| Description | Inquire | Format:2-ComponentEnzyme:Horseradish peroxidase | H665581 Component 100 T Storage H665581A gDNA Eraser 50 µL -20℃. Avoid freeze/thaw cycle. H665581B 10×gDNA Eraser Buffer 120 µL -20℃. Avoid freeze/thaw cycle. H665581C HiFiScript, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. H665581D 5×ScriptRT H665581 Component 100 T Storage H665581A gDNA Eraser 50 µL -20℃. Avoid freeze/thaw cycle. H665581B 10×gDNA Eraser Buffer 120 µL -20℃. Avoid freeze/thaw cycle. H665581C HiFiScript, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. H665581D 5×ScriptRT Buffer 500 µL -20℃. Avoid freeze/thaw cycle. H665581E Primer Mix 120 µL -20℃. Avoid freeze/thaw cycle. H665581F RNase-Free Water 2×1 mL -20℃. Avoid freeze/thaw cycle.Product IntroductionThis product is a kit for removing genomic DNA for reverse transcription. The kit removes genomic DNA in 2 minutes at 42°C. Since the reverse transcription reagent contains a component that inhibits gDNA Eraser, cDNA can be synthesized directly by reverse transcription of gDNA Eraser-treated samples.The kit is equipped with a new high-efficiency reverse transcription enzyme, HiFiScript, with novel mutation sites that dramatically increase the transcriptional activity of the enzyme, resulting in higher efficiency and yield of cDNA first-strand synthesis. The first strand of cDNA can be synthesized with higher efficiency and yield, and the first strand of cDNA can be synthesized from pg total RNA or mRNA. If the reverse transcription product cDNA is used for downstream fluorescence quantitative detection, the reverse transcription reaction can be completed at 42℃ in 15 minutes. This kit is suitable for the synthesis of first-strand cDNA and subsequent RT-PCR, RT-qPCR, and the construction of full-length cDNA libraries.Product Features1. Rapid genome removal: contains gDNA Eraser for genomic DNA removal, which removes genomic DNA in just 2 minutes.2. Rapid reverse transcription: 15 minutes to obtain fluorescent quantitative PCR template cDNA first strand synthesis.3. High sensitivity: cDNA first strand can be synthesized using pg-level total RNA or mRNA templates.4. Highly efficient reverse transcription: Novel mutation sites dramatically increase enzyme activity, resulting in higher yields of cDNA.matters needing attention1. During operation, RNase contamination should be avoided to prevent RNA degradation or cross-contamination in the experiment. It is recommended that operators wear masks and disposable gloves and change the gloves frequently, and use specialized instruments and consumables.2. The reverse transcription system is prepared and operated on ice to prevent degradation of RNA. Store the kit enzymes at -20ºC as soon as possible after use and try to avoid repeated freezing and thawing.3. The reaction system can be scaled up to a maximum of 1 µg of total RNA in 10 µl of reaction system.4. Primer Mix is prepared by Oligo(dT) and Random primer, and Oligo-dT Primer or Gene Specific Primer can also be used according to the experimental needs.5. If the amount of starting RNA is less than 50ng, it is recommended to add RNAase inhibitor (RNasin).6. For RNA templates with complex secondary structures, it is recommended to incubate the template RNA at 65°C for 5 minutes immediately on ice prior to the manipulation step and centrifuge briefly before proceeding to the next step.UsageThaw template RNA on ice; place kit components on ice immediately after thawing at room temperature. Each solution was mixed by vortexing and shaking before use and briefly centrifuged.I. Genomic DNA removal reactions1. Prepare the reaction system according to the following table on ice in a total volume of 10 µl. To ensure the accuracy of the reaction solution preparation, prepare the premixed system in the amount of reaction number + 2 before dispensing it into each reaction tube and finally adding the RNA sample.Note: 1) If the amount of total RNA is greater than 1µg, scale up the reaction system proportionally. If the amount of starting RNA is less than 50ng, it is recommended to add RNAase inhibitor (RNasin).2. Mix by vortex shaking and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.3. Incubate at 42°C for 2 minutes (this can be extended to 30 minutes for room temperature reactions).4.At the