| Description | Inquire | This reagent kit is suitable for simultaneously isolating and purifying genomic DNA, total RNA, and total protein from the same cell or tissue sample. This product does not require dividing the sample into three parts to extract DNA, RNA, and protein separately, nor does it require dividing the This reagent kit is suitable for simultaneously isolating and purifying genomic DNA, total RNA, and total protein from the same cell or tissue sample. This product does not require dividing the sample into three parts to extract DNA, RNA, and protein separately, nor does it require dividing the purified total nucleic acid into two parts before purifying DNA and RNA separately. Therefore, it can maximize the recovery of DNA, RNA, and protein, and can be used for the purification of nucleic acid and protein in small and rare samples. The purified DNA, RNA, and protein can be eluted separately and directly applied to various downstream molecular biology operations. This reagent kit does not contain toxic substances such as phenol and chloroform, and does not require ethanol precipitation. The operation is simple and fast. The extracted genomic DNA can be used for PCR, Real time PCR, SouthBlot, Dot Blot, comparative genomic hybridization (CGH), gene analysis, and SNP analysis; Total RNA can be applied in experiments such as RT-PCR, cDNA synthesis, Northern Blot, Dot Blot, and gene chips; Total protein can be applied in electrophoresis and Western Blot, among others. A665492 Component 50 T Storage A665492A Buffer RL 35 mL RT A665492B Buffer RW1 40 mL RT A665492C Buffer RW2 (concentrate) 11 mL RT A665492D RNase-Free Water 10 mL RT A665492E Buffer GW1 (concentrate) 13 mL RT A665492F Buffer GW2 (concentrate) 15 mL RT A665492G Buffer GE 15 mL RT A665492H Buffer PZ 60 mL RT A665492I Buffer PLS 15 mL RT A665492J Spin Columns DM with Collection Tubes 50 sets RT A665492K Spin Columns RM with Collection Tubes 50 sets RT A665492L Collection Tubes 100 EA RT A665492M RNase-Free Centrifuge Tubes (1.5 mL) 100 EA RTSelf prepared reagents:β- Mercaptoethanol (for newly opened or RNA extraction), 70% ethanol (prepared with water without RNase), and anhydrous ethanol.Preparation and important precautions before the experiment:To prevent RNase pollution, attention should be paid to the following aspects:1) Use plastic products and gun heads without RNase to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) The solution should be prepared using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The sample should avoid repeated freeze-thaw cycles, otherwise it will affect the quality of DNA, RNA, and protein extraction. The sample can be stored in Buffer RL at -70 ℃ for one month.3. Please add Buffer RL before use β- Mercaptoethanol, 1 ml Buffer RL with 10 µ L β- Mercaptoethanol. join β- The buffer RL room temperature of mercaptoethanol can be stored for one month.Before the first use, anhydrous ethanol should be added to Buffer RW2, Buffer GW1, and Buffer GW2 according to the instructions on the reagent bottle label.5. Before use, please check if there is any crystallization or precipitation in the Buffer RL. If there is any crystallization or precipitation, please dissolve it again in a 56 ℃ water bath.6. All centrifugation steps are performed using a desktop centrifuge at room temperature. Operation steps:1. Material processing1a The cells cultured on the wall should be first processed into cell suspension (maximum extraction amount of 107 cells), collected cells, discarded the culture medium, and added 600 cells µ L Buffer RL (check if it has been added before use) β- Mercaptoethanol), repeatedly blow and beat to fully decompose.Attention: It is necessary to discard the culture medium completely, otherwise it will affect the lysis and subsequent nucleic acid purification steps.1b Take no more than 30 mg of animal tissue, grind it into fine powder with liquid nitrogen, and add 600 µ Buffer RL (check if it has been added before use) β- Mercaptoethanol, or directly add 600 µ L Buffer RL (check if it has been added before use) β- Mercaptoethanol, homogenization treatment.Attention: The homogenate should be sufficient, otherwise it will affect RNA production.2. Centrifuge the solution obtained in the previous step at 12000 rpm (~13400 × g) for 3-5 minutes. Carefully add the supernatant to the spin columns DM that have been loaded into the collection tube. Centrifuge at 12000 rpm for 30-60 seconds and collect the filtrate. Place the adsorption column DM in a new 2 ml collection tube at room