| Description | Inquire | Product content:D665967Component200 TStorageD665967ABuffer PB120 mLRTD665967BBuffer PS60 mLRTD665967CBuffer PW (concentrate)25 mLRTD665967DBuffer EB30 mLRTD665967ESpin Columns DM with Collection Tubes200 EART Product Introduction: This reagent kit adopts a new silicon-based membrane technology and Product content:D665967Component200 TStorageD665967ABuffer PB120 mLRTD665967BBuffer PS60 mLRTD665967CBuffer PW (concentrate)25 mLRTD665967DBuffer EB30 mLRTD665967ESpin Columns DM with Collection Tubes200 EART Product Introduction: This reagent kit adopts a new silicon-based membrane technology and reagent formula. Through a rapid and simple three-step process of binding, washing, and elution, 100 bp-10 kb DNA fragments can be purified and recovered from PCR products or enzyme reaction solutions (enzyme cutting, linking, probe labeling, etc.). Each adsorption column can adsorb up to 10 kb of DNA fragments µ G DNA, while minimizing impurities such as primers, oligonucleotides, enzymes, etc. The purified and recovered DNA has high purity and concentration, good integrity, and high recovery rate, and can be directly used for molecular biology experiments such as sequencing, linking and transformation, labeling, and in vitro transcription.Self prepared reagent: anhydrous ethanol.Preparation and important precautions before the experiment:1. All components can be stably stored in a dry, room temperature (15-30 ℃) environment for 1 year, and can be stored at 2-8 ℃ for longer periods of time. When the solution is stored at low temperature, it should be left at room temperature for a period of time before use, and then restored to room temperature before use.2. This reagent kit can selectively recover all DNA fragments from the solution. If you need to selectively recover specific fragments while removing other fragments of different sizes, please choose our company's gel recovery reagent kit.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in the Buffer PB. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. The recovery efficiency is related to the initial amount of DNA and the elution volume. The smaller the initial amount, the smaller the elution volume, and the lower the recovery rate.6. All centrifugation steps can be performed at room temperature.Operation steps:1. Estimate the volume of DNA reaction solution, add 5 times the volume of Buffer PB, and mix thoroughly (without removing paraffin or mineral oil).Note: 1) If the DNA reaction system is 50 µ l (excluding paraffin oil volume), add 250 µ l Buffer PB.2) After adding Buffer PB, check the pH value of the solution. If the pH value is greater than 7.5, add 10-30 to it µ 3 M sodium acetate (pH 5.0) was used to adjust the pH value to 5-7.2. Column balance: Add 200 to the spin columns DM that have been loaded into the collection tube µ Centrifuge at 13000 rpm (~16200 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.3. Add the solution obtained in step 1 to the adsorption column that has been loaded into the collection tube, let it stand at room temperature for 1 minute, centrifuge at 13000 rpm for 30-60 seconds, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.Attention: The volume of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ l, it can be added in batches.4. Add 500 µ l of Buffer PW to the adsorption column (please check if anhydrous ethanol has been added before use), centrifuge at 13000 rpm for 30-60 seconds, discard the waste liquid in the collection tube, and place the adsorption column in the recovery tube.Note: If purified DNA is used for salt sensitivity experiments (such as flat end ligation experiments or direct sequencing), it is recommended to add Buffer PW and let it stand for 2-5 minutes before centrifugation.5.13000 rpm for 1 minute and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.). To ensure that downstream experiments are not affected by residual ethanol, it is recommended to open the cover of the adsorption column and place it at room temperature for a few minutes to thoroughly dry the residual ethanol in the adsorbent material at the bottom.6. Place the adsorption column into a new centrifuge tube (provided by oneself), add 30-50 µ l Buffer EB to the middle position of the adsorption membrane by hanging droplets, and let it stand at room temperature for 1 minute. Centrifuge at 13000 rpm for 1 minute and collect DNA solution- Store DNA at 20 ℃.Attention:1) The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (the pH value of water can be adjusted to this range using NaOH).2) To improve the recovery of DNA, the solution obtained by centrifugation can be added back to the adsorption column, left at room temperature for 2 minutes, and centrifuged at 13000 rpm for 1 minute.3) The elution volume should not be less than 30 µ l. A small volume will affect the recovery efficiency... Read More | Product content: M665559Component50 TStorageM665559ABuffer GTT15 mLRTM665559BBuffer GL15 mLRTM665559CBuffer GW1(concentrate)13 mLRTM665559DBuffer GW2(concentrate)15 