| Description | Inquire | This reagent kit is for research purposes only. Purpose of use: This reagent kit is used to determine the content of lactose in serum, plasma, and related liquid samples.Experimental principle:This kit applies enzyme-linked immunosorbent assay to determine the level of lactose in the sample. This reagent kit is for research purposes only. Purpose of use: This reagent kit is used to determine the content of lactose in serum, plasma, and related liquid samples.Experimental principle:This kit applies enzyme-linked immunosorbent assay to determine the level of lactose in the sample. Purified lactose antibodies were coated on a microplate to produce solid-phase antibodies. Lactose was added to the microplate of the coated monoclonal antibody, along with HRP labeled lactose antigens, to compete for binding. After thorough washing, the substrate TMB was added for colorimetry. The depth of sample color is negatively correlated with the content of lactose in the sample. Measure the absorbance (OD value) at a wavelength of 450nm using an enzyme-linked immunosorbent assay (ELISA) reader, and calculate the content of lactose in the sample through a standard curve.Kit composition:130times concentrated washing solution20ml×1 bottle8.1Standard S1(80µg/L)0.5ml×1bottle2Enzyme-linked immunosorbent assay6ml×1 bottle8.2Standard S2(40µg/L)0.5ml×1bottle3Enzyme labeling coated plate96 holes x 1 pieces8.3Standard S3(20µg/L)0.5ml×1bottle4Color reagent A solution6ml×1 bottle8.4Standard S4(10µg/L)0.5ml×1bottle5Color developer B solution6ml×1 bottle8.5Standard S5(5µg/L)0.5ml×1bottle6Stop solution6ml×1 bottle9Instructions1 copy7Sample Diluent6ml×1 bottle10Microplate Sealers2 sheetsSpecimen requirements:1. Specimen processing:(1) After collecting the water sample, it is repeatedly freeze-thawed three times at -20 ℃, and then filtered through glass fiber for future reference(2) The tissue samples should be extracted using butanol: methanol: water (5:25:70 V: V: V), or extracted according to relevant literature. The experiment should be conducted as soon as possible after extraction. If the experiment cannot be conducted immediately, the specimen can be stored at -20 ℃ for future reference2. Samples containing NaN3 cannot be detected as NaN3 inhibits the activity of horseradish peroxidase (HRP).Operation steps:1. Sample addition: Set up standard wells, blank wells (blank control wells do not include samples and enzyme-linked immunosorbent assay reagents, the other steps are the same), and sample wells to be tested. Add 50 microliters to the standard well on the enzyme-linked immunosorbent assay (ELISA) plate, and first add 40 diluents to the sample well to be tested µ l. Then add 10 more samples to be tested µ L (The final dilution of the sample is 5 times). Add the sample to the bottom of the enzyme-linked immunosorbent assay (ELISA) plate well, avoiding touching the well wall as much as possible. Gently shake and mix well.2. Enzyme addition: Add 50 enzyme labeled reagents to each well µ l. Excluding blank holes.3. Warm incubation: Seal the plate with a sealing film and incubate at 37 ℃ for 60 minutes.4. Solution preparation: Dilute 30 times the concentrated washing solution with distilled water and set aside for later use5. Washing: Carefully remove the sealing film, discard the liquid, shake dry, fill each well with washing solution, let it stand for 30 seconds, then discard. Repeat this process 5 times and pat dry.6. Color development: Add color development agent A50 to each well first µ l. Add color developer B50 again µ l. Gently shake and mix well, and develop color at 37 ℃ in the dark for 15 minutes7. Termination: Add 50% termination fluid to each hole µ l. Terminate the reaction (at this point, the blue color immediately turns yellow).8. Measurement: Zero the blank hole and sequentially measure the absorbance (OD value) of each hole at a wavelength of 450nm. The measurement should be conducted within 15 minutes after adding the termination solution.Calculation:Draw a standard curve on a coordinate paper with the concentration of the standard substance as the x-axis and the OD value as the y-axis. Based on the OD value of the sample, determine the corresponding concentration from the standard curve; Multiply it by the dilution factor; Alternatively, a linear regression equation can be used to calculate the standard curve using the concentration and OD value of the standard substance. The OD value of the sample can be substituted into the equation to calculate the sample concentration, which is then multiplied by the dilution factor to obtain the