| Description | Inquire | Products B669892Component50 TStorageB669892ABuffer RCL3×260 mL2-8℃B669892BBuffer GR25 mLRTB669892CBuffer GL25 mLRTB669892DBuffer GW1 (concentrate)13 mLRTB669892EBuffer GW2 (concentrate)15 mLRTB669892FBuffer GE15 mLRTB669892GProteinase K50 mgRTB669892HProteinase K Storage Buffer5 Products B669892Component50 TStorageB669892ABuffer RCL3×260 mL2-8℃B669892BBuffer GR25 mLRTB669892CBuffer GL25 mLRTB669892DBuffer GW1 (concentrate)13 mLRTB669892EBuffer GW2 (concentrate)15 mLRTB669892FBuffer GE15 mLRTB669892GProteinase K50 mgRTB669892HProteinase K Storage Buffer5 mLRTB669892ISpin Columns DL with Collection Tubes50 setsRTProductsThis kit is suitable for the extraction of total DNA, including genomic DNA, mitochondrial DNA and viral DNA, from fresh or frozen whole blood (blood samplestreated with anticoagulants such as citrate, EDTA or heparin), plasma, serum, haematocrit brown and yellow layers, bone marrow, cell-free body fluids, etc. Theproduct can process 1-5 ml of whole blood, and can be purified to obtain sizes rangingfrom 100bp to 50kb. The purified DNA is of high yield and good quality, with maximumremoval of proteins, pigments, lipids and other inhibitory impurities, and can bedirectly used in PCR, fluorescence quantitative PCR, enzyme digestion and SouthernBlot.Self-contained reagent: anhydrous ethanol.Pre-experiment Preparation and Important Notes1. Add 5ml Proteinase K Storage Buffer to Proteinase K to dissolve it, and storeit at -20℃. Do not leave the prepared Proteinase K at room temperature for a longtime, and avoid repeated freezing and thawing to avoid affecting its activity.2. Repeated freezing and thawing of the sample should be avoided, as this may resultin smaller DNA fragments and a decrease in the amount of extracted DNA. 3.This kit can extract up to 1-5 ml of whole blood samples, if you need to extracta large number of blood samples, please use the blood genome non-column extractionkit. 4. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to theinstructions on the label of the reagent bottle before first use.5. Please check Buffer GL for crystallization or precipitation before use, if thereis any crystallization or precipitation, please put it in 56℃water bath to re-dissolve.6. If the downstream experiments are sensitive to RNA contamination, 4µl of DNaseFree RNase A (100mg/ml) can be added, RNase A is not provided in the kit, and canbe ordered separately from our company if needed.7. The Buffer RCL in the kit cannot be used further after turbidity.procedure1. Add 1-5 ml of blood sample to a centrifuge tube (supplied) and add 3 times thevolume of Buffer RCL and gently vortex or invert to mix.2. Centrifuge at 3000 rpm (~900 x g) for 10 minutes and carefully aspirate thesupernatant.3. Add 400 µl Buffer GR to the precipitate and resuspend the precipitate. Note: If the downstream assay is sensitive to RNA, add 4 µl of RNase A (100 mg/ml)solution, shake for 15 seconds, and leave at room temperature for 5 minutes.4. For 1-2 ml blood sample extraction, add 40µl Proteinase K to the above solutionand mix well; for 2-5 ml blood sample extraction, add 100µl Proteinase K to theabove solution and mix well.5. Add 400 µl of Buffer GL, mix upside down 15 times, and vigorously vortex andshake for at least 1 minute. Note: Do not add Proteinase K directly to Buffer GL.6. Incubate at 70°C for 10 minutes, during which time mixing was inverted severaltimes.Note: 1) If the solution is not completely clear, add appropriate amount of Proteinase K and incubate. Extend the incubation time until the solution is completely clear. 2) The yield of DNA has been maximized by 10 minutes of incubation, and continuedprolongation of the incubation time has no effect on DNA yield or purity.7. Add 400 µl of anhydrous ethanol and mix upside down 10 times. Centrifuge brieflyto concentrate the liquid on the walls and cap to the bottom of the tube.8. Add all of the solution obtained in the previous step to the Spin Columns DL inthe collection tube. If the solution cannot be added all at once, transfer it severaltimes. centrifuge at 12,000 rpm (~13,400 x g) for 1 minute, pour off the waste liquidfrom the collection tube, and put the column back into the collection tube.9. Add 500 µl of Buffer GW1 to the adsorption column (check that anhydrous ethanolis added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquidin the collection tube, and put the adsorption column back into the collection tube.Note: It is recommended that step 9 be repeated if the sample being extracted isthe blood genome of a species such as mice or monkeys from which hemoglobin isdifficult to remove.10. Add 500 µl Buffer GW2 to the adsorption column (check that anhydrous ethanolis added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquidin the collection tube, and put the adsorption column back into the collection tube.Note: Step 10 can be repeated if further DNA purity is required.11. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in thecollection tube. Leave the adsorption column at room temperature for several minutesto dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorptioncolumn, which can interfere with subsequent enzymatic reactions (digestion, PCR,etc.)12. Place the adsorption column in a new centrifuge tube, add 50-200 µl of BufferGE or sterilized water to the middle of the adsorption column overhanging the column,leave it at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute,collect the DNA solution, and store the DNA at -20℃.