| Description | Inquire | Product content C665709Component50 TStorageC665709ABuffer CL45 mLRTC665709BBuffer CB (concentrate)60 mLRTC665709CBuffer GW1 (concentrate)13 mLRTC665709DBuffer GW2 (concentrate)15 mLRTC665709EBuffer EBL10 mLRTC665709FProteinase K100 mgRTC665709GProteinase K Storage Buffer5 mLRTC665709HSpin Columns DFProduct content C665709Component50 TStorageC665709ABuffer CL45 mLRTC665709BBuffer CB (concentrate)60 mLRTC665709CBuffer GW1 (concentrate)13 mLRTC665709DBuffer GW2 (concentrate)15 mLRTC665709EBuffer EBL10 mLRTC665709FProteinase K100 mgRTC665709GProteinase K Storage Buffer5 mLRTC665709HSpin Columns DF with Collection Tubes50 EA2-8℃C665709ICentrifuge Tubes (L-1.5 mL)50 EART Product IntroductionThis kit is suitable for the extraction of free DNA from fresh or frozen serum, plasma, lymph fluid and other cell-free body fluids.This kit adopts centrifugal adsorption columns that can specifically bind nucleic acids and a unique buffer system.After the sample is lysed, the free DNA binds to the silica gel membrane under high salt conditions, and the free DNA elutes from the silica gel membrane at low salt and high pH. The product can handle liquid samples of 0.1-1 ml, and the elution volume of the configured high-efficiency micro adsorption column can be as low as 20 µl. The purified DNA is of high yield and quality, with maximum removal of proteins, pigments, lipids, and other inhibitors, and the rate of free DNA yield is highly dependent on the type of samples, storage conditions, time, and inter-individual variations. The quality of free DNA obtained from purification is stable and reliable, and can be directly used in molecular biology experiments such as PCR, fluorescence quantitative PCR and second generation sequencing.Self-contained reagents: anhydrous ethanol, isopropanol.Pre-experiment Preparation and Important NotesAdd 5 ml of Proteinase K Storage Buffer to Proteinase K to dissolve it and store it at -20℃. Do not leave the prepared Proteinase K at room temperature for a long time.Repeated freezing and thawing of the sample should be avoided, as this can lead to a decrease in extraction.This kit can extract 0.1-1 ml of liquid samples.Before use, please check Buffer CL, Buffer CB for crystallization or precipitation, if there is any crystallization or precipitation, please re-dissolve Buffer CL, Buffer CB by incubation at 56℃ in a water bath.Before first use isopropyl alcohol should be added to Buffer CB according to the instructions on the reagent bottle label, mixed well, and labeled on the reagent bottle label.Before the first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle, mixed well, and labeled on the label of the reagent bottle.Preheat the water bath to 60°C before starting the experiment.The elution buffer Buffer EBL can be preheated to 60°C and used.Operation stepsAdd 20 µl of Proteinase K to the centrifuge tube (supplied).Add 200 µl of serum/plasma sample.Note: When the sample volume exceeds 200 µl, please increase the amount of Proteinase K, Buffer CL and Buffer CB reagents in equal proportions, and the specific amount of reagents added can be referred to the attached table.3. Add 160 µl Buffer CL, mix upside down and shake vigorously for at least 30 seconds.4. Incubate at 60°C for 30 minutes, during which time mixing was inverted several times.Note: Incubation of 200µl serum/plasma samples at 60°C for 10-15 minutes is sufficient.Add 360 µl of Buffer CB (check for addition of isopropanol before use) and shake until thoroughly mixed.Ice bath for 5 minutes and centrifuge briefly to concentrate the liquid on the walls and wall caps to the bottom of the tube.Add all of the solution obtained in step 6 to the adsorption columns (Spin Columns DF) that have been loaded into the collection tubes, and if the solution cannot be added all at once, it can be transferred in several times. centrifuge the columns at 12,000 rpm for 1 minute, pour off the waste solution from the collection tubes, and put the columns back into the collection tubes.Add 500µl of Buffer GW1 to the adsorbent column (check that anhydrous ethanol is added before use),centrifuge the column at 12,000rpm for 30 seconds, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.Add 750 µl Buffer GW2 to the adsorbent column (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 30 seconds, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.10. Add 750 µl of anhydrous ethanol to the adsorbent column and centrifuge at 12,000 rpm for 30 s. Pour off the waste liquid in the collection tube and put the adsorbent column back into the collection tube.11. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with the subsequent enzymatic reaction.12. Place the adsorption column in a new centrifuge tube, add 20-100 µl Buffer EBL or sterilized water to the middle part of the adsorption column overhanging the column, leave it at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20℃.Note: 1) If the downstream experiment is sensitive to pH, you can use sterilized water for elution. The pH value of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH value is 7.0-8.5 (you can use NaOH to adjust the pH value of water to this range), and the elution efficiency is not high when the pH value is lower than 7.0.2) Preheat the elution buffer BufferEBL to 60℃ and use it, and incubate it at room temperature for 5 minutes before centrifugation to increase the yield.3) If the final concentration of DNA is to be increased, the