| Description | Inquire | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Product content: M665559Component50 TStorageM665559ABuffer GTT15 mLRTM665559BBuffer GL15 mLRTM665559CBuffer GW1(concentrate)13 mLRTM665559DBuffer GW2(concentrate)15 mLRTM665559EBuffer GE15 mLRTM665559FProteinase K1.25 mLRTM665559GSpin CoLumns DM with CoLLection Tubes50 Product content: M665559Component50 TStorageM665559ABuffer GTT15 mLRTM665559BBuffer GL15 mLRTM665559CBuffer GW1(concentrate)13 mLRTM665559DBuffer GW2(concentrate)15 mLRTM665559EBuffer GE15 mLRTM665559FProteinase K1.25 mLRTM665559GSpin CoLumns DM with CoLLection Tubes50 EART Product Introduction:This reagent kit is suitable for extracting high-purity total DNA from fresh or frozen mouse or rat tails. The method provided by this reagent kit is simple and feasible, and the purification process does not require phenol or chloroform extraction. It can obtain DNA fragments up to 50 kb, and can also effectively recover fragments of 100 bp. This reagent kit uses a unique lysis solution to effectively lyse mouse tail samples. The optimized buffer system efficiently binds the DNA generated after the lysis of mouse tail to the silica matrix adsorption column, while other pollutants can flow through the membrane; Inhibitors of PCR and other enzymatic reactions can be effectively removed through a two-step washing process, followed by washing with low salt buffer or water to obtain high-purity DNA. The purified DNA can be directly used for downstream experiments such as enzyme digestion, PCR, ReaL Time PCR, library construction, Southern BLot, and molecular labeling.Self prepared reagent: anhydrous ethanol.Preparation and important precautions before the experiment:1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.Before the first use, anhydrous ethanol should be added to BufferGW1 and BufferGW2 according to the instructions on the reagent bottle label.3. Before use, please check if there is any crystallization or precipitation in the Buffer GL. If there is any crystallization or precipitation, please dissolve the Buffer GL again in a 56 ℃ water bath.Operation steps:1. Take a tail of a rat or two mice with a length of 0.4-0.6 cm, grind it into fine powder in liquid nitrogen or cut it into pieces and place it in a centrifuge tube (provided by oneself). Join 180 µ L Buffer GTT, shake and mix well. Note: Ensure that the starting quantity of the organization does not exceed the recommended range.2. Add 20 µ L Protein K, vortex oscillation, thoroughly mix.3. Place in a 56 ℃ water bath until the tissue solution is completely clear. Generally, digestion is required for 6-8 hours. During the incubation process, vortex oscillation is required to evenly disperse the sample. Note: 1) If there is still gel like substance after incubation and vortex oscillation, digest overnight or add 20 more if necessary µ L Protein K digestion will not affect subsequent operations. 2) To remove RNA, add 4 after completing the above steps µ L 100 mg/mL RNase A solution, shake well and let stand at room temperature for 5-10 minutes.4.12000 rpm (~13400 × g) for 1 minute to remove undigested tissues similar to mouse hair. Transfer the supernatant to a new centrifuge tube (provided by oneself).5. Add 200 µ L Buffer GL, vortex oscillation, thoroughly mixed. Join 200 µ L anhydrous ethanol, vortex and shake, thoroughly mix. Short centrifugation allows the solution on the tube wall to be collected to the bottom of the tube.Attention: 1) After adding Buffer GL and anhydrous ethanol, immediately vortex and shake to mix well.2) If multiple samples are operated together, Buffer GL and anhydrous ethanol can be mixed in equal proportions and added to the samples together.3) The addition of Buffer GL and anhydrous ethanol may produce white precipitates, which will not affect subsequent experiments.6. Add all the solutions obtained in step 5 to the adsorption column (Spin CoLumins DM) that has been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.8. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Note: To further improve DNA purity, repeat step 8.9.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).10. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Note: 1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high.2) Incubating at room temperature for 5 minutes before centrifugation can increase yield.3) Use an additional 50-200 µ Re washing with L Buffer GE or sterilized water can increase yield.4) If you want to increase the final concentration of DNA, you can add the DNA eluent obtained in step 10 back onto the adsorption membrane and repeat step 10; If the elution volume is less than 200 µ L. It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ L Buffer GE or off... Read More | Products contentProducts IntroductionThis product uses the principle that the difference between the concentration of salt ions inside and outside the cell can cause the cell membrane to burst to lyses the cell and releases the genomic DNA, without the need of extracting and purifying the genomic Products contentProducts IntroductionThis product uses the principle that the difference between the concentration of salt ions inside and outside the cell can cause the cell membrane to burst to lyses the cell and releases the genomic DNA, without the need of extracting and purifying the genomic DNA.This product is suitable for a variety of sources of samples, and can be used as a template for PCR and qPCR experiments after sample processing, and can achieve the effect of the purified DNA used as a template for PCR and qPCR experiments. Usage1. Depending on the type of sample, prepare the appropriate sample size according to the table below.2. Add the sample to a 1.5-mi centrifuge tube and add the recommended volume of Solution A as shown in the table below. Vortex for 20 s and allow to stand at room temperature for 3-5 min or incubate in a metal bath at 95°C for 3-5 min as recommended in the table below.3. After the sample has been sufficiently lysed (samples incubated in a metal bath at 95°C should be brought to room temperature), add the recommended volume of Solution B as shown in the table below and vortex for 30s.4. Store processed samples at 4°C if the next test is to be performed within 2 hours, or at -20°C if the next test cannot be performed immediately.take note of1) Depending on the requirements of the experimental conditions, the amount of samples can be expanded or reduced, and the amount of Solution A and Solution B can be increased in equal proportions.2) For blood and cell samples, the temperature of room temperature lysis is required to be around 25C. If the ambient temperature does not reach 25°, the lysis time can be extended appropriately, or the vortex shaking time can be extended to ensure that the samples are fully lysed. If there is no relevant professional instrument, the centrifuge tube can be shaken vigorously to ensure adequate lysis.3) After the tissue sample is made into tissue homogenate by adding 10 times the volume of saline, it can be processed in the same way as blood samples.4) Strictly prohibit the use of expired products, please do not mix different reagents.5) laboratory supplies should be regularly cleaned and 10% of the 84 disinfectant solution or ultraviolet lamp for anti-pollution treatment, special areas dedicated to prohibit cross use, so as to avoid contamination, the end of the test, the bench should be cleaned immediately... Read More | DescriptionMaterials included in the kit are designed to be used with the Hy-Energy′s PCTPro-2000 System. They also can be used for demonstration purposes and as standards during the development of novel hydrogen storage and battery materials |