| Description | Starch hydrolases include α-amylase (α-AL, EC 3.2.1.1) and β-amylase (β-AL). α-Amylase randomly catalyzes the hydrolysis of α-1,4-glycosidic bonds in starch, producing reducing sugars such as glucose, maltose, maltotriose, and dextrins, while simultaneously Starch hydrolases include α-amylase (α-AL, EC 3.2.1.1) and β-amylase (β-AL). α-Amylase randomly catalyzes the hydrolysis of α-1,4-glycosidic bonds in starch, producing reducing sugars such as glucose, maltose, maltotriose, and dextrins, while simultaneously reducing the viscosity of starch, hence it is also known as the liquefying enzyme. α-Amylase is widely distributed, from microorganisms to higher plants. Detection Principle: Starch hydrolases catalyze the hydrolysis of starch to produce reducing sugars. These reducing sugars reduce 3,5-dinitrosalicylic acid (DNS) to produce a brown-red-colored compound with an absorption peak at 540 nm. The amylase activity is calculated by measuring the rate of increase in absorbance at 540 nm. α-Amylase is heat-stable, but β-amylase can be inactivated by heating at 70°C for 15 minutes. Therefore, after the crude enzyme extract is treated at 70°C for 15 minutes, only α-amylase can catalyze starch hydrolysis. Detection Range: 0.0156 - 1 mg/mL Sensitivity: 0.0078 mg/mL Applicable Samples: Saliva, animal tissues, plant tissues (seeds or newly germinated seedlings) Note: The detection range and sensitivity are based on the standard. The actual detection range and sensitivity for activity need to be calculated according to the sample conditions.G1501772Component96TStorageG1501772ADNS Reagent40 mL2-8℃. Store in the dark.G1501772BSubstrate1EA2-8℃G1501772CStandard1EA2-8℃Note: Before formal testing, it is recommended to perform a preliminary test with 2-3 samples expected to have significant differences.User-Prepared Instruments and Reagents1.Microplate reader or visible spectrophotometer (capable of measuring absorbance at 540 nm)2.96-well plate or micro glass cuvettes, adjustable micropipettes and tips3.Centrifuge, water bath4.Deionized water5.Homogenizer (for tissue samples)Experimental Procedure1. Reagent PreparationReagent NameReagent PreparationNotesDNS ReagentReady-to-use; Equilibrate to room temperature before use.Store at 4°C protected from light.SubstrateBefore use, add 20 mL deionized water, invert and shake several times, heat until dissolved.Unused reagent can be stored at 4°C for one week. If precipitate forms, heat to 70°C to dissolve.StandardBefore use, add 1 mL deionized water to dissolve, obtaining a 10 mg/mL standard (Glucose) stock.Can be stored at 4°C for 2 weeks.2. Standard Curve SetupDilute the 10 mg/mL standard stock solution with deionized water to concentrations of 1, 0.5, 0.25, 0.125, 0.0625, 0.0313, and 0.0156 mg/mL as shown in the table below.TubeStandard VolumeDeionized Water Volume (µL)Standard Concentration (mg/mL)Std.140µL (10 mg/mL)3601Std.2200µL of Std.12000.5Std.3200µL of Std.22000.25Std.4200µL of Std.32000.125Std.5200µL of Std.42000.0625Std.6200µL of Std.52000.0313Std.7200µL of Std.62000.0156Note: The standard curve must be generated with each experiment. Diluted standard solutions are unstable and must be used within 4 hours3. Sample PreparationNote: Fresh samples are recommended.3.1 Animal TissueWeigh approximately 0.1 g of tissue. Add 1 mL of deionized water and homogenize. Transfer the homogenate to a centrifuge tube. Let it stand at room temperature for 15 minutes, vortexing every 5 minutes for sufficient extraction. Centrifuge at 6,000 g for 10 minutes at room temperature. Aspirate the supernatant and dilute to 10 mL with deionized water. Mix well. This is the amylase stock solution.3.2 Plant TissueWeigh approximately 0.1 g of tissue. Add 1 mL of deionized water and grind. Sonicate for 5 minutes (power 20%, pulse 3s on, 7s off, repeat 30 times). Let it stand at room temperature for 15 minutes, vortexing every 5 minutes for sufficient extraction. Centrifuge at 6,000 g for 10 minutes at room temperature. Aspirate the supernatant and dilute to 10 mL with deionized water. Mix well. This is the amylase stock solution.3.3 Saliva, and Other Liquid SamplesAssay directly. It is recommended to perform a preliminary test to determine the appropriate dilution factor.Note:For animal tissues with high fat content, remove the