| Description | Inquire | FFPE DNA/RNA KitFixed Tissue DNA/RNA Extraction Kit Catalog number: F666120 (50 preps)Storage conditions: DNase I and 10×Reaction Buffer -20℃, Spin Columns DF and Spin Columns RS can be stored at room temperature for 2 months, 2-8℃ for 1 year, the rest of the components are stored FFPE DNA/RNA KitFixed Tissue DNA/RNA Extraction Kit Catalog number: F666120 (50 preps)Storage conditions: DNase I and 10×Reaction Buffer -20℃, Spin Columns DF and Spin Columns RS can be stored at room temperature for 2 months, 2-8℃ for 1 year, the rest of the components are stored at room temperature (15-30℃).Products Content:Products IntroductionThis kit is suitable for the effective purification of genomic DNA and total RNA from paraffin-embedded tissues, using specially optimized deparaffinizing agents and lysates to release DNA and RNA from tissue section samples, without the use of the organic reagent xylene, and without the need for overnight operation; the digested samples are incubated at higher temperatures to remove inhibitors caused by cross-linking, which can effectively improve nucleic acid yields and purity; and an optimized buffer system allows nucleic acids in the lysate to bind specifically to the adsorbent membrane, and inhibitors are effectively removed by a two-step rinsing procedure. The optimized buffer system enables the nucleic acids in the lysate to bind specifically to the adsorbent membrane, and the inhibitors are effectively removed by a two-step rinsing step, and finally eluted with low-salt buffer or water to obtain high purity DNA and RNA, and at the same time, equipped with a high-efficiency microsorbent column, the volume of the elution can be as low as 20 µl. The purified DNA and RNA can be directly used for PCR, Real-time PCR, SNP genotyping, STR genotyping, and so on. The purified DNA and RNA can be directly used for PCR, Real-time PCR, SNP genotyping, STR genotyping, second-generation sequencing, pharmacogenomics research and blot analysis.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes 1. After obtaining the sample, fix the sample as soon as possible, the fixation time of 14-24 hours is appropriate, too long a period of time will easily lead toDNA and RNA breaks, affecting downstream experiments. If the formaldehyde fixation time is too long or the sample is stored for too long(>1 year) is prone to compromise DNA integrity and failure to amplify long fragments.2. Ensure that samples are thoroughly dehydrated prior to embedding; residual formalin will inhibit Proteinase K action.3. Add 1.25 ml of Proteinase K Storage Buffer to Proteinase K to dissolve it, and store at -20℃. Do not leave the prepared Proteinase K at room temperature for a long period of time to avoid affecting its activity.4. Anhydrous ethanol should be added to Buffer RW2, Buffer GW1 and Buffer GW2 according to the label instructions on the vials before first use.5. Check Buffer GTL, Buffer GL and Buffer DS for crystallization or precipitation prior to use; if crystallization or precipitation occurs, redissolve Buffer GTL, Buffer GL and Buffer DS in a 37°C water bath.6. Preheat the water bath or thermostatic mixer to 56°C before starting the experiment.7. Use an ambient temperature centrifuge or set the centrifuge temperature to 25°C. Temperatures below 15°C may result in clogging of the adsorption column.8. To prevent RNase contamination, the following should be observed:1) Use RNase-free plastics and tips to avoid cross-contamination.(2) Glassware should be dry baked at 180°C for 4 hours before use, plasticware can be soaked in 0.5 M NaOH for 10 minutes, rinsed thoroughly with water and autoclaved.3) RNase-free water should be used to prepare the solution.(4) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.procedureParaffin-embedded samples1. Trim off excess paraffin from the tissue block to expose the tissue and cut into 5-10 µm slices.2. Place approximately 1 x 1 cm2 slices (1-5 slices in total) in a centrifuge tube (supplied), add 500 µl of Buffer DS and vortex for 10 s. Briefly centrifuge the sample to the bottom of the tube. Centrifuge briefly to collect the sample at the bottom of the tube, incubate at 56°C for 3 minutes, remove from the water bath and allow to cool to room temperature before proceeding.Note: If the surface of the sample is exposed to air, discard the initial 2-3 slices without using them.3. Centrifuge at 12,000 rpm for 2 minutes and carefully discard the supernatant thoroughly without aspirating the precipitate. The residual dewaxing solution can be carefully removed with a small tip (10 µl).4. Add 180 µl of Buffer GTL and 20 µl of Proteinase K to the above tube and mix well with vortexing.5. Incubate