end of the reaction, centrifuge briefly and place on ice to cool.II. Reverse transcription reaction1. Prepare the reaction system on ice according to the following table. In order to ensure the accuracy of the reaction solution configuration, first prepare a premixed solution in the amount of number + 2, and then dispense 10 µl into each reaction tube, take 10 µl of the prepared premixed solution and add it to the reaction tube of step 1 where the de-etching of the genome has been completed.Note: 1) Oligo-dT Primer or Gene Specific Primer can be used according to the needs of the experiment, it is recommended to use 50 pmol of Oligo-dT Primer or 2 pmol of Gene Specific Primer for 20 µl reaction system.2. Mix well and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.3. cDNA synthesis reaction conditions:1) If fluorescent quantitative PCR assay is performed downstream, incubate at 42°C for 15 minutes and 85°C for 5 minutes.2) If downstream for normal PCR assay, incubate at 42°C for 30-50 minutes and 85°C for 5 minutes. Note: For templates with complex secondary structure or high GC content, the reverse transcription temperature can be increased to 50°C to enhance reverse transcription efficiency.4. At the end of the reaction, centrifuge briefly and place on ice before proceeding with subsequent PCR or fluorescence quantitative PCR, or place at -20°C if prolonged storage is required.Note: When performing Real-time PCR reactions, the amount of reverse transcription product added should not exceed 1/10 of the total volume of the PCR reaction... Read More | This kit combines efficient guanidine isothiocyanate lysis technology with silicon matrix membrane purification technology to efficiently extract total RNA from animal cells and tissues. The starting sample usually has a maximum of 30 mg of tissue or 1 x 107 cells. This reagent kit can also recover This kit combines efficient guanidine isothiocyanate lysis technology with silicon matrix membrane purification technology to efficiently extract total RNA from animal cells and tissues. The starting sample usually has a maximum of 30 mg of tissue or 1 x 107 cells. This reagent kit can also recover partially purified RNA, RNA obtained from in vitro transcription and enzymatic reactions. This reagent kit can extract and purify high-quality RNA with a molecular weight greater than 200 bases, with almost no DNA residue. If RNA experiments are to be conducted that are highly sensitive to trace amounts of DNA, residual DNA can be digested and removed on a column using DNase I without RNase. The extracted RNA can be used for downstream experiments such as RT-PCR, Northern Blot, Dot Blot, etc. R666020Component50 TStorageR666020ABuffer RL35 mLRTR666020BBuffer RW140 mLRTR666020CBuffer RW2 (concentrate)11 mLRTR666020DRNase-Free Water10 mLRTR666020ESpin Columns RM with Collection Tubes50 setsRTR666020FRNase-Free Centrifuge Tubes (1.5 mL)50 EART Self prepared reagents: β- Mercaptoethanol, anhydrous ethanol (newly opened or dedicated for RNA extraction).Preparation and important precautions before the experimentTo prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The extracted samples should avoid repeated freeze-thaw cycles, otherwise it will affect the quantity and quality of RNA extraction.3. Before use, please check if there is any crystallization or precipitation in the Buffer RL. It can be heated at 56 ℃ and re solved. Please add Buffer RL before use β- Mercaptoethanol, with a final concentration of 1%. Add 10 to 1ml Buffer RL µ L β- Mercaptoethanol. join β- The buffer RL room temperature of mercaptoethanol can be stored for one month.4. Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.6. If downstream experiments are highly sensitive to DNA, it is recommended to treat RNA with DNase I that does not contain RNase.Operation steps1. Sample processing1a organization: Grind the organization in liquid nitrogen. Add 600 to every 20-30 mg of tissue µ L Buffer RL (check if it is added before use) β- Mercaptoethanol), tissue sample less than 20 mg plus 350 µ Buffer RL. The sample volume shall not exceed one tenth of the buffer RL volume.1b Single layer culture of cells: The cells are directly lysed or processed into cell suspensions in a culture bottle, centrifuged to obtain cell precipitates, and the supernatant is discarded. 