| Description | Blood potassium plays a crucial role in maintaining normal osmotic pressure, acid-base balance, sugar and protein metabolism, and ensuring normal neuromuscular function. Its concentration is closely related to various important physiological functions. Abnormally high or low levels can disrupt Blood potassium plays a crucial role in maintaining normal osmotic pressure, acid-base balance, sugar and protein metabolism, and ensuring normal neuromuscular function. Its concentration is closely related to various important physiological functions. Abnormally high or low levels can disrupt normal physiological activities. Hyperkalemia increases neuromuscular excitability but decreases myocardial excitability, leading to bradycardia. Hypokalemia can cause muscle weakness or even flaccid paralysis, increase myocardial excitability, and result in tachycardia, arrhythmias, or even cardiac arrest during systole.Detection Principle: Potassium ions (K⁺) in serum react with sodium tetraphenylboron to form water-insoluble potassium tetraphenylboron. The turbidity produced is directly proportional to the potassium ion concentration within a certain range. The serum potassium ion content is determined by measuring this turbidity.Applicable Sample: SerumG1501769Component96 TStorageG1501769AExtraction Buffer50 mL2-8℃G1501769BReagentⅠ2.4 mL2-8℃G1501769CReagentⅡ1EA2-8℃. Store in the dark.G1501769DReagentⅢ20 mL2-8℃G1501769EStandard1 mL2-8℃Note: Before formal testing, it is recommended to perform a preliminary test with 2-3 samples expected to have significant differences.User-Prepared Instruments and ReagentsMicroplate reader or visible spectrophotometer (capable of measuring absorbance at 520 nm)96-well plate or micro glass cuvettes, adjustable micropipettes and tipsCentrifugeDeionized water, Concentrated Sulfuric AcidExperimental Procedure1. Reagent PreparationReagent NameReagent PreparationNotesExtraction Buffer/Slightly irritating. Use appropriate personal protective equipment during handling.Working Extraction BufferPrepare before use: Mix Extraction Buffer (mL) and Concentrated Sulfuric Acid (µL) in a 5:12 ratio as needed. Prepare freshly for each use.If precipitate forms, prepare a new batch.Reagent Ⅱ Working SolutionPrepare before use: Add the entire contents of Reagent Ⅰ into the Reagent Ⅱ vial. Mix well. This is the Reagent Ⅱ Working Solution.Can be stored at 4°C protected from light for one week.ReagentⅢPreheat in a 25°C water bath for at least 30 minutes before use./StandardReady-to-use; Equilibrate to room temperature before use.Store at 4°C.2. Sample PreparationSerum Pretreatment: Take a microcentrifuge tube. Sequentially add 50 µL of serum and 450 µL of Working Extraction Buffer. Mix thoroughly. Centrifuge at 8,000 rpm for 10 minutes at room temperature (approximately 25°C). Collect the supernatant for assay.3. Assay Steps3.1 Preheat the microplate reader or visible spectrophotometer for at least 30 minutes. Set the wavelength to 520 nm. For spectrophotometers, zero the instrument with deionized water.3.2 Assay Procedure (perform in a 96-well plate or micro glass cuvette):ReagentBlank Well (µL)Standard Well (µL)Test Well (µL)Deionized Water4000Standard0400Supernatant0040Reagent Ⅱ Working Solution202020Mix well and let stand for 5 minutes.ReagentⅢ1401401403.3 Mix well after addition. Measure the absorbance at 520 nm. Record the absorbance of the Blank well as A blank, the Standard well as A standard, and the Test well as A test. Note:The Blank and Standard tubes only need to be set up 1-2 times.It is recommended to perform a preliminary test with 2-3 samples expected to have significant differences before the formal experiment. If A <sub> test </sub> is less than 0.02, consider increasing the sample volume appropriately. If A <sub> test </sub> is greater than 1.1, further dilute the sample with Working Extraction Buffer (multiply the result by the dilution factor) or reduce the sample volume used for extraction.4. Calculation of ResultsNote: We provide both the derived formula and a simplified formula. They are equivalent. It is recommended to use the simplified formula in bold for final calculation.Blood Potassium Concentration (mmol/L) = [C Standard × (A test - A blank ) ÷ (A standard - A blank )] × n = 5 × (A test - A blank ) ÷ (A standard - A blank )Parameter Definitions:C Standard : 0.5 mmol/Ln: Sample dilution factor (10)Precautions1. Before formal testing, it is recommended to perform a preliminary test with 2-3 samples expected to have significant differences.2. Biochemical reagents are generally irritating and potentially