| Description | Inquire | B669951 Component 50T Storage B669951A Buffer ATL 15 mL RT B669951B Buffer AL 15 mL RT B669951C Buffer AW1 (concentrate) 13 mL RT B669951D Buffer AW2 (concentrate) 15 mL RT B669951E Buffer EB 15 mL RT B669951F Proteinase K 1.25 mL RT B669951G Spin Columns DM with Collection Tubes 50 sets B669951 Component 50T Storage B669951A Buffer ATL 15 mL RT B669951B Buffer AL 15 mL RT B669951C Buffer AW1 (concentrate) 13 mL RT B669951D Buffer AW2 (concentrate) 15 mL RT B669951E Buffer EB 15 mL RT B669951F Proteinase K 1.25 mL RT B669951G Spin Columns DM with Collection Tubes 50 sets RTProductsThis kit is suitable for extracting high purity total DNA from Gram-negative and Gram-positive bacteria. 106-108 cells can be processed at a time, and up to 20 µg of total DNA can be obtained within one hour without the need for toxic solvents such as phenol or chloroform, and without the need for ethanol precipitation. The optimized buffer system enables the DNA in the lysate to be efficiently and specifically bound to the silica matrix centrifugal adsorption column, while other contaminants can flow through the membrane, and the inhibitors of PCR and other enzymatic reactions can be effectively removed through a two-step washing step, and finally washed off with low-salt buffer or water, so that high-purity DNA can be obtained.The purified DNA can be used for downstream experiments such as digestion, PCR, Real-Time PCR, library construction, Southern Blot and molecular labeling, molecular labeling and other downstream experiments. Self-contained reagents: anhydrous ethanol; Enzymatic Lysis Buffer is required for extraction of Gram-positive bacteria.Enzymatic Lysis Buffer was prepared by 20 mM Tris, pH 8.0; 2 mM Na2-EDTA, pH 8.0; and 1.2% Triton X-100. 121°C sterilization for 20 minutes, and the appropriate amount of Lysozyme was added at a final concentration of 20 mg/ml. Pre-experiment Preparation and Important Notes1. Add 1.25ml Proteinase K Storage Buffer to Proteinase K to dissolve it and store it at -20℃. Do not leave the prepared Proteinase K at room temperature for a long time, and avoid repeated freezing and thawing to avoid affecting its activity.2. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller DNA fragments and a decrease in the amount of extracted DNA.3. If extracting genomes from bacterial cultures with high accumulation of secondary metabolites or thick cell walls, it is recommended that samples be collected early in the logarithmic phase.4. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.5. Before use, please check Buffer GTL and Buffer GL for crystallization or precipitation. If crystallization or precipitation occurs, please re-dissolve Buffer GL and Buffer GTL in a 56℃ water bath.6. If the downstream experiments are sensitive to RNA contamination, 4µl of DNase-Free RNase A (100mg/ml) can be added before adding Buffer GL. RNase A is not provided in this kit.If the extracted samples are Gram-positive bacteria, customers need to prepare their own Enzymatic Lysis Buffer to treat the bacteria, which requires the use of Lysozyme (lysozyme) at a concentration of 20 mg/ml, which is not provided in this kit.Procedurei Extraction of genomic DNA from Gram-negative bacteria1. Take 1-5 ml of bacterial culture (106-108 cells, maximum 2×109 cells) and put it into a centrifuge tube (provided), centrifuge it at 12,000 rpm (~13,400×g) for 1 minute, and aspirate the supernatant as much as possible.2. Add 180 µl Buffer GTL to the precipitate and shake to resuspend the bacteria.3. Add 20 µl of Proteinase K, vortex and mix well, incubate at 56°C until the solution becomes clear, and invert or shake the centrifuge tube at intervals during the incubation to disperse the sample.Note: If RNA removal is required, add 4 µl of RNase A solution at a concentration of 100 mg/ml after the above steps are completed, shake to mix, and leave for 5-10 minutes at room temperature.4. Add 200µl Buffer GL and mix well with vortexing and shaking. Add 200µl of anhydrous ethanol and mix well with vortexing and shaking.Centrifuge briefly so that the solution on the walls of the tube collects at the bottom.Note: 1) If multiple samples are manipulated together, Buffer GL and anhydrous ethanol can be mixed in equal proportions and then added together, shaking to mix.2) The addition of Buffer GL and anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.5. Add all of the solution obtained in step 4 (including the precipitate formed) to the Spin Columns DM in the collection tube, or if the solution cannot be added all at once, transfer it several times. centrifuge at 12,000 rpm for 1 minute, discard the waste solution, and return the column to the collection tube.6. Add 500 µl