mLRTM665559EBuffer GE15 mLRTM665559FProteinase K1.25 mLRTM665559GSpin CoLumns DM with CoLLection Tubes50 Product content: M665559Component50 TStorageM665559ABuffer GTT15 mLRTM665559BBuffer GL15 mLRTM665559CBuffer GW1(concentrate)13 mLRTM665559DBuffer GW2(concentrate)15 mLRTM665559EBuffer GE15 mLRTM665559FProteinase K1.25 mLRTM665559GSpin CoLumns DM with CoLLection Tubes50 EART Product Introduction:This reagent kit is suitable for extracting high-purity total DNA from fresh or frozen mouse or rat tails. The method provided by this reagent kit is simple and feasible, and the purification process does not require phenol or chloroform extraction. It can obtain DNA fragments up to 50 kb, and can also effectively recover fragments of 100 bp. This reagent kit uses a unique lysis solution to effectively lyse mouse tail samples. The optimized buffer system efficiently binds the DNA generated after the lysis of mouse tail to the silica matrix adsorption column, while other pollutants can flow through the membrane; Inhibitors of PCR and other enzymatic reactions can be effectively removed through a two-step washing process, followed by washing with low salt buffer or water to obtain high-purity DNA. The purified DNA can be directly used for downstream experiments such as enzyme digestion, PCR, ReaL Time PCR, library construction, Southern BLot, and molecular labeling.Self prepared reagent: anhydrous ethanol.Preparation and important precautions before the experiment:1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.Before the first use, anhydrous ethanol should be added to BufferGW1 and BufferGW2 according to the instructions on the reagent bottle label.3. Before use, please check if there is any crystallization or precipitation in the Buffer GL. If there is any crystallization or precipitation, please dissolve the Buffer GL again in a 56 ℃ water bath.Operation steps:1. Take a tail of a rat or two mice with a length of 0.4-0.6 cm, grind it into fine powder in liquid nitrogen or cut it into pieces and place it in a centrifuge tube (provided by oneself). Join 180 µ L Buffer GTT, shake and mix well. Note: Ensure that the starting quantity of the organization does not exceed the recommended range.2. Add 20 µ L Protein K, vortex oscillation, thoroughly mix.3. Place in a 56 ℃ water bath until the tissue solution is completely clear. Generally, digestion is required for 6-8 hours. During the incubation process, vortex oscillation is required to evenly disperse the sample. Note: 1) If there is still gel like substance after incubation and vortex oscillation, digest overnight or add 20 more if necessary µ L Protein K digestion will not affect subsequent operations. 2) To remove RNA, add 4 after completing the above steps µ L 100 mg/mL RNase A solution, shake well and let stand at room temperature for 5-10 minutes.4.12000 rpm (~13400 × g) for 1 minute to remove undigested tissues similar to mouse hair. Transfer the supernatant to a new centrifuge tube (provided by oneself).5. Add 200 µ L Buffer GL, vortex oscillation, thoroughly mixed. Join 200 µ L anhydrous ethanol, vortex and shake, thoroughly mix. Short centrifugation allows the solution on the tube wall to be collected to the bottom of the tube.Attention: 1) After adding Buffer GL and anhydrous ethanol, immediately vortex and shake to mix well.2) If multiple samples are operated together, Buffer GL and anhydrous ethanol can be mixed in equal proportions and added to the samples together.3) The addition of Buffer GL and anhydrous ethanol may produce white precipitates, which will not affect subsequent experiments.6. Add all the solutions obtained in step 5 to the adsorption column (Spin CoLumins DM) that has been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.8. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Note: To further improve DNA purity, repeat step 8.9.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).10. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Note: 1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high.2) Incubating at room temperature for 5 minutes before centrifugation can increase yield.3) Use an additional 50-200 µ Re washing with L Buffer GE or sterilized water can increase yield.4) If you want to increase the final concentration of DNA, you can add the DNA eluent obtained in step 10 back onto the adsorption membrane and repeat step 10; If the elution volume is less than 200 µ L. It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ L Buffer GE or off... Read More | This kit is suitable for extracting total RNA from fresh whole blood (blood samples treated with anticoagulants such as citrate, EDTA, or heparin). It can process up to 1.5 ml of whole blood and elute to obtain high-purity RNA with a molecular weight greater than 200 bp. Multiple samples can be This kit is suitable for extracting total RNA from fresh whole blood (blood samples treated with anticoagulants such as citrate, EDTA, or heparin). It can process up to 1.5 ml of whole blood and elute to obtain