| Description | Inquire | Description:Acetylcholinesterases (AChEs) are enzymes that hydrolyze the neurotransmitter acetylcholine (ACh) to acetate and choline. AChE is located at the synaptic cleft and functions to terminate synaptic transmission by catalyzing the breakdown of ACh allowing cholinergic neurons to Description:Acetylcholinesterases (AChEs) are enzymes that hydrolyze the neurotransmitter acetylcholine (ACh) to acetate and choline. AChE is located at the synaptic cleft and functions to terminate synaptic transmission by catalyzing the breakdown of ACh allowing cholinergic neurons to return to a resting state after activation. It is also found in membranes of red blood cells, motor and sensory fibers, muscles, nerves and central and peripheral tissues. Changes in AChE activity may result from exposure to certain insecticides, which act as cholinesterase inhibitors. Inhibitors of AChE are also used to treat certain conditions such as dementia.Acetylcholinesterase activity assay kit has been used to determine the activity of acetylcholinesterase in a rat organophosphate model and in brain tissue homogenates.Principle:Acetylcholinesterase can catalyze the hydrolysis of acetylcholine to choline, and the reaction of choline with disulfide p-nitrobenzoic acid to produce 5-merhydryl-nitrobenzoic acid (TNB). The product has a characteristic absorption peak at 412 nm, and the activity of acetylcholinesterase can be characterized by the change of light absorption valueThe Dilution Calculator EquationConcentration (start)xVolume (start)= Concentration (final)× Volume (final)This equation is commonly abbreviated as: C1V1 = C2V2... Read More | The Endo F Multi-Kit will deglycosylate N-linked glycans in both native and denatured conditions. Each enzyme has a distinct specificity for N-linked glycan release. One can choose to use the three enzymes in combination to completely remove all N-linked glycans present on a glycoprotein or peptide,The Endo F Multi-Kit will deglycosylate N-linked glycans in both native and denatured conditions. Each enzyme has a distinct specificity for N-linked glycan release. One can choose to use the three enzymes in combination to completely remove all N-linked glycans present on a glycoprotein or peptide, or to use each enzyme independently and thereby determine the type of N-glycans present.Product DescriptionThe Endo F Multi-kit is recommended to deglycosylate native proteins that are resistant to PNGase F cleavage under non-denatured conditions due to the glycan location within the protein’s three-dimensional structure, as these enzymes are known to be less sensitive to protein conformation.Each of the enzymes has a different N-linked glycan specificity:Endoglycosidase F1 cleaves high mannose and some hybrid type N-glycansEndoglycosidase F2 releases biantennary and high mannose glycans (at a 40X reduced rate)Endoglycosidase F3 will release triantennarry and fucosylated biantennary N-glycansContents1 vial: Endo F1- 20 µl (0.3 U)20 mM Tris-HCl pH 7.51 vial: Endo F2- 20 µl (0.1 U)10 mM sodium acetate, 25 mM NaCl, pH 4.51 vial: Endo F3- 20 µl (0.1 U)20 mM Tris-HCl pH 7.51 vial: 5x Reaction Buffer - 400 µl250 mM sodium acetate, pH4.51 vial: 5x Reaction Buffer - 400 µl250 mM sodium phosphate, pH5.5Specific ActivityDefined as the amount of enzyme required to catalyze the release of N-linked oligosaccharides from 1 micro-mole of denatured Ribonuclease B (Endo F1) or porcine fibrinogen peptides (Endo F2/F3) in 1 minute at 37°C, pH 5.5 (PH 4.5 for Endo F3). Cleavage is monitored by SDS-PAGE.FormulationThe enzymes are provided as a sterile-filtered solution.StabilitySeveral days exposure to ambient temperatures will not reduce activity. Stable at least 12 months when stored properly.SpecificityEndo F1 cleaves Asparagine-linked (N-linked) high mannose or hybrid oligosaccharides. Endo F2 cleaves N-linked biantennary oligosaccharides and high mannose (at a 40X reduced rate). Endo F3 cleaves free or N-linked fucosylated biantennary or triantennary oligosaccharides,as well as triamannosylchitobiose core structures. These enzymes cleave between the two N-acetylglucosamine residues in the diacetylchitobiose core of the oligosaccharide, generating a truncated sugar molecule with one N-acetylglucosamine residue remaining on the asparagine. The recombinant version is not glycosylated, which may result in properties differing from the native protein.Quality & PurityEndo F1, Endo F2, and Endo F3 are tested for contaminating protease as follows: 10 µg of denatured BSA is incubated at 37°C for 24 hours with 2 µl of enzyme. SDS-PAGE analysis of the treated BSA shows no evidence of degradation. The absence of exoglycosidase contaminants is confirmed by extended incubations with the corresponding pNP-glycosides. Directions for use 1. Add up to 200 µg of glycoprotein to an Eppendorf tube. Adjust to 34 µl final volume with de-ionized water. 2. Add 10 µl Endo F2 &F3 5x Reaction Buffer, 250 mM sodium acetate pH 4.5. Use Endo F1 buffer, 250 mM sodium phosphate pH 5.5 if you are using the Endo F1 enzyme alone. 