| Description | Inquire | CFDASE cell proliferation and tracking detection kit is a kit for cell proliferation and tracking detection based on CFDA se. This kit is composed of CFDASE powder, solvent and staining buffer. CFDASE is a derivative of fluorescein diacetate (FDA), which has cell membrane permeability and CFDASE cell proliferation and tracking detection kit is a kit for cell proliferation and tracking detection based on CFDA se. This kit is composed of CFDASE powder, solvent and staining buffer. CFDASE is a derivative of fluorescein diacetate (FDA), which has cell membrane permeability and does not have fluorescence luminescence. When CFDASE penetrates the cell membrane into living cells, it can be catalysed by esterases in the cytosol to produce carboxyfluorescein succinimidyl ester (CFSE), which can emit strong green fluorescence, cannot penetrate the cell membrane, and can remain intact in the cell. CFSE can also spontaneously and irreversibly covalently bind to intracellular amino groups to couple to cellular proteins. Meanwhile, the excess and uncoupled CFDASE returned to the extracellular medium by passive diffusion and was cleared by subsequent washing steps. The fluorescence of non dividing cells labeled by CFDASE is very stable, and the stable labeling time can reach several months, so it is very suitable for cell community analysis. The fluorescence of CFDASE labeled cells is very homogeneous, which is superior to other cell tracking fluorescent probes used previously, such as PKH26, and the fluorescence distribution of the divided progeny cells is also very uniform. In the process of cell division and proliferation, CFSE labeled fluorescence can be evenly distributed to the two progeny cells, and the fluorescence intensity becomes half of the parental cells. According to the fluorescence intensity, flow cytometer (FL1 channel) can detect undivided cells, cells that divide once (1 / 2 of the fluorescence intensity), twice (1 / 4 of the fluorescence intensity), three times (1 / 8 of the fluorescence intensity), and cells that divide more times. CFDASE can detect up to eight or more cleavages. CFDASE labeled cells can be used for proliferation studies in vitro and in vivo, and have the function of not staining adjacent cells. CFDASE is most commonly used to detect the proliferation of lymphocytes, and can also be used to detect the proliferation of fibroblasts, NK cells and other cells. CFDASE labeled cells showed green fluorescence. In addition to flow cytometry to detect cell proliferation, fluorescence microscopy can also be used for homogeneous staining of cell tracking observation.Components:ComponentsC598182-20TC598182-500TA. CFDA SE1 tube1 tubex5B.CFDA SE solvent20 µL500 µLC.10x CFDA SE Buffer1 mL x250 mLMatters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. CFDA and Se are easily hydrolyzed and will deteriorate quickly in aqueous solution. Please avoid contact with water during use. Contact with water during the process of labeling cells is within the permitted range. 3. CFDA se solvent will solidify at lower temperatures such as 4 º C and ice bath and stick to the bottom, wall or cover of the centrifugal tube. It can be used after incubating in a 20-25 º C water bath for a while until it is completely dissolved. 4. this kit optimizes the CFDA se staining system, but users are advised to explore the optimal working concentration and staining time according to their own cell type, culture conditions and application direction. Different cells have different lactonase activities, so the staining effect is different. 5. fluorescent dyes have quenching problems. Please avoid light during operation to slow down fluorescence quenching. 6. for your safety and health, please wear experimental clothes and disposable gloves.Usage method:1. Preparation of reagents(1) Preparation of CFDA SE storage solution: Take one tube of CFDA SE provided in the reagent kit and restore it to room temperature. Instantly centrifuge to allow the powder to fully settle to the bottom of the tube. Add 100 µ L CFDA SE solvent (add 20 µ L CFDA SE solvent) to it and dissolve it thoroughly to prepare CFDA SE storage solution (1000 ×). Prepared CFDA SE storage solution, stored at -20 ℃ in the dark, with a shelf life of two months- Storing at 70 ℃ in the dark can extend the usage time appropriately.