upper fat layer after centrifugation before collecting the supernatant.If protein concentration measurement is required, use Aladdin's BCA Protein Quantification Kit (B665595) or Ready-to-Use BCA Protein Quantification Kit (R1491648).4. Assay Steps4.1 Preheat the microplate reader or visible spectrophotometer for at least 30 minutes. Set the wavelength to 540 nm. For spectrophotometers, zero the instrument with deionized water.4.2 Preheat a water bath to 70°C.4.3 Take 75 µL of sample and incubate in a boiling water bath for 5 minutes. This will be used as the Control tube.4.4 Sample Measurement (Add reagents sequentially into microcentrifuge tubes as below):ReagentBlank Tube (µL)Standard Tube (µL)Test Tube (µL)Control Tube (µL)Deionized Water75000Standard (various conc.)07500Sample007575 (boiled sample)Heat at 70°C for 15 min, then cool.Substrate00750Incubate in a constant temperature water bath at 40°C for 5 min.DNS Reagent150150150150Substrate75750754.5 Mix well. Incubate in a boiling water bath for 5 minutes. Cool. Transfer 200 µL to a 96-well plate or micro glass cuvette. Measure the absorbance at 540 nm. Calculate ΔA test = A test - A control ; ΔA standard = A standard - A blank. Note: Each sample requires a control tube. The blank tube only needs to be prepared once. It is recommended to perform a preliminary test with 2-3 samples expected to have significant differences before the formal experiment. If A test > 2, the enzyme activity is too high, and the sample must be diluted with deionized water to an appropriate concentration (multiply by the dilution factor in the calculation). If ΔA test < 0.005, re-extract the sample reducing the final volume of deionized water used for dilution.5. Calculation of Results 5.1 Standard Curve Plotting Plot the standard concentration (y-axis) against ΔA standard (x-axis) to generate the standard curve. Substitute ΔA test into the standard curve equation to calculate y (mg/mL). 5.2 α-Amylase Activity Calculation (1) Based on Sample Fresh Weight Calculation (1) Based on Sample Fresh Weight Calculation Unit Definition: One unit of enzyme activity is defined as the amount of enzyme that catalyzes the production of 1 mg of reducing sugar per minute per gram of tissue. Calculation Formula: α-Amylase Activity (U/g weight) = y × V sample ÷ (W × V sample ÷ V total ) ÷ T × n = 2 × y ÷ W × n (2) Based on Sample Protein Concentration (2) Based on Sample Protein Concentration Calculation Unit Definition: One unit of enzyme activity is defined as the amount of enzyme that produces 1 mg of reducing sugar per minute per milligram of tissue protein. Calculation Formula: α-Amylase Activity (U/mg prot) = y × V sample ÷ (Cpr × V sample ) ÷ T × n = 0.2 × y ÷ Cpr × n (3) Based on Liquid Sample Volume Calculation Unit Definition: One unit of enzyme activity is defined as the amount of enzyme that produces 1 mg of reducing sugar per minute per liter of liquid sample. Calculation Formula: α-Amylase Activity (U/L) = 1000 × y ÷ T × n = 200 × y × n Parameter Definitions: y: Concentration of reducing sugar calculated from the standard curve (mg/mL) V sample : Volume of sample added to the reaction system (0.075 mL) W: Sample weight (g) V total : Total volume of the sample extract (10 mL) T: Enzymatic reaction time (5 minutes) n: Sample dilution factor Cpr: Sample protein concentration (mg/mL) 1000: Conversion factor between liters and milliliters (1 L = 1000 mL)6. Representative ResultsTypical Standard Curve: y = 0.4948x - 0.0179, R² = 0.9982Precautions1. Biochemical reagents are generally irritating and potentially biologically toxic. For your safety and health, please use appropriate biosafety precautions throughout the experiment, including wearing lab coats, masks, gloves, and head covers. Perform experiments in a fume hood or biosafety cabinet.2. This product is for research use only. Not for use in clinical diagnosis... Read More | Format:2-ComponentEnzyme:Horseradish peroxidase | DescriptionIt contains a set of six different heterogeneous palladium catalysts, useful for rapid screening of catalysis conditions. It is in sampler format with individual components packaged for multiple experiments and mini scale-up. The cost of the kit is less than the total cost of individual DescriptionIt contains a set of six different heterogeneous