: Dilute 5 x Click iT EdU buffer additive with ddH2O to 1 x, and the solution should be prepared and used immediately.(4) Prepare Click it working solution according to Table 1.Table 1 Click it working fluidReaction componentsTaking the sample size of 10 holes as an example1×Click-iT EdU Reaction buffer855 µLCuSO4 (Component D)40 µLYF® 488/555/594/647A Azide(Component B)5 µL1×Click-iT EdU Buffer additives100 µLTotal volume1 mL(5) Remove penetration enhancer, 100 per well µ Wash twice with 3% BSA washing solution of L.(6) Add 100 to each hole µ L Click iT working solution, evenly covering cells.(7) Incubate at room temperature in dark for 30 minutes.(8) Remove Click-iT working fluid and add 100 µ After washing cells twice with 3% BSA, remove the washing solution and add 100 µ L PBS keeps cells moist. If there are no other special requirements, photography analysis can be carried out.6. DNA re staining (optional)(1) Using 100 µ Wash the cells once with PBS and remove the washing solution.(2) Dilute Hoechst 33342 (component F) 2000 times with PBS.(3) Add 100 to each hole µ Incubate L 1 x Hoechst 33342 solution at room temperature in dark for 15-30 minutes.(4) Remove Hoechst 33342 solution and use 100 µ Wash cells twice with PBS.7. Imaging and analysisIt is recommended to take fluorescence microscopy photos immediately after staining is completed for observation; If conditions permit, please store in a dark and moist environment at 4 ° C for 3 days before taking photos. Flow cytometry detection method1. Cell cultureInoculate 1 × 105~3 × 106 cells per well into a 6-well plate.2. Drug treatmentPerform various drug treatments according to experimental needs.3. EdU labeled cells(1) Dilute EdU solution (component A) in a certain proportion with complete cell culture medium to an appropriate concentration, then add it to the cells and mix well; Set up a negative control group without EdU treatment.Note: The labeling concentration of EdU needs to be adjusted according to cell type, and it is recommended to explore with an initial concentration of 10 µ M. In the pre experiment, it is recommended to set an EdU concentration gradient, which can be referred to in Tables 2 and 3.(2) Incubate in a cell culture incubator for 2 hours. The time of EdU incubation of cells can be directly used as an indicator for measuring cell DNA synthesis, and the choice of time point and incubation time depend on the cell growth rate. Pulse labeled cells incubated with brief EdU can be used to study cell cycle dynamics.Note: The optimal incubation time is related to the cell cycle. Most tumor cell lines can use a 2-hour incubation time, as shown in Appendix 2. The concentration of EdU is related to the incubation time, and high concentrations such as 10-50 should be used for short-term incubation (<2 hours) µ M; Long term incubation (>24 hours) should use low concentrations, such as 1-10 µ M; You can also refer to Appendix 3.4. Cell fixation and permeation promotionNote: For experiments that require cell surface antigen labeling, it can be considered to wash cells twice with 1% BSA after completing EdU incubation, before cell fixation and permeation promotion.(1) After incubation, collect cells, add 1 mL of PBS to each tube to clean the cells, centrifuge at 1000 rpm for 5 minutes, and discard the supernatant to remove EdU residue that has not been added to DNA.(2) Add 1 mL of 4% paraformaldehyde fixative to each tube to resuspend cells.(3) Incubate at room temperature for 20 minutes, centrifuge at 1000 rpm for 5 minutes, and discard the supernatant.(4) Add 1 mL of 2 mg/mL glycine to each tube and incubate for 5 minutes. Neutralize the remaining fixed solution, centrifuge at 1000 rpm for 5 minutes, and discard the supernatant. Add 1 mL of PBS to each tube for cleaning once, centrifuge at 1000 rpm for 5 minutes, and discard the supernatant.(5) Add 1mL of 0.5% Triton X-100 osmotic enhancer to each tube and resuspend cells. Incubate at room temperature for 10 minutes.5. EdU detectionNote: For 6-well plate samples, reference can be made to 1 mL of working solution per well. Users can adjust the dosage according to their own sample situation.(1) Prepare 1 x Click iT EdU reaction buffer: Dilute component C 10 times with ddH2O.(2) Prepare 5 x Click iT EdU buffer additives (component E): Add 300 µ L ddH2O to 30 mg of component E in a test tube (final concentration 100 mg/mL), mix well until completely dissolved. After use, the remaining storage solution is stored at -20 ℃ and can be stored for one year. Once the solution turns brown, it indicates that the active ingredients have degraded and cannot be reused.Note: Different specifications of component E are dissolved in ddH2O according to this ratio to form 5 x storage solution for future use.