biologically toxic. For your safety and health, please use appropriate biosafety precautions throughout the experiment, including wearing lab coats, masks, gloves, and head covers. Perform experiments in a fume hood or biosafety cabinet.3. This product is for research use only. Not for use in clinical diagnosis... Read More | This reagent kit is for research purposes only. Purpose of use: This reagent kit is used to determine the content of lactose in serum, plasma, and related liquid samples.Experimental principle:This kit applies enzyme-linked immunosorbent assay to determine the level of lactose in the sample. This reagent kit is for research purposes only. Purpose of use: This reagent kit is used to determine the content of lactose in serum, plasma, and related liquid samples.Experimental principle:This kit applies enzyme-linked immunosorbent assay to determine the level of lactose in the sample. Purified lactose antibodies were coated on a microplate to produce solid-phase antibodies. Lactose was added to the microplate of the coated monoclonal antibody, along with HRP labeled lactose antigens, to compete for binding. After thorough washing, the substrate TMB was added for colorimetry. The depth of sample color is negatively correlated with the content of lactose in the sample. Measure the absorbance (OD value) at a wavelength of 450nm using an enzyme-linked immunosorbent assay (ELISA) reader, and calculate the content of lactose in the sample through a standard curve.Kit composition:130times concentrated washing solution20ml×1 bottle8.1Standard S1(80µg/L)0.5ml×1bottle2Enzyme-linked immunosorbent assay6ml×1 bottle8.2Standard S2(40µg/L)0.5ml×1bottle3Enzyme labeling coated plate96 holes x 1 pieces8.3Standard S3(20µg/L)0.5ml×1bottle4Color reagent A solution6ml×1 bottle8.4Standard S4(10µg/L)0.5ml×1bottle5Color developer B solution6ml×1 bottle8.5Standard S5(5µg/L)0.5ml×1bottle6Stop solution6ml×1 bottle9Instructions1 copy7Sample Diluent6ml×1 bottle10Microplate Sealers2 sheetsSpecimen requirements:1. Specimen processing:(1) After collecting the water sample, it is repeatedly freeze-thawed three times at -20 ℃, and then filtered through glass fiber for future reference(2) The tissue samples should be extracted using butanol: methanol: water (5:25:70 V: V: V), or extracted according to relevant literature. The experiment should be conducted as soon as possible after extraction. If the experiment cannot be conducted immediately, the specimen can be stored at -20 ℃ for future reference2. Samples containing NaN3 cannot be detected as NaN3 inhibits the activity of horseradish peroxidase (HRP).Operation steps:1. Sample addition: Set up standard wells, blank wells (blank control wells do not include samples and enzyme-linked immunosorbent assay reagents, the other steps are the same), and sample wells to be tested. Add 50 microliters to the standard well on the enzyme-linked immunosorbent assay (ELISA) plate, and first add 40 diluents to the sample well to be tested µ l. Then add 10 more samples to be tested µ L (The final dilution of the sample is 5 times). Add the sample to the bottom of the enzyme-linked immunosorbent assay (ELISA) plate well, avoiding touching the well wall as much as possible. Gently shake and mix well.2. Enzyme addition: Add 50 enzyme labeled reagents to each well µ l. Excluding blank holes.3. Warm incubation: Seal the plate with a sealing film and incubate at 37 ℃ for 60 minutes.4. Solution preparation: Dilute 30 times the concentrated washing solution with distilled water and set aside for later use5. Washing: Carefully remove the sealing film, discard the liquid, shake dry, fill each well with washing solution, let it stand for 30 seconds, then discard. Repeat this process 5 times and pat dry.6. Color development: Add color development agent A50 to each well first µ l. Add color developer B50 again µ l. Gently shake and mix well, and develop color at 37 ℃ in the dark for 15 minutes7. Termination: Add 50% termination fluid to each hole µ l. Terminate the reaction (at this point, the blue color immediately turns yellow).8. Measurement: Zero the blank hole and sequentially measure the absorbance (OD value) of each hole at a wavelength of 450nm. The measurement should be conducted within 15 minutes after adding the termination solution.Calculation:Draw a standard curve on a coordinate paper with the concentration of the standard substance as the x-axis and the OD value as the y-axis. Based on the OD value of the sample, determine the corresponding concentration from the standard curve; Multiply it by the dilution