temperature or 4 ℃ for DNA extraction. Attention: Ensure that there is no liquid residue on the adsorption column, and if necessary, repeat centrifugation until all liquids pass through the membrane of the adsorption column. Total RNA extraction3. Add 1 volume of 70% ethanol (prepared without RNase water) to the filtrate obtained in step 2, and mix well.4. Add all the solution obtained in the previous step to the spin columns RM that have been loaded into the collection tube. If the solution cannot be added completely at once, it can be transferred in stages. Centrifuge at 12000 rpm for 20 seconds and retain the liquid in the collection tube for protein extraction.5. Place the adsorption column RM into a new 2ml collection tube and add 700 to the adsorption column RM µ L Buffer RW1, centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM into the recovery manifold.6. Add 500 to the adsorption column RM µ Buffer RW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM back into the 2 ml collection tube.7. Repeat step 6.Centrifuge at 8.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Attention: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).9. Place the adsorption column RM in a new 1.5 ml centrifuge tube without RNase, and add 30-50 to the middle of the adsorption column RM µ Place RNase Free Water at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 9 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 9.Genomic DNA extraction10. Add 500 to the adsorption column DM µ Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column DM into the recovery tube.11. Add 500 to the adsorption column DM µ Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column DM into the recovery tube. Attention: To further improve DNA purity, repeat step 11.Centrifuge at 12.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column DM at room temperature for a few minutes to thoroughly dry the ethanol in the column. Attention: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).13. Place the adsorption column DM in a new centrifuge tube and add 100 to the middle of the adsorption column DM by suspending it in the air µ L Buffer GE, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 2 minutes, collect DNA solution, and store DNA at -20 ℃.Attention:1) The volume of Buffer GE should not be less than 100 µ l. Small volume affects the recovery rate.2) If we want to increase DNA production, we will µ Add a new Buffer GE to the adsorption column and repeat step 13; If you want to increase the DNA concentration, you can add the DNA eluent obtained in step 13 back onto the adsorption column and repeat step 13.Protein extraction14. Add 1 volume of Buffer PZ to the RNA extraction effluent (i.e. the solution obtained in step 4), mix well, and let it stand at room temperature for 10-30 minutes.Centrifuge at 15.12000 rpm for 10 minutes and discard the supernatant.16. Add 500 µ Centrifuge at 12000 rpm for 1 minute with 70% ethanol, and try to absorb the supernatant as much as possible.17. Place the centrifuge tube at room temperature for a few minutes to dry the precipitate.Attention: The purpose of this step is to remove residual ethanol. Excessive drying can make protein precipitation difficult to dissolve, and incomplete drying of residual ethanol can affect protein loading.18. Add 100 µ L Buffer PLS to obtain protein solution.Attention:1) The protein samples obtained by dissolving with Buffer PLS are suitable for SDS-PAGE and Western Blot detection, but not for Bradford method for protein quantification. If Bradford method is needed for protein quantification, 5% SDS can be used to dissolve the protein, or suitable protein dissolution buffer can be selected based on downstream experiments.2) The amount of dissolved protein buffer added is determined based on the initial sample size and specific downstream test requirements.3) The dissolved protein can be stored at -20 ℃ for several months and at 2-8 ℃ for several days.If protein samples require SDS-PAGE electrophoresis, the following operations can be performed:19. Add protein loading buffer to the protein sample, denature at 95 ℃ for 5-10 minutes, and cool the sample to room temperature. Centrifuge at 20.12000 rpm for 1 minute, extract the supernatant for downstream SDS-PAGE or Western blot tests... Read More | Alanine Aminotransferase (ALT), also known as serum glutamic-pyruvic transaminase (SGPT), is a pyridoxal-phosphate-dependent enzyme that catalyzes the reversible transfer of an amino group from alanine to α-ketoglutarate, generating pyruvate