| Description | Inquire | Inquire | Product content: M665794Component125 TStorageM665794A2×miRNA qPCR Mixture (ROX)2×750 µL-20℃. Avoid freeze/thaw cycleM665794BReverse Primer, 10 µM60 µL-20℃. Avoid freeze/thaw cycleM665794CddH2O1.5 mL-20℃. Avoid freeze/thaw cycle Product Introduction:This kitProduct content: M665794Component125 TStorageM665794A2×miRNA qPCR Mixture (ROX)2×750 µL-20℃. Avoid freeze/thaw cycleM665794BReverse Primer, 10 µM60 µL-20℃. Avoid freeze/thaw cycleM665794CddH2O1.5 mL-20℃. Avoid freeze/thaw cycle Product Introduction:This kit uses the principle of SYBR Green I chimeric fluorescent dye method for miRNA fluorescence quantitative PCR detection. The kit includes 2 x miRNA qPCR Mixture and Reverse Primer required for detection. 2 x miRNA qPCR Mixture is a new generation pre mixed form of fluorescence quantitative PCR detection reagent specially developed for miRNA quantitative detection. The fluorescent dye SYBR Green I contained in it can bind to all double stranded DNA, making the product suitable for detecting different target sequences without the need to synthesize specific labeled probes. The GoldStar Taq DNA polymerase is a chemically modified and highly efficient thermal starter enzyme, coupled with a unique buffer system, which enhances reaction specificity, sensitivity, and enables accurate quantification of miRNA over a wider range. The 2x miRNA qPCR Mixture contains ROX dye and is suitable for fluorescence quantitative PCR instruments that require ROX as a calibration dye.Note: This kit must be used in conjunction with the miRNA cDNA first strand synthesis kit.Self prepared experimental materials: qPCR upstream primer.Forward Primer design principles:1. Follow the most common principles of primer design.2.Based on mature miRNA sequences, replacing U with T is the most basic and simplest design method.3.The Tm value of the downstream primer provided in the reagent kit is 63.6 ℃, and the Tm value of the upstream primer should be designed to be around 63.6 ℃ as much as possible.4. If the Tm value of the primer directly designed according to principle "2" is too low, several bases (preferably G or C bases) can be added to the 5 'end of the primer; One or several A bases can also be added at the 3 'end; Alternatively, both the 5 'and 3' ends can be modified simultaneously.5.If the Tm value of a primer designed directly according to principle "2" is too high, several bases can be removed from the 5 'or 3' end of the primer.Notes:1. Before using the reagent, please gently mix it upside down to avoid foaming, and use it after a brief centrifugation.2. The amount of miRNA first strand cDNA added should not exceed 10% of the volume of Real time PCR.3. For special detection systems, high content of cDNA templates can easily lead to non-specific amplification. Dilute cDNA appropriately (10 or 100 times dilution) based on the abundance of detected miRNAs.4. The 2x miRNA qPCR Mixture in this product contains SYBR Green I and ROX dyes. When storing this product or preparing PCR reaction solution, strong light exposure should be avoided.5. Avoid repeated freezing and thawing of this product. Repeated freezing and thawing may cause a decrease in product performance. This product can be stored at -20 ℃ for long-term storage. If frequent use is required in the short term, the 2xmiRNA qPCR Mixture can be stored at 2-8 ℃. However, the Reverse primer still needs to be stored at -20 ℃.Operation steps:1. Melt 2 x miRNA qPCR Mixture and Reverse Primer at room temperature (10 µ M). 2. When using, please gently mix the 2x miRNA qPCR Mixture upside down to avoid foaming, and use after brief centrifugation. If the reagent is not well mixed, its reaction performance will decrease.3. Place the reagent on ice and prepare the reaction system according to the following table: reagent volume final concentration 2×miRNA qPCR Mixture(ROX) 10 µl 1× Forward primer(10 µM) 0.4µl 0.2 µM Reverse primer(10 µM) 0.4µl 0.2 µM MiRNA first strand cDNA X µl — ddH2O up to 20 µl —4. The reaction program is set as follows:Attention!The pre denaturation reaction of this product must be completed at 95 ℃ for 10 minutes! Note: 1) The hot start enzyme used in this product must be activated under pre denaturation conditions of 95 ℃ and 10 minutes.2) The annealing temperature should be set at 60-64 ℃ as a reference range. When non-specific reactions occur, the annealing temperature can be increased... Read More | S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948D DNA Standard 2 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948E DNA Standard 3 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948F DNA Standard 4 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948G DNA Standard 5 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis product is used for real-time fluorescence quantitative PCR (qPCR) using the product after NGS library construction by dye method (SYBR Green I). The kit provides the reaction mixture, DNA primer mixture, and standards required for the qPCR process, and the reagent system is complete, easy and convenient to operate. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, and able to quickly and accurately quantify the concentration of the constructed library. It is suitable for fluorescent quantitative PCR instruments that do not require ROX as a calibration dye, such as Roche LightCycler 480, Roche LightCyler 96, Bio-radiCyleriQ, iQ5, CFX96.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.Note: High Rox and Low Rox are formulated as described in Use 2.Scope of applicationThis product is designed for absolute quantification of the concentration of Illumina platform second-generation sequencing libraries. The end of the library contains Illumin P5 and P7 chip binding sequences, the length of which does not exceed 1kb, and the concentration of which is not less than 0.002pM can be used to perform quantitative experiments with this product. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-20 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR Master Mix10 µlqPCR Primer Mix 10.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: add 1 µl High Rox per 50 µl of reaction system;Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.qPCR reaction programThe annealing temperature should be 60-64°C as a reference for the setting range, and the annealing temperature can be increased when a non-specific reaction occurs.If the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.data analysisStandard curve productionThe standard curve was plotted using Ct values in the valid range. The standard curve correlation coefficient R2 should not be less than 0.99 and the slope should lie between -3.1 and -3.6. If the standard curve parameters are not reasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard 120 pMDNA Standard 22 pMDNA Standard 30.2 pMDNA Standard 40.02 pMDNA Standard 50.002 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More | Vitamins Kit is a multivitamin mix comprising biotin, folic acid, vitamin B6, riboflavin, thiamine, D-pantothenic acid and niacinamide.Vitamins Kit has been used as a vitamin supplement in the minimal medium for conidia spores and vegetative cultures |