| Description | Inquire | Product introduction:Product introduction:Cell Cycle Assay Kit Plus ( Cell Cycle Assay Kit Plus ) has certain applicability for live cells and fixed cell cycle detection. For different types of cells, whether it is applicable or not needs to be determined after testing. Cell Cycle Product introduction:Product introduction:Cell Cycle Assay Kit Plus ( Cell Cycle Assay Kit Plus ) has certain applicability for live cells and fixed cell cycle detection. For different types of cells, whether it is applicable or not needs to be determined after testing. Cell Cycle Assay Kit Plus ( Cell Cycle Assay Kit Plus ) uses RedNucleus I staining to detect cell cycle. RedNucleus I is a far-infrared nucleic acid dye with cell membrane permeability, which can quickly enter living cells, specifically bind to DNA, and perform cell cycle detection on living cells without RNase digestion. Compared with the traditional PI staining method, the cells do not need to be broken or fixed, and the operation is simpler. RedNucleus I is a fluorescent dye of double-stranded DNA, and the fluorescence intensity after binding to double-stranded DNA is proportional to the content of double-stranded DNA. The intracellular DNA content can be measured by flow cytometry, and then the cell cycle analysis can be carried out according to the distribution of DNA content. After RedNucleus I staining, assuming that the fluorescence intensity of G0 / G1 phase cells is 1, the theoretical value of the fluorescence intensity of G2 / M phase cells containing two copies of genomic DNA is 2, and the fluorescence intensity of S phase cells undergoing DNA replication is between 1-2. In addition, RedNucleus I is compatible with dyes such as Horizon BV / BUV, FITC and R-PE, and can be periodically detected after sample staining.The kit is usually used to detect the cell cycle of cultured adherent or suspended cells. If it is used for cell cycle detection of tissues, the tissues must be digested into a single cell state.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. this product is applicable to the detection of living cells and fixed cell cycle with certain limitations. Whether it is applicable to different types of cells needs to be determined after testing. If fixation is needed, it is recommended to use ice bath pre cooling 75-80% ethanol -20 ℃ to fix cells overnight. 3. fluorescent dyes have quenching problems. Please try to avoid light during storage and use to slow down fluorescence quenching. 4. for your safety and health, please wear experimental clothes and disposable gloves.Instruction: Experimental materials ( self-provided ):①cell lines or other cell samples ( self-prepared ) ;②This kit ; ③ trypsin ( self-prepared ) ;④ Cell culture medium containing FBS ( self-prepared ) ; Experimental procedure: 1.Preparation of cell samples : ( 1 ) ( This step is for adherent cells, if suspended cells, can be carried out directly step ( 2 ) ) Digest cells with trypsin, add cell culture medium, gently blow away cells, collected into the centrifuge tube. Note : The number of cells on the machine needs to reach 50,000 and above, so the initial number of cells collected needs to be sufficient. ( 2 ) Centrifuged about 1000 g for 3-5 min to precipitate cells. Carefully remove the supernatant, add about 1 mL of ice bath pre-cooled 1 × staining buffer ( 10 × staining buffer diluted with diH2O at 1 : 10 ), re-suspend the cells. Repeat once. ( 3 ) Centrifuged about 1000 g for 3-5 min to precipitate cells. After the supernatant was discarded, 1 mL of culture medium was added to re-suspend the cells ( for fixed cells, 1 × PBS can also be used to re-suspend ). Gently flick the bottom of the centrifuge tube to properly disperse the cells to avoid cell aggregation. 2.Staining : 4 µL of RedNucleus I staining solution was added to each tube of cell samples, slowly and fully mixed, and incubated at room temperature in dark for 20 min ( or incubated at 37 ° C in dark for 5-10 min ). The optimal incubation time of different cells is different, and the staining time can be adjusted and optimized according to the actual staining effect to obtain a more ideal staining effect. 3.Flow cytometry detection and analysis : Excited at 638 nm by flow cytometry, it is recommended to detect in RL3 or FL4 channels, or use RL1 and RL2 channels. Cell DNA content analysis and light scattering analysis were performed using appropriate analysis software.Scope of application:Cell cycle detection... Read More | Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly luciferase is widely used in gene regulation and drug screening. Firefly luciferase is a protein with a molecular weight of about 61 KD. In the presence of ATP, magnesium ions and oxygen, it can catalyze the production of oxyluciferin from luciferin. In the process of luciferin oxidation, it will produce a light signal. The optical signal of this kit is a kind of instantaneous light, which needs to be detected immediately after adding the working solution. The half-life of optical signal is about 5 min.Instruction:1.Working fluid configuration ( 1 ) Restore all components to room temperature. ( 2 ) The component B ( stock solution ) was fully diluted with component A to prepare a 0.2 mg / mL firefly luciferase working solution, which was vortexed and shaken to ensure full mixing. Note : The firefly luciferase working solution cannot be repeatedly frozen and thawed. If the dosage of a single experiment is small, it is recommended to subpackage according to a single dosage. At room temperature, the activity decreased by about 10 % after the working solution was configured for 3 h, and the activity decreased by about 25 % after 5 h. 2.chemiluminescence value detection ( 1 ) The cell culture plate was taken out from the incubator and incubated at room temperature for 20 min to restore it to room temperature ( 22-25 ° C ). ( 2 ) Add the same volume of firefly luciferase working solution with the medium to the culture plate and mix well. ( 3 ) Incubation at room temperature for 5 min. Note : The incubation time can be adjusted according to cell type and cell number. ( 4 ) The values were read by multifunctional microplate reader or chemiluminescence instrument ( instrument parameters : the determination time was 10 s, the determination interval was 2 s ).Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. the strongest wavelength of bioluminescence catalyzed by firefly luciferase is 560 nm. 3. to prevent interference between holes, it is recommended to use white opaque orifice plate.Recommendation:Component B is recommended to use sterile water in advance to configure 2 mg / mL storage solution, A component and B component configured as storage solution, and small batch packaging according to the experimental requirements. The detection working fluid is recommended to be used now to avoid repeated freezing and thawing. Component:One-Step Firefly Luciferase Assay Buffer;D-Luciferin Scope of application:Mainly used for ADCC detection... Read More | This reagent kit uses highly sensitive silver dye, which can be applied to protein staining of denatured and non denatured gels. It has the advantages of clear target bands, low background, and flexible control of operation time. In addition, this reagent kit has added a short-term sensitization This reagent kit uses highly sensitive silver dye, which can be applied to protein staining of denatured and non denatured gels. It has the advantages of clear target bands, low background, and flexible control of operation time. In addition, this reagent kit has added a short-term sensitization step, which can significantly reduce the background and enhance the brightness of the target band. P665901Component20 TStorageP665901ASilver Stain Sensitizer (500×)2×1 mLRTP665901BSilver Stain Enhancer3 mLRTP665901CSilver Stain2×250 mLRTP665901DSilver Stain Developer4×125 mLRT Matters needing attention1. Please prepare 50 ml of fixed solution (ultrapure water: ethanol: acetic acid=6:3:1), 50 ml of eluent (10% ethanol), and 50 ml of termination solution (5% acetic acid) in advance.2. Please use deionized water and clean glass or plastic containers during operation, and wear disposable gloves for operation.The entire silver dyeing process needs to be carried out on a shaker, with a rotation speed of about 60 rpm.4. Self prepared ethanol and glacial acetic acid are required.Instructions for useThe dosage of each solution in the following operation steps takes the gel with a size of 8.5 × 5.5 cm and a thickness of 1.0 mm as an example. The gel is immersed in the solution completely, and is operated on a shaker, with a general dosage of 25 ml. For large gel, the dosage of each solution should be scaled up according to the gel volume. Please prepare 50 ml of fixed solution (ultrapure water: ethanol: glacial acetic acid=6:3:1), 50 ml of eluent (10% ethanol), and 50 ml of termination solution (5% glacial acetic acid) in advance.1. Water washing: After electrophoresis is completed, wash the gel twice with ultrapure water for 5 minutes each time.2. Fixation: Fix the gel twice with 25 ml of fixative solution for 15 minutes each time.3. Elution: Wash the adhesive twice with eluent, each time for 5 minutes.4. Water washing: Wash the glue twice with ultrapure water, each time for 5 minutes.5. Sensitization: put the gel washed in the previous step into the silver dye sensitization working solution, incubate it accurately for 1 minute at room temperature, and then wash it with ultrapure water for three times, each time for 20 seconds. Preparation of silver staining sensitization working solution: Take 50 µ l Silver Stain Sensitivity (500 x) and add it to 25 ml of ultrapure water, mix well.6. Silver staining: discard ultrapure water and incubate gel in silver staining working solution for 30 minutes. Preparation of silver staining working solution: Take 25ml Silver Stain and add 50 µ l Silver Stain Enhanced to mix well.7. Water washing: Quickly wash the glue twice with ultrapure water, with each washing accurately controlled for 20 seconds.8. Development: Immerse the washed gel in the developer immediately and incubate it at room temperature for 2-3 minutes until the protein strip is clear. Preparation of developer: Take 25ml Silver Stain Developer and add 30 µ l Silver Stain Enhanced to mix well. Attention: Within 30 seconds of development, protein bands begin to appear and continue to develop for 2-3 minutes. If the protein band appears lighter, the development time can be appropriately extended to 5 minutes or more.9. Termination: After washing the developer on the gel with the termination solution, soak the gel in a new termination solution to react for 10 minutes.Experimental imagesSilver staining results of BSA protein samples after 10% SDS-PAGE gel electrophoresisThe molecular weight of BSA protein is about 66 kD, and the loading amounts from left to right are 50 ng, 10 ng, and 5 ng, respectively... Read More | DescriptionMaterials included in the kit are designed to be used with the Hy-Energy′s PCTPro-2000 System. They also can be used for demonstration purposes and as standards during the development of novel hydrogen storage and battery materials |