high-purity RNA with a molecular weight greater than 200 bp. Multiple samples can be completed simultaneously within 1 hour. This product does not require the ultra centrifugation step of CsCl purification and LiCl or ethanol precipitation. It does not contain toxic solvents such as phenol or chloroform. The purified RNA effectively removes enzyme inhibitors and pollutants such as heme and heparin. It can be directly used in various molecular biology routine experiments, such as RT-PCR, Northern Blot, Dot Blot, in vitro translation, and so on.Self prepared reagents: β- Mercaptoethanol, 70% ethanol (prepared with water without RNase), anhydrous ethanol. R666034 Component 50 T Storage R666034A Buffer RBL (10×) 60 mL RT R666034B Buffer RL 35 mL RT R666034C Buffer RW1 40 mL RT R666034D Buffer RW2 (concentrate) 11 mL RT R666034E RNase-Free Water 10 mL RT R666034F Spin Columns FL with Collection Tubes 50 sets RT R666034G Spin Columns RM with Collection Tubes 50 sets RT R666034H RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RT Preparation and important precautions before the experimentTo prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The sample should avoid repeated freezing and thawing, otherwise it will affect the yield and quality of RNA extraction. The sample can be stored in Buffer RL at -70 ℃ for one month.3. Before use, please check if there is any crystallization or precipitation in the Buffer RL. It can be dissolved again in a 56 ℃ water bath. Please add Buffer RL before use β- Mercaptoethanol, with a final concentration of 1%. Add 10 to 1 ml Buffer RL µ L β- Mercaptoethanol. join β- The buffer RL room temperature of mercaptoethanol can be stored for one month.4. Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. This reagent kit cannot be used for RNA extraction from frozen blood samples with anticoagulants added.6.10 × Buffer RBL needs to be diluted 10 times with water without RNase before use, and then stored at 2-8 ℃ after dilution.7. If downstream experiments are highly sensitive to DNA, it is recommended to treat RNA with DNase I that does not contain RNase.8. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Operation steps1. Add 5 times the volume of 1 x Buffer RBL to fresh anticoagulant whole blood samples of 0.5-1.5 ml (please dilute 10 x Buffer RBL with RNase free water before use), gently vortex or invert and mix well. Incubate on ice for 10-15 minutes, mix twice during the incubation process.Attention: During the incubation process, the cloudy suspension will become transparent, indicating that red blood cells have been lysed. If necessary, the incubation time can be extended to 20 minutes. 2. Centrifuge at 4 ℃, 2100 rpm (~400 × g) for 10 minutes, and carefully discard the supernatant.3. Add 2 times the volume of the blood sample to the above precipitate with 1 x Buffer RBL (please dilute 10 x Buffer RBL with RNase free water before use), gently vortex, and resuspend the precipitate thoroughly. 4. Centrifuge at 4 ℃ and 2100 rpm for 10 minutes, carefully and thoroughly remove the supernatant.Note: This step must completely remove the supernatant, otherwise it will affect the lysis and lead to a decrease in RNA production.5. Add Buffer RL to the precipitate (check if it has been added before use β- Mercaptoethanol, 0.5-1.5 ml of blood sample added to 600 µ L Buffer RL, or less than 0.5 ml of blood sample added to 350 µ L Buffer RL, mix well.6. Transfer the obtained liquid to the spin columns FL that have been loaded into the collection tube, centrifuge at 12000 rpm (~13400 × g) for 2 minutes, collect the filtrate, and discard the filter column.7. Add 1 volume (600) to the obtained filtrate µ L or 350 µ l) Mix 70% ethanol (prepared without RNase water) well.Attention: Adding ethanol may cause precipitation and will not affect subsequent experiments.8. Add all the solution obtained in the previous step to the spin columns RM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred in multiple batches. Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.9. Add 700 to the adsorption column µ Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.Optional steps: If conducting RNA experiments that are highly sensitive to trace amounts of DNA, replace step 9 with the following steps.1) Add 350 to the adsorption column µ Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.2) Preparation of DNase I mixture: Take 70 µ Reaction Buffer and 10 µ L DNase I storage solution, gently mix and prepare to a final volume of 80 µ The reaction solution of L.Attention: The above system is configured according to our company's DNase I (D665537) reaction system. Please refer to the corresponding manual for other company products.1) Add 350 to the adsorption column µ Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.2) Preparation of DNase I mixture: Take 70 µ Reaction Buffer and 10 µ L DNase I storage solution, gently mix and prepare to a final volume of 80 µ The reaction solution of L.Attention: The above system is configured according to our company's DNase I (D665537) reaction system. Please refer to the corresponding manual for other company products.3) Add 80 µ l of the prepared DNase I reaction solution directly to the adsorption column and incubate at 20-30 ℃ for 15 minutes.4) Add 350 to the adsorption column µ Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.10. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 15 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.11. Repeat step 10. 12. Centrifuge at 12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).13. Place the adsorption column in a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 13 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 13... Read More | Products content S666097Component200 TStorageS666097A5×SuperFast One Step RT-qPCR U+ Buffer1 mL-20℃. Avoid freeze/thaw cycle.S666097BSuperFast One Step U+ Enzyme200 µL-20℃. Avoid freeze/thaw cycle.S666097CRNase-Free Water2×1.5 mL-20℃. Avoid freeze/thaw cycle. Products content S666097Component200 TStorageS666097A5×SuperFast One Step RT-qPCR U+ Buffer1 mL-20℃. Avoid freeze/thaw cycle.S666097BSuperFast One Step U+ Enzyme200 µL-20℃. Avoid freeze/thaw cycle.S666097CRNase-Free Water2×1.5 mL-20℃. Avoid freeze/thaw cycle. Products IntroductionThe SuperFast Probe One Step RT-qPCR U+ Kit is designed for quantitative PCR assays using RNA as a template (e.g., RNA viruses). Using gene-specific primers (GSP), reverse transcription and qPCR reactions are completed in a single tube, eliminating the need for additional tube-opening/pipetting operations, greatly increasing throughput and reducing the risk of contamination. The dUTP/UNG anti-contamination system is introduced in this kit. The heat-sensitive UNG rapidly degrades U-containing contaminants at room temperature; it is rapidly inactivated by reverse transcription at 55°C, without affecting the efficiency and sensitivity of qRT-PCR. Combined with optimized buffer systems and antibody-modified Taq enzymes and mutated M-MLV, the SuperFast Probe One Step RT-qPCR U+ Kit provides sensitivity up to 0.1 pg of total RNA or <10 copies of RNA template and enhanced thermal stability. 5× SuperFast One Step RT-qPCR U+ Buffer contains the following components The 5× SuperFast One Step RT-qPCR U+ Buffer contains an optimized buffer system and dNTP/dUTP Mix, which is particularly suitable for high specificity, low template concentration and multiplexed rapid detection of fluorescently labeled probes such as TaqMan. caveatBefore use, please mix the product gently by turning it up and down after it is completely melted to avoid foaming, and use it after brief centrifugation. Avoid repeated freezing and thawing of the product.ROX dye is used to correct the fluorescence signal error between the quantitative PCR wells, this product does not contain ROX dye, if you need to match the ROX dye with the instrument you are using, please contact your local business or call CombiSense customer service at 4006-222-360. PCR reaction system Attention: (1) Usually, the final primer concentration of 0.2 µM can get better results, and 0.1-1.0 µM can be used as a reference for setting the range. If the amplification efficiency is not high, the concentration of primer can be increased; if non-specific reaction occurs, the concentration of primer can be decreased to optimize the reaction system.(2) The final concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, please refer to the instrument manual or the specific requirements for the use of each fluorescent probe to adjust the concentration.3) Because templates from different species contain different numbers of copies of the target gene, the template can be diluted in a gradient to determine the optimal amount of template to usePCR reaction conditionsmovetemptimingcirculatereverse transcription55°C1 min1premutability95°C10s1)1denaturation95°C1 s40-45Annealing/Extension55-60°C2)10-15s3)40-45Attention: (1) The enzyme used in this product is activated under the condition of pre-denaturation at 95℃ for 30s. Under this condition, most of the templates can be well unchained. For templates with high GC content and complex secondary structure, the pre-denaturation time can be extended to 1min, so as to make the starting template fully unchained, and if the high temperature treatment time is too long, it will affect the activity of the enzyme; for simple templates, pre-denaturation time of 1-10s can also be used, and the optimal pre-denaturation time can be determined according to the template situation.(2) It is recommended to use two-step PCR reaction program, the annealing temperature should be 55-60℃ as the reference range, and the annealing temperature can be increased when non-specific reaction occurs. If you can't get good results due to the use of primers with low Tm values or long amplification products, you can try three-step PCR amplification.3) Whether the actual Real Time PCR instrument used supports rapid amplification cycles, please perform a pre-experiment to verify this for the first attempt... Read More |