and glutamate. ALT is found primarily in liver and Alanine Aminotransferase (ALT), also known as serum glutamic-pyruvic transaminase (SGPT), is a pyridoxal-phosphate-dependent enzyme that catalyzes the reversible transfer of an amino group from alanine to α-ketoglutarate, generating pyruvate and glutamate. ALT is found primarily in liver and serum, but occurs in other tissues as well. Hepatocellular injury often results in an increase of serum ALT levels and serum ALT levels can be used as a marker for liver injury.ALT Activity Assay kit has been used to determine the activity of alanine aminotransferase (ALT) in serum samples... Read More | Bacterial protein extraction reagents use mild non-ionic detergents and are suitable for extracting recombinant proteins expressed in Escherichia coli and insect cells. During the extraction process, there is no need for ultrasonic fragmentation, effectively avoiding contamination of exogenous Bacterial protein extraction reagents use mild non-ionic detergents and are suitable for extracting recombinant proteins expressed in Escherichia coli and insect cells. During the extraction process, there is no need for ultrasonic fragmentation, effectively avoiding contamination of exogenous proteins. This product can be applied to extract soluble proteins from bacterial lysates. The bacterial protein extraction kit adds a mixture of lysozyme, DNase I, and protease inhibitors to the extraction reagent, which can improve the efficiency of protein extraction and reduce the viscosity caused by DNA, effectively avoiding protein degradation. The extracted protein maintains biological activity and can be subjected to downstream operations such as IP, Western blot, and protein purification. Component B665764 100 preps Bacterial Protein Extraction Reagent 100 ml Protease Inhibitor Cocktail (100x) 1 ml Lysozyme (50 mg/ml) 200µl DNaseⅠ(1,000 U/ml) 100µl Notes:1. This product is suitable for extracting proteins from fresh or frozen bacterial and insect cells.2. This product uses Tris buffer system. Please use the same buffer system for protein purification after extraction.3. The protein lysis solution obtained from this product can be used for protein quantification using BCA or Bradford method.4. For special strains, if the extraction effect is not ideal, the sample can be frozen before protein extraction.5. Depending on the specific situation, protease inhibitors, salts, chelating agents, reducing agents, etc. can be added to this product.Operation steps: ● Insect cell protein extraction1. Collect cells by low-speed centrifugation. Add 10 to every 1 ml of Bacterial Protein Extraction Agent µ The Protein Inhibitor Cocktail is 1 x working fluid.2. Weigh the wet weight of the cells and add 1 x working solution at a rate of 10 ml/g.3. After resuspension, incubate on ice for 20 minutes (the ice storage time should be adjusted according to different cell types).Centrifuge at 4.15000 × g for 15 minutes to isolate soluble proteins. ● Extraction of soluble bacterial proteins 1. Centrifuge for 10 minutes at a rate of 5000 × g and collect the bacterial cells.2. Optional steps: Add 1 ml of Bacterial Protein Extraction Reagent every 1 ml µ DNase I (1000 U/ml), 2 µ Lysozyme (50 mg/ml) and 10 µ Protein Inhibitor Cocktail, vortex oscillation and mixing. 3. Add 20 ml of Bacterial Protein Extraction Reagent to each gram of bacterial precipitate, and add the extraction solution to the bacterial precipitate. Vortex thoroughly or use a pipette to blow up and down until the bacterial precipitate is completely resuspended.4. After resuspension, incubate at room temperature for 10-15 minutes (the storage time should be adjusted according to different cell types). 5. Centrifuge at 15000 × g for 5 minutes.6. Transfer the supernatant to a new centrifuge tube (the supernatant is soluble protein) for protein quantification and downstream experiments.Note: If the target protein exists in the form of inclusion bodies, inclusion body protein solution can be used for dissolution or expression conditions can be optimized to increase the expression of soluble proteins.Frequently asked questions: Problem Possible reasons Resolvent The target protein is insoluble The target protein is expressed as an inclusion body Optimize expression conditions or add Lysozyme and DNase I to protein extraction reagents using inclusion body protein solution After adding Lysozyme, the target protein has not been extracted yet Temperature too low Restore the reagent to room temperature After adding Lysozyme, the target