(3) Prepare 1 x Click iT EdU buffer additive: Dilute 5 x Click iT EdU buffer additive storage solution with ddH2O to 1 x, and the solution should be prepared and used immediately.(4) Prepare Click it working solution according to Table 2.Table 2 Click it working fluidReaction componentsVolume of liquid required for a single reaction1×Click-iT EdU Reaction buffer875 µLCuSO4 (Component D)20 µLYF® 488/555/594/647A Azide(Component B)5 µL1×Click-iT EdU Buffer additives100 µLTotal volume1 mL(5) Soak at 1000 rpm for 5 minutes, discard the supernatant, remove the enhancer, add 1mL of 1% BSA washing solution to each tube and wash twice. Soak at 1000 rpm for 5 minutes, discard the supernatant.(6) Add 1 mL of Click iT working solution to each tube and mix well.(7) Incubate at room temperature in dark for 30 minutes.(8) Soak at 1000 rpm for 5 minutes, discard the staining reaction solution, add 1% BSA to each tube to wash the cells twice, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, and resuspend the cells again with 1 mL of 1% BSA (the volume of resuspend cells can be adjusted according to the number of cells), and detect with a flow cytometer.Note: If other biomarker tests are required, please refer to step 4.6. Intracellular antigen labeling (optional steps)(1) Add antibody working solution and mix well.(2) Under dark conditions, incubate antibodies at appropriate temperature and time.7. Flow detection and analysis:(1) It is recommended to conduct flow cytometry testing immediately after dyeing is completed; If conditions are limited, please store in a dark place at 4 ℃ for testing, but it should not exceed 3 days.(2) It is recommended to test the number of cells up to one million levels as much as possible. If the number of cells is small, the number of cells tested can be adjusted to 100000 levels starting from the experiment. For cases where the cell yield is too low (just to the level of ten thousand), it may not be conducive to making a flow chart. Therefore, the cleaning frequency in step 5 (8) can be appropriately reduced.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. fluorescent dyes have quenching problems. Please try to avoid light during experimental operation to slow down fluorescence quenching. 3. click it edu buffer additive solution should be prepared and used immediately to ensure the best results. 4. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Cell proliferation detection (cell imaging flow universal)... Read More | Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly luciferase is widely used in gene regulation and drug screening. Firefly luciferase is a protein with a molecular weight of about 61 KD. In the presence of ATP, magnesium ions and oxygen, it can catalyze the production of oxyluciferin from luciferin. In the process of luciferin oxidation, it will produce a light signal. The optical signal of this kit is a kind of instantaneous light, which needs to be detected immediately after adding the working solution. The half-life of optical signal is about 5 min.Instruction:1.Working fluid configuration ( 1 ) Restore all components to room temperature. ( 2 ) The component B ( stock solution ) was fully diluted with component A to prepare a 0.2 mg / mL firefly luciferase working solution, which was vortexed and shaken to ensure full mixing. Note : The firefly luciferase working solution cannot be repeatedly frozen and thawed. If the dosage of a single experiment is small, it is recommended to subpackage according to a single dosage. At room temperature, the activity decreased by about 10 % after the working solution was configured for 3 h, and the activity decreased by about 25 % after 5 h. 2.chemiluminescence value detection ( 1 ) The cell culture plate was taken out from the incubator and incubated at room temperature for 20 min to restore it to room temperature ( 22-25 ° C ). ( 2 ) Add the same volume of firefly luciferase working solution with the medium to the culture plate and mix well. ( 3 ) Incubation at room temperature for 5 min. Note : The incubation time can be adjusted according to cell type and cell number. ( 4 ) The values were read by multifunctional microplate reader or chemiluminescence instrument ( instrument parameters : the determination time was 10 s, the determination interval was 2 s ).Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. the strongest wavelength of bioluminescence catalyzed by firefly luciferase is 560 nm. 3. to prevent interference between holes, it is recommended to use white opaque orifice plate.Recommendation:Component B is recommended to use sterile water in advance to configure 2 mg / mL storage solution, A component and B component configured as storage solution, and small batch packaging according to the experimental requirements. The detection working fluid is recommended to be used now to avoid repeated freezing and thawing. Component:One-Step Firefly Luciferase Assay Buffer;D-Luciferin Scope of application:Mainly used for ADCC detection... Read More | R669988 Component 50T Storage R669988A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. R669988B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. R669988C Buffer RL 35 mL RT R669988D Buffer RLC 35 mL RT R669988E Buffer RW1 40 mL RT R669988F Buffer RW2 (concentrate) 11 mL R669988 Component 50T Storage R669988A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. R669988B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. R669988C Buffer RL 35 mL RT R669988D Buffer RLC 35 mL RT R669988E Buffer RW1 40 mL RT R669988F Buffer RW2 (concentrate) 11 mL RT R669988G RNase-Free Water 10 mL RT R669988H Spin Columns FL with Collection Tubes 50 sets RT R669988I Spin Columns RM with Collection Tubes 50 sets RT R669988J RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RTProductsThis kit is used for the extraction and purification of high-quality total RNA from a variety of plants, and is also suitable for the extraction of fungal mycelial RNA. The unique separation column is used for homogenization and filtration of high viscosity plant or fungal lysates, while the silicon matrix membrane is used to adsorb the RNA for purification, so that various contaminants, such as polysaccharides, are effectively removed by washing, and the eluted RNA can be directly used in various downstream experiments. The molecular weight of RNA extracted by this kit is more than 200 bases, with high purity and almost no DNA residue. For RNA experiments that are very sensitive to trace DNA, the residual DNA can be removed by digestion on a column using RNase-free DNase. The extracted RNA can be used in Northern Blot, Dot Blot, RT-PCR and in vitro translation experiments.Self-contained reagents: β-mercaptoethanol, anhydrous ethanol (freshly opened or for RNA extraction).Pre-experiment Preparation and Important Notes1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination.2) RNase-free water should be used to prepare the solution.(3) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.2. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination.(2) Glassware should be dry-roasted at 180°C for 4 hours before use, and plasticware can be soaked in 0.5M NaOH for 10 minutes, rinsed thoroughly with water and autoclaved.3) RNase-free water should be used to prepare the solution.(4) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.3. Avoid repeated freezing and thawing of the extracted samples, otherwise it will affect the amount and quality of RNA extraction.4. Please add β-mercaptoethanol to Buffer RL before use, add 10µl of β-mercaptoethanol to 1ml of Buffer RL, it can be stored for 1 month at room temperature. Buffer RL with β-mercaptoethanol can be stored at room temperature for 1 month. β-mercaptoethanol is not required for use of Buffer RLC.5. Anhydrous ethanol should be added to Buffer RW2 before first use according to the instructions on the reagent bottle label.6. If precipitation occurs in Buffer RL and Buffer RLC, heat to dissolve and leave at room temperature.7. All centrifugation steps are carried out at room temperature and all steps are performed quickly. Procedure1. 50-100 mg of plant tissue is quickly ground to a powder in liquid nitrogen and added to 600 µl of Buffer RL (check for addition of β-mercaptoethanol before use) or Buffer RLC. vortexing and oscillating to allow for adequate lysis.Note: 1) The main component of Buffer RL is guanidine isothiocyanate, which is suitable for lysis of most plant tissues. However, in some plant tissues (e.g. endosperm of corn), due to the special secondary metabolites, guanidine isothiocyanate causes precipitation of the sample, resulting in poor RNA extraction, in this case, Buffer RLC can be added instead of Buffer RL.2) Incubation at 56°C for 1-3 minutes helps tissue lysis, but do not incubate at high temperatures for plants with high starch content.2. Transfer all the liquid obtained in step 1 to an adsorption column (Spin Columns FL) that has been loaded into a collection tube, centrifuge at 12,000 rpm (~13,400 x g) for 2 minutes, and transfer the supernatant from the collection tube to a new centrifuge tube (supplied).Note: 1) The tip of the tip of the gun can be cut off when aspirating liquids to facilitate sampling.2) Spin Columns FL removes most of the debris, but a small portion will still flow out and a precipitate will form in the collection tube after centrifugation, so be careful to avoid aspirating the