actual concentration of the sample.Notes:1. The kit should be balanced at room temperature for 15-30 minutes before use when taken out from the cold storage environment. If the enzyme coated plate is not used up after opening, the Flat noodles should be stored in a sealed bag.2. Concentrated detergent may precipitate crystals. When diluted, it can be heated in a water bath to aid in dissolution. Washing does not affect the results.3. A sampler should be used for each step of sample addition, and its accuracy should be regularly calibrated to avoid experimental errors. It is best to control the sample addition time within 5 minutes. If there are a large number of specimens, it is recommended to use a firing gun for sample addition.4. Please make a standard curve at the same time as each measurement, preferably with a re hole. If the content of the substance to be tested in the sample is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please dilute the sample diluent by a certain multiple (n times) before measurement. When calculating, please multiply the total dilution multiple (x n x 5).5. The sealing film is only for one-time use to avoid cross contamination.6. Please store the substrate in dark.7. Strictly follow the instructions and determine the test results based on the reading of the enzyme-linked immunosorbent assay (ELISA) reader8. All samples, washing liquids, and various waste should be treated as infectious substances.9. The components of this reagent with different batch numbers shall not be mixed.Detection range:two µ G/L-90 µ G/L... Read More | Products content Products IntroductionThis kit is a dedicated sample preparation solution for microbiome analysis and is suitable for the purification and enrichment of genomic DNA of pathogenic microorganisms such as bacteria and fungi from mixed samples such as swabs, blood, sputum, alveolar Products content Products IntroductionThis kit is a dedicated sample preparation solution for microbiome analysis and is suitable for the purification and enrichment of genomic DNA of pathogenic microorganisms such as bacteria and fungi from mixed samples such as swabs, blood, sputum, alveolar lavage, etc. During the purification process, differential lysis of the host cells and subsequent enzymatic digestion can effectively remove most of the host DNA while providing a comprehensive coverage of the bacterial and fungal DNA loci to a higher level. By differential lysis of host cells and subsequent enzymatic digestion, this kit can effectively remove most of the host DNA while maximizing the full coverage of bacterial, fungal and other pathogenic microbial DNA sites, thus obtaining microbiome DNA enrichment products with a higher coverage. Microbial DNA purified with this kit is suitable for a variety of downstream applications, including whole genome sequencing analysis, 16S rDNA-based high sensitivity microbiome analysis, and macrogenomic birdshot sequencing analysis. Self-contained reagents and consumablesSterile pipette tips with aerosol barrier to prevent cross-contamination anhydrous ethanol Microcentrifuge tubes (2 ml/1.5 ml) PBS buffer (required for some samples only)Pre-experiment Preparation and Important Notes1. Add 1.25 ml Proteinase K Storage Buffer to Proteinase K and store at -20℃. Do not leave the prepared Proteinase K (20 mg/ml) at room temperature for a long time, and avoid repeated freezing and thawing to avoid affecting its activity.2. Dissolve Lysozyme (100 mg) in 10 ml Enzymatic Lysis Buffer to a final concentration of 10 mg/ml, dispense into sterile tubes and store at -20℃. Do not leave the prepared Lysozyme (10 mg/ml) at room temperature for a long time and avoid repeated freezing and thawing to avoid affecting its activity.3. Thaw Buffer GB1 and Buffer GB2 at room temperature or 2-8°C before use and mix thoroughly. Thawed Buffer GB1 and Buffer GB2 can be left at 2-8°C for 1-2 weeks without affecting their activity, and should be stored at -20°C for long term storage. To ensure optimal performance, do not freeze or thaw more than three times. If less than one bottle of Buffer GB1 and Buffer GB2 is required for a single extraction, ensure that it is used under sterile conditions such as an ultra-clean bench and avoid microbial contamination and growth in the remaining buffer.4. Before first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the vial label and labeled.5. Check Buffer GL for crystallization or precipitation before use, and if crystallization or precipitation occurs, redissolve Buffer GL in a 56°C water bath.6. If the downstream experiments are sensitive to RNA