| Description | Cell proliferation assays are widely used in the evaluation of cell viability, genotoxicity, and the efficacy of antitumor drugs. Direct detection of DNA synthesis in cells is considered the most accurate method for assessing cell proliferation. EdU (5-ethynyl-2′-deoxyuridine) is a Cell proliferation assays are widely used in the evaluation of cell viability, genotoxicity, and the efficacy of antitumor drugs. Direct detection of DNA synthesis in cells is considered the most accurate method for assessing cell proliferation. EdU (5-ethynyl-2′-deoxyuridine) is a novel thymidine (thymine deoxyribonucleoside) analogue. During DNA synthesis, EdU can be incorporated into newly synthesized DNA in place of thymidine. The ethynyl group on EdU can undergo a covalent reaction with fluorescently labeled small-molecule azide probes (such as Azide Alexa Fluor 488, Azide Alexa Fluor 555, Azide Alexa Fluor 594, Azide Alexa Fluor 647, etc.) via Cu(I)-catalyzed click chemistry, forming a stable triazole ring. This reaction is highly efficient and is referred to as the Click reaction. Through this process, newly synthesized DNA is labeled with the corresponding fluorescent probes, enabling the detection of proliferating cells using appropriate fluorescence detection equipment.Product Component TableE1456506Component50 T100 T200 TStorage conditionsQuantity Per TestE1456506AEdU(10 mM)100µL200µL400µL-20℃.Store in the dark.2 µL per 1.0-2.0 × 10⁶ cellsE1456506B6-FAM125µL250µL500µL-20℃.Store in the dark.2.5 µL per 1.0-2.0 × 10⁶ cellsE1456506CClick Reaction Buffer13 mL26 mL52 mL-20℃.Store in the dark.237.5 µL per 1.0-2.0 × 10⁶ cellsE1456506DCuSO40.5 mL1 mL2 mL-20℃.10 µL per 1.0-2.0 × 10⁶ cellsE1456506EClick Additive248 mg496 mg992 mg-20℃.Store in the dark.250 µL per 1.0-2.0 × 10⁶ cellsE1456506FDAPI Staining Solution(1000×)25 µL50 µL100µL-20℃.Store in the dark.0.5 µL per 1.0-2.0 × 10⁶ cells Usage Protocol1. Preparation1) Preparation of Click Additive Solution: For a 50-test kit: Add 12.5 mL of pre-chilled deionized water to the tube. Mix thoroughly until completely dissolved to obtain the Click Additive Solution. For a 100-test kit: Add 25 mL of pre-chilled deionized water to the tube. Mix thoroughly until completely dissolved to obtain the Click Additive Solution. For a 200-test kit: Add 50 mL of pre-chilled deionized water to the tube. Mix thoroughly until completely dissolved to obtain the Click Additive Solution. After preparation, aliquot the solution as needed and store at -20°C. If a white precipitate forms after dissolution, invert the tube repeatedly until it is fully dissolved before use. If the solution turns brown, it indicates degradation of the active component; discard it.2) Upon initial dissolution of the Click Reaction Buffer, aliquot it according to the number of samples per experiment and store at -20°C.2. EdU Labeling of CellsIt is recommended to use a final EdU concentration of 10 µM (1×). A 1:500 dilution of EdU (10 mM) in cell culture medium yields a 2× EdU working solution (20 µM). Mix an equal volume of pre-warmed (37°C) 2× EdU working solution (20 µM) with the cell suspension to achieve a final 1× EdU concentration. Incubate in a 37°C, 5% CO₂ incubator. Factors such as cell culture medium, cell density, cell type, and other experimental conditions may affect labeling efficiency. Therefore, the optimal EdU concentration and labeling duration must be empirically determined based on the cell type under investigation.3. Fixation and Permeabilization1) Harvest cells and centrifuge at 300 ×g for 5 min. Wash cells twice with PBS containing 2% FBS.2) Fix cells with 4% paraformaldehyde solution. Mix thoroughly and incubate for 15 min at room temperature protected from light.3) Collect cells and centrifuge at 300 × g for 5 min. Wash cells twice.4) Resuspend cells in PBS containing 0.1% Triton X-100. Mix well and incubate for 15 min at room temperature.5) Centrifuge at 300 × g for 5 min and wash cells twice.4. Fluorescent Labeling1) This protocol is based on a 500 µL reaction system per 2 × 10⁶ cells. The volume of the Click reaction mixture can be adjusted according to the experimental sample size.2) Centrifuge the cells at 300 ×g for 5 minutes. Add 500 µL of Click reaction mixture per sample, mix gently, and incubate for 30 minutes at room temperature protected from light.3) After the reaction, wash the cells twice with PBS containing 2% FBS.4) Dilute the DAPI Staining Solution (1000×) to 1× using PBS containing 2% FBS. Add 250 µL of the diluted DAPI solution to each sample and incubate for 5 minutes at room temperature.5) Add an additional 250 µL of PBS containing 2% FBS, mix gently, and proceed to detection using an appropriate flow cytometry instrument.Precautions1. Strictly adhere to the component order and volumes specified in the table above when preparing the Click reaction mixture, as deviations may affect subsequent experimental results.2. The Click reaction mixture must be used within 15 minutes of preparation.3. To avoid fluorescence quenching, perform detection as soon as possible after sample preparation... Read