precipitate when proceeding to the next step.3. Add 0.5 times the volume of anhydrous ethanol to the clean lysate obtained in step 2 and mix rapidly.Note: Precipitation may occur upon addition of ethanol, but does not affect subsequent tests.4. Transfer the solution obtained in the previous step to the Spin Columns RM in the collection tube. If it is not possible to add all of the solution to the column at one time, centrifuge the column at 12,000 rpm for 15 seconds in two batches, discard the waste solution and put the column back into the collection tube.5. Add 350 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, discard the waste liquid and put the adsorbent column back into the collection tube.6. Preparation of DNase I mixture: Take 52µl of RNase-Free Water, add 8µl of 10×Reaction Buffer and 20µl of DNase I (1U/µl) to it, mix well, and make a final volume of 80µl of reaction solution.7. Add 80µl of DNase I mixture directly to the adsorption column and incubate at 20-30°C for 15 minutes.8. Add 350 µl of Buffer RW1 to the adsorption column, centrifuge at 12,000 rpm for 1 minute, discard the waste liquid and put the column back into the collection tube.9. Add 500 µl of Buffer RW2 to the column (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 15 seconds, and discard the waste solution.10. Repeat step 9.11. Place the adsorbent column back into the collection tube, centrifuge at 12,000 rpm for 1 minute, and allow the column to come to room temperature for a few minutes to thoroughly dry out the anhydrous ethanol in the adsorbent column.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (zymography, PCR, etc.).12. Load the adsorption column into a new centrifuge tube, add 30-50 µl of RNase-Free Water to the middle of the adsorbent membrane, leave it at room temperature for 1 minute, centrifuge at 12,000 rpm for 1 minute, and store the resulting RNA solution at -70°C to prevent degradation.Note: 1) The volume of RNase-Free Water should not be less than 30 µl, too small volume affects the recovery rate.2) If you want to increase the RNA yield, repeat step 12 with 30-50 µl of fresh RNase-Free Water.3) If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 12 repeated... Read More | S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948D DNA Standard 2 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948E DNA Standard 3 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948F DNA Standard 4 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948G DNA Standard 5 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis product is used for real-time fluorescence quantitative PCR (qPCR) using the product after NGS library construction by dye method (SYBR Green I). The kit provides the reaction mixture, DNA primer mixture, and standards required for the qPCR process, and the reagent system is complete, easy and convenient to operate. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, and able to quickly and accurately quantify the concentration of the constructed library. It is suitable for fluorescent quantitative PCR instruments that do not require ROX as a calibration dye, such as Roche LightCycler 480, Roche LightCyler 96, Bio-radiCyleriQ, iQ5, CFX96.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.Note: High Rox and Low Rox are formulated as described in Use 2.Scope of applicationThis product is designed for absolute quantification of the concentration of Illumina platform second-generation sequencing libraries. The end of the library contains Illumin P5 and P7 chip binding sequences, the length of which does not exceed 1kb, and the concentration of which is not less than 0.002pM can be used to perform quantitative experiments with this product. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-20 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR Master Mix10 µlqPCR Primer Mix 10.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: add 1 µl High Rox per 50 µl of reaction system;Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.qPCR reaction programThe annealing temperature should be 60-64°C as a reference for the setting range, and the annealing temperature can be increased when a non-specific reaction occurs.If the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.data analysisStandard curve productionThe standard curve was plotted using Ct values in the valid range. The standard curve correlation coefficient R2 should not be less than 0.99 and the slope should lie between -3.1 and -3.6. If the standard curve parameters are not reasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard 120 pMDNA Standard 22 pMDNA Standard 30.2 pMDNA Standard 40.02 pMDNA Standard 50.002 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More |