contamination, 4 µl of DNase-Free RNase A (100 mg/ml) can be added before adding Buffer GL. RNase A is not provided in the kit, but can be ordered separately from CW0601S.7. This kit is designed for the isolation of DNA from intact microbial cells. To ensure optimal recovery of microbial DNA, samples should be fresh. If storage or transportation is required, this should preferably be done at 2-8°C and not frozen or thawed, as freezing and thawing can damage the integrity of the microbial cells and therefore result in the loss of exposed microbial DNA during host DNA removal.8. To avoid false results due to contamination, keep the work area clean, wear protective clothing, and set up controls for quality control. Use appropriate measures to handle sample materials to minimize the risk of cross-contamination. During the extraction process, use DNA-free pipette tips and consumables, and cap reagents immediately after use to prevent contamination. procedure1. Sample pre-treatment: 1a: For swab samples, swirl the swab portion of the swab in 0.5 ml PBS for at least 20 s. Squeeze the swab several times against the wall of the tube before removing it so that as much of the bacterial fluid as possible can be squeezed out of the swab to minimize sample loss. 1b: For viscous samples, e.g. sputum, take ~500 µl of sample, add 1.5 times the volume (~750 µl) of Buffer GB1 and incubate at 37°C, 600 rpm for 15-30 min until the sample is completely liquefied.Note: The sample volume can be increased or decreased appropriately and the amount of Buffer GB1 added adjusted accordingly.1c: For alveolar lavage fluid containing a small amount of viscous sputum, centrifuge as much of the alveolar lavage fluid as possible, carefully remove the supernatant, and retain the lower viscous fraction (containing sputum, cells, and organisms), add 1.5 times the volume of Buffer GB1, and incubate for 15-30 min at 37°C, 600 rpm until the sample is completely liquefied.1d: For non-viscous body fluid samples such as blood and cerebrospinal fluid, liquefaction treatment is not required, and an appropriate amount of sample is taken directly, the operation of step 2 is carried out, and the cell precipitate is collected by centrifugation.2. Centrifuge at 10000 rpm for 5-10 min at room temperature and carefully discard the supernatant.Note: Do not disturb the lower cell sediment to avoid sample loss.3. Add 500 µl Buffer GB2, vortex to mix, and incubate at room temperature, 600 rpm for 10 min. 4. Centrifuge at 12000 rpm for 2 min and carefully remove the supernatant.Note: Do not disturb the bacterial precipitate when removing the supernatant to avoid sample loss.5. Add 200 µl of Buffer GB2 to the precipitate, add 2 µl of Benzonase and incubate for 30 min at 37°C, 600 rpm. 6. Centrifuge at 12000 rpm for 2 min, discard the supernatant, add 500 µl of Buffer GB2, vortex and wash the precipitate. Repeat the procedure once.7. Centrifuge at 12000 rpm for 2 min, discard the supernatant, and finally aspirate the residual Buffer GB2 with a small-volume tip. 8. Add 180 µl Lysozyme (10 mg/ml), resuspend the bacterial precipitate and transfer the bacterial resuspension to a Lysis Tube.9. The Lysis Tube is incubated at 37°C, 600 rpm for 20-30 min, then vortexed for 10 min or processed on a thermostatic homogenizer for 10 min at maximum vibration speed (2500-2900 rpm).10. Centrifuge briefly, add 20 µl proteinase K, vortex to mix, add 200 µl buffer GL, vortex to mix, and incubate for 30 min at 56°C, 600 rpm. Note: 1) Do not add Proteinase K directly to Buffer GL.2)For RNA removal, add 4 µl DNase-Free RNase A (100 mg/ml) before adding Buffer GL, shake to mix, and let stand at room temperature for 5-10 minutes.11. Centrifuge at 12000 rpm for 1 min and carefully aspirate the supernatant into a new centrifuge tube. Note: Do not aspirate the glass beads.12. Add 200 µl of anhydrous ethanol, vortex to mix, and centrifuge momentarily to collect the solution to the bottom of the tube. Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.13. Add all of the solution from step 12, including the precipitate, to the Spin Columns DM in the collection tube, or transfer the solution several times if it cannot be added all at once. centrifuge at 12,000 rpm for 1 minute, pour off the waste from the collection tube, and return the column to the collection tube.14. Add 500 µl Buffer GW1 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 min, pour off the waste liquid from the collection tube, and put the adsorbent column back into the collection tube.15. Add 500 µl Buffer GW2 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube. Note: Step 15 can be repeated once if further improvement of DNA purity is required.16. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the column at room temperature for a few minutes and dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorbent column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).17. Place the adsorbent column in a new centrifuge tube (supplied), add 50 µl of Buffer GE to the center of the adsorbent column overhang, let stand at room temperature for 5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20 °C. Attention:1)If the downstream experiments are sensitive to pH or EDTA, sterilized water can be used for elution. The pH value of the eluent has a great influence on the elution efficiency. If the eluent is made of water, the pH value should be 7.0-8.5 (the pH value of water can be adjusted to this range with NaOH), and the elution efficiency is not high when the pH value is lower than 7.0.2)Incubation at room temperature for 5 minutes prior to centrifugation increases yield.3)If the final concentration of DNA is to be increased, the DNA eluate obtained in step 17 can be re-spiked onto the adsorbent membrane and step 17 repeated. 4)DNA stored in water will be affected by acidic hydrolysis. For long-term storage, it is recommended to elute with Buffer GE and store at -20℃... Read More | This reagent kit is based on TRIzon's improved columnar total RNA extraction kit. This product can be extracted from animal groupsExtract total RNA from samples such as textiles, plant materials, various microorganisms, and cultured cells. Firstly, the cracking solution is fully cracked This reagent kit is based on TRIzon's improved columnar total RNA extraction kit. This product can be extracted from animal groupsExtract total RNA from samples such as textiles, plant materials, various microorganisms, and cultured cells. Firstly, the cracking solution is fully cracked andHomogenized samples, in their unique high salt state, RNA specifically binds to silicon matrix membranes, greatly reducingEffectively removing organic solvent contamination while removing protein contamination, resulting in higher purity and quality of RNA. bookThe product can quickly extract total RNA from various cells or tissues, and can process 30-50 mg of tissue or 5 × 10 ⁶ cells each time,Can handle multiple different samples simultaneously. If it is an RNA experiment that is very sensitive to trace amounts of DNA, the residual DNA can be utilizedUsing DNase without RNase for digestion and removal on the column, the extracted RNA can be directly applied to RT-PCR Experiments such as Northern Blot, Dot Blot, and in vitro translation. U665516 Component 50 T Storage U665516A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. U665516B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. U665516C TRIzon Reagent 60 mL 2-8℃. Protect from light. U665516D TRIzon PaI™ 10 mL 2-8℃. Protect from light. U665516E Buffer RW1 40 mL RT U665516F Buffer RW2 (concentrate) 11 mL RT U665516G RNase-Free Water 10 mL RT U665516H Spin Columns RM with Collection Tubes 50 sets RT U665516I RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RTPreparation and important precautions before the experiment:1.To prevent RNase pollution, attention should be paid to the following aspects:1) RNase's plastic products and gun heads to avoid cross contamination.2) Prepare the solution using water without RNase.3) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The sample should avoid repeated freezing and thawing, otherwise it will affect the yield and quality of RNA extraction.3. If TRIzon Reagent is found to have precipitates before use, it can be dissolved in a water bath at 56 ℃ for a few minutes.Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Usage:1. Sample processing1a. Organization: 30-50 mg of tissue is thoroughly ground in liquid nitrogen and 1 mL of TRIzon Reagent is added, or 1 mL of TRIzon Reagent is added to the tissue sample and homogenized. Attention: The sample volume should not exceed 10% of the volume of TRIzon Reagent.2a. Single layer cell culture: Remove the culture medium and add an appropriate amount every 10 cm ² Add 1 mL of TRIzon Reagent.3a. Cell suspension: Collect cells by centrifugation. Add 1 mL of TRIzon Reagent to every 5 × 10 µ m cell.2. After adding TRIzon Reagent, repeatedly blow a few times to fully crack the sample. Leave at room temperature for 5 minutes to completely separate the protein nucleic acid complex.3. Add 200 to every 1 mL of TRIzon Reagent µ LTRIzon PaI ™, Cover the tube tightly, vigorously shake for 15 seconds, and let it sit