600 is added every 6-10 cm2 of culture area µ Buffer RL, less than 6 cm2, add 350 µ Blow buffer RL several times to fully crack it.1c cell suspension: Centrifuge at 12000 rpm (~13400 × g) for 1 minute to discard the supernatant and obtain cell precipitate. Add 600 cells every 5 × 106-1 × 107 cells µ Buffer RL, less than 5 × 106 cells added to 350 µ Blow buffer RL several times to fully crack it.Attention:1) Try to eliminate the cell culture medium as much as possible, as it may inhibit cell lysis and affect RNA production.2) Try to fully suspend and lyse the cells, otherwise it will affect RNA production.2. After the sample is fully lysed, it should be left at room temperature for 5 minutes to completely separate the protein nucleic acid complex.3. Centrifuge at 2000rpm for 2-5 minutes, take the supernatant and proceed to the next step.4. Add 1 volume (600) µ L or 350 µ l) Mix 70% ethanol (prepared without RNase water) well.Attention: Adding ethanol may cause precipitation and will not affect subsequent experiments.5. Add all the solution obtained in step 4 to the Spin Columns RM that has been loaded into the collection tube. If it is not possible to add all the solution to the adsorption column at once, please transfer it in two batches, centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube. Attention: The maximum loading capacity of the adsorption column is 100 µ g, do not overload, otherwise it will affect the yield and purity of RNA.6. Add 700 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column in the collection tube.Optional steps: If conducting RNA experiments that are highly sensitive to trace amounts of DNA, replace step 6 with the following steps.1) Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 15 seconds, discard the waste liquid, and place the adsorption column back into the recovery manifold.2) Preparation of DNase I mixture: Take 52 µ Add 8 RNase Free Water to it µ 10 x Reaction Buffer and 20 µ DNase I (1 U/ µ l) Mix well and prepare to a final volume of 80 µ The reaction solution of L.Attention: The above system is configured according to our company's DNase I reaction system. Please refer to the corresponding manual for other company products.3) Add 80 µ l of the prepared DNase I reaction solution directly to the adsorption column and incubate at 20-30 ℃ for 15 minutes.4) Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 15 seconds, discard the waste liquid, and place the adsorption column back into the recovery manifold.7. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.8. Repeat step 7. 9. Centrifuge at 12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).10. Place the adsorption column in a new RNase free centrifuge tube, and add 30-50 to the middle of the adsorption column in the air µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 10 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 10... Read More | Product contentComponentY665957-1mlY665957-5ml2×GoldStar Probe Mixture1 ml5×1 mlProbe Primer Mix300 µl5×300 µlHuman DNA Standard(100 ng/µl)100 µl5×100 µl50×High ROX40 µl200 µlProduct IntroductionThis product is a real-time Product contentComponentY665957-1mlY665957-5ml2×GoldStar Probe Mixture1 ml5×1 mlProbe Primer Mix300 µl5×300 µlHuman DNA Standard(100 ng/µl)100 µl5×100 µl50×High ROX40 µl200 µlProduct IntroductionThis product is a real-time fluorescence quantitative PCR kit for detecting the concentration of human male Y chromosome, including carefully optimized PCR reaction solution, primer mixture and standards, especially suitable for the quantitative detection of precious and micro DNA samples. The kit adopts a new efficient and fast hot-start amplification enzyme GoldStar Taq DNA Polymerase, which effectively avoids non-specific amplification caused by non-specific binding of primers and templates or primer dimerization at room temperature. This product realizes accurate quantification of Y chromosome and can be applied in various fields such as genetic mapping, species polymorphism research, disease gene localization, paternity testing and forensic analysis.