| Description | Blood potassium plays a crucial role in maintaining normal osmotic pressure, acid-base balance, sugar and protein metabolism, and ensuring normal neuromuscular function. Its concentration is closely related to various important physiological functions. Abnormally high or low levels can disrupt Blood potassium plays a crucial role in maintaining normal osmotic pressure, acid-base balance, sugar and protein metabolism, and ensuring normal neuromuscular function. Its concentration is closely related to various important physiological functions. Abnormally high or low levels can disrupt normal physiological activities. Hyperkalemia increases neuromuscular excitability but decreases myocardial excitability, leading to bradycardia. Hypokalemia can cause muscle weakness or even flaccid paralysis, increase myocardial excitability, and result in tachycardia, arrhythmias, or even cardiac arrest during systole.Detection Principle: Potassium ions (K⁺) in serum react with sodium tetraphenylboron to form water-insoluble potassium tetraphenylboron. The turbidity produced is directly proportional to the potassium ion concentration within a certain range. The serum potassium ion content is determined by measuring this turbidity.Applicable Sample: SerumG1501769Component96 TStorageG1501769AExtraction Buffer50 mL2-8℃G1501769BReagentⅠ2.4 mL2-8℃G1501769CReagentⅡ1EA2-8℃. Store in the dark.G1501769DReagentⅢ20 mL2-8℃G1501769EStandard1 mL2-8℃Note: Before formal testing, it is recommended to perform a preliminary test with 2-3 samples expected to have significant differences.User-Prepared Instruments and ReagentsMicroplate reader or visible spectrophotometer (capable of measuring absorbance at 520 nm)96-well plate or micro glass cuvettes, adjustable micropipettes and tipsCentrifugeDeionized water, Concentrated Sulfuric AcidExperimental Procedure1. Reagent PreparationReagent NameReagent PreparationNotesExtraction Buffer/Slightly irritating. Use appropriate personal protective equipment during handling.Working Extraction BufferPrepare before use: Mix Extraction Buffer (mL) and Concentrated Sulfuric Acid (µL) in a 5:12 ratio as needed. Prepare freshly for each use.If precipitate forms, prepare a new batch.Reagent Ⅱ Working SolutionPrepare before use: Add the entire contents of Reagent Ⅰ into the Reagent Ⅱ vial. Mix well. This is the Reagent Ⅱ Working Solution.Can be stored at 4°C protected from light for one week.ReagentⅢPreheat in a 25°C water bath for at least 30 minutes before use./StandardReady-to-use; Equilibrate to room temperature before use.Store at 4°C.2. Sample PreparationSerum Pretreatment: Take a microcentrifuge tube. Sequentially add 50 µL of serum and 450 µL of Working Extraction Buffer. Mix thoroughly. Centrifuge at 8,000 rpm for 10 minutes at room temperature (approximately 25°C). Collect the supernatant for assay.3. Assay Steps3.1 Preheat the microplate reader or visible spectrophotometer for at least 30 minutes. Set the wavelength to 520 nm. For spectrophotometers, zero the instrument with deionized water.3.2 Assay Procedure (perform in a 96-well plate or micro glass cuvette):ReagentBlank Well (µL)Standard Well (µL)Test Well (µL)Deionized Water4000Standard0400Supernatant0040Reagent Ⅱ Working Solution202020Mix well and let stand for 5 minutes.ReagentⅢ1401401403.3 Mix well after addition. Measure the absorbance at 520 nm. Record the absorbance of the Blank well as A blank, the Standard well as A standard, and the Test well as A test. Note:The Blank and Standard tubes only need to be set up 1-2 times.It is recommended to perform a preliminary test with 2-3 samples expected to have significant differences before the formal experiment. If A <sub> test </sub> is less than 0.02, consider increasing the sample volume appropriately. If A <sub> test </sub> is greater than 1.1, further dilute the sample with Working Extraction Buffer (multiply the result by the dilution factor) or reduce the sample volume used for extraction.4. Calculation of ResultsNote: We provide both the derived formula and a simplified formula. They are equivalent. It is recommended to use the simplified formula in bold for final calculation.Blood Potassium Concentration (mmol/L) = [C Standard × (A test - A blank ) ÷ (A standard - A blank )] × n = 5 × (A test - A blank ) ÷ (A standard - A blank )Parameter Definitions:C Standard : 0.5 mmol/Ln: Sample dilution factor (10)Precautions1. Before formal testing, it is recommended to perform a preliminary test with 2-3 samples expected to have significant differences.2. Biochemical reagents are generally irritating and potentially biologically toxic. For your safety and health, please use appropriate biosafety precautions throughout the experiment, including wearing lab coats, masks, gloves, and head covers. Perform experiments in a fume hood or biosafety cabinet.3. This product is for research use only. Not for use in clinical diagnosis... Read More | Product IntroductionBCIP (5-Bromo-4-chloro-3-indolyl phosphate) 5-bromo-4-chloro-3-indolyl-phosphate + NBT (tetrazolium nitro blue) is the best substrate for alkaline phosphatase (AP) One of the combination. Under the catalysis of alkaline phosphatase, BCIP will be hydrolyzed to produce a highly Product IntroductionBCIP (5-Bromo-4-chloro-3-indolyl phosphate) 5-bromo-4-chloro-3-indolyl-phosphate + NBT (tetrazolium nitro blue) is the best substrate for alkaline phosphatase (AP) One of the combination. Under the catalysis of alkaline phosphatase, BCIP will be hydrolyzed to produce a highly reactive product, which reacts with NBT to form an insoluble dark blue to blue-violet compound. This kit can be used for the enzymatic color development of IHC and Western Blot experiments of