(2) Preparation of CFDA SE Buffer: Dilute 10 x CFDA SE Buffer to 1 x with sterile cell culture grade water as needed. The prepared 1 × CFDA SE Buffer can be stored at 4 ℃ and can be stored at -20 ℃ if not in use for a long time.2. Marking and detection(1) Centrifuge the collected cells, use 1 mL 1 × CFDA SE Buffer to re suspend the cells in a 15 mL centrifuge tube, and adjust the cell concentration to 1-5 × 106 cells/mL.(2) Preparation of CFDA SE working solution: Dilute the CFDA SE storage solution (1000 ×) with 1 × CFDA SE Buffer to 2 ×.(3) Staining: Add 1 mL of CFDA SE working solution (2 x) to 1 mL of cell suspension to be labeled, invert and mix well, and incubate at 37 ℃ for 10 minutes.(4) Immediately add 5 times the volume of preheated complete culture medium (including serum) to the centrifuge tube, invert and mix well to terminate the labeling reaction.(5) Centrifuge at 1000 rpm for 5 minutes at room temperature to remove the supernatant, then wash once with 5-10 mL of complete culture medium.(6) Add 5-10 mL of complete culture medium and incubate at 37 ℃ for 5 minutes to promote the residence of CFDA SE in the cells and the entry of unreacted CFDA SE into the complete cell culture medium. Centrifuge at 1000 rpm for 5 minutes at room temperature to remove the supernatant and complete the final wash.(7) Subsequently, the cells can be cultured using the normal cultivation method. The labeling effect can be directly observed under a fluorescence microscope, or cell proliferation can be detected by flow cytometry after appropriate cultivation time, showing green fluorescence. The labeled cells can also be used for transplantation in live animals and for fluorescence tracing.Note: a If cell fixation is required, use aldehyde fixatives such as 4% paraformaldehyde to fix at room temperature for 15 minutes; If additional labeling such as antibody labeling is required afterwards, please permeabilize the cells with ice acetone for 10 minutes. b. The optimal labeling concentration and incubation time for CFDA SE vary for different cells. The initial experiment can be conducted according to the experimental steps. If the effect is not satisfactory, it is recommended to adjust the staining concentration and incubation time to achieve the best labeling effect.Scope of application:Cell proliferation assay... Read More | G665573 Component 10 T Storage G665573A Buffer P1 30 mL RT G665573B Buffer P2 30 mL RT G665573C Buffer E3 30 mL RT G665573D Buffer PS 15 mL RT G665573E Buffer PW (concentrate) 10 mL RT G665573F Endo-Free Buffer EB 30 mL RT G665573G RNase A (10 mg/mL) 600 碌L RT G665573H Endo-Remover FX 10 EA G665573 Component 10 T Storage G665573A Buffer P1 30 mL RT G665573B Buffer P2 30 mL RT G665573C Buffer E3 30 mL RT G665573D Buffer PS 15 mL RT G665573E Buffer PW (concentrate) 10 mL RT G665573F Endo-Free Buffer EB 30 mL RT G665573G RNase A (10 mg/mL) 600 碌L RT G665573H Endo-Remover FX 10 EA RT G665573I Plungers 10 EA RT G665573J Spin Columns DX with Collection Tubes 10 EA RT G665573K Centrifuge Tubes (15 mL) 10 EA RTProduct IntroductionThis kit is specially designed for the efficient and rapid extraction of plasmids from 15-50 ml of bacterial fluids. On the basis of cell lysis by alkaline lysis method, it adopts unique silicon matrix membrane adsorption technology to bind plasmid DNA efficiently and exclusively, and each adsorption column can adsorb up to 250 µg of plasmid DNA; at the same time, it adopts a special buffer system and endotoxin removal filter to effectively remove endotoxin, genomic DNA, RNA, protein and other impurities. The plasmids obtained from this kit are of high purity and stable quality, and can be used for cell transfection, as well as DNA sequencing, PCR, in vitro transcription, endonuclease digestion and other experiments.Self-contained reagents: anhydrous ethanol, isopropanol.Pre-experiment Preparation and Important Notes1. All components are stable for 1 year in a dry, room temperature (15-30°C) environment, and longer by placing the adsorption columns at 2-8°C. Buffer P1 with RNase A is stable for 6 months at 2-8°C.2. Before the first use, add all of the RNase A solution to Buffer P1, mix well, and store at 2-8°C. Before use, it needs to be left at room temperature for a period of time, return to room temperature and then use.3. Anhydrous ethanol should be added to Buffer PW before the first use according to the instructions on the reagent bottle label.4. Please check Buffer P2 and Buffer E3 for crystallization or precipitation before use. If there