at 56°C for 15 minutes, then place on ice for 3 minutes. Centrifuge at 12,000 rpm for 15 minutes at room temperature.6. Transfer the supernatant to a new 1.5 ml centrifuge tube for RNA extraction, taking care not to aspirate undigested tissue. Use the precipitate for DNA extraction. RNA extraction7. Take the supernatant obtained in step 6 and incubate at 80°C for 15 minutes.8. Add 320 µl of Buffer GL, mix by vortexing and shaking, then add 720 µl of anhydrous ethanol and mix immediately by vortexing and shaking.9. Add all of the resulting solution to the Spin Columns RS in the collection tube; if the solution cannot be added all at once, it may be transferred in several passes. centrifuge the column at 12,000 rpm for 1 minute, pour off the waste solution from the collection tube, and place the column back into the collection tube. Note: If the columns are clogged, the sample size may be too large and consideration should be given to reducing the number of starting sections to 1-2.Optional step: If genomic DNA is to be removed, the following steps can be followeda. Add 350 µl of Buffer RW1 to the column, centrifuge at 12,000 rpm for 1 minute, discard the waste solution, and place the column back into the collection tube.b. Preparation of DNase I mixture: Take 52 µl of RNase-Free Water and add 8 µl of 10×Reaction to it.Buffer and 20 µl DNase I (1 U/µl), mix well, and prepare a final volume of 80 µl of reaction solution.c. Add 80 µl of DNase I Mix directly to the adsorption column and incubate at 20-30°C for 15 minutes.d. Add 350 µl of Buffer RW1 to the column, centrifuge at 12,000 rpm for 1 minute, discard the waste solution, and return the column to the collection tube.Add 500 µl of Buffer RW2 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.11. Repeat step 10. centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Place the column at room temperature for 5 minutes.minutes to dry thoroughly.12. Place the column in a new RNase-free centrifuge tube and add 20-50 µl to the center of the column.RNase-Free Water, left at room temperature for 5 minutes, centrifuged at 12,000 rpm for 1 minute, and collected RNA solution, the-80°C for storage.DNA extraction7. Take the precipitate obtained in step 6 and add 180 µl Buffer GTL and 20 µl Proteinase K to the precipitate. VortexResuspend the precipitate for 15 seconds.8. Incubate at 56°C for 1 hour until the sample is completely dissolved. 90°C for 1 hour.Add 200 µl Buffer GL, vortex and shake to mix and then add 200 µl anhydrous ethanol, vortex and shake to mix thoroughly. Centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube. Add all of the solution from step 9 to the Spin Columns DF in the collection tube, or transfer the solution in several passes. centrifuge at 12,000 rpm for 1 minute, pour off the waste solution from the collection tube, and return the column to the 10. collection tube.Note: If the adsorption column is clogged, the sample size may be too large and consideration should be given to reducing the number of starting sections to 1-2.11. Add 500 µl of Buffer GW1 to the adsorbent column and centrifuge at 12,000 rpm for 1 minute. Pour off the waste liquid from the collection tube and put the column back into the collection tube.12. Add 500 µl of Buffer GW2 to the adsorbent column and centrifuge at 12,000 rpm for 1 minute. Pour off the waste liquid from the collection tube and place the column back into the collection tube.Note: Step 12 may be repeated if further purity is required.13. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for 5 minutes to dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorbent column; ethanol residue will affect the subsequent enzymatic reaction. 14. Place the column in a new 1.5 ml centrifuge tube, add 20-50 µl Buffer EB to the center of the column, leave at room temperature for 5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store at -20℃... Read More | H665581 Component 100 T Storage H665581A gDNA Eraser 50 µL -20℃. Avoid freeze/thaw cycle. H665581B 10×gDNA Eraser Buffer 120 µL -20℃. Avoid freeze/thaw cycle. H665581C HiFiScript, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. H665581D 5×ScriptRT H665581 Component 100 T Storage H665581A gDNA Eraser 50 µL -20℃. Avoid freeze/thaw cycle. H665581B 10×gDNA Eraser Buffer 120 µL -20℃. Avoid freeze/thaw cycle. H665581C HiFiScript, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. H665581D 5×ScriptRT Buffer 500 µL -20℃. Avoid freeze/thaw cycle. H665581E Primer Mix 120 µL -20℃. Avoid freeze/thaw cycle. H665581F RNase-Free Water 2×1 mL -20℃. Avoid freeze/thaw cycle.Product IntroductionThis product is a kit for removing genomic DNA for reverse transcription. The kit removes