| Description | Inquire | Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly luciferase is widely used in gene regulation and drug screening. Firefly luciferase is a protein with a molecular weight of about 61 KD. In the presence of ATP, magnesium ions and oxygen, it can catalyze the production of oxyluciferin from luciferin. In the process of luciferin oxidation, it will produce a light signal. The optical signal of this kit is a kind of instantaneous light, which needs to be detected immediately after adding the working solution. The half-life of optical signal is about 5 min.Instruction:1.Working fluid configuration ( 1 ) Restore all components to room temperature. ( 2 ) The component B ( stock solution ) was fully diluted with component A to prepare a 0.2 mg / mL firefly luciferase working solution, which was vortexed and shaken to ensure full mixing. Note : The firefly luciferase working solution cannot be repeatedly frozen and thawed. If the dosage of a single experiment is small, it is recommended to subpackage according to a single dosage. At room temperature, the activity decreased by about 10 % after the working solution was configured for 3 h, and the activity decreased by about 25 % after 5 h. 2.chemiluminescence value detection ( 1 ) The cell culture plate was taken out from the incubator and incubated at room temperature for 20 min to restore it to room temperature ( 22-25 ° C ). ( 2 ) Add the same volume of firefly luciferase working solution with the medium to the culture plate and mix well. ( 3 ) Incubation at room temperature for 5 min. Note : The incubation time can be adjusted according to cell type and cell number. ( 4 ) The values were read by multifunctional microplate reader or chemiluminescence instrument ( instrument parameters : the determination time was 10 s, the determination interval was 2 s ).Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. the strongest wavelength of bioluminescence catalyzed by firefly luciferase is 560 nm. 3. to prevent interference between holes, it is recommended to use white opaque orifice plate.Recommendation:Component B is recommended to use sterile water in advance to configure 2 mg / mL storage solution, A component and B component configured as storage solution, and small batch packaging according to the experimental requirements. The detection working fluid is recommended to be used now to avoid repeated freezing and thawing. Component:One-Step Firefly Luciferase Assay Buffer;D-Luciferin Scope of application:Mainly used for ADCC detection... Read More | Apoptosis refers to the cell autonomous and orderly death controlled by genes to maintain the stability of the internal environment. Apoptosis is different from cell necrosis. Apoptosis generally refers to a programmed cell death process that occurs during the development of body cells or under the Apoptosis refers to the cell autonomous and orderly death controlled by genes to maintain the stability of the internal environment. Apoptosis is different from cell necrosis. Apoptosis generally refers to a programmed cell death process that occurs during the development of body cells or under the action of some factors through the regulation of intracellular genes and their products. Cell necrosis is a cell death process that is caused by strong physical and chemical or biological factors to cause disordered changes in cells. The difference between apoptosis and necrosis lies in the characteristic morphological and biochemical changes, including the changes of cell membrane permeability and nuclear chromatin, the contraction of cytoplasm and the loss of membrane asymmetry. The oxazole yellow/pi membrane permeability apoptosis detection kit produced by our company is a dual fluorescence detection kit based on oxazole yellow and PI dyes. This kit is suitable for fluorescence microscopy, flow cytometry, fluorescence microplate reader and other fluorescence detection systems. Oxazole yellow is a non cell membrane penetrating cyanine monomer green fluorescent dye with high affinity for DNA. It basically has no fluorescence when it is not bound to DNA, but can emit bright green fluorescence after binding to DNA. When apoptosis occurs, the permeability of cell membrane changes. At this time, oxazole yellow can enter the cell and bind to DNA, emitting bright green fluorescence. Therefore, it is often used for the detection of apoptosis. It should be noted that oxazole yellow can also stain dead cells, so it needs to be double stained with PI that specifically fluorescently stains dead cells to effectively determine apoptosis. PI (propidium iodide) is a red fluorescent dye that can stain DNA. It is an analog of pyridine bromide that releases red fluorescence after embedding double stranded DNA. Although PI cannot pass through the membrane of living cells, it can cross the damaged cell membrane of dead cells to stain nuclei. Therefore, oxazole yellow combined with PI can be directly used for the detection of apoptosis. Apoptotic cells show green fluorescence, dead cells show both red and green fluorescence positive, and living cells have little or no fluorescence.Components: Components O598364-50T A. Oxazole yellow dye 50 µL B. Propidium Iodide (PI) 50 µLUsage (using flow cytometry as an example):1. Cell preparation(1) For adherent cells, after trypsin digestion, resuspend in culture medium and wash once with pre cooled PBS; The digestion time of trypsin should not be too long to prevent false positives. Note: Digest with trypsin and allow the cells to recover in the optimal cell culture conditions and medium for about 30 minutes, then stain.