protein has not been extracted yet Lysozyme Decreased or inactivated activity Add more Lysozymes or replace with new enzymes Extract has high viscosity DNase I Decreased or inactivated activity Add more DNase I or replace with a new DNase I to increase the final concentration of magnesium ions to 2 mM After protein extraction, most of the proteins still exist in the precipitate Excessive protein content Add Lysozyme and DNase I The protein extraction reagent has sediment precipitation Temperature too low Restore the protein extraction reagent to room temperature... Read More | Product content Q665687Component100 TStorageQ665687AQuick T4 DNA Ligase (15 U/µL)100 µL-20℃. Avoid freeze/thaw cycle.Q665687B2×Quick Ligation Reaction Buffer5×200 µL-20℃. Avoid freeze/thaw cycle. Product IntroductionThe Quick Ligation Reaction Kit allows ligationProduct content Q665687Component100 TStorageQ665687AQuick T4 DNA Ligase (15 U/µL)100 µL-20℃. Avoid freeze/thaw cycle.Q665687B2×Quick Ligation Reaction Buffer5×200 µL-20℃. Avoid freeze/thaw cycle. Product IntroductionThe Quick Ligation Reaction Kit allows ligation of DNA sticky or flush ends in 5 minutes at room temperature (25°C). The kit contains Quick T4 DNA Ligase and 2×Quick Ligation Reaction Buffer optimized for fast and efficient DNA ligation.The ligation efficiency of Quick Ligation is equivalent to 1 hour of conventional ligation with T4 DNA Ligase. The Quick Ligation products can be used directly in routine bacterial transformation experiments.matters needing attention1. This kit enables most of the linkage reactions to reach the reaction endpoint within 5 minutes or less at 25°C. Increasing the reaction time will not enhance the reaction efficiency. If you use the rapid connection reaction after 1 hour, the conversion efficiency will be significantly reduced; if the rapid connection reaction at 25 ℃ overnight, the conversion efficiency will drop to 75%.2. 2×Quick Ligation Reaction Buffer contains ATP, which should be thawed on ice and mixed thoroughly before use. It is recommended to freeze the buffer in small tubes for the first time, so as to avoid repeated freezing and thawing, which will affect the efficiency of DNA ligation.3. Since T4 DNA Ligase contains glycerol, which is sticky and easy to hang on the wall, it is recommended to collect the liquid to the bottom of the tube by centrifugation for a short period of time before use, and the tip of the lance should not go too deep into the liquid surface when taking samples to avoid sticking to the tip of the lance and causing losses.4. If the quick ligation product is used for electrotransformation, the PEG in the quick ligation reaction system will affect the efficiency of electrotransformation, and it is recommended to use a centrifugal column to purify the ligation product from DNA before electrotransformation.Usage1. The reaction solution was prepared according to the following system:*The amount of Insert DNA used: the molar ratio of Vector DNA and Insert DNA is generally 1:3-1:8, and the appropriate molar ratio of Vector DNA and Insert DNA can be selected according to the experimental situation.Calculation of DNA molar number: DNA molar number (nmol)=DNA mass (ng)/( 660daltons x number of inserted DNA bases bp).2. mix gently and centrifuge briefly. react at 25°C for 5 minutes.Note: The reaction time should not exceed 15 minutes, otherwise the connection efficiency will be reduced.3. Do not perform heat inactivation reactions. Centrifuge instantly and collect the solution from the wall to the bottom of the tube.Note: Heat inactivation significantly reduces transformation efficiency due to the presence of PEG in the buffer.4. After the reaction, store the DNA ligation product at 0-4℃, and then carry out transformation experiments; you can also store the DNA ligation product at -20℃.Note: When transforming by chemical method, do not add more than 10% of the volume of the receptor cell for the ligation product.5. Heat shock the ligation product to transform 50 µl of receptor cells or take 1-2 µl of ligation product to electroshock transform 50 µl of receptor cells.Note: 1) When transforming by chemical method, do not add more than 10% of the volume of the receptor cell for the ligation product.(2) If the quick ligation product is used for electrotransformation, it is recommended to use a centrifugal column to purify the ligation product from DNA before electrotransformation because the PEG in the quick ligation reaction system will affect the efficiency of electrotransformation... Read More |