at room temperature for 2 minutes.4. Centrifuge at 4 ℃ 12000 rpm (~13400 × g) for 10 minutes. At this time, the sample is divided into three layers: the red organic phase, the middle layer, and the upper colorless aqueous phase. RNA is mainly in the upper aqueous phase. Move the upper aqueous phase to a new RNase Free centrifuge tube (provided).5. Add an equal volume of 70% ethanol (prepared without RNase water) to the obtained aqueous solution, invert and mix well.6. Add all the solutions obtained in the previous step to the spin columns RM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred in multiple batches. Centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.8. Preparation of DNase I mixture: Take 52 µ LRNase Free Water, add 8 to it µ L 10 x Reaction Buffer and 20 µ L DNase I (1 U/ µ L) Mix well and prepare to a final volume of 80 µ The reaction solution of L.9. Directly add 80 µ L DNase I mixture to the adsorption column and incubate at 20-30 ℃ for 15 minutes.10. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 1 minute, discard the waste liquid, and place the adsorption column back into the recovery manifold.11. Add 500 to the adsorption column µ L Buffer RW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.12. Repeat step 11.Centrifuge at 12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes and thoroughly air dry. Attention: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (enzyme digestion,. )PCR, etc.14. Place the adsorption column in a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ L. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 14 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 14... Read More | Product content: U665923Component50 T200 TStorageU665923ABuffer GTL15 mL60 mLRTU665923BBuffer GL15 mL50 mLRTU665923CBuffer GW1 (concentrate)13 mL52 mLRTU665923DBuffer GW2 (concentrate)15 mL70 mLRTU665923EBuffer GE15 mL60 mLRTU665923FProteinase K1.25 mL4×1.25 mLRTU665923GSpin Columns DM with Product content: U665923Component50 T200 TStorageU665923ABuffer GTL15 mL60 mLRTU665923BBuffer GL15 mL50 mLRTU665923CBuffer GW1 (concentrate)13 mL52 mLRTU665923DBuffer GW2 (concentrate)15 mL70 mLRTU665923EBuffer GE15 mL60 mLRTU665923FProteinase K1.25 mL4×1.25 mLRTU665923GSpin Columns DM with Collection Tubes50 EA200 EART Product Introduction:This reagent kit is suitable for extracting high-purity total DNA from various samples such as fresh or frozen animal tissues, cells, blood, bacteria, etc. This product can purify DNA fragments with a maximum molecular weight of 50 kb. The purification process does not require the use of toxic solvents such as phenol or chloroform, nor does it require ethanol precipitation. This reagent kit adopts an optimized buffer system to efficiently and specifically bind DNA from the lysis solution to the silica matrix centrifuge adsorption column. Inhibitors of PCR and other enzymatic reactions can be effectively removed through a two-step washing step. Finally, high-purity DNA can be obtained by washing with low salt buffer or water. The purified DNA can be directly used for downstream experiments such as enzyme digestion, PCR, Real Time PCR, library construction, Southern Blot, and molecular labeling.Self prepared reagent: anhydrous ethanolEnzymatic Lysis Buffer (preparation required for extracting genomic DNA from Gram positive bacteria).Self prepared reagent: Enzymatic Lysis Buffer Formula: 20 mM Tris, pH 8.0; 2 mM Na2 EDTA; 1.2% Triton self prepared reagent: X-100; Lysozyme with a final concentration of 20 mg/mL.Preparation and important precautions before the experiment:1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.If extracting the genome of bacterial cultures with a large accumulation of secondary metabolites or thick cell walls, it is recommended to collect samples early in the logarithmic growth phase.3.Before the first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer GTL and Buffer GL. If there is any crystallization or precipitation, please dissolve Buffer GL and Buffer GTL again in a 56 ℃ water bath.5. If downstream experiments are sensitive to RNA contamination, 4 can be added before adding Buffer GL µ RNase A of L DNase Free (100 mg/mL) was not provided in this kit.Operation steps:Genome extraction from blood and cell samples1. Material processing1a If the extracted material is mammalian anticoagulant blood (non nucleated red blood cells), it can be directly directed to 50-200 µ Add Buffer GTL to fresh or frozen anticoagulant blood samples to supplement up to 200 µ L;1b If the extracted material is anticoagulant blood from poultry, birds, amphibians, or