resulting solution can be reintroduced into the adsorption column and left at room temperature for 2-5 minutes and centrifuged at 12,000 rpm for 1 minute.4) Because DNA preserved in water will be affected by acidic hydrolysis, for long-term storage, it is recommended to elute it with Buffer EBL and store it at -20℃.Table: Recommended reagent additions for different sample sizes... Read More | N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917D DNA Standard B 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917E DNA Standard C 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917F DNA Standard D 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917G DNA Standard E 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis is a dye-based (SYBR Green I) qPCR NGS library quantification kit for cfDNA, which provides the reaction mixture, DNA primer mixture, standards, and sample dilutions required for the qPCR process, making it a complete reagent system that is easy and convenient to use. The fluorescent dye SYBR Green I contained in the reaction mixture binds to all double-stranded DNA. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, the length of the standard in the kit (about 270bp) is comparable to the average length of the cfDNA NGS libraries (250-300bp), which is able to quickly and accurately quantitate the concentration of the constructed cfDNA libraries. quantification.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.NOTE: High Rox and Low Rox are formulated as described in Method of Use 2.Applicable scopeThis product is designed for the absolute quantification of the concentration of Illumina platform second generation sequencing libraries. The end of the library contains Illumina P5 and P7 microarray binding sequences, the length of which does not exceed 1kb, and the concentration is not less than 0.02pM can be used for quantitative experiments. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-60 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR MasterMix10 µlqPCR Primer Mix0.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: 1 µl High Rox per 50 µl of reaction system; Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.3.qPCR reaction programIf the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.Refer to the specific instrument setup program for dissolution curves.data analysisStandard curve productionThe standard curve was plotted according to the data processing Excel sheet. The correlation coefficient R2 of the standard curve should be not less than 0.99, and the slope should be located between -3.1 and -3.6 when the Ct value is the longitudinal coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard A60 pMDNA Standard B6 pMDNA Standard C0.6 pMDNA Standard D0.06 pMDNA Standard E0.006 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More | This plant protein extraction kit can extract soluble plant proteins from fresh, frozen, or dried plant tissues. Suitable for protein extraction from various plants and different parts of plants (such as roots, stems, leaves, flowers, seeds, etc.), with high extraction efficiency, high protein yieldThis plant protein extraction kit can extract soluble plant proteins from fresh, frozen, or dried plant tissues. Suitable for protein extraction from various plants and different parts of plants (such as roots, stems, leaves, flowers, seeds, etc.), with high extraction efficiency, high protein yield, high activity, and fast speed. The extracted protein can be directly subjected to protein electrophoresis analysis, immunoprecipitation, Western Blot, protein activity determination, and protein purification experiments. The concentration of the extracted protein can be determined using the BCA protein quantification kit. P665757Component100 TStorageP665757APlant Protein Extraction Reagent100 mLRTP665757BProtease Inhibitor Cocktail (100×)1 mL-20℃. Avoid freeze/thaw cycle. Precautions:1. This product contains 1mM EDTA.2. To prevent protein degradation, all operations should be carried out on ice as much as possible.3. After extracting protein using this product, the BCA method can be used for protein quantification.4. To achieve the best experimental results, please adjust the optimal usage amount according to the experiment.Operation steps:1. Please remove the required Plant Protein Extraction Agent for pre cooling before protein extraction.2. Weigh the weight of the experimental plant tissue. Add 5 ml of Plant Protein Extraction Agent to 1 g of tissue (add Protein Inhibitor Cocktail in a 1:99 ratio before protein extraction).Attention:1) Before homogenization, cut large pieces of plant tissue into small pieces and homogenize them with a mechanical homogenizer for 10 seconds, with an interval of 10 seconds. Repeat the process three times and select the appropriate homogenization method according to the different tissue samples.2) The amount of lysate used is adjusted according to different parts of the plant. If concentrated protein extracts are needed, the amount of Plant Protein Extraction Agent used can be appropriately reduced.3. After homogenization, incubate on ice for 20-30 minutes.4.4 ℃ 13400 × g, centrifuge for 20 minutes.5. Collect soluble proteins from the supernatant for further purification or downstream analysis... Read More | This reagent kit is specially developed for one-step RT-PCR experiments. Reverse transcription and PCR are carried out in the same reaction system, without