genomic DNA in 2 minutes at 42°C. Since the reverse transcription reagent contains a component that inhibits gDNA Eraser, cDNA can be synthesized directly by reverse transcription of gDNA Eraser-treated samples.The kit is equipped with a new high-efficiency reverse transcription enzyme, HiFiScript, with novel mutation sites that dramatically increase the transcriptional activity of the enzyme, resulting in higher efficiency and yield of cDNA first-strand synthesis. The first strand of cDNA can be synthesized with higher efficiency and yield, and the first strand of cDNA can be synthesized from pg total RNA or mRNA. If the reverse transcription product cDNA is used for downstream fluorescence quantitative detection, the reverse transcription reaction can be completed at 42℃ in 15 minutes. This kit is suitable for the synthesis of first-strand cDNA and subsequent RT-PCR, RT-qPCR, and the construction of full-length cDNA libraries.Product Features1. Rapid genome removal: contains gDNA Eraser for genomic DNA removal, which removes genomic DNA in just 2 minutes.2. Rapid reverse transcription: 15 minutes to obtain fluorescent quantitative PCR template cDNA first strand synthesis.3. High sensitivity: cDNA first strand can be synthesized using pg-level total RNA or mRNA templates.4. Highly efficient reverse transcription: Novel mutation sites dramatically increase enzyme activity, resulting in higher yields of cDNA.matters needing attention1. During operation, RNase contamination should be avoided to prevent RNA degradation or cross-contamination in the experiment. It is recommended that operators wear masks and disposable gloves and change the gloves frequently, and use specialized instruments and consumables.2. The reverse transcription system is prepared and operated on ice to prevent degradation of RNA. Store the kit enzymes at -20ºC as soon as possible after use and try to avoid repeated freezing and thawing.3. The reaction system can be scaled up to a maximum of 1 µg of total RNA in 10 µl of reaction system.4. Primer Mix is prepared by Oligo(dT) and Random primer, and Oligo-dT Primer or Gene Specific Primer can also be used according to the experimental needs.5. If the amount of starting RNA is less than 50ng, it is recommended to add RNAase inhibitor (RNasin).6. For RNA templates with complex secondary structures, it is recommended to incubate the template RNA at 65°C for 5 minutes immediately on ice prior to the manipulation step and centrifuge briefly before proceeding to the next step.UsageThaw template RNA on ice; place kit components on ice immediately after thawing at room temperature. Each solution was mixed by vortexing and shaking before use and briefly centrifuged.I. Genomic DNA removal reactions1. Prepare the reaction system according to the following table on ice in a total volume of 10 µl. To ensure the accuracy of the reaction solution preparation, prepare the premixed system in the amount of reaction number + 2 before dispensing it into each reaction tube and finally adding the RNA sample.Note: 1) If the amount of total RNA is greater than 1µg, scale up the reaction system proportionally. If the amount of starting RNA is less than 50ng, it is recommended to add RNAase inhibitor (RNasin).2. Mix by vortex shaking and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.3. Incubate at 42°C for 2 minutes (this can be extended to 30 minutes for room temperature reactions).4.At the end of the reaction, centrifuge briefly and place on ice to cool.II. Reverse transcription reaction1. Prepare the reaction system on ice according to the following table. In order to ensure the accuracy of the reaction solution configuration, first prepare a premixed solution in the amount of number + 2, and then dispense 10 µl into each reaction tube, take 10 µl of the prepared premixed solution and add it to the reaction tube of step 1 where the de-etching of the genome has been completed.Note: 1) Oligo-dT Primer or Gene Specific Primer can be used according to the needs of the experiment, it is recommended to use 50 pmol of Oligo-dT Primer or 2 pmol of Gene Specific Primer for 20 µl reaction system.2. Mix well and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.3. cDNA synthesis reaction conditions:1) If fluorescent quantitative PCR assay is performed downstream, incubate at 42°C for 15 minutes and 85°C for 5 minutes.2) If downstream for normal PCR assay, incubate at 42°C for 30-50 minutes and 85°C for 5 minutes. Note: For templates with complex secondary structure or high GC content, the reverse transcription temperature can be increased to 50°C to enhance reverse transcription efficiency.4. At the end of the reaction, centrifuge briefly and