lower level organisms, and their red blood cells are nucleated cells, take 5-10 µ L fresh or frozen anticoagulant blood samples, add Buffer GTL to supplement up to 200 µ L;1c The cells cultured on the wall should be first processed into a cell suspension (with a maximum extraction amount of 5 × 10 cells), centrifuged at 2000 rpm (400 × g) for 5 minutes, discarded from the supernatant, and added with 200 µ L GTL, oscillate until the sample is completely suspended;Note: To remove RNA, add 4 after completing the above steps µ RNase A solution with a concentration of 100 mg/mL was vortexed for 15 seconds and left at room temperature for 2 minutes.2. Add 20 µ L Protein K.3. Add 200 µ L Buffer GL, vortex oscillation thoroughly mixed, 56 ℃ water bath for 10 minutes.4. Temporarily centrifuge to remove water droplets from the inner wall of the tube cover. Join 200 µ L anhydrous ethanol, vortex and shake thoroughly to mix well. Short centrifugation.Attention: 1) After adding Bu ff er GL and anhydrous ethanol, immediately vortex shake and mix well.2) The addition of Bu ff er GL and anhydrous ethanol may produce white precipitates, which will not affect subsequent experiments. Some organizations may form sol-gel products after adding Bu ff er GL and anhydrous ethanol, and it is recommended to perform severe shaking or vortex treatment at this time.5. Add all the solutions obtained in the previous step to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.6. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Note: To further improve DNA purity, repeat step 7.8.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).9. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Attention:1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high.2) Preheating the GE in a water bath at 65-70 ℃ and incubating it at room temperature for 5 minutes before centrifugation can increase yield; Use an additional 50-200 µ Re washing with GE or sterilized water can increase yield.3) If the final concentration of DNA needs to be increased, the obtained solution can be re added to the adsorption column, left at room temperature for 2-5 minutes, and centrifuged at 12000 rpm for 1 minute; If the elution volume is less than 200 µ L. It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with GE or sterilized water.4) Because DNA stored in water is affected by acidic hydrolysis, if long-term preservation is required, it is recommended to elute with Bu ff er GE and store at -20 ℃.Genome extraction from animal tissues1. Material processingIf the extracted material is animal tissue, take 25 mg (the amount of spleen tissue should be less than 10 mg); If the material is mouse tail, take a section of rat tail with a length of 0.4-0.6 cm or two sections of mouse tail with a length of 0.4-0.6 cm.1a. After liquid nitrogen grinding or cutting the sample into small pieces, place it in a 1.5 mL centrifuge tube and add 180 mL µ Label different samples with L Buffer GTL.1b If using a homogenizer to process the sample, add no more than 80% of the homogenizer to the sample before homogenization µ L Buffer GTL, add 100 after homogenization µ L Buffer GTL.Attention:1) Ensure that the quantity of each organization does not exceed the recommended range.2) The tissue samples can be ground with liquid nitrogen or homogenized with a homogenizer before adding Bu ff er GTL, which can increase the cracking efficiency.2. Add 20 µ L Protein K, vortex oscillation thoroughly mixes the sample. Take a 56 ℃ water bath until the tissue is completely lysed. During the incubation process, the centrifuge tube can be inverted or shaken periodically to disperse the sample.Attention:1) The digestion time varies for different tissues, usually taking 1-3 hours to complete. The tail of the mouse needs to be digested for 6-8 hours, and if necessary, overnight digestion will not affect subsequent operations.2) If there is still gel like substance after incubation and vortex oscillation, extend the incubation time at 56 ℃ or add another 20 µ L Protein K digestion.3) To remove RNA, add 4 after completing the above steps µ RNase A solution with a concentration of 100 mg/mL, vortex for 15 seconds, and leave at room temperature for 5-10 minutes.3. Add 200 µ L Buffer GL, vortex shake thoroughly and mix well, take a water bath at 70 ℃ for 10 minutes. Add 200 after brief centrifugation µ L anhydrous ethanol, vortex and shake thoroughly to mix well.Attention:1) After adding Bu ff er GL and anhydrous ethanol, immediately vortex and shake to mix well.2) The addition of Bu ff er GL and anhydrous ethanol may produce white precipitates, which will not affect subsequent experiments. Some tissues (such as the spleen and lungs) may form sol-gel products after adding Bu ff er GL and anhydrous ethanol. In this case, it is recommended to perform vigorous shaking or vortex treatment.4. Centrifuge briefly and add all the solution obtained in step 3 to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.5. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.6. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Note: To further improve DNA purity, repeat step 6.7.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).8. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Attention:1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high.2) Preheating the GE in a water bath at 65-70 ℃ and incubating it at room temperature for 5 minutes before centrifugation can increase yield; Use an additional 50-200 µ Re washing with GE or sterilized water can increase yield.3) If the final concentration of DNA needs to be increased, the obtained solution can be re added to the adsorption column, left at room temperature for 2-5 minutes, and centrifuged at 12000 rpm for 1 minute; If the elution volume is less than 200 µ L. It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with GE or sterilized water.4) Because DNA stored in water is affected by acidic hydrolysis, if long-term preservation is required, it is recommended to elute with Bu ff er GE and store at -20 ℃. i ii Genomic extraction of blood and cell samples1. Bacterial sample pretreatment1a Gram negative bacteria(1) Take 1-5mL of bacterial culture (10 ^ -10 ^ cells, up to a maximum of 2 × 10 ^ cells) and place it in a centrifuge tube (self prepared). Centrifuge at 12000 rpm (~13400 × g) for 1 minute and try to aspirate the supernatant as much as possible.(2) Add 180 to the precipitate µ L Buffer GTL, shake to suspend bacterial weight.(3) Join 20 µ L Protein K, vortex mix well, incubate at 56 ° C until the bacterial cell is completely lysed, and during the incubation process, invert or shake the centrifuge tube periodically to disperse the sample.Note: To remove RNA, add 4 after completing the above steps µ L RNase A solution with a concentration of 100 mg/mL, shake well and let stand at room temperature for 5-10 minutes.(4) Join 200 µ L Buffer GL, vortex oscillation mixing.1b Gram positive bacteria(1) Take 1-5 mL of bacterial culture (10 ^ -10 ^ cells, maximum not exceeding 2 x 10 ^ cells) and place it in a centrifuge tube (self prepared). Centrifuge at 12000 rpm for 1 minute and try to aspirate the supernatant as much as possible.(2) Join 180 µ L Enzymatic Lysis Buffer (self provided) suspends the bacterial weight.(3) Incubate at 37 ℃ for 30 minutes.(4) Join 20 µ L Protein K vortex oscillation, thoroughly mixed. Join 200 µ L Buffer GL, vortex oscillation mixing. Incubate at 56 ℃ for 30 minutes.Attention:1) If necessary, incubation at 95 ° C for 15 minutes can inactivate the pathogen, but incubation at 95 ° C can cause some DNA degradation.2) To remove RNA, add 4 after completing the above steps µ L RNase A solution with a concentration of 100 mg/mL, shake well and let stand at room temperature for 5-10 minutes.2. Add 200 µ L anhydrous ethanol, vortex and shake thoroughly to mix well.Attention: Adding anhydrous ethanol may produce white precipitates, which will not affect subsequent experiments.3. Add all the solution obtained from step 2 (including the formed precipitate) to the adsorption column (Spin Columns DM) that has been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.4. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.5. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Note: To further improve DNA purity, repeat step 5.6.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).7. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Attention:1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high.2) Preheating the GE in a water bath at 65-70 ℃ and incubating it at room temperature for 5 minutes before centrifugation can increase yield; Use an additional 50-200 µ Re washing with GE or sterilized water can increase yield.3) If the final concentration of DNA needs to be increased, the obtained solution can be re added to the adsorption column, left at room temperature for 2-5 minutes, and centrifuged at 12000 rpm for 1 minute; If the elution volume is less than 200 µ L. It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with GE or sterilized water.4) Because DNA stored in water is affected by acidic hydrolysis, if long-term preservation is required, it is recommended to elute with Bu ff er GE and store at -20 ℃... Read More |