of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and return the adsorption column to the collection tube.7. Add 500 µl of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorbent column at room temperature for several minutes to dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorbent column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new centrifuge tube, add 50-200 µl Buffer GE to the middle part of the adsorption column overhanging the center of the adsorption column, leave it at room temperature for 2-5 minutes, centrifuge it at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20 ℃. note: 1) If the downstream experiments are sensitive to the pH or EDTA, the elution can be done with sterilized water. The pH of the elution solution has a great influence on the elution efficiency. If water is used as the elution solution it should be ensured that its pH is 7.0-8.5 (the pH of water can be adjusted to this range with NaOH), and the elution efficiency is not high when the pH is lower than 7.0.2) Incubation at room temperature for 5 minutes prior to centrifugation increases yield.3) Re-elution with an additional 50-200 µl Buffer GE or sterilized water can increase the yield.4) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 9 can be re-spiked onto the adsorbent membrane and step 9 repeated; if the elution volume is less than 200 µl, the final concentration of DNA can be increased, but the total yield may be reduced. If the amount of DNA is less than 1 µg, elution with 50 µl Buffer GE or sterilized water is recommended.(5) DNA stored in water will be affected by acidic hydrolysis. For long-term storage, it is recommended to elute with Buffer GE and store at -20℃.i. Extraction of genomic DNA from Gram-positive bacteria1. Take 1-5 ml of bacterial culture (106-108 cells, maximum 2×109 cells) and put it into a centrifuge tube (provided), centrifuge it at 12,000 rpm (~13,400×g) for 1 minute, and aspirate the supernatant as much as possible.2. Add 180µl Enzymatic Lysis Buffer (self-provided) to resuspend the bacteria.Enzymatic Lysis Buffer is prepared as described in the Self-Prepared Reagents section in the front of the manual.3. Incubate at 37°C for 30 minutes.4. Add 20µl Proteinase K and mix well. Add 200µl of Buffer GL and mix well with vortexing and shaking.Note: Do not add Proteinase K directly to Buffer GL.Incubate at 5.56°C for 30 minutes.Note: 1) If desired, incubation at 95°C for 15 minutes will inactivate the pathogen, but 95°C incubation will cause some DNA degradation.(2) If RNA removal is required, add 4µl of RNase A solution at a concentration of 100mg/ml after the above steps are completed, shake and mix well, and leave for 5-10 minutes at room temperature.6. Add 200µl of anhydrous ethanol and mix well with vortex shaking.Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.7. Add all of the solution obtained in step 6 (including the precipitate formed) to the Spin Columns DM that have been loaded into the collection tube, and if the solution cannot be added all at once, it can be transferred in several times. centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid from the collection tube, and put the column back into the collection tube.8. Add 500 µl of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.9. Add 500 µl Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge the column at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the column back into the collection tube.Note: Step 9 can be repeated if further DNA purity is required.10. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self-provided), add 50-200 µl of Buffer GE to the center of the adsorption column overhanging the center of the adsorption column, let it stand at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20℃.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH is 7.0-8.5 (you can use NaOH to adjust the pH of the water to this range), and the elution efficiency is not high when the pH is lower than 7.0.2) Incubation at room temperature for 5 minutes prior to centrifugation increases yield.3) Re-elution with an additional 50-200 µl Buffer GE or sterilized water can increase the yield.4) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 11 can be re-spiked onto the adsorbent membrane and step 11 repeated; if the elution volume is less than 200 µl, the final concentration of DNA can be increased, but the total yield may be reduced. If the amount of DNA is less than 1 µg, elution with 50 µl Buffer GE or sterilized water is recommended.