place on ice before proceeding with subsequent PCR or fluorescence quantitative PCR, or place at -20°C if prolonged storage is required.Note: When performing Real-time PCR reactions, the amount of reverse transcription product added should not exceed 1/10 of the total volume of the PCR reaction... Read More | Product contentN666081Component50 TStorageN666081ANc-Buffer A50 mL2-8℃N666081BNc-Buffer B3 mL2-8℃N666081CNc-Buffer C25 mL2-8℃N666081DProtease Inhibitor Cocktail750 µL-20℃. Avoid freeze/thaw cycle.ProductsThe Nc-Nucleus/Plasma Protein Extraction Kit is a simple and rapid Product contentN666081Component50 TStorageN666081ANc-Buffer A50 mL2-8℃N666081BNc-Buffer B3 mL2-8℃N666081CNc-Buffer C25 mL2-8℃N666081DProtease Inhibitor Cocktail750 µL-20℃. Avoid freeze/thaw cycle.ProductsThe Nc-Nucleus/Plasma Protein Extraction Kit is a simple and rapid method for extracting nucleus and plasma proteins from mammalian cells and tissues, and the extracted proteins remain biologically active. The kit first cleaves the cell membrane and releases plasma proteins using the plasma protein extraction reagent, and then centrifuges the nucleus to obtain a nucleus precipitate. Finally, the nuclear proteins are extracted by the nuclear protein extraction reagent. The extracted nuclear and plasma proteins are of high purity, effectively avoiding cross-contamination of nuclear and plasma proteins, and can be used for subsequent operations such as Western, Gel Shift, reporter gene detection and enzyme activity determination.Caveat1. If phosphorylated proteins are to be extracted, add a phosphatase inhibitor to the extraction reagent.2. All sample handling should be done on ice.3. The amount of reagents can be adjusted according to the specific experimental situation to ensure that the ratio of each reagent used is Nc-Buffer A:Nc-Buffer B:Nc-Buffer C = 100:5.5:50.4. Higher speeds can be used for centrifugation.ProcedureI Extraction of cytoplasmic and cytosolic proteins from cells1. Please remove the extraction reagents Nc-Buffer A and Nc-Buffer C for pre-cooling before protein extraction.2. Collect the cells and count them. Centrifuge to remove supernatant.3. 1×107 cells were added with 1 ml of Nc-Buffer A (added to Protease Inhibitor Cocktail at a ratio of 1:99 within 2-3 minutes prior to protein pumping), vortexed for 5 seconds to mix well, and incubated on ice for 20 minutes.Note: The characteristics of various cells are different, and the amount of Nc-Buffer A needs to be adjusted according to the characteristics of different cells. If the protein concentration is small, reduce the amount of Nc-Buffer A and subsequent Nc-Buffer B and Nc-Buffer C proportionally.4. Add 55 µl of Nc-Buffer B, vortex for 5 seconds to mix thoroughly, and incubate on ice for 1 minute.5. Centrifuge at 12,000 rpm (~13,400 x g) for 15 minutes at 4°C, collect the supernatant (as clean as possible) into a new centrifuge tube and store at -20°C (this extract is cytoplasmic protein).6. Add 500 µl of Nc-Buffer C (add Protease Inhibitor Cocktail at a ratio of 1:99 before use) to the precipitate obtained in the previous step, vortex for 5 seconds to mix thoroughly, resuspend the precipitate and incubate on ice for 40 minutes, vortexing and mixing at 10-minute intervals for about 15-30 seconds each time.7. Centrifuge at 12,000 rpm for 15 minutes at 4°C, collect the supernatant (as clean as possible) into a new centrifuge tube and store at -20°C (this extract is for cytosolic proteins).II Extraction of cytoplasmic and cytosolic proteins from tissues1. Sampling and preservation of tissues.2. Remove the extraction reagents Nc-Buffer A and Nc-Buffer C for pre-cooling before protein extraction.3. Weigh the tissue and add 1 ml of Nc-Buffer A per 100 mg of tissue (add Protease Inhibitor Cocktail 2-3 minutes before protein extraction at a ratio of 1:99), homogenize well on ice with a homogenizer, and incubate on ice for 20 minutes.Note: The characteristics of various tissues are different, and the amount of Nc-Buffer A needs to be adjusted according to different tissues. If the protein concentration is small, reduce the amount of Nc-Buffer A and subsequent Nc-Buffer B and Nc-Buffer C proportionally.4. Add 55 µl of Nc-Buffer B, vortex for 5 seconds to mix thoroughly, and place on ice for 1 minute of incubation.5. Centrifuge at 12,000 rpm for 15 minutes at 4°C, collect the supernatant (as clean as possible) into a new centrifuge tube and store at -20°C (this extract is cytoplasmic protein).6. Add 500 µl of Nc-Buffer C (add Protease Inhibitor Cocktail at a ratio of 1:99 before use) to the precipitate obtained in the previous step, vortex for 5 seconds to mix thoroughly, resuspend the precipitate and incubate