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH of the eluent has a great influence on theelution efficiency, if water is used as the eluent should ensure that its pH is7.0-8.5 (you can use NaOH to adjust the pH of the water to this range), and the elutionefficiency is not high when the pH is lower than 7.0.2) Incubation at room temperature for 5 minutes prior to centrifugation increasesyield.3) Re-elution with an additional 50-200 µl Buffer GE or sterilized water can increase the yield.4) If the final concentration of DNA is to be increased, the DNA eluate obtainedin step 12 can be re-spiked onto the adsorbent membrane and centrifuged at 12,000rpm. 1min; if the elution volume is less than 200µl, the final concentration of DNA canbe increased, but the total yield may be reduced. If the amount of DNA is less than1 µg, elution with 50 µl Buffer GE or sterilized water is recommended.5) Because DNA preserved in water is subject to acidic hydrolysis, for long-termstorage, it is recommended that it be eluted with Buffer GE and stored at -20℃... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Inquire | V669947 Component 50T Storage V669947A Buffer GL 15 mL RT V669947B Buffer GW1 (concentrate) 13 mL RT V669947C Buffer GW2 (concentrate) 15 mL RT V669947D Buffer RE 10 mL RT V669947E Proteinase K 12.5 mg RT V669947F Proteinase K Storage Buffer 1.25 mL RT V669947G Spin Columns RS with Collection Tubes V669947 Component 50T Storage V669947A Buffer GL 15 mL RT V669947B Buffer GW1 (concentrate) 13 mL RT V669947C Buffer GW2 (concentrate) 15 mL RT V669947D Buffer RE 10 mL RT V669947E Proteinase K 12.5 mg RT V669947F Proteinase K Storage Buffer 1.25 mL RT V669947G Spin Columns RS with Collection Tubes 50 RT V669947H RNase-Free Centrifuge Tubes (1.5 mL) 50 RTProductsThis kit is suitable for the extraction of viral RNA and DNA from fresh or frozen plasma, serum and cell-free body fluids. It is easy to operate as it does not require the use of organic solvents such as phenol and chloroform for extraction. The kit uses a unique buffer system to enable efficient and specific binding of viral nucleic acids in lysate to silica gel centrifugal adsorption columns. Inhibitors of PCR and enzyme reactions as well as residual impurities can be efficiently removed in a two-step effective rinsing step, and finally high purity viral nucleic acids can be obtained by using a low-salt buffer or water for elution. The purified viral nucleic acid is free of protein, nuclease and other impurities, and can be used directly in PCR, RT-PCR, Real-Time PCR, blotting experiments and so on.Self-contained reagent: anhydrous ethanol.Pre-experiment and Important Notes1. Add 1.25ml Proteinase K Storage Buffer to Proteinase K to dissolve it and store it at -20℃. Do not leave the prepared Proteinase K at room temperature for a long time, and avoid repeated freezing and thawing to avoid affecting its activity. Do not add Proteinase K directly into Buffer GL.2. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller DNA fragments and a decrease in the amount of extracted DNA.3. Avoid repeated freezing and thawing of serum or plasma, which can lead to protein denaturation or precipitation, reducing the viral titer and thus affecting the yield of extracted viral nucleic acids.4. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the label instructions of the reagent bottle before first use.5. Check Buffer GL for crystallization or precipitation before use. If crystallization or precipitation occurs, redissolve Buffer GL in a water bath at 56℃.Procedure1. Take a 1.5 ml centrifuge tube (self-provided) and add 20 µl Proteinase K.2. Add 200 µl serum or plasma to the centrifuge tube. Add 200µl Buffer GL and vortex and shake for 15 seconds.Note: 1) Sample volume less than 200 µl can be made up by adding 0.9% NaCl (self-provided). 2) In order to ensure effective lysis of the sample, the sample needs to be mixed well with Buffer GL after adding Buffer GL.3. Incubate at 56°C for 15 minutes, centrifuge briefly, and collect the solution from the wall of the tube to the bottom of the tube.4. 250 µl of anhydrous ethanol was added, vortexed and shaken for 15 seconds, left at room temperature for 5 minutes, centrifuged briefly, and the solution on the wall of the tube was collected at the bottom of the tube.Note: If the ambient temperature exceeds 25°C, anhydrous ethanol should be used after pre-cooling on ice.5. Add the solution obtained in step 4 to the adsorbent column (RNase-Free Columns RS) that has been loaded into the collection tube, and if the solution cannot be added at one time, it can be transferred in several times. centrifuge the column at 12,000 rpm (~13,400 × g) for 1 min, pour off the waste liquid in the collection tube, and put the column back into the collection tube.6. Add 500 µl of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.7. Add 500 µl of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Add 500 µl of anhydrous ethanol to the adsorbent column and centrifuge at 12,000 rpm for 1 min. Pour off the waste liquid in the collection tube and put the adsorbent column back into the collection tube.9. Centrifuge at 12,000 rpm for 3 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is the removal of residual ethanol from the adsorbent column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).10. Place the adsorption column in a new collection tube (RNase-Free Centrifuge Tube), add 20-150 µl of Buffer RE or sterilized water overhanging the middle of the adsorption column membrane, leave it at room temperature for 2-5 minutes, and then centrifuge it at 12,000 rpm for 1 minute to collect the nucleic acid solution.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH of the eluent has a great influence on the elution efficiency, if water is used as the eluent it should be ensured that its pH is 7.0-8.5 (the pH of water can be adjusted to this range with NaOH), and the elution efficiency is not high when the pH is lower than 7.0.(2) For long-term storage, please store the DNA solution at -20℃ and the RNA solution at -70℃.3) If the final concentration of DNA/RNA is to be increased, the DNA/RNA eluate obtained in step 10 can be re-spiked onto the adsorbent membrane and step 10 repeated... Read More |