factor; Alternatively, a linear regression equation can be used to calculate the standard curve using the concentration and OD value of the standard substance. The OD value of the sample can be substituted into the equation to calculate the sample concentration, which is then multiplied by the dilution factor to obtain the actual concentration of the sample.Notes:1. The kit should be balanced at room temperature for 15-30 minutes before use when taken out from the cold storage environment. If the enzyme coated plate is not used up after opening, the Flat noodles should be stored in a sealed bag.2. Concentrated detergent may precipitate crystals. When diluted, it can be heated in a water bath to aid in dissolution. Washing does not affect the results.3. A sampler should be used for each step of sample addition, and its accuracy should be regularly calibrated to avoid experimental errors. It is best to control the sample addition time within 5 minutes. If there are a large number of specimens, it is recommended to use a firing gun for sample addition.4. Please make a standard curve at the same time as each measurement, preferably with a re hole. If the content of the substance to be tested in the sample is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please dilute the sample diluent by a certain multiple (n times) before measurement. When calculating, please multiply the total dilution multiple (x n x 5).5. The sealing film is only for one-time use to avoid cross contamination.6. Please store the substrate in dark.7. Strictly follow the instructions and determine the test results based on the reading of the enzyme-linked immunosorbent assay (ELISA) reader8. All samples, washing liquids, and various waste should be treated as infectious substances.9. The components of this reagent with different batch numbers shall not be mixed.Detection range:two µ G/L-90 µ G/L... Read More | Inquire | DescriptionPhoto KitAlysis Starter Kit enables screening of 24 micro-scale simultaneous photocatalytic reactions with consistent and reproducible photon intensity. User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsComponents:Photo KitAlysis LED ControllerBlue LED DescriptionPhoto KitAlysis Starter Kit enables screening of 24 micro-scale simultaneous photocatalytic reactions with consistent and reproducible photon intensity. User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsComponents:Photo KitAlysis LED ControllerBlue LED Array (470 nm)Photo KitAlysis Reaction BlockTorque screwdriverSmall screwdriver to easily remove torqued screws after reaction is completeFeatures:Designed and tested by synthetic chemists.Controller provides repeatable milliamp selection for photon intensity0-30 mA variable LED output3 different LED options: blue (470 nm, included), green (527 nm, sold separately), and white (sold separately)Non-magnetic LED baseChemically resistant LED coverPTFE coated cablingDesigned to be used withPhoto KitAlysis High-Throughput Reaction Screening Kit(sold separately).Best when used withKitAlysis Benchtop Inertion Box(sold separately)... Read More | RAFT Agent Kit for controlling polymerizations at the molecular level detailed list of products: Catalog Number Product Name Component Catalog Number Component Name Component CAS Specification&Purity R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C139356-500mg 4-RAFT Agent Kit for controlling polymerizations at the molecular level detailed list of products: Catalog Number Product Name Component Catalog Number Component Name Component CAS Specification&Purity R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C139356-500mg 4-Cyano-4-(dodecylsulfanylthiocarbonyl)sulfanylpentanoic acid 870196-80-8 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C396701-500mg Cyanomethyl dodecyl trithiocarbonate 796045-97-1 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C396703-500mg Cyanomethyl methyl(phenyl)carbamodithioate 76926-16-4 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C168358-500mg 2-Cyano-2-propyl benzodithioate 201611-85-0 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C396706-500mg 2-(2-Cyanoprop-2-yl)-S-dodecyltrithiocarbonate 870196-83-1 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C132316-500mg 4-Cyano-4-(phenylcarbonothioylthio)pentanoic Acid 201611-92-9 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level S396708-500mg S,S-Dibenzyl trithiocarbonate 26504-29-0 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level D396711-500mg 2-(Dodecylthiocarbonothioylthio)-2-methylpropionic acid 461642-78-4 See Component Catalog Number... Read More |