palladium catalysts, useful for rapid screening of catalysis conditions. It is in sampler format with individual components packaged for multiple experiments and mini scale-up. The cost of the kit is less than the total cost of individual components.Catalysis Screening Kits... Read More | Products contentNote: The amount of individual primers used is 1 µl, each N7-end primer can perform 10 DNA library constructs, and each kit can perform 240 DNA library constructs.Products IntroductionThis kit is a companion kit to the transposase-based Rapid DNA Library Construction Kit for Products contentNote: The amount of individual primers used is 1 µl, each N7-end primer can perform 10 DNA library constructs, and each kit can perform 240 DNA library constructs.Products IntroductionThis kit is a companion kit to the transposase-based Rapid DNA Library Construction Kit for Illumina platform library construction. Each kit contains one N5 primer and 24 N7 primers, which can be used to prepare 24 different single-ended Index libraries. All reagents provided in the kits have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The libraries can be used for sequencing on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Kangwei Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes; Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers. procedureFor the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol. Index N501 Primer for Illumina Index N901-N996 Primer for Illumina... Read More | Product introduction:Griess reagent can be used for spectrophotometric detection of nitrite. The reagent contains two chemicals, sulfonic acid and n- (1-naphthyl) ethylenediamine. Under acidic conditions, sulfamic acid is converted into diazonium salt by nitrite, which can form a highly Product introduction:Griess reagent can be used for spectrophotometric detection of nitrite. The reagent contains two chemicals, sulfonic acid and n- (1-naphthyl) ethylenediamine. Under acidic conditions, sulfamic acid is converted into diazonium salt by nitrite, which can form a highly colored azo dye with n- (1-naphthyl) ethylenediamine. This dye can be detected at 548 nm: because no is extremely unstable, it is oxidized to form nitrite and nitrate. Griess indirectly reflects the content of no by detecting the content of nitrite.Matters needing attention:1. before using Griess reagent, return it to room temperature and check the solution for precipitation. If Griess reagent I contains sediment when taken out, it can be placed in a 37 ℃ water bath until the sediment dissolves. 2. this product is potentially harmful. Avoid prolonged or repeated exposure. Avoid entering eyes, skin or clothing. Please wear lab clothes and disposable gloves for operation.Scope of application:No detectionComponent:Instruction:1.Griess Reagent I and II were taken out to restore the room temperature.2.Standard dilution : The standard NaNO2 ( 1-100 µM ) was diluted with the solution used for the sample to be tested. The standard was diluted to 1 µM, 10 µM, 20 µM, 40 µM, 80 µM and 100 µM, and 100 µL standard was added to each well. If the sample concentration is too low, the range of the standard curve can be appropriately reduced ( 1 µM, 2 µM, 3 µM, 4 µM, 6 µM, 8 µM, 10 µM ).3.Sample detection :( 1 ) According to the total volume of 200 µL / hole, 100 µL / hole sample was added to the 96-well plate ; if the sample is the supernatant of the culture medium, it can be sampled directly, and if there is sediment, the supernatant should be taken after centrifugation. If the sample is a cell or tissue, it can be quickly lysed by freeze-thaw, and then centrifuged to obtain the supernatant. The volume of less than 100 µL can be diluted with diH2O or 0.9 % NaCl ( corresponding standards also need to be diluted with diH2O or 0.9 % NaCl ).( 2 ) According to 50 µL / hole, Griess Reagent I was added to each hole.( 3 ) According to 50 µL / hole, Griess Reagent II was added to each hole.( 4 ) The absorbance was measured at 540 nm. If there is no 540 nm filter, 520-560 nm filter can also be. If there is no microplate reader or a suitable filter, the concentration of nitric oxide in the sample can also be determined by visual colorimetry. A more precise concentration gradient is required for the standard when visual colorimetric... Read More |