(5) DNA stored in water will be affected by acidic hydrolysis. For long-term storage, it is recommended to elute with Buffer GE and store at -20℃... Read More | Apoptosis refers to the cell autonomous and orderly death controlled by genes to maintain the stability of the internal environment. Apoptosis is different from cell necrosis. Apoptosis generally refers to a programmed cell death process that occurs during the development of body cells or under the Apoptosis refers to the cell autonomous and orderly death controlled by genes to maintain the stability of the internal environment. Apoptosis is different from cell necrosis. Apoptosis generally refers to a programmed cell death process that occurs during the development of body cells or under the action of some factors through the regulation of intracellular genes and their products. Cell necrosis is a cell death process that is caused by strong physical and chemical or biological factors to cause disordered changes in cells. The difference between apoptosis and necrosis lies in the characteristic morphological and biochemical changes, including the changes of cell membrane permeability and nuclear chromatin, the contraction of cytoplasm and the loss of membrane asymmetry. The oxazole yellow/pi membrane permeability apoptosis detection kit produced by our company is a dual fluorescence detection kit based on oxazole yellow and PI dyes. This kit is suitable for fluorescence microscopy, flow cytometry, fluorescence microplate reader and other fluorescence detection systems. Oxazole yellow is a non cell membrane penetrating cyanine monomer green fluorescent dye with high affinity for DNA. It basically has no fluorescence when it is not bound to DNA, but can emit bright green fluorescence after binding to DNA. When apoptosis occurs, the permeability of cell membrane changes. At this time, oxazole yellow can enter the cell and bind to DNA, emitting bright green fluorescence. Therefore, it is often used for the detection of apoptosis. It should be noted that oxazole yellow can also stain dead cells, so it needs to be double stained with PI that specifically fluorescently stains dead cells to effectively determine apoptosis. PI (propidium iodide) is a red fluorescent dye that can stain DNA. It is an analog of pyridine bromide that releases red fluorescence after embedding double stranded DNA. Although PI cannot pass through the membrane of living cells, it can cross the damaged cell membrane of dead cells to stain nuclei. Therefore, oxazole yellow combined with PI can be directly used for the detection of apoptosis. Apoptotic cells show green fluorescence, dead cells show both red and green fluorescence positive, and living cells have little or no fluorescence.Components: Components O598364-50T A. Oxazole yellow dye 50 µL B. Propidium Iodide (PI) 50 µLUsage (using flow cytometry as an example):1. Cell preparation(1) For adherent cells, after trypsin digestion, resuspend in culture medium and wash once with pre cooled PBS; The digestion time of trypsin should not be too long to prevent false positives. Note: Digest with trypsin and allow the cells to recover in the optimal cell culture conditions and medium for about 30 minutes, then stain.(2) For suspended cells, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, and wash once with pre cooled PBS.2. Cell stainingSuspend cells in pre cooled PBS, with a recommended cell count of 106 cells/mL per sample. Add 1 µ L Oxazole Yellow and 1 µ L to 1 mL of the samplePI, Gently blow and mix well. Incubate on ice in the dark for 30 minutes. Note: We suggest adding the following two experimental controls:Blank tube: negative control group cells, without dye, used to regulate voltage.Single staining tube: Positive control group cells were treated with only two tubes, Oxazole yellow and PI, for regulating compensation.3. Flow detectionAfter incubation, the sample can be directly detected by flow cytometry, or centrifuged at 1000 rpm for 5 minutes, the supernatant can be aspirated, and the sample can be resuspended in 1 mL of pre cooled PBS for flow cytometry detection. Oxazole yellow can be excited by a 488 nm laser, and the detected fluorescence emission spectrum is around 530 ± 30 nm (FITC channel), while the PI channel emission spectrum is around 617 nm (PI or PE channel).Product parameters:Oxazole yellow dye:ex/em = 491 / 509 nm (bound DNA); Propidium iodine:ex/em = 535 / 617 nm (combined with DMatters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. fluorescent dyes have quenching problems. Please try to avoid light to slow down fluorescence quenching. 3. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Membrane permeability apoptosis assay... Read More | Products R669890Component50 TStorageR669890ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669890B10×Reaction Buffer1mL-20℃. Avoid freeze/thaw cycle.R669890CBuffer RL35 mLRTR669890DBuffer RW140 mLRTR669890EBuffer RW2 (concentrate)11 mLRTR669890FRNase-Free Water10 mLRTR669890GSpin Products R669890Component50 TStorageR669890ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669890B10×Reaction Buffer1mL-20℃. Avoid freeze/thaw cycle.R669890CBuffer RL35 mLRTR669890DBuffer RW140 mLRTR669890EBuffer RW2 (concentrate)11 mLRTR669890FRNase-Free Water10 mLRTR669890GSpin Columns FL with Collection Tubes50 setsRTR669890HSpin Columns RM with Collection Tubes50 setsRTR669890IRNase-Free Centrifuge Tubes (1.5 mL)100 EART ProductsThis kit adopts centrifugal adsorption columns with high efficiency and specificbinding of nucleic acids and unique buffer system, which can rapidly extract totalRNA from bacteria or cultured animal cells.The reaction can be completed in 30-40minutes, and the extracted total RNA is extremely pure and free of protein and othercontaminants, which is suitable for RT-PCR, Real-Time RT-PCR, microarray analysis,in vitro translation and other experiments. Self-contained reagents: Lysozyme, β-mercaptoethanol, anhydrous ethanol (freshlyopened or for RNA extraction). Pre-experiment Preparation and Important Notes 1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination. 2) RNase-free water should be used to prepare the solution. 3) Operators wear disposable masks and gloves, and change gloves diligently duringthe experiment. 2. Add β-mercaptoethanol to Buffer RL before use to reach a final concentrationof 1%, e.g., add 10 µl of β-mercaptoethanol to 1 ml of Buffer RL. Buffer RL withβ-mercaptoethanol can be stored at 4℃ for 1 month, if precipitation occurs, pleaseheat to dissolve and use.3. Anhydrous ethanol should be added to Buffer RW2 before first use according tothe instructions on the reagent bottle label. 4. All centrifugation steps are carried out at room temperature if not otherwisespecified, and all steps should be performed quickly. Procedure 1. Centrifuge at 12,000 rpm (~13,400 x g) at 4°C for 2 minutes to collect theorganisms (maximum volume of organisms should not exceed 1 x 109) and carefullyremove all supernatants. Note: Supernatants that leave residues can interfere with the subsequent digestionprocess. 2. Thoroughly resuspend the organisms with 100 µl of TE buffer containing Lysozymeand incubate at room temperature. The specific formulation and incubation time areas follows:/The final concentration of Lysozyme in TE bufferincubation timeG-germ400µg/ml3-5minG+germ3mg/ml5-10min 3. Add 350 µl of Buffer RL (check that β-mercaptoethanol has been added beforeuse), vortex and shake to mix (insoluble precipitate may appear in this step), addall of the solution and the precipitate to the filter columns (Spin Columns FL) thathave been loaded into the collection tubes, and centrifuge at 12,000 rpm for 2minutes. 4. Add 250 µl of anhydrous ethanol to the filtrate obtained in the previous stepand mix well (a precipitate may appear at this point). Transfer the resulting solution together with the precipitate to a Spin Columns RM packed in a collectiontube, centrifuge at 12,000 rpm for 1 min, discard the waste solution and put thecolumn back into the collection tube.5. Add 350 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for1min, discard the waste liquid and put the adsorbent column back into the collectiontube.6. Preparation of DNase I mixture: Take 52µl of RNase-Free Water, add 8µl of 10×Reaction Buffer and 20µl of DNase I (1U/µl) to it, mix well, and make a finalvolume of 80µl of reaction solution.7. Add 80µl of DNase I mixture directly to the adsorption column and incubate at20-30°C for 15 minutes.8. Add 350 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for1min, discard the waste liquid and put the adsorbent column back into the collectiontube.9. Add 500 µl of Buffer RW2 to the column (check that anhydrous ethanol is addedbefore use), centrifuge at 12,000 rpm for 1 min, and discard the waste solution.10. Repeat step 9.11. Place the adsorbent column back into the collection tube and centrifuge at 12,000rpm for 2 minutes. Note: The purpose of this step is to remove residual ethanol from the adsorptioncolumn; ethanol residue can interfere with subsequent enzymatic reactions (zymography, PCR, etc.).12. Load the adsorption column into a new RNase-Free collection tube, add 30-50 µl of RNase-Free Water to the middle of the adsorption membrane, leave it at roomtemperature for 1 minute, centrifuge at 12,000 rpm for 1 minute, collect the RNAsolution, and store the RNA at -70°C to prevent degradation. Note: 1) The volume of RNase-Free Water should not be less than 30 µl, too smallvolume affects the recovery rate. 2) If you want to increase the RNA yield, repeat step 12 with 30-50 µl of freshRNase-Free Water. If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 12 repeated... Read More | Inquire |