(2) For suspended cells, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, and wash once with pre cooled PBS.2. Cell stainingSuspend cells in pre cooled PBS, with a recommended cell count of 106 cells/mL per sample. Add 1 µ L Oxazole Yellow and 1 µ L to 1 mL of the samplePI, Gently blow and mix well. Incubate on ice in the dark for 30 minutes. Note: We suggest adding the following two experimental controls:Blank tube: negative control group cells, without dye, used to regulate voltage.Single staining tube: Positive control group cells were treated with only two tubes, Oxazole yellow and PI, for regulating compensation.3. Flow detectionAfter incubation, the sample can be directly detected by flow cytometry, or centrifuged at 1000 rpm for 5 minutes, the supernatant can be aspirated, and the sample can be resuspended in 1 mL of pre cooled PBS for flow cytometry detection. Oxazole yellow can be excited by a 488 nm laser, and the detected fluorescence emission spectrum is around 530 ± 30 nm (FITC channel), while the PI channel emission spectrum is around 617 nm (PI or PE channel).Product parameters:Oxazole yellow dye:ex/em = 491 / 509 nm (bound DNA); Propidium iodine:ex/em = 535 / 617 nm (combined with DMatters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. fluorescent dyes have quenching problems. Please try to avoid light to slow down fluorescence quenching. 3. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Membrane permeability apoptosis assay... Read More | The fluorescent dye PKH67 is suitable for conventional cell membrane labeling. It is a green fluorescent dye that can track cells in vitro and in vivo. It labels cells by binding to the lipid components of the membrane structure. PKH67 has low cytotoxicity, low fluorescence background, high fat The fluorescent dye PKH67 is suitable for conventional cell membrane labeling. It is a green fluorescent dye that can track cells in vitro and in vivo. It labels cells by binding to the lipid components of the membrane structure. PKH67 has low cytotoxicity, low fluorescence background, high fat solubility, can easily penetrate cell membranes, and has strong and stable green fluorescence. PKH67-labeled cells can be used for in vitro and in vivo proliferation studies, and have the function of not staining neighboring cells. In the process of cell division and proliferation, the fluorescence intensity of PKH67 will gradually decrease as the cells divide. The labeled fluorescence can be evenly distributed to the two sub-generation cells, so its fluorescence intensity is half that of the parent cell. According to this feature, It can be used to detect cell proliferation, cell cycle estimation and cell division, etc. The fluorescence of PKH67-labeled cells is very uniform, and the fluorescence distribution of sub-generation cells after division is also more uniform. In the process of cell division and proliferation, PKH67-labeled fluorescence can be evenly distributed between the two sub-generation cells, and the fluorescence intensity becomes half of that of the parent cell. According to the difference in fluorescence intensity, the undivided cells can be detected by flow cytometry. One time (1/2 the fluorescence intensity), the second time (1/4 the fluorescence intensity), three times (1/8 the fluorescence intensity), and more divisions of cells. PKH67 can detect splits up to six times or even more. In addition to the detection of cell proliferation, PKH67 can also be used for in vitro tracking of cells. After labeling, the fluorescence expression is stable in the cell, and the positive labeling rate is over 98%. The labeled cells have good morphology, which can effectively observe the cells in vitro. Induce differentiation; or inject labeled cells into the body, it can effectively show the migration and differentiation of transplanted cells in living tissues. PKH67-labeled cells can be used for in vivo observation for as long as several weeks. It is often used for in vivo cell detection experiments and experiments to observe long-term cell activity using fluorescence electron microscope. PKH67 is less toxic and does not affect cell proliferation. This method is simple to operate, does not use radioactive isotopes, and poses no safety hazards. You can get the desired experimental data faster, more accurately and more safely.Due to the longer length of the charcoal tail, internal studies have shown that PKH67 is less transferred between cells than PKH2. In