the AP system. Under AP catalysis, a dark blue precipitate is produced where AP conjugates are combined on tissue sections or blotting membranes. The location and expression of the target protein can be determined based on the color reaction.Product Components40×BCIP: 1 ml40×NBT: 1 mlBCIP/NBT Buffer: 40 mlPrecautions1. The working fluid should be prepared for immediate use, and the prepared working fluid will be effective within 1 hour.2. The amount of working fluid must be sufficient to ensure complete coverage of the tissue sheet or blotting membrane. To3. In order to obtain the best experimental results, be sure to optimize the experimental conditions.4. NBT is poisonous, please take necessary protective measures when using it.5. This product is only used for scientific research, not for human experiments or human treatment.Instructions1. BCIP/NBT color developing working solution preparation:According to the required amount, mix 40×BCIP, 40×NBT and BCIP/NBT Buffer in a volume ratio of 1:1:38 to form the BCIP/NBT color developing working solution.2. Color rendering:1) Blotting membrane color development: Drop the prepared working solution on the blotting membrane (or pour the blotting membrane into the BCIP/NBT color developing working solution), and incubate for 3-10 minutes at room temperature and dark. After the color development is completed, the film is immersed in water to terminate the reaction.2) Color development of tissue sections or cell slides: Drop an appropriate amount of BCIP/NBT color developing working solution on the tissue sections or cell slides that need color development, and incubate at room temperature for 3-10 minutes in the dark. Observe under the microscope to control the color development time. When the best color development effect is reached, rinse with tap water to stop the color development. After color development, the slices are counter-stained, dehydrated and transparent, and can be stored for a long time after mounting... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Products contentN669983Component240 TStorageN669983AIndex N501 Primers for Illumina240 µL-20℃. Avoid freeze/thaw cycle.N669983BIndex N973-N996 Primers for Illumina24×10 µL-20℃. Avoid freeze/thaw cycle. Products IntroductionThis kit is a companion kit to the transposase-Products contentN669983Component240 TStorageN669983AIndex N501 Primers for Illumina240 µL-20℃. Avoid freeze/thaw cycle.N669983BIndex N973-N996 Primers for Illumina24×10 µL-20℃. Avoid freeze/thaw cycle. Products IntroductionThis kit is a companion kit to the transposase-based Rapid DNA Library Construction Kit for Illumina platform library construction. Each kit contains one N5 primer and 24 N7 primers, which can be used to prepare 24 different single-ended Index libraries. All reagents provided in the kits have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The libraries can be used for sequencing on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes;Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers. ProcedureFor the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol.Index N501 Primer for IlluminaIndex N901-N996 Primer for Illumina... Read More | Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly luciferase is widely used in gene regulation and drug screening. Firefly luciferase is a protein with a molecular weight of about 61 KD. In the presence of ATP, magnesium ions and oxygen, it can catalyze the production of oxyluciferin from luciferin. In the process of luciferin oxidation, it will produce a light signal. The optical signal of this kit is a kind of instantaneous light, which needs to be detected immediately after adding the working solution. The half-life of optical signal is about 5 min.Instruction:1.Working fluid configuration ( 1 ) Restore all components to room temperature. ( 2 ) The component B ( stock solution ) was fully diluted with component A to prepare a 0.2 mg / mL firefly luciferase working solution, which was vortexed and shaken to ensure full mixing. Note : The firefly luciferase working solution cannot be repeatedly frozen and thawed. If the dosage of a single experiment is small, it is recommended to subpackage according to a single dosage. At room temperature, the activity decreased by about 10 % after the working solution was configured for 3 h, and the activity decreased by about 25 % after 5 h. 2.chemiluminescence value detection ( 1 ) The cell culture plate was taken out from the incubator and incubated at room temperature for 20 min to restore it to room temperature ( 22-25 ° C ). ( 2 ) Add the same volume of firefly luciferase working solution with the medium to the culture plate and mix well. ( 3 ) Incubation at room temperature for 5 min. Note : The incubation time can be adjusted according to cell type and cell number. ( 4 ) The values were read by multifunctional microplate reader or chemiluminescence instrument ( instrument parameters : the determination time was 10 s, the determination interval was 2 s ).Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. the strongest wavelength of bioluminescence catalyzed by firefly luciferase is 560 nm. 3. to prevent interference between holes, it is recommended to use white opaque orifice plate.Recommendation:Component B is recommended to use sterile water in advance to configure 2 mg / mL storage solution, A component and B component configured as storage solution, and small batch packaging according to the experimental requirements. The detection working fluid is recommended to be used now to avoid repeated freezing and thawing. Component:One-Step Firefly Luciferase Assay Buffer;D-Luciferin Scope of application:Mainly used for ADCC detection... Read More |