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.Note: High Rox and Low Rox are formulated as described in Method of Use 3.Scope of applicationThis product is suitable for quantitative testing of male Y chromosome DNA in scientific research, clinical, forensic medicine and paternity testing.Usage1. Amplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.05-10 ng/µL. 4°C on ice was set aside.2. Standard dilution: according to the following table, firstly dilute Human DNA Standard (100ng/uL) with TE to make 5 standards of different concentrations according to the table below. 10ng/µL of DNA Standard 1 (Std.1) can be stored stably at -20℃ for 1 month; Std2-5 can only be used on the same day, and should be placed at 4℃ or on ice when not in use for the time being after preparation. When Std2-5 are not used temporarily after preparation, they should be stored at 4℃ or on ice.Standard sampleCorresponding concentration(ng/µl)Minimum Dilution Volume (Unit:µl)Std.11010 [100 ng/µl DNA Standard]+ 90 TEStd.22.520 [Std. 1] +60 TEStd.30.62520 [Std. 2] +60 TEStd.40.1562520 [Std. 3] +60 TEStd.50.039062520 [Std. 4] +60 TE3. qPCR reaction system preparationBefore preparation, the cryopreserved reagents to be used were completely melted and mixed by inverting several times, then centrifuged briefly and prepared. Standards and templates were diluted as described above and prepared.The base reaction system for 20 µL was as follows:Reagent20 µl Reaction system2×GoldStar Probe Mixture10 µlProbe Primer Mix3 µlTemplate4 µlddH₂O3 µlNote: High ROX model: add 1 µL of 50×High ROX per 50 µL of reaction system; Low ROX model: add 1 µL of 50×High ROX per 500 µL of reaction system.A sufficient amount of reaction system mixture was prepared according to the need, and after the reaction system was prepared and mixed thoroughly, it was added to the reaction wells in a volume of 16 µl per well. Then add the prepared standards and diluted samples into the corresponding reaction wells, the amount of addition is 4µL/well. TE was added to the blank control tube, and the same amount was added at 4 µL/well.It is recommended to use 20 µL for the reaction, if you need to perform a smaller system reaction, reduce the system components in equal proportion.4. qPCR reaction programThe PCR mix of this kit contains a FAM fluorescent probe for the target gene and a VIC fluorescent probe with internal reference to Internal PCR Control (IPC). qPCR program with dual fluorescence of hydrolyzed probes needs to be selected for the assay. Please follow the instructions of the instrument used to set up the qPCR program, and the PCR temperature conditions are as follows:1. Standard curve productionThe standard curve was plotted with reference to the Excel sheet for data processing. The correlation coefficient R2 of the standard curve should be not less than 0.98, and the slope should be located between -3.1 and -3.6 when the Ct value is used as the longitudinal coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard Concentration(ng/µL)DNA Standard 110DNA Standard 22.5DNA Standard 30.625DNA Standard 40.15625DNA Standard 50.03906252. Analysis of results and calculation of concentrationsThe Ct difference between experimental replicate wells for FAM signaling of the target gene should be no more than 0.3, otherwise invalid data need to be deleted or the experiment needs to be repeated, do not use Ct outside the valid Ct range of the standard curve to calculate the concentration of the sample.For specific calculations, please refer to the data processing Excel for this product.If the FAM signal is abnormal, the VIC signal of the internal reference Internal PCR Control (IPC) needs to be analyzed to confirm whether the PCR reaction process is abnormal. If the Ct value of the sample null VIC is significantly larger than that of the standard or blank control wells, it means that the sample inhibits the PCR reaction.matters needing attention1. Before testing, these instructions should be read in detail. It should be operated by personnel with professional experience or qualified by training.2. For use, please mix gently by turning up and down, avoid foaming as much as possible, and use it after centrifugation for a short period of time.3. Avoid repeated freezing and thawing of the product, repeated freezing and thawing may degrade the performance of the product.4. When preparing the reaction solution, please use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More |