is any crystallization or precipitation, the clarification can be restored by taking a water bath at 37℃ for a few minutes.5. Be careful not to touch Buffer P2 and Buffer E3 directly, and tighten the lid immediately after use.6. The amount and purity of extracted plasmid is related to the concentration of bacterial culture, strain type, plasmid size, plasmid copy number and other factors.7. The adsorption columns treated with Buffer PS should be used immediately to avoid leaving them for too long.Operation steps1.Take 15-50 ml of fresh bacterial solution from the overnight culture, add it to a centrifuge tube (self-prepared) and centrifuge at 5000 × g for 10 minutes to collect the bacteria, and aspirate all the supernatant as much as possible.2.Add 2.5 ml of Buffer P1 to the centrifuge tube in which the bacterial precipitate has been left (please check that RNase A has been added first) and suspend the bacterial precipitate by mixing thoroughly using a pipette or vortex shaker. Note: If the bacterial mass is not thoroughly mixed, it will affect the lysis effect and make the extraction amount and purity low.3.Add 2.5 ml of Buffer P2 to the centrifuge tube, mix gently up and down 8-10 times to fully lyse the organisms, and leave at room temperature for 3-5 minutes. At this point the solution should become clear and viscous. Note: Mix gently, do not shake vigorously, so as not to interrupt the genomic DNA and cause genomic DNA fragments to be mixed in the extracted plasmid. If the solution does not become clear, it suggests that the amount of bacteria may be too large and the lysis is not complete, and the amount of bacteria should be reduced.4.Add 2.5 ml of Buffer E3 to the centrifuge tube and mix immediately by turning up and down 8-10 times, at which time a white flocculent precipitate appears. Note: Buffer E3 should be mixed immediately after addition to avoid localized precipitation.5.Install the cap of the filter (Endo-Remover FX), transfer the solution obtained in step 4 to the filter, wait until the white flocculent precipitate floats on the upper layer of the solution, remove the cap of the filter, align the filter with a clean 15 ml centrifuge tube (supplied), and slowly push the handle (Plungers) to filter, so that as much as possible of the solution passes through, and the filtrate is collected in the centrifuge tube.6.Add 1/3 solution volume of isopropanol to the filtrate and mix upside down.7.Column Equilibrium: Add 1ml Buffer PS to the adsorption column (Spin Columns DX) that has been loaded into a 15ml centrifuge tube, centrifuge for 2 minutes at 2500 x g. Pour off the waste liquid from the centrifuge tube and put the adsorption column back into the centrifuge tube.8.The mixture of filtrate and isopropanol from step 6 was transferred to the equilibrated adsorption column (which had been loaded into a collection tube).9.Centrifuge at 2500 x g for 1 minute, pour off the waste solution in the collection tube and put the adsorption column back into the collection tube. Note: The maximum volume of the adsorption column is 4 ml, so the solution obtained in step 8 is passed through the column in 2 times.10.Add 2 ml of Buffer PW to the adsorption column (please check that anhydrous ethanol has been added first), centrifuge at 2500 × g for 1 min, and pour off the waste liquid in the collection tube.11.Repeat step 10.12.The adsorbent column was put back into the collection tube and centrifuged at 2500 × g for 2 min, the waste liquid was poured off, and the column was left to dry at room temperature for 5 min.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.)13. Place the adsorption column in a new 15 ml centrifuge tube, add 0.5-1 ml Endo-Free Buffer EB to the middle of the adsorbent membrane, leave it at room temperature for 2-5 minutes, centrifuge it at 2500 × g for 2 minutes, and collect the plasmid solution into the centrifuge tube. -20°C to store the plasmid.Note: 1) In order to increase the recovery efficiency of the plasmid, the obtained solution can be reintroduced into the adsorption column, left at room temperature for 2-5 minutes, centrifuged at 2500 x g for 2 minutes, and the plasmid solution can be collected into a centrifuge tube.2) When the plasmid copy number is low or >10kb, Endo-Free Buffer EB can increase the extraction efficiency by preheating at 65-70°C in a water bath... Read More | Inquire | Product contentcomponent50T200TBuffer LP125mL100mLBuffer