in vivo studies using PKH1 and PKH2, the fluorescence intensity will slowly lose. Since this is a behavioral characteristic of green cell linker dye rather than red cell linker dye, PKH67 will have similar properties. The correlation between the in vitro cell membrane retention of non-dividing cells and the in vivo fluorescence half-life reveals that the in vivo fluorescence half-life of PKH67 is 10-12 days. Other green cell linker dyes with similar half-lives have been used to monitor the transport of lymphocytes and macrophages in the body within one to two months. The results indicate that PKH67 can also be used for medium-term in vivo tracking studies.The dye can stably bind to the lipid region of the cell membrane and emit fluorescence, and is mainly used for cell labeling in vitro, cell proliferation research in vitro, and cell tracing research in vivo and in vitro. The fluorescence half-life of PKH67 in vivo is 10-12 days. Compared with PKH-67, PKH-26 has a longer half-life, and the half-life of PKH26 labeled on rabbit red blood cells is more than 100 days. Especially suitable for in vitro proliferation research and long-term in vivo cell tracking research. After PKH67 labels the cells, flow cytometry is usually used for cell proliferation detection.Kit components0.1ml kits: P266290A-0.1ml P266290B-10ml1ml kits: P266290A-1ml P266290B-60mlDyes with A suffix and diluents with B suffix are used togetherPKH67 labeled cells show green fluorescence, the fluorescence wavelength: λex=490 nm, λem=502 nm.Storage conditions: -20℃ protected from light, valid for 1 yearPrecautions●Staining concentration varies according to the type of cell and the number of cells in each well.● The prepared PKH67 mother liquor is very easy to dissolve. It is recommended to store in aliquots and freeze-dry at ≦-20℃.● PKH67 working solution should be prepared for immediate use, and cannot be prepared in advance, because PKH67 will decompose due to the absorption of water and affect the dyeing effect.● PKH67 is easily decomposed and will deteriorate quickly in the water solution. Please avoid contact with water during use of mother liquor. The working fluid is in contact with the water during the process of labeling the cells within the permitted time range.● PKH67 fluorescent dye is a DMSO solution. It will solidify and stick to the bottom, wall or cap of the tube at a lower temperature such as 4℃ and ice bath. After being taken out of the refrigerator, it will return to room temperature and become After the liquid is in the state, remove the cap from the bottom of the tube. It can be used after it has completely melted in a 37°C water bath.● The number of generations or time that can be traced after different cell types are marked is quite different. Please make a test based on the actual situation or reference documents.Instructions1. Staining solution preparation:(1) Take out the PKH67 reagent from the refrigerator, let it stand for a few minutes to room temperature, or after a 37°C water bath, leave the tube containing PKH67, and be sure to leave the tube for a few minutes before opening the lid to allow the reagent to fully fall into the tube The lid can only be opened after the bottom.(2) According to the number of cell samples to be tested, dilute the probe 10 times with the diluent, and then use a suitable solution (such as non-clear medium, HBSS or PBS) to dilute the PKH67 mother liquor 25 times to prepare a stain Work fluid. The best working solution concentration should be adjusted according to different cells and your own experimental system. Generally, the cells can be diluted 250 times according to the final concentration of the mother liquor in the kit. Some cells may need to increase the concentration appropriately.2. Cell staining(1) Resuspend the prepared cells to be tested in 100µl of staining solution to a cell concentration of about 107/ml. You can also perform in-situ staining, as long as the staining solution is enough to cover the cells.(2) Culture the cells at 2~8℃ for 15~30 minutes. The best culture time is different for different cells.It is recommended to incubate the labeled cells in the staining solution at 37°C for 5 minutes, and then at 4°C for 15 minutes.Low-temperature incubation can reduce the endocytosis of the dye by the cells, help the dye to label the plasma membrane, and reduce the possibility of the dye localizing to cytoplasmic vesicles.(3) After separation, remove the supernatant, collect the cells, wash the cells 1-2 times with PBS or non-clear medium, and finally add PBS or non-clear medium to resuspend the cells.(4) Take 500µl of cell suspension and test with flow cytometer. Ex/Em=490/502nm.(5) Subsequently, the cells can be cultured according to the normal culture method.(6) The labeling effect can be directly observed under a fluorescence microscope, or the cell proliferation can be detected by a flow cytometer after an appropriate period of culture, or used for cell fluorescence traces for other specific experimental purposes... Read More | Inquire |