on ice for 40 minutes, vortexing and mixing at 10-minute intervals at, each time for about 15-30 seconds.7. Centrifuge at 12,000 rpm for 15 minutes at 4°C, collect the supernatant (as clean as possible) into a new centrifuge tube and store at -20°C (this extract is cytosolic protein)... Read More | Product contentS665868Component50 TStorageS665868ABuffer GL25 mLRTS665868BBuffer GW1 (concentrate)13 mLRTS665868CBuffer GW2 (concentrate)15 mLRTS665868DBuffer GE15 mLRTS665868EProteinase K2×1.25 mLRTS665868FSpin Columns DM with Collection Tubes50 setsRTProduct IntroductionThis kit is suitable Product contentS665868Component50 TStorageS665868ABuffer GL25 mLRTS665868BBuffer GW1 (concentrate)13 mLRTS665868CBuffer GW2 (concentrate)15 mLRTS665868DBuffer GE15 mLRTS665868EProteinase K2×1.25 mLRTS665868FSpin Columns DM with Collection Tubes50 setsRTProduct IntroductionThis kit is suitable for the extraction of genomic DNA from fresh saliva or saliva/preservation solution mixture.The purification process of this product does not require the use of toxic solvents such as phenol or chloroform, and ethanol precipitation is not necessary. The optimized buffer system enables DNA to bind heterogeneously to the silica matrix centrifugal adsorption column, and the inhibitors of PCR and other enzymatic reactions can be effectively removed by a two-step washing step, and finally eluted with a low-salt buffer or water to obtain high-purity DNA.The purified obtained can be directly used for enzyme digestion, PCR, Real-Time PCR, library construction, Southern Blot, molecular labeling and other downstream experiments.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller fragments of extracted DNA and a decrease in the amount extracted.2. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.3. Before use, please check whether Buffer GL appears to be crystallized or precipitated.Redissolve in a 56°C water bath.4. If the downstream experiments are sensitive to RNA contamination, 4 µL DNase-Free RNase A can be added in step 3(100 mg/mL).5. For prolonged storage of salivary DNA at room temperature, our Salivary DNA Preservation Tubes are recommended.Operation steps1. Add 400 µL of saliva sample or saliva/preservation solution mixture.Note: 1) Saliva mixtures added to the preservation solution require a 50°C water bath for 1 hour or an empty 50°C temperature chamber for 2 hours prior to extraction.2) If an increase in sample volume is required, multiply the volumes of Proteinase K, Buffer GL, and anhydrous ethanol in Steps 2-4, and the liquid can be transferred in multiple times in Step 5.2. Add 40 µL of Proteinase K.3. Add 400µL Buffer GL, vortex and shake to mix thoroughly, and water bath at 56℃ for 15-30 minutes.Note: If RNA removal is required, add 4 µL of RNase A solution at a concentration of 100 mg/mL after the above steps are completed, vortex for 15 seconds, and leave at room temperature for 2 minutes.4. Centrifuge briefly to remove water droplets from the inside of the tube cap. Add 400 µL of anhydrous ethanol and mix well by vortexing and shaking. Centrifuge briefly.Note: 1) Vortex and shake to mix immediately after adding Buffer GL and anhydrous ethanol.The addition of Buffer GL and anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.2) A sol-gel product may be formed after GL and anhydrous ethanol, in which case vigorous shaking or vortexing is recommended.3) The solution obtained in the previous step is added to the adsorption column in the Collection Tube.5. (Spin Column DM) in the collection tube, and if the solution cannot be added all at once, it can be transferred in several times. centrifuge at 12,000 rpm (∼13,400 × g) for 1 min, pour off the waste solution in the collection tube, and put the adsorption column back into the collection tube.6. Add 500 µL of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.7. Add 500 µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new centrifuge tube (supplied), add 50-200 µL of Buffer GE or sterilized water to the middle of the adsorption column overhanging the column, let it stand at room temperature for 2-5 minutes, and centrifuge at 12,000 rpm for 1 minute to collect the DNA solution.-20°C to preserve DNA.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH is 7.0-8.5 (you can use NaOH to adjust the pH of the water to this range), and the elution efficiency is not high when the pH is lower than 7.0.2) Buffer GE preheated in a 65-70°C water bath and incubated at room temperature for 5 min before centrifugation can increase the yield.3) Because DNA preserved in water is subject to acidic hydrolysis, for long-term storage, elution with Buffer GE and storage at -20°C is recommended... Read More |