LP210mL40mLBuffer LP3 (concentrate)21ml84mlBuffer GW2 (concentrate)15mL75mlBuffer GE15mL60mLRNase A(10 mg/ml)300µl1.25mLSpin Columns DM with Collection Tubes50200ProductsThis kit uses centrifugal adsorption columns with highProduct contentcomponent50T200TBuffer LP125mL100mLBuffer LP210mL40mLBuffer LP3 (concentrate)21ml84mlBuffer GW2 (concentrate)15mL75mlBuffer GE15mL60mLRNase A(10 mg/ml)300µl1.25mLSpin Columns DM with Collection Tubes50200ProductsThis kit uses centrifugal adsorption columns with high efficiency and specific binding of nucleic acids and a unique buffer system, which is suitable for extracting genomic DNA from a wide variety of different fresh or frozen plant tissues with maximum removal of impurities from the plant tissues. The kit eliminates the need for phenol/chloroform extraction and is safe to handle. The extracted genomic DNA fragments are large, high purity, stable and reliable quality, suitable for PCR, fluorescence quantitative PCR, molecular labeling, library construction and other experiments.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller fragments of extracted DNA and a decrease in the amount extracted.2. Anhydrous ethanol should be added to Buffer LP3 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use. Check Buffer LP1 and Buffer LP2 for crystallization or precipitation before use. If crystallization or precipitation occurs, re-dissolve Buffer LP1 and Buffer LP2 in a 56°C water bath. Procedure1. Take about 100mg of fresh plant tissue or about 20mg of dry weight tissue and add liquid nitrogen to grind it fully.2. Collect the ground powder into a centrifuge tube (self-provided), add 400 µl Buffer LP1 and 6 µl RNase A (10 mg/ml), vortex and oscillate for 1 minute, and leave it at room temperature for 10 minutes to allow for full cleavage.Note: 1) Use vortex shaking or pipette blowing to fully lyses the tissue, incomplete tissue lysis will affect the final DNA yield. 2) Do not mix Buffer LP1 with RNase A prior to use.3. Add 130 µl Buffer LP2, mix well and vortex for 1 minute.4. Centrifuge at 12,000 rpm (~13,400 x g) for 5 minutes and transfer the supernatant to a new centrifuge tube (supplied).5. Add 1.5 times the volume of Buffer LP3 (check that anhydrous ethanol has been added before use) and mix thoroughly (e.g., 500 µl filtrate to 750 µl Buffer LP3).Note: Buffer LP3 should be mixed immediately after addition; precipitation may occur but will not affect subsequent experiments.6. Add all of the solution and precipitate obtained in the previous step to the adsorption columns (Spin Columns DM) that have been loaded into the collection tubes, if the solution cannot be added all at once, it can be transferred in several times. centrifuge the columns at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tubes, and put the columns back into the collection tubes.7. Add 500 µl of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: If the adsorbent membrane appears green, add 500 µl of anhydrous ethanol to the adsorbent column, centrifuge the column at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.8. Repeat step 7.9. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).10. Place the adsorption column in a new centrifuge tube (supplied), add 50-100 µl of Buffer GE or sterilized water dropwise to the middle of the adsorbent membrane, leave it at room temperature for 2-5 minutes, and centrifuge it at 12,000 rpm for 1 minute to collect the DNA solution. -The DNA solution was collected by centrifugation at 12,000 rpm for 1 min.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH value of the eluent has a great influence on the elution efficiency, if you use water as the eluent, you should ensure that the pH value is 7.0-8.5 (you can use NaOH to adjust the pH value of the water to this range), and when the pH value is lower than 7.0, the elution efficiency is not high.2) Incubation at room temperature for 5 minutes prior to centrifugation increases yield.(3) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 10 can be re-added to the adsorbent membrane and repeat step 10; if the elution volume is less than 100µl, the final concentration of DNA can be increased, but it may reduce the total DNA yield. If the amount of DNA obtained is less than 1µg, 50µl Buffer GE is recommended for elution.4) Because DNA stored in water is subject to acidic hydrolysis, for long-term storage, elution with Buffer GE and storage at -20°C are recommended... Read More |