More | DescriptionRefer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Products contentN665993Component240 TStorageN665993AIndex N501 Primers for Illumina240 µL-20℃. Avoid freeze/ Thaw cycle.N665993BIndex N925-N948 Primers for Illumina24×10 µL-20℃. Avoid freeze/ Thaw cycle. Products Introduction This kit is a companion kit to the transposase-Products contentN665993Component240 TStorageN665993AIndex N501 Primers for Illumina240 µL-20℃. Avoid freeze/ Thaw cycle.N665993BIndex N925-N948 Primers for Illumina24×10 µL-20℃. Avoid freeze/ Thaw cycle. Products Introduction This kit is a companion kit to the transposase-based Rapid DNA Library Construction Kit for Illumina platform library construction. Each kit contains one N5 primer and 24 N7 primers, which can be used to prepare 24 different single-ended Index libraries. All reagents provided in the kits have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The libraries can be used for sequencing on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Kangwei Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes;Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers. ProcedureFor the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol.Index N501 Primer for IlluminaIndex N901-N996 Primer for Illumina... Read More | Product contentS666146Component50 T200 TStorageS666146ABuffer GR25 mL120 mLRTS666146BBuffer GL25 mL120 mLRTS666146CBuffer GW1 (concentrate)13 mL52 mLRTS666146DBuffer GW2 (concentrate)15 mL75 mLRTS666146EBuffer GE15 mL60 mLRTS666146FProteinase K1.25 mL4×1.25 mLRTS666146GSpin Columns DS with Product contentS666146Component50 T200 TStorageS666146ABuffer GR25 mL120 mLRTS666146BBuffer GL25 mL120 mLRTS666146CBuffer GW1 (concentrate)13 mL52 mLRTS666146DBuffer GW2 (concentrate)15 mL75 mLRTS666146EBuffer GE15 mL60 mLRTS666146FProteinase K1.25 mL4×1.25 mLRTS666146GSpin Columns DS with Collection Tubes50 sets 200 setsRTS666146HCentrifuge Tubes (1.5 mL)50 EA200 EARTProductsThis kit provides a simple and rapid method for the isolation and purification of total DNA from buccal swab samples. The kit adopts a silica matrix membrane that can specifically bind DNA and a unique buffer system to adsorb DNA efficiently and specifically, and 0.5-3.5 µg of genomic DNA can be obtained from each swab, and the extracted DNA fragments are large, pure and of stable and reliable quality. It is suitable for enzyme digestion, PCR, library construction, Southern hybridization and other experiments.Self-contained reagent: anhydrous ethanol.Pre-experiment Preparation and Important Notes1. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.2. If precipitation is found in Buffer GL before use, dissolve Buffer GL in a 56°C water bath.3. All centrifugation steps can be performed at room temperature.4. Sampling: Use a buccal swab to wipe the inside of the mouth 6 times, dry for 2 hours and store. To ensure that the sample is not contaminated by food or drink, do not eat or drink for 30 minutes before sampling.Procedure1. The swab of the buccal swab was cut from the rod with scissors and placed in a 2mL centrifuge tube (supplied) and 400µL Buffer GR was added.Note: For genomic DNA without RNA contamination, add 4 µL of RNase A solution at a concentration of 100 mg/ml and shake to mix.2. Add 20 µL of Proteinase K and 400 µL of Buffer GL, immediately vortex and shake for 15 seconds and mix thoroughly.Note: Mix well immediately after adding Buffer GL; do not add Proteinase K directly to Buffer GL for use.3.56°C for 10 minutes and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.4. Add 400 µL of anhydrous ethanol, vortex and shake to mix thoroughly, and centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube.Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.5. Add the solution and precipitate obtained in the previous step to the Spin Columns DS in two batches of up to 700 µL at a time into the collection tube. centrifuge the column at 12,000 rpm (∼13,400 × g) for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.6. Add 500 µL of Buffer GW1 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.7. Add 500 µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge the column at 12,000 rpm for 3 minutes, pour off the waste liquid in the collection tube, and put the column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 1 minute and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new 1.5 mL centrifuge tube, add 50 µL of Buffer GE or sterilized water to the middle of the adsorption column overhanging the column, let stand at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store at -20℃.Attention:(1) If the downstream experiment is sensitive to pH or EDTA, it can be eluted with sterilized water. The pH value of the eluent has a great influence on the elution efficiency. If the eluent is made of water, the pH value should be 7.0-8.5 (the pH value of water can be adjusted to this range by using NaOH), and the elution efficiency is not high when the pH value is lower than 7.0.2) For long-term storage, it is recommended to elute with Buffer GE and store at -20°C... Read More |