the need to add reagents or open the tube cap during the reaction process, which improves detection sensitivity and experimental efficiency This reagent kit is specially developed for one-step RT-PCR experiments. Reverse transcription and PCR are carried out in the same reaction system, without the need to add reagents or open the tube cap during the reaction process, which improves detection sensitivity and experimental efficiency while avoiding contamination. This kit includes a brand new high-efficiency reverse transcriptase, a fast hot start DNA polymerase, as well as reaction buffer suitable for reverse transcription and PCR amplification, and other components necessary for the experiment. The loss of activity of SuperRT reverse transcriptase RNase H reduces RNA degradation in reverse transcription reactions. This reverse enzyme has high reverse transcription efficiency and can perform good reverse transcription reactions on a small amount of RNA templates. The rapid hot start DNA polymerase used in PCR reaction has excellent performance of high amplification efficiency, strong specificity, and fast extension speed. The unique buffering system maximizes the efficiency of both reverse transcriptase and polymerase. The target product amplified using this reagent kit has an A base attached to the 3 'end, which can be directly used for T/A cloning.S665660Component100 TStorageS665660ASuperRT OneStep EnzymeMix50 µL-20℃. Avoid freeze/thaw cycle.S665660B2×SuperRT OneStep Buffer1.4 mL-20℃. Avoid freeze/thaw cycle.S665660CRNase-Free Water1.5 mL-20℃. Avoid freeze/thaw cycle. Notes:1. During the operation process, RNase contamination should be avoided to prevent RNA degradation or cross contamination during experiments. It is recommended to perform RNA operations in specialized areas, use specialized instruments and consumables, and have operators wear masks and disposable gloves, and frequently change gloves.2. Disposable plastic containers should be used as much as possible for experiments. If glass containers are used, they should be treated with a 0.1% DEPC (diethyl pyrocarbonate) aqueous solution at 37 ℃ for 12 hours, and sterilized under high pressure at 120 ℃ for 30 minutes before use. Alternatively, glass containers should be sterilized under dry heat at 180 ℃ for 60 minutes before use. The sterile water used in the experiment should be treated with 0.1% DEPC and then subjected to high-pressure sterilization.3. All reagents in this reagent kit should be gently mixed upside down before use, avoiding foaming as much as possible, and used after brief centrifugation. The enzymes involved should be returned to -20 ℃ as soon as possible after use to avoid repeated freeze-thaw cycles.4. This reagent kit must use specific primers, and the selection of primers can be based on specific experiments. The quality of primer design directly affects the results of RT-PCR reactions. When designing primers, factors such as GC content, primer length, primer position, and the secondary structure of PCR products need to be considered. It is recommended to use professional primer design software.Usage:1. Dissolve the RNA template, primers, OneStep RT-PCR Buffer, SuperRT OneStep RT-PCR EnzymeMix, and RNase Free Water and place them on ice for later use.2. Prepare the reaction system according to the following table: Reagent 25 µlReaction system Final concentration 2×SuperRT OneStep Buffer 12.5 µl 1× Forward Primer,10 µM 1 µl 0.4 µM Reverse Primer,10 µM 1 µl 0.4 µM SuperRT OneStep EnzymeMix 0.5 µl / RNA Template X µl 1 pg – 1 µg RNase-Free Water up to 25 µl / Attention: The primer concentration should be between 0.1 and 1.0 as the final concentration µ M serves as a reference for setting the range. In the case of low amplification efficiency, the concentration of primers can be increased; When non-specific reactions occur, the primer concentration can be reduced to optimize the reaction system.3. Vortex and shake well, centrifuge briefly, and collect the solution to the bottom of the tube.4. Preheat the thermal cycler to 45 ℃, place the PCR tube in the thermal cycler, and perform RT-PCR reaction.Reaction conditions: Step Temperature Time / Reverse transcription 45℃ 30 min / PCR pre denaturation 95℃ 2 min Denaturation 94℃ 30 s 30-40 cycles Anneal 55-65℃ 30 s 30-40 cycles Extend 72℃ 30 s 30-40 cycles Finally extended 72℃ 5 min /Attention:1) In general PCR experiments, the annealing temperature is 5 ℃ lower than the melting temperature Tm of the amplification primer, and the annealing time is generally 20-30 seconds. If the ideal amplification efficiency cannot be achieved, the annealing temperature should be appropriately reduced; When non-specific reactions occur, increase the annealing temperature to optimize the reaction conditions.2) The extension time is set based on the size of the amplified fragments, and the DNA Polymerase amplification efficiency contained in this product is 1 kb/30s.3) The number of cycles can be set based on the downstream application of the amplification product. Too few cycles, insufficient amplification; Multiple cycles increase the probability of mismatches and result in severe non-specific backgrounds. Therefore, while ensuring product yield, the number of cycles should be minimized as much as possible.5. After the reaction is complete, take 5 µ l of the reaction product, add an appropriate amount of loading buffer, and perform electrophoresis detection results... Read More |