4. Add 2.0 µl of each enzyme to the reaction. Incubate 3 hours at 37°C. Monitor cleavage by SDS-PAGE. Applications– Deglycosylation of native proteins resistant to PNGase F cleavage– Determination of glycan type (high mannose, biantennary, tri/tetrantennary)– Deglycosylating proteins which normally precipitate when deglycosylating– X-Ray CrystallographyThese three enzymes cleave asparagine-linked (N-linked) oligosaccharides between the two GlcNAc residues in the core of the oligosaccharide, generating a truncated sugar molecule with one N-acetylglucosamine residue remaining on the asparagine, enhancing the solubility of the protein. In contrast, PNGase F removes the oligosaccharide intact... Read More | Apoptosis refers to the cell autonomous and orderly death controlled by genes to maintain the stability of the internal environment. Apoptosis is different from cell necrosis. Apoptosis generally refers to a programmed cell death process that occurs during the development of body cells or under the Apoptosis refers to the cell autonomous and orderly death controlled by genes to maintain the stability of the internal environment. Apoptosis is different from cell necrosis. Apoptosis generally refers to a programmed cell death process that occurs during the development of body cells or under the action of some factors through the regulation of intracellular genes and their products. Cell necrosis is a cell death process that is caused by strong physical and chemical or biological factors to cause disordered changes in cells. The difference between apoptosis and necrosis lies in the characteristic morphological and biochemical changes, including the changes of cell membrane permeability and nuclear chromatin, the contraction of cytoplasm and the loss of membrane asymmetry. The oxazole yellow/pi membrane permeability apoptosis detection kit produced by our company is a dual fluorescence detection kit based on oxazole yellow and PI dyes. This kit is suitable for fluorescence microscopy, flow cytometry, fluorescence microplate reader and other fluorescence detection systems. Oxazole yellow is a non cell membrane penetrating cyanine monomer green fluorescent dye with high affinity for DNA. It basically has no fluorescence when it is not bound to DNA, but can emit bright green fluorescence after binding to DNA. When apoptosis occurs, the permeability of cell membrane changes. At this time, oxazole yellow can enter the cell and bind to DNA, emitting bright green fluorescence. Therefore, it is often used for the detection of apoptosis. It should be noted that oxazole yellow can also stain dead cells, so it needs to be double stained with PI that specifically fluorescently stains dead cells to effectively determine apoptosis. PI (propidium iodide) is a red fluorescent dye that can stain DNA. It is an analog of pyridine bromide that releases red fluorescence after embedding double stranded DNA. Although PI cannot pass through the membrane of living cells, it can cross the damaged cell membrane of dead cells to stain nuclei. Therefore, oxazole yellow combined with PI can be directly used for the detection of apoptosis. Apoptotic cells show green fluorescence, dead cells show both red and green fluorescence positive, and living cells have little or no fluorescence.Components: Components O598364-50T A. Oxazole yellow dye 50 µL B. Propidium Iodide (PI) 50 µLUsage (using flow cytometry as an example):1. Cell preparation(1) For adherent cells, after trypsin digestion, resuspend in culture medium and wash once with pre cooled PBS; The digestion time of trypsin should not be too long to prevent false positives. Note: Digest with trypsin and allow the cells to recover in the optimal cell culture conditions and medium for about 30 minutes, then stain.(2) For suspended cells, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, and wash once with pre cooled PBS.2. Cell stainingSuspend cells in pre cooled PBS, with a recommended cell count of 106 cells/mL per sample. Add 1 µ L Oxazole Yellow and 1 µ L to 1 mL of the samplePI, Gently blow and mix well. Incubate on ice in the dark for 30 minutes. Note: We suggest adding the following two experimental controls:Blank tube: negative control group cells, without dye, used to regulate voltage.Single staining tube: Positive control group cells were treated with only two tubes, Oxazole yellow and PI, for regulating compensation.3. Flow detectionAfter incubation, the sample can be directly detected by flow cytometry, or centrifuged at 1000 rpm for 5 minutes, the supernatant can be aspirated, and the sample can be resuspended in 1 mL of pre cooled PBS for flow cytometry detection. Oxazole yellow can be excited by a 488 nm laser, and the detected fluorescence emission spectrum is around 530 ± 30 nm (FITC channel), while the PI channel emission spectrum is around 617 nm (PI or PE channel).Product parameters:Oxazole yellow dye:ex/em = 491 / 509 nm (bound DNA); Propidium iodine:ex/em = 535 / 617 nm (combined with DMatters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. fluorescent dyes have quenching problems. Please try to avoid light